Test Report

FCC ID: KE3-PIF150

Test Report

Download: PDF
FCCID_1948788

Reference No.: WTS13S0302215E                     Page 1 of 22




                           FCC TEST REPORT
FCC ID                         : KE3-PIF150
Applicant                      : Radio Systems Corporation
Address                        : 10427 Petsafe Way Knoxville,TN 37932 United States
Manufacturer                   : Radio Systems Corporation
Address                        : 10427 Petsafe Way Knoxville,TN 37932 United States
Equipment Under Test (EUT) :
 Product Name                  : PetSafe Premium Wireless Fence Transmitter
 Model No.                     : PIF-150


Rule                           : FCC CFR47 Part 15 Section 15.209:2010


Date of Test                   : March 29 ~ 30, 2013
Date of Issue                  : April 10, 2013
Test Result                    : Pass *

Remarks:
The results shown in this test report refer only to the sample(s) tested, this test report cannot be
reproduced, except in full, without prior written permission of the company.
The report would be invalid without specific stamp of test institute and the signatures of compiler and
approver.
                                                 Prepared By:
                                  Waltek Services (Shenzhen) Co., Ltd.
    Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                               Guangdong, China
Testing location: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                               Guangdong, China
                                            Tel :+86-755-83551033
                                            Fax:+86-755-83552400
Compiled by:                                                     Approved by:




Zero Zhou / Project Engineer                                     Philo Zhong / Manager




   Waltek Services (Shenzhen) Co.,Ltd.
   http://www.waltek.com.cn


Reference No.: WTS13S0302215E                        Page 2 of 22



2    Test Summary

             Test Items         Test Requirement               Test Method      Result
        Conducted Emissions            Part 15.207           ANSI C63.4:2003    PASS
         Radiated Emissions            Part 15.209           ANSI C63.4: 2003   PASS
      Remark:
      PASS                        Test item meets the requirement
      FAIL                        Test item does not meet the requirement
      N/A                         Test case does not apply to the test object




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E                                                      Page 3 of 22



3       Contents
                                                                                                                                                            Page
1      COVER PAGE..................................................................................................................................................... 1

2      TEST SUMMARY ............................................................................................................................................... 2

3      CONTENTS ......................................................................................................................................................... 3

4      GENERAL INFORMATION ............................................................................................................................... 4
       4.1     GENERAL DESCRIPTION OF E.U.T. ............................................................................................................. 4
       4.2     DETAILS OF E.U.T. ...................................................................................................................................... 4
       4.3     TEST FACILITY.............................................................................................................................................. 4
       4.4     TEST LOCATION ........................................................................................................................................... 4
5      EQUIPMENT USED DURING TEST................................................................................................................ 5
       5.1     EQUIPMENTS LIST ........................................................................................................................................ 5
       5.2     MEASUREMENT UNCERTAINTY .................................................................................................................... 5
       5.3     TEST EQUIPMENT CALIBRATION .................................................................................................................. 5
6      CONDUCTED EMISSIONS ............................................................................................................................... 6
       6.1     E.U.T. OPERATION ...................................................................................................................................... 6
       6.2     TEST PROCEDURE ....................................................................................................................................... 6
       6.3     TEST SETUP ................................................................................................................................................. 6
       6.4     TEST RESULT ............................................................................................................................................... 7
7      RADIATED EMISSIONS .................................................................................................................................... 9
       7.1     EUT OPERATION ......................................................................................................................................... 9
       7.2     TEST PROCEDURE ..................................................................................................................................... 10
       7.3     TEST SETUP ............................................................................................................................................... 11
       7.4     SPECTRUM ANALYZER SETUP ................................................................................................................... 12
       7.5     CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................. 12
       7.6     TEST RESULTS ........................................................................................................................................... 12
8      PHOTOGRAPHS–TEST SETUP.................................................................................................................... 15
       8.1     PHOTOGRAPH –CONDUCTED EMISSIONS TEST SETUP ............................................................................ 15
       8.2     PHOTOGRAPH – RADIATION EMISSIONS TEST SETUP .............................................................................. 15
9      PHOTOGRAPHS - CONSTRUCTIONAL DETAILS .................................................................................... 17
       9.1     EUT – APPEARANCE VIEW ........................................................................................................................ 17
       9.2     EUT – OPEN VIEW .................................................................................................................................... 19
       9.3     EUT – PCB VIEW ...................................................................................................................................... 20
       9.4     ADAPTER – APPEARANCE VIEW ................................................................................................................ 21




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


Reference No.: WTS13S0302215E                            Page 4 of 22



4       General Information
4.1     General Description of E.U.T.
        Product Name                    : PetSafe Premium Wireless Fence Transmitter
        Model No.                       : PIF-150
        Model Difference                : N/A
        Operation Frequency             : 18.726kHz

4.2     Details of E.U.T.

        Technical Data:                 : DC 19V , 1.3A powered by adapter
                                          (input: 100-240V~ 50/60Hz 0.8A max.)
        Adapter model:                  : ITC-19V1.3C
        Adapter manufacturer:           : Radio Systems Corporation

4.3     Test Facility
        The test facility has a test site registered with the following organizations:

       IC – Registration No.: 7760A
        Waltek Services(Shenzhen) Co., Ltd. has been registered and fully described in a report filed with
        the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files.
        Registration number 7760A, July 12, 2012.

       FCC – Registration No.: 880581
        Waltek Services(Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a
        report filed with the (FCC) Federal Communications Commission. The acceptance letter from the
        FCC is maintained in our files. Registration 880581, May 26, 2011.


4.4     Test Location
        All the tests were performed at:
        Waltek Services(Shenzhen) Co., Ltd. at 1/F, Fukangtai Building, West Baima Rd., Songgang Street,
        Baoan District, Shenzhen, China




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


   Reference No.: WTS13S0302215E                        Page 5 of 22



   5       Equipment Used during Test

   5.1     Equipments List

Conducted Emissions
                                                                                         Last
                                                                                                     Calibration
 Item         Equipment             Manufacturer        Model No.       Serial No.    Calibration
                                                                                                      Due Date
                                                                                         Date
  1.       EMI Test Receiver            R&S               ESCI           101178       Aug. 13,2012   Aug. 13,2013
  2.              LISN                  R&S              ENV216          101215       Aug. 13,2012   Aug. 13,2013
  3.             Cable             HUBER+SUHNER       CBL2-NN-3M        2230300       Aug. 13,2012   Aug. 13,2013
  4.             Switch                  ---             RSU/M2             ---       Aug. 13,2012   Aug. 13,2013
3m Semi-anechoic Chamber for Radiation Emissions
                                                                                         Last
                                                                                                     Calibration
 Item                                                                                 Calibration
                                                                                                      Due Date
              Equipment             Manufacturer        Model No.       Serial No.       Date
  1.         EMC Analyzer              Agilent           E7405A        MY45114943 Aug. 13,2012       Aug. 13,2013
  2.      Active Loop Antenna       Beijing Dazhi       ZN30900A             -        Aug. 13,2012   Aug. 13,2013
            Trilog Broadband
  3.                               SCHWARZBECK          VULB9163           336
                 Antenna                                                              Aug. 13,2012   Aug. 13,2013
            Broad-band Horn
  4.                               SCHWARZBECK        BBHA 9120 D          667
                 Antenna                                                              Aug. 13,2012   Aug. 13,2013
            Broad-band Horn
  5.                               SCHWARZBECK         BBHA 9170           399
                 Antenna                                                              Aug. 13,2012   Aug. 13,2013
                Broadband
  6.                               SCHWARZBECK          BBV 9719        9719-254
               Preamplifier                                                           Aug. 13,2012   Aug. 13,2013
                Broadband
  7.                               SCHWARZBECK          BBV 9718        9718-148
               Preamplifier                                                           Aug. 13,2012   Aug. 13,2013
           10m Coaxial Cable
  8.                               SCHWARZBECK          AK 9515 H            -
               with N- plug                                                           Aug. 13,2012   Aug. 13,2013
          10m 50 Ohm Coaxial
  9.                               SCHWARZBECK           AK 9513             -
            Cable with N-plug                                                         Aug. 13,2012   Aug. 13,2013
 10.      Positioning Controller     C&C LAB             CC-C-IF             -        Aug. 13,2012   Aug. 13,2013
 11.          Color Monitor           SUNSPO             SP-14C              -        Aug. 13,2012   Aug. 13,2013

   5.2     Measurement Uncertainty
            Parameter                               Uncertainty
                                                    ± 5.03 dB
            Radiated Spurious                       (9KHz~1000MHz)
            Emissions test                          ± 4.74 dB
                                                    (1000M~25000MHz)
            Conducted Spurious                      ± 3.64 dB
            Emissions test                          (AC mains 150KHz~30MHz)

   5.3     Test Equipment Calibration
           All the test equipments used are valid and calibrated by CEPREI Certification Body that
           address is No.110 Dongguan Zhuang RD. Guangzhou, P.R.China.

       Waltek Services (Shenzhen) Co.,Ltd.
       http://www.waltek.com.cn


Reference No.: WTS13S0302215E                       Page 6 of 22



6     Conducted Emissions
      Test Requirement               : FCC CFR47 Part 15 Section 15.207
      Test Method                    : ANSI C63.4:2003
      Test Result                    : PASS
      Frequency Range                : 150kHz to 30MHz
      Limit                          : 66-56 dBV between 0.15MHz & 0.5MHz
                                      56 dBV between 0.5MHz & 5MHz
                                      60 dBV between 5MHz & 30MHz
      Detector                       : Peak for pre-scan (9kHz Resolution Bandwidth)
                                      Quasi-Peak & Average if maximised peak within 6dB of Average
                                      Limit

6.1   E.U.T. Operation
      Operating Environment:
      Temperature                    : 26 C
      Humidity                       : 54% RH
      Atmospheric Pressure           : 1010 mbar

6.2   Test Procedure
      (1) The EUT was tested according to ANSI C63.4:2003. The frequency spectrum from 150kHz to
          30MHz was investigated.
      (2) The maximised peak emissions from the EUT was scanned and measured for both the Live and
          Neutral Lines. Quasi-peak & average measurements were performed if peak emissions were
          within 6dB of the average limit line.

6.3   Test Setup
       The EUT was placed on the test table in shielding room




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E          Page 7 of 22


6.4   Test Result

      Test Mode:Working Mode
      Live line:




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E          Page 8 of 22




     Neutral line:




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E                              Page 9 of 22



7     Radiated Emissions
      Test Requirement                   : FCC CFR47 Part 15 Section 15.209
      Test Method                        : ANSI C63.4:2003
      Test Result                        : PASS
      Frequency Range                    : 9kHz to 1GHz
      Measurement Distance               : 3m


      Limit:
                                    Field Strength              Field Strength Limit at 3m Measurement Dist
          Frequency
                                                  Distance
               (MHz)            uV/m                                      uV/m                 dBuV/m
                                                     (m)
                                                                                               (2400/F(kHz))
        0.009 ~ 0.490       2400/F(kHz)              300       10000 * 2400/F(kHz)     20log                   + 80
                                                                                            (24000/F(kHz))
        0.490 ~ 1.705       24000/F(kHz)             30         100 * 24000/F(kHz)     20log                   + 40
                                                                                                   (30)
          1.705 ~ 30                30               30              100 * 30             20log           + 40
                                                                                                      (100)
               30 ~ 88           100                   3                  100                  20log
                                                                                                      (150)
           88 ~ 216              150                   3                  150                  20log
                                                                                                      (200)
           216 ~ 960             200                   3                  200                  20log
                                                                                                      (500)
          Above 960              500                   3                  500                  20log
      Note:
      a) The tighter limit applies at the band edges.
          For example: F.S limit at 88MHz is 100uV/m
      b) If measurement is made at 3m distance, then F.S Limit at 3m distance is adjusted by using the
                                           2
          formula of Ld1 = Ld2 * (d2/d1) .
          For example:
          F.S Limit at 30m(d2) distance is 30uV/m(Ld2), then F.S Limit at 3m(d1) distance is
                                2
          Ld1 = 30uV/m * (30/3) = 100 * 30uV/m


7.1   EUT Operation

      Operating Environment:

      Temperature                        : 25.5 C
      Humidity                           : 52% RH
      Atmospheric Pressure               : 1016 mbar




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E                        Page 10 of 22



7.2   Test Procedure

      a) Test Procedure (below 30MHz)
      (1) The EUT is placed on a turntable, which is 0.8m above ground plane.
      (2) The turntable shall be rotated for 360 degrees to determine the position of maximum emission
          level.
      (3) EUT is set 3m away from the receiving antenna.
      (4) Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
      (5) Repeat above procedures until the measurements for all frequencies are complete.
      (6) The radiation measurements are performed in X,Y,Z axes position(X denotes lying on the table,
          Y denotes side stand and Z denotes vertical stand), the worst is X position.
      (7) AC source used during test.
      (8) A calculated substitution wire ring antenna used during test.

      b) Test Procedure (above 30MHz)
      (1) The EUT is placed on a turntable, which is 0.8m above ground plane.
      (2) The turntable shall be rotated for 360 degrees to determine the position of maximum emission
          level.
      (3) EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the
          maximum emissions.
      (4) Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
      (5) And also, each emission was to be maximized by changing the polarization of receiving antenna
          both horizontal and vertical.
      (6) Repeat above procedures until the measurements for all frequencies are complete.
      (7) The radiation measurements are performed in X,Y,Z axes position(X denotes lying on the table,
          Y denotes side stand and Z denotes vertical stand), the worst is X position.
      (8) AC source used during test.
      (9) A calculated substitution wire ring antenna used during test.




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E                     Page 11 of 22



7.3   Test Setup

      The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site.
      a) Radiated Emission Test Setup, Frequency Below 30MHz




      b) Radiated Emission Test Setup, Frequency range 30MHz ~ 1000MHz




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E                                  Page 12 of 22



7.4   Spectrum Analyzer Setup

      According to FCC Part15 Rules, the system was tested 9kHz to 1000MHz.

                     Below 30MHz:

                     Sweep Speed ..................................................... Auto
                     IF Bandwidth         .................................................... 10 KHz
                     Video Bandwidth................................................... 10KHz
                     Resolution Bandwidth ........................................... 10KHz


                     Above 30MHz:

                     Sweep Speed ..................................................... Auto
                     IF Bandwidth        ..................................................... 120 KHz
                     Video Bandwidth................................................... 100KHz
                     Quasi-Peak Adapter Bandwidth ........................... 120 KHz
                     Quasi-Peak Adapter Mode ................................... Normal
                     Resolution Bandwidth ........................................... 120kHz


7.5   Corrected Amplitude & Margin Calculation

      Formula of conversion factors:the field strength at 3m was established by adding the meter reading
      of the spectrum analyzer (which is set to read in units of dBuV/m) to the antenna correction factor
      supplied by the antenna manufacturer. The antenna correction factors are stared in terms of dB.
      The gain of the pressletor was accounted for in the spectrum analyser meter reading.
          Example:
          Freq(MHz) Meter Reading +ACF=FS
           33          20dBuV+10.36dB=30.36dBuV/m @3m


7.6   Test Results
      Test frequency below 30MHz:

        Frequency                            Level                 Limit               Margin            Measurement
                        Detector
           (kHz)                          (dBuV/m)              (dBuV/m)                 (dB)            Distance (m)

          18.726           peak              91.35                  127                -35.65                 3
       No suspicious signal found in other frequency that other emissions are more than 20dB
       below the limit,the data do not report .




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E          Page 13 of 22



    Test frequency above 30MHz
    Test Mode: Working Mode
    Antenna Porlarization: Vertical




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E           Page 14 of 22




    Antenna Porlarization: Horizontal




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E               Page 15 of 22



8     Photographs–Test Setup
8.1   Photograph –Conducted Emissions Test Setup




8.2   Photograph – Radiation Emissions Test Setup

                                       Below 30MHz




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E               Page 16 of 22




                                       Above 30MHz




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E          Page 17 of 22



9     Photographs - Constructional Details
9.1   EUT – Appearance View




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E          Page 18 of 22




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E          Page 19 of 22



9.2   EUT – Open View




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E          Page 20 of 22



9.3   EUT – PCB View




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E          Page 21 of 22



9.4   Adapter – Appearance View




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0302215E                   Page 22 of 22




                                       =End of test report==




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn



Document Created: 2013-04-20 09:12:22
Document Modified: 2013-04-20 09:12:22

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC