Test Report

FCC ID: KE3-3002769

Test Report

Download: PDF
FCCID_2087141

Reference No.: WTS13S0705883E                   Page 1 of 22




                          FCC TEST REPORT
FCC ID                      : KE3-3002769
Applicant                   : Radio Systems Corporation
Address                     : 10427 Petsafe Way Knoxville,TN 37932 USA
Manufacturer                : The same as above
Address                     : The same as above
Equipment Under Test (EUT) :
 Product Name               : INDOOR SHIELDS PLUS
 Model No.                  : RAC00-14112


Rule                        : FCC CFR47 Part 15 Section 15.209:2010


Date of Test                : August 25, 2013
Date of Issue               : September 09, 2013
Test Result                 : Pass *
Remarks:
The results shown in this test report refer only to the sample(s) tested, this test report cannot be
reproduced, except in full, without prior written permission of the company.
The report would be invalid without specific stamp of test institute and the signatures of compiler and
approver.
                                                Prepared By:
                                  Waltek Services (Shenzhen) Co., Ltd.
   Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                              Guangdong, China
Testing location: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                              Guangdong, China
                                           Tel :+86-755-83551033
                                           Fax:+86-755-83552400
Compiled by:                                                   Approved by:




Maikou Zhang / Project Engineer                                Philo Zhong / Manager




   Waltek Services (Shenzhen) Co.,Ltd.
   http://www.waltek.com.cn


Reference No.: WTS13S0705883E                        Page 2 of 22



2    Test Summary

             Test Items         Test Requirement               Test Method      Result
        Conducted Emissions            Part 15.207           ANSI C63.4:2003    PASS
         Radiated Emissions            Part 15.209           ANSI C63.4: 2003   PASS
      Remark:
      PASS                        Test item meets the requirement
      FAIL                        Test item does not meet the requirement
      N/A                         Test case does not apply to the test object




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E                                                     Page 3 of 22



3       Contents


                                                                                                                                                             Page
1      COVER PAGE .................................................................................................................................................... 1

2      TEST SUMMARY ...............................................................................................................................................2

3      CONTENTS .........................................................................................................................................................3

4      GENERAL INFORMATION...............................................................................................................................4
       4.1     GENERAL DESCRIPTION OF E.U.T. .............................................................................................................4
       4.2     DETAILS OF E.U.T........................................................................................................................................4
       4.3     TEST FACILITY ..............................................................................................................................................4
       4.4     TEST LOCATION............................................................................................................................................4
5      EQUIPMENT USED DURING TEST ...............................................................................................................5
       5.1     EQUIPMENTS LIST ........................................................................................................................................5
       5.2     MEASUREMENT UNCERTAINTY ....................................................................................................................5
       5.3     TEST EQUIPMENT CALIBRATION ..................................................................................................................5
6      CONDUCTED EMISSIONS...............................................................................................................................6
       2.1     E.U.T. OPERATION ......................................................................................................................................6
       2.2     EUT SETUP ..................................................................................................................................................6
       2.3     CONDUCTED EMISSION TEST RESULT.........................................................................................................7
7      RADIATED EMISSIONS ...................................................................................................................................9
       7.1     EUT OPERATION..........................................................................................................................................9
       7.2     TEST PROCEDURE .....................................................................................................................................10
       7.3     TEST SETUP ...............................................................................................................................................11
       7.4     SPECTRUM ANALYZER SETUP ...................................................................................................................12
       7.5     CORRECTED AMPLITUDE & MARGIN CALCULATION ..................................................................................12
       7.6     TEST RESULTS ...........................................................................................................................................13
8      PHOTOGRAPHS–TEST SETUP ...................................................................................................................16
       8.1     CONDUCTED EMISSIONS ............................................................................................................................16
       8.2     PHOTOGRAPH – RADIATION EMISSIONS TEST SETUP...................................................................................16
9      PHOTOGRAPHS - CONSTRUCTIONAL DETAILS ...................................................................................18
       9.1     EUT – APPEARANCE VIEW ........................................................................................................................18
       9.2     EUT – OPEN VIEW .....................................................................................................................................21




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


Reference No.: WTS13S0705883E                           Page 4 of 22



4       General Information
4.1     General Description of E.U.T.
        Product Name                   : INDOOR SHIELDS PLUS
        Model No.                      : RAC00-14112
        Model Difference               : N/A
        Operation Frequency            : 7.5kHz~10.5kHz

4.2     Details of E.U.T.

        Technical Data:                : DC 3.7V, 1900mAh by Internal lithium battery

4.3     Test Facility
        The test facility has a test site registered with the following organizations:

•       IC – Registration No.: 7760A
        Waltek Services(Shenzhen) Co., Ltd. has been registered and fully described in a report filed with
        the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files.
        Registration number 7760A, July 12, 2012.

•       FCC – Registration No.: 880581
        Waltek Services(Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a
        report filed with the (FCC) Federal Communications Commission. The acceptance letter from the
        FCC is maintained in our files. Registration 880581, May 26, 2011.


4.4     Test Location
        All the tests were performed at:
        Waltek Services(Shenzhen) Co., Ltd. at 1/F, Fukangtai Building, West Baima Rd., Songgang Street,
        Baoan District, Shenzhen, China




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


   Reference No.: WTS13S0705883E                        Page 5 of 22



   5       Equipment Used during Test

   5.1     Equipments List
                                                                                        Last
                                                                                                     Calibration
Item         Equipment           Manufacturer        Model No.         Serial No.    Calibration
                                                                                                      Due Date
                                                                                        Date
   1.     EMI Test Receiver        R&S          ESCI      101155                    Aug. 13,2012
                                                                                  Aug. 12,2013
   2.            LISN       SCHWARZBECK      NSLK 8128   8128-289                   Aug. 13,2012
                                                                                  Aug. 12,2013
   3.           Cable           LARGE           RF300   EW02014-3                   Aug.14,2012
                                                                                  Aug. 13,2013
3m Semi-anechoic Chamber for Radiation Emissions
   1.      EMC Analyzer          Agilent       E7405A   MY45114943 Aug. 13,2012 Aug. 12,2013
   2.   Active Loop Antenna   Beijing Dazhi   ZN30900A       -      Aug. 13,2012 Aug. 12,2013
          Trilog Broadband
   3.                       SCHWARZBECK       VULB9163      336     Apr. 20,2013  Apr. 19,2014
               Antenna
          Broad-band Horn
   4.                       SCHWARZBECK BBHA 9120 D         667     Apr. 20,2013  Apr. 19,2014
               Antenna
          Broad-band Horn
   5.                       SCHWARZBECK      BBHA 9170      399     Aug. 13,2012 Aug. 12,2013
               Antenna
              Broadband      COMPLIANCE
   6.                                         PAP-1G18     2004      Apr.07,2013   Apr.06,2014
             Preamplifier     DIRECTION
              Broadband
   7.                       SCHWARZBECK       BBV 9718   9718-148   Aug. 13,2012 Aug. 12,2013
             Preamplifier
   8.           Cable              Top       EWO2014-7       -      Apr. 20,2013  Apr. 19,2014
   9.           Cable              Top      TYPE16(13M)      -      Aug. 13,2012 Aug. 12,2013
  10. DC POWER SUPPLY          LWDQGS          PS-303D              Aug. 13,2012 Aug. 12,2013
  11.     Humidity Chamber  GTH-225-40-1P    IAA061213              May. 15, 2013 May. 14, 2014
                               ROHDE &
  12.    Spectrum Analyzer                      FSL6                Sep. 21, 2012 Sep. 20, 2013
                               SCHWARZ
Auxiliary equipment
                                                                        Last
                                                                                   Calibration
 Item        Equipment       Manufacturer     Model No.  Serial No.  Calibration
                                                                                    Due Date
                                                                        Date
   1           Adapter             GOE          GS2U         --           --            --

   5.2     Measurement Uncertainty
            Parameter                              Uncertainty

            Radiated Spurious Emissions test       ± 5.03 dB (9KHz~1000MHz)


   5.3     Test Equipment Calibration
           All the test equipments used are valid and calibrated by CEPREI Certification Body that
           address is No.110 Dongguan Zhuang RD. Guangzhou, P.R.China.




       Waltek Services (Shenzhen) Co.,Ltd.
       http://www.waltek.com.cn


Reference No.: WTS13S0705883E                          Page 6 of 22



6     Conducted Emissions
      Test Requirement                 : FCC CFR47 Part 15 Section 15.207
      Test Method                      : ANSI C63.4:2003
      Test Result                      : PASS
      Frequency Range                  : 150kHz to 30MHz
      Limit                            : 66-56 dBμV between 0.15MHz & 0.5MHz
                                        56 dBμV between 0.5MHz & 5MHz
                                        60 dBμV between 5MHz & 30MHz
      Detector                         : Peak for pre-scan (9kHz Resolution Bandwidth)
                                        Quasi-Peak & Average if maximised peak within 6dB of Average
                                        Limit


2.1   E.U.T. Operation

        Operating Environment:
              Temperature:              26 °C
              Humidity: 50 % RH
              Atmospheric Pressure: 1010 mbar
        EUT Operation:
          The EUT was tested in RF and charging mode with Adapter(The adapter is Auxiliary
          equipment).
              The EUT was tested according to ANSI C63.4:2003. The frequency spectrum from 150kHz to
              30MHz was investigated.
              The maximised peak emissions from the EUT was scanned and measured for both the Live
              and Neutral Lines. Quasi-peak & average measurements were performed if peak emissions
              were within 6dB of the average limit line.
2.2   EUT Setup
      The conducted emission tests were performed using the setup accordance with the ANSI
      C63.4:2003.




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E                       Page 7 of 22


2.3   Conducted Emission Test Result

      An initial pre-scan was performed on the live and neutral lines.
       Live line:




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E          Page 8 of 22



     Neutral line:




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E                            Page 9 of 22



7     Radiated Emissions
      Test Requirement                 : FCC CFR47 Part 15 Section 15.209
      Test Method                      : ANSI C63.4:2003
      Test Result                      : PASS
      Frequency Range                  : 9kHz to 1GHz
      Measurement Distance             : 3m
      Limit:
                                  Field Strength             Field Strength Limit at 3m Measurement Dist
          Frequency
                                                Distance
               (MHz)            uV/m                                    uV/m               dBuV/m
                                                   (m)
        0.009 ~ 0.490       2400/F(kHz)            300       10000 * 2400/F(kHz)    20log(2400/F(kHz)) + 80
        0.490 ~ 1.705       24000/F(kHz)           30         100 * 24000/F(kHz)    20log(24000/F(kHz)) + 40
          1.705 ~ 30              30               30              100 * 30             20log(30) + 40
               30 ~ 88           100                 3                  100               20log(100)
           88 ~ 216              150                 3                  150               20log(150)
           216 ~ 960             200                 3                  200               20log(200)
          Above 960              500                 3                  500               20log(500)
      Note:
      a) The tighter limit applies at the band edges.
          For example: F.S limit at 88MHz is 100uV/m
      b) If measurement is made at 3m distance, then F.S Limit at 3m distance is adjusted by using the
          formula of Ld1 = Ld2 * (d2/d1)2.
          For example:
          F.S Limit at 30m(d2) distance is 30uV/m(Ld2), then F.S Limit at 3m(d1) distance is
          Ld1 = 30uV/m * (30/3)2 = 100 * 30uV/m


7.1   EUT Operation

      Operating Environment:
      Temperature                      : 25.5 °C
      Humidity                         : 52% RH
      Atmospheric Pressure             : 1010 mbar




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E                       Page 10 of 22



7.2   Test Procedure

      a) Test Procedure (below 30MHz)
      (1) The EUT is placed on a turntable, which is 0.8m above ground plane.
      (2) The turntable shall be rotated for 360 degrees to determine the position of maximum emission
          level.
      (3) EUT is set 3m away from the receiving antenna.
      (4) Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
      (5) Repeat above procedures until the measurements for all frequencies are complete.
      (6) The radiation measurements are performed in X,Y,Z axes position(X denotes lying on the table,
          Y denotes side stand and Z denotes vertical stand), the worst is X position.
      (7) New battery used during test.
      (8) A calculated substitution wire ring antenna used during test.

      b) Test Procedure (above 30MHz)
      (1) The EUT is placed on a turntable, which is 0.8m above ground plane.
      (2) The turntable shall be rotated for 360 degrees to determine the position of maximum emission
          level.
      (3) EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the
          maximum emissions.
      (4) Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
      (5) And also, each emission was to be maximized by changing the polarization of receiving antenna
          both horizontal and vertical.
      (6) Repeat above procedures until the measurements for all frequencies are complete.
      (7) The radiation measurements are performed in X,Y,Z axes position(X denotes lying on the table,
          Y denotes side stand and Z denotes vertical stand), the worst is X position.
      (8) New battery used during test.
      (9) A calculated substitution wire ring antenna used during test.




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E                    Page 11 of 22



7.3   Test Setup

      The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site.
      a) Radiated Emission Test Setup, Frequency Below 30MHz




      b) Radiated Emission Test Setup, Frequency range 30MHz ~ 1000MHz




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E                                 Page 12 of 22



7.4   Spectrum Analyzer Setup

      According to FCC Part15 Rules, the system was tested 9kHz to 1000MHz.

                     Below 30MHz:

                     Sweep Speed .....................................................Auto
                     IF Bandwidth        ....................................................10 KHz
                     Video Bandwidth ..................................................10KHz
                     Resolution Bandwidth ..........................................10KHz


                     Above 30MHz:

                     Sweep Speed .....................................................Auto
                     IF Bandwidth        ....................................................120 KHz
                     Video Bandwidth ..................................................100KHz
                     Quasi-Peak Adapter Bandwidth...........................120 KHz
                     Quasi-Peak Adapter Mode...................................Normal
                     Resolution Bandwidth ..........................................120kHz


7.5   Corrected Amplitude & Margin Calculation

      Formula of conversion factors:the field strength at 3m was established by adding the meter reading
      of the spectrum analyzer (which is set to read in units of dBuV/m) to the antenna correction factor
      supplied by the antenna manufacturer. The antenna correction factors are stared in terms of dB.
      The gain of the pressletor was accounted for in the spectrum analyser meter reading.
          Example:
          Freq(MHz) Meter Reading +ACF=FS
           33          20dBuV+10.36dB=30.36dBuV/m @3m




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E          Page 13 of 22



7.6   Test Results
      Test frequency below 30MHz:




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E          Page 14 of 22




    Test frequency above 30MHz
    Test Mode: Working Mode
    Antenna Porlarization: Vertical




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E           Page 15 of 22




    Antenna Porlarization: Horizontal




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E               Page 16 of 22



8     Photographs–Test Setup
8.1   Conducted Emissions




8.2   Photograph – Radiation Emissions Test Setup

                                       Below 30MHz




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E               Page 17 of 22




                                       Above 30MHz




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E          Page 18 of 22



9     Photographs - Constructional Details
9.1   EUT – Appearance View




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E          Page 19 of 22




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E          Page 20 of 22




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E             Page 21 of 22



9.2   EUT – Open View


                                       RF Antenna




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS13S0705883E                   Page 22 of 22




                                       =End of test report==



 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn



Document Created: 2013-09-27 23:02:41
Document Modified: 2013-09-27 23:02:41

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC