Test Report

FCC ID: KE3-3002511

Test Report

Download: PDF
FCCID_1634857

                                 Application for



          US Code Title 47, Part 2, Subpart J, Section 2.947, Certification
                                        Per
Part 15, Subpart C, for Intentional Radiators, Section 15.249, Intentional Radiator
               Operating within the Band 2400 MHz to 2483.5 MHz

                                        And

          US Code Title 47, Part 2, Subpart J, Section 2.902, Verification
                                       Per
Part 15, Subpart B, for Unintentional Radiators, section 15.101, 15.107 and 15.109



                                      For the

                  Model: PetSafe Stance Analyzer Transmitter
                               Model: 300-2511

                                Manufactured by

                           Radio Systems Corporation




                              UST Project: 12-0016
                        Test Date(s): January 24, 26, 2012
                          Issue Date: February 2, 2012




                    3505 Francis Circle Alpharetta, GA 30004
                      PH: 770-740-0717 Fax: 770-740-1508
                             www.ustech-lab.com


                                   Page 1 of 23


I certify that I am authorized to sign for the test facility and that all of the statements in
this report and in the Exhibits attached hereto are true and correct to the best of my
knowledge and belief:


US TECH (Agent Responsible For Test):



By:


Name: Alan Ghasiani

Title:   Consulting Engineer - President

Date:    February 2, 2012




                  This report shall not be reproduced except in full. The results contained
                  in this report are subject to the adequacy and representative character of
                  the sample provided. US Tech NVLAP accreditation does not allow
                  product endorsement by NVLAP or any agency of the U.S. Government.




                        3505 Francis Circle Alpharetta, GA 30004
                          PH: 770-740-0717 Fax: 770-740-1508
                                 www.ustech-lab.com




                                          Page 2 of 23


FCC ID:                                                                 KE3-3002511
IC:                                                                   2721A-3002511
UST Project No.:                                                             12-0016
Date:                                                          February 2, 2012, 2012
Model(s):                                 PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                  Radio Systems Corporation

                       MEASUREMENT/TECHNICAL REPORT


COMPANY NAME:              Radio Systems Corporation

MODEL(S):                  300-2511
FCC ID:                    KE3-3002511
IC:                        2721A-3002511
DATE:                      February 2, 2012



 This report concerns (check one): Original grant X
                             Class II change_____

 Equipment type: Intentional Radiator Operating within 2400-2483.5 MHz


 Deferred grant requested per 47 CFR 0.457(d) (1) (ii)?      yes_____ No X

 If yes, defer until:_________________
                      date


    N.A.    agrees to notify the Commission by  N.A.
                                                date
 of the intended date of announcement of the product so that the grant can be issued
 on that date.



 Report prepared by:

               US Tech
               3505 Francis Circle
               Alpharetta, GA 30004

               Phone Number: (770) 740-0717
               Fax Number:   (770) 740-1508




                                      Page 3 of 23


FCC ID:                                                                     KE3-3002511
IC:                                                                       2721A-3002511
UST Project No.:                                                                 12-0016
Date:                                                              February 2, 2012, 2012
Model(s):                                     PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                      Radio Systems Corporation




                   SUMMARY OF TEST REQUIREMENTS

FCC
Requirement        Title                                                 Disposition


15.205             Restricted Bands                                      Pass
15.207             Intentional Radiator Power Line Conducted             N/A
                   Emissions
15.209             Intentional Radiator Radiated Emissions               Pass
15.249(a)          Fundamental Field Strength                            Pass
15.107             Unintentional Radiator Power Line Conducted           N/A
                   Emissions
15.109             Unintentional Radiator Radiated Emissions             Pass

                           N/A = Not applicable for this unit.




                                      Page 4 of 23


FCC ID:                                                                                       KE3-3002511
IC:                                                                                         2721A-3002511
UST Project No.:                                                                                   12-0016
Date:                                                                                February 2, 2012, 2012
Model(s):                                                       PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                                        Radio Systems Corporation



                                              Table of Contents
1     General Information ........................................................................................ 7
    1.1    Purpose of this Report .............................................................................. 7
    1.2    Product Description ................................................................................... 7
    1.3    Related Submittal(s)/Grant(s) ................................................................... 7
2     Tests and Measurements ............................................................................... 8
    2.1    Configuration of Tested System ................................................................ 8
    2.2    EUT Characterization ................................................................................ 9
    2.3    Test Facility ............................................................................................... 9
    2.4    Test Equipment ......................................................................................... 9
    2.5    Modifications to EUT ............................................................................... 10
    2.6    Measurement Standards (CFR 15.31) .................................................... 11
    2.7    Frequency Range of Radiated Measurements (CFR 15.33) ................... 11
      2.7.1     Frequency Range for Intentional Radiators ................................................. 11
      2.7.2     Frequency Range for Unintentional Radiators ............................................ 11
      2.7.3     Measurement Detector Function and Bandwidth (CFR 15.35).................... 11
    2.8 Antenna Requirement (CFR 15.203) ...................................................... 13
    2.9 Intentional Radiator, Power Line Conducted Emissions (CFR 15.207) ... 14
    2.10 Intentional Radiator, Radiated Emissions (CFR 15.249 (a), (e)) ............. 15
    2.11 Restricted Bands of Operation (CFR 15.205) ......................................... 15
    2.12 20 dB Bandwidth Measurement & Channel Spacing per CFR 15.249,
    99% Occupied Bandwidth (IC RSS 210, A8.1) ................................................ 16
      2.12.1       20 dB Bandwidth Measurements ............................................................. 16
    2.13 Band Edge Measurements (CFR15.249(d))............................................ 19
      2.13.1       High Band Edge ....................................................................................... 19
      2.13.2       Low Band Edge ........................................................................................ 20
    2.14 Unintentional Radiator, Power Conducted Emissions (CFR 15.107) ...... 21
    2.15 Unintentional Radiator, Radiated Emissions (CFR 15.109) .................... 22
    2.16 Measurement Uncertainty ....................................................................... 23
      2.16.1       Conducted Emissions Measurement Uncertainty: ................................... 23
      2.16.2       Radiated Emissions Measurement Uncertainty: ...................................... 23




                                                     Page 5 of 23


FCC ID:                                                                                  KE3-3002511
IC:                                                                                    2721A-3002511
UST Project No.:                                                                              12-0016
Date:                                                                           February 2, 2012, 2012
Model(s):                                                  PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                                   Radio Systems Corporation




                                  List of Tables
Table 1. EUT and Peripherals .............................................................................. 9
Table 2. Test Instruments used for Evaluation. .................................................. 10
Table 3. PetSafe Stance Analyzer, VTH00-13730 Antennas ............................. 13
Table 4. Intentional Conducted Emissions .......................................................... 14
Table 5. Peak Fundamental and Harmonics, (CFR15.249 (a)) .......................... 17
Table 6. Fundamental and Harmonics Avg. Limits, (CFR 15.35(b), 15.249(a)) . 18
Table 7. Power line Conducted Emissions Data, Class B .................................. 21
Table 8. Unintentional Radiator, Peak Radiated Emissions (CFR 15.109) ........ 22


                                             List of Figures

Figure 1. Test Configuration ................................................................................. 8
Figure 2. Transmitter Pulse Width....................................................................... 12
Figure 3. 20 dB -99% Bandwidth ....................................................................... 16
Figure 4. Conducted Band Edge Compliance – High Channel ........................... 19
Figure 5. Conducted Band Edge Compliance – Low Channel ............................ 20


                                          List of Appendices

Appendix          Title

A                 Agency Agreement
B                 Application Forms
C                 Letter of Confidentiality
D                 Equipment Label
E                 Block Diagram(s)
F                 Schematic(s)
G                 Test Configuration Photographs
H                 External Photographs
I                 Internal Photographs
J                 Theory of Operation
K                 User's Manual




                                                Page 6 of 23


FCC ID:                                                                     KE3-3002511
IC:                                                                       2721A-3002511
UST Project No.:                                                                 12-0016
Date:                                                              February 2, 2012, 2012
Model(s):                                     PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                      Radio Systems Corporation

1 General Information

1.1   Purpose of this Report

       This report is prepared as a means of presenting test data to be used by a
Telecom Certification Body in determination of whether this product is permitted
for unlicensed dissemination to the general public according to the FCC Rules
and Regulations for RF Devices Intentional Radiators.

1.2   Product Description

        The PetSafe Stance Analyzer is used by veterinarians to determine the
lameness of a dog by measuring individual paw weight. It consists of three parts.
One is handheld transmitter, Model 300-2511, which is being presented for
certification in this test report; the second is a base platform; and the third device
is a receiver station. All units are separate units. When operating the Stance
Analyzer, a dog is placed on the base platform with its paws placed on four
separate pressure pads. The operator presses a button on the handheld
transmitter which then sends an RF command to the receiver and the receiver
communicates this information to a PC via hardwire connections.

1.3   Related Submittal(s)/Grant(s)

1.3.1 The EUT is subject to the following FCC authorizations:

       a)      Certification under section 15.249 as a transmitter
       b)      Verification under 15.101 as a digital device
       c)      The receiver has been evaluated under Part 15 as a DoC device

1.3.2 Certification of the Transmitter

      The EUT is a low power device which falls within the requirements of
15.249. The bandwidth limitations have also been met. Please see the data
presented herein.

1.3.3 Verification of the Digital apparatus

       The Verification requirement shares many common report elements with
the Certification report. Therefore, though this report is mostly intended to
provide data for the Certification process, the Verification authorization report
(part 15.107 and 109) for the PetSafe Stance Analyzer is included herewith.




                                     Page 7 of 23


FCC ID:                                                                 KE3-3002511
IC:                                                                   2721A-3002511
UST Project No.:                                                             12-0016
Date:                                                          February 2, 2012, 2012
Model(s):                                 PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                  Radio Systems Corporation

2 Tests and Measurements

2.1   Configuration of Tested System

       The sample was setup and tested per ANSI C63.4, Methods of
Measurement from Low-Voltage Electrical and Electronic Equipment in the
Frequency Range of 9 kHz to 40 GHz (2003). Conducted and radiated
emissions data were taken with the EMC test receiver (or spectrum analyzer's)
resolution bandwidth adjusted to 9 kHz and 120 kHz, respectively. All
measurements are peak unless stated otherwise. The video filter associated
with the spectrum analyzer was off throughout the evaluation process. A Block
diagram of the tested system is shown in Figure 1. A listing of the EUT and its
test peripherals is found in Table 1 below. Test configuration photographs for
spurious and fundamental emissions measurements are in the attached
appendices.




      EUT                            2m U USB cable



                              Rx                      Laptop


                                                             3m U power cable




                                                    120VAC/60Hz


                        Figure 1. Test Configuration




                                  Page 8 of 23


FCC ID:                                                                  KE3-3002511
IC:                                                                    2721A-3002511
UST Project No.:                                                              12-0016
Date:                                                           February 2, 2012, 2012
Model(s):                                  PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                   Radio Systems Corporation




Table 1. EUT and Peripherals
  PERIPHERAL            MODEL         SERIAL         FCC ID:          CABLES
 MANUFACTURER          NUMBER         NUMBER                            P/D
        EUT
   Radio Systems
                                                                    2 meter U USB
     Corporation       300-2511         None      KE3-3002511
                                                                        cable
   PetSafe Stance
    Analyzer TX
  Laptop and laptop
                                                                   3 meter U power
    power supply       Think Pad          --            --
                                                                        cable
       Lenovo

2.2   EUT Characterization

      The sample used for testing was received by US Tech on January 24,
2012 in good operating condition.

2.3   Test Facility

        Testing was performed at US Tech's measurement facility at 3505 Francis
Circle, Alpharetta, GA. This site has been fully described and registered with the
FCC under designation number US5117. Additionally this site has also been fully
described and submitted to Industry Canada (IC), and has been approved under
file number 2982A-1.

2.4   Test Equipment

       Table 2 describes test equipment used to evaluate this product.




                                   Page 9 of 23


FCC ID:                                                                     KE3-3002511
IC:                                                                       2721A-3002511
UST Project No.:                                                                 12-0016
Date:                                                              February 2, 2012, 2012
Model(s):                                     PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                      Radio Systems Corporation

Table 2. Test Instruments used for Evaluation.
                                                                          DATE OF
                        MODEL                             SERIAL
 TEST INSTRUMENT                    MANUFACTURER                           LAST
                       NUMBER                             NUMBER
                                                                        CALIBRATION
       SPECTRUM                        HEWLETT-
                         8566B                           2410A00109        11/4/2011
       ANALYZER                        PACKARD
       SPECTRUM                        HEWLETT-
                         8593E                           3205A00124       10/26/2011
       ANALYZER                        PACKARD
                                       HEWLETT-
       RF PREAMP         8447D                           2944A07436        10/6/2011
                                       PACKARD
       BICONICAL
                         3110B            EMCO            9306-1708        4/29/2011
       ANTENNA
                                                                          11/22/2011
      LOG PERIODIC       3146             EMCO            9305-3600
                                                                             2yrs
      LISN (x 2)                                          910495 &
                         8028        Solar Electronics                     1/27/2011
  8028-50-TS24-BNC                                         910494
                                                                           8/10/2011
   HORN ANTENNA          3115             EMCO            9107-3723
                                                                             2 Year

                                       HEWLETT-
        PREAMP           8449B                           3008A00480       11/15/2011
                                       PACKARD

      CALCULATION
                          N/A              N/A             Ver. 6.0           N/A
       PROGRAM


Note: The calibration interval of the above test instruments is 12 months unless stated
      otherwise, and all calibrations are traceable to NIST/USA.

2.5    Modifications to EUT

      No modifications were made by US Tech to bring the EUT into compliance
with FCC Part 15, Subpart B, Class B Limits for the receiver and digital portion of
the EUT or the Subpart C, Transmitter requirements.




                                    Page 10 of 23


FCC ID:                                                                  KE3-3002511
IC:                                                                    2721A-3002511
UST Project No.:                                                              12-0016
Date:                                                           February 2, 2012, 2012
Model(s):                                  PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                   Radio Systems Corporation

2.6   Measurement Standards (CFR 15.31)

       Intentional and unintentional radiators are to use the methods of ANSI
C63.4 – 2003. Measurements were made on an Open Area Test Site (OATS)
wherever possible. For battery powered equipment, new (or fully charged)
batteries are used. Section 15.31(m) indicates that if the EUT System operates
for example at 906 MHz ISM band, measurements must be made near the
bottom of the band (around 902 MHz for example) and near the top of the band
(908 MHz). However this EUT only operates at 2402 MHz therefore only one
channel, 2402 MHz, was evaluated.

2.7   Frequency Range of Radiated Measurements (CFR 15.33)

       The frequency range is detailed below for intentional and unintentional
radiators.

2.7.1 Frequency Range for Intentional Radiators

      The spectrum was investigated from the lowest RF signal generated
without going below 9 kHz to the 10th harmonic of the highest fundamental
transmitter frequency.

2.7.2 Frequency Range for Unintentional Radiators

      The spectrum was investigated from the lowest RF signal generated
without going below the lowest frequency for which an emissions limit is specified
(30 MHz) to the 5th harmonic of the highest fundamental frequency of the digital
device (5 GHz maximum).

2.7.3 Measurement Detector Function and Bandwidth (CFR 15.35)

        On any frequency below 1000 MHz, the limits shown are based upon
measuring equipment employing a CISPR quasi-peak detector function and
related measurement bandwidths. On frequencies above 1000 MHz, the
radiation limits are based upon the use of measuring instrumentation employing
an average detector function.

      When average detector measurements are specified for use, including
emission measurements below 1000 MHz, there is also a corresponding limit for
Peak detector measurements having a limit of 20 dB above the corresponding
average limit unless a different peak emission limit is specified. Measurements
above 1000 MHz utilize a minimum resolution bandwidth of 1 MHz.



                                   Page 11 of 23


FCC ID:                                                                KE3-3002511
IC:                                                                  2721A-3002511
UST Project No.:                                                            12-0016
Date:                                                         February 2, 2012, 2012
Model(s):                                PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                 Radio Systems Corporation

       When radiated emissions limits are expressed in terms of the average
value of the emission and pulsed operation is employed, the measurement field
strength is determined by averaging over one complete pulse train (Duty Cycle)
including blanking intervals for pulse trains up to 0.1 second in duration. The
exact method of calculating the average field strength is included in paragraph
2.11 of this report. Refer to Figures 1 for duty cycle measurement data.




                     Figure 2. Transmitter Pulse Width


                   13.6 mS/100mS = 0.136 = 13.6 percent


                         DC = 20 Log(0.136) = -17.32




                                 Page 12 of 23


FCC ID:                                                                    KE3-3002511
IC:                                                                      2721A-3002511
UST Project No.:                                                                12-0016
Date:                                                             February 2, 2012, 2012
Model(s):                                    PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                     Radio Systems Corporation

2.8    Antenna Requirement (CFR 15.203)

       The intentional radiator is designed to assure that no antenna other than
that furnished by the manufacturer is used with the device. The use of a
permanently attached antenna is considered sufficient to comply with this
requirement. Below is a table of the permanently attached antenna used with this
system and its characteristics. If, in the future, additional antennas are
contemplated for use, they must be formally evaluated and approved for
suitability to these requirements.

Table 3. PetSafe Stance Analyzer TX Antenna
                     Model       Antenna      Frequency      Peak Gain     Impedance
  Manufacturer
                    Number         Type         Range           dBi          Ohms
        Wurth                   Integrated
                                              2400 - 2500
      Electronik   7488910245      chip                         3.0             50
                                                 MHz
        Group                    antenna




                                   Page 13 of 23


FCC ID:                                                                          KE3-3002511
IC:                                                                            2721A-3002511
UST Project No.:                                                                      12-0016
Date:                                                                   February 2, 2012, 2012
Model(s):                                          PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                           Radio Systems Corporation

2.9   Intentional Radiator, Power Line Conducted Emissions (CFR 15.207)

       The EUT is connected to the power lines through the use of the USB
cable to the Laptop computer or other PC. The user is able to interface with the
EUT and is able to set the EUT into a transmit mode will connect to the PC or
Laptop. This configuration is shown in Figure 1 above and is the configuration
used for testing to CFR 15.207. The test data can be seen in Table 4 below.

      The worst-case results for conducted emissions were determined to be
produced when the EUT was operating under continuous transmission on the low
channel.

Table 4. Intentional Conducted Emissions
                        CONDUCTED EMISSIONS 150 kHz to 30 MHz
              Specification Requirement:     Project Manufacturer: Radio Systems
 Tested By:
                  FCC Part 15.207              No.:  Corporation Corp.
    KM
                        Class B              12-0016 Model: 300-2511
 Frequenc                                   Corrected        Avg
              Test Data    LISN+CL-PA                               Margin
     y                                       Results       Limits                  Detector
               (dBuV)          (dB)                                  (dB)
   (MHz)                                     (dBuV)        (dBuV)



          The EUT is powered by a coin cell battery. This test is not applicable.




Test Date: January 24, 2012
Tested By
Signature: ________________                                     Name:   Keyvan Muvahhid




                                           Page 14 of 23


FCC ID:                                                                  KE3-3002511
IC:                                                                    2721A-3002511
UST Project No.:                                                              12-0016
Date:                                                           February 2, 2012, 2012
Model(s):                                  PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                   Radio Systems Corporation

2.10 Intentional Radiator, Radiated Emissions (CFR 15.249 (a), (e))

    The EUT frequency hopping was stopped and it was placed into a continuous
transmit mode of operation. A preliminary scan was performed on the EUT to find
signal frequencies that were caused by the transmitter part of the product and to
obtain the worse case result the EUT tested in all X, Y and Z axis. Radiated
measurements below 1 GHz were tested with a RBW = 120 kHz. Radiated
measurements above 1 GHz were measured using a RBW =1 MHz VBW = 3
MHz. Test data is found in Tables 4 and 5.


2.11 Restricted Bands of Operation (CFR 15.205)

    Only radiated harmonics and other spurious signals can be permitted to fall
into the restricted bands of 15.205. All signals found in paragraph 2.7 above shall
be examined for this requirement. Limits are based upon the limits of paragraph
15.209. Above 1 GHz, the limits are for Average value. See Tables 4 and 5
below for peak and Average measurements. According to CFR 15.35, the peak
limits can exceed the average limits by 20 dB.




                                   Page 15 of 23


FCC ID:                                                                KE3-3002511
IC:                                                                  2721A-3002511
UST Project No.:                                                            12-0016
Date:                                                         February 2, 2012, 2012
Model(s):                                PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                 Radio Systems Corporation

2.12    20 dB Bandwidth Measurement & Channel Spacing per CFR 15.249,
       99% Occupied Bandwidth (IC RSS 210, A8.1)

2.12.1    20 dB Bandwidth Measurements

   The EUT antenna port was connected to a spectrum analyzer having a 50 Ω
input impedance. Measurements were performed similar to the method of FCC,
KDB Publication No. DA 00-705 for a bandwidth of 20 dB. The RBW was set to
approximately 1/100 of the manufacturers claimed RBW and with the VBW ≥
RBW. The results of this test are given in Table 13 and Figures 23 through 25.

   The above method was not possible. The EUT does not have an antenna
port; the test was preformed using the alternate radiated method per KDB
publication No. DA 00-705.

Bandwidth = 537 KHz




                      Figure 3. 20 dB -99% Bandwidth




                                 Page 16 of 23


FCC ID:                                                                         KE3-3002511
IC:                                                                           2721A-3002511
UST Project No.:                                                                     12-0016
Date:                                                                  February 2, 2012, 2012
Model(s):                                         PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                          Radio Systems Corporation

Table 5. Peak Fundamental and Harmonics, (CFR15.249 (a))
                        Radiated Harmonic and Spurious Emissions,
                               Tested from 30 MHz – 24 GHz
 Tested By:   Test: FCC Part 15, Para         Client: Radio Systems Corporation
    KM        15.247(d)
              Project: 12-0016                Model: 300-2511
               Test                 Corrected                             Pass
Frequency              AF+CL-PA                   Limits  Distance /                Detector
               Data                  Results                             Margin
  (MHz)                 (dB/m)                  (dBuV/m) Polarization               PK / AVG
              (dBuV)                (dBuV/m)                              (dB)

 2402.01      81.09      -3.41       77.68       114.0      3.0m./V       36.3        PK
 4804.10      50.48       4.05       55.53        74.0      3.0m./V       18.5        PK
 7205.78      48.85       9.96       50.27        74.0      1.0m./V       23.7        PK

1. (*) Falls within the restricted bands of CFR 15.205. Limits based on CFR15.209 & 20 dB
relaxation of CFR 15.35.
2. ND = No other signals detected within 20 dB of specification limit.
SAMPLE CALCULATION:
3. Measurements taken at 1 meter distance were extrapolated to 3 meter using a factor of (-9.54
dB).
RESULTS: At 2402.01 MHz: = 81.09 dBuV+ -3.41 dBuv/m = 77.68 dBuV/m @ 3m
Margin = (114.0 – 77.68) = 36.3 dB




Test Date: January 24, 26, 2012

Tested By
Signature:________________________ Name:                     Keyvan Muvahhid




                                         Page 17 of 23


FCC ID:                                                                        KE3-3002511
IC:                                                                          2721A-3002511
UST Project No.:                                                                    12-0016
Date:                                                                 February 2, 2012, 2012
Model(s):                                        PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                         Radio Systems Corporation

Table 6. Fundamental and Harmonics Avg. Limits, (CFR 15.35(b), 15.249(a))

                          Radiated Harmonic and Spurious Emissions,
                                  Tested from 30 MHz – 24 GHz
                 Test: FCC Part 15, Para
   Tested By:                                    Client: Radio Systems Corporation
                 15.247(d)
      KM
                 Project: 12-0016                Model: 300-2511
                 Test               Corrected                            Pass
 Frequency               AF+CL-PA               Limits  Distance /                   Detector
                 Data                Results                            Margin
   (MHz)                  (dB/m)              (dBuV/m) Polarization                  PK / AVG
                (dBuV)              (dBuV/m)                             (dB)
  2402.01       81.09      -3.41      60.38      94.0      3.0m./        33.6         AVG
  4804.10       50.48      4.05       38.23      54.0      3.0m./        15.8         AVG
  7205.78       48.85      9.96       32.97      54.0      1.0m./        21.0         AVG

1. (*) Falls within the restricted bands of CFR 15.205.
2. ND = No other emissions detected within 20 dB of the Part 15.209 limits for
spurious emissions within Restricted Bands.
3. Test data values measured at 1 meter include a factor of -9.54 dB for distance
extrapolation from a test distance of 1 meter to 3 meters.
4. Additional factors include a Duty Cycle, DC = -17.3 dB and filter factor of +1.0
dB.
SAMPLE CALCULATION:
RESULTS: At 2402.01 MHz: = (81.09-17.3 DC) + (-3.41) = 60.38 dBuV/m @ 3m
Margin = (94.0 – 60.38) = 33.6 dB

Test Date: January 24, 26, 2012

Tested By
Signature: ________________                                 Name: Keyvan Muvahhid




                                        Page 18 of 23


FCC ID:                                                               KE3-3002511
IC:                                                                 2721A-3002511
UST Project No.:                                                           12-0016
Date:                                                        February 2, 2012, 2012
Model(s):                               PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                Radio Systems Corporation

2.13 Band Edge Measurements (CFR15.249(d))

       The EUT has only one fundamental frequency. Therefore the Band Edge
measurements were made at one frequency. A measurement was made of the
fundamental and the emission was measured using a quasi peak setting. A
Resolution Bandwidth of > 1% of the emission bandwidth was used. This
procedure was repeated for the high side. The limits were derived in the
following sections.

2.13.1 High Band Edge

       Above 906 MHz the limit per section 15.249(d) is 50 db below the
fundamental or the value expressed by CFR 15.209 (46 dBuV/m) whichever is
the lesser attenuation.

The channel fundamental recorded in Table 5 is 77.68 dBuV/m:
77.68 dBuV – 32.80dB = 44.88 dBuV/m
Passing Margin= (50) – 44.88= 5.12 dB




         Figure 4. Conducted Band Edge Compliance – High Channel



                                Page 19 of 23


FCC ID:                                                               KE3-3002511
IC:                                                                 2721A-3002511
UST Project No.:                                                           12-0016
Date:                                                        February 2, 2012, 2012
Model(s):                               PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                Radio Systems Corporation

2.13.2 Low Band Edge

The channel fundamental recorded in Table 5 is 77.68 dBuV/m
77.68 – 40.90 = 36.78 dB
Passing Margin= (50) – 36.78 = 13.22 dB




         Figure 5. Conducted Band Edge Compliance – Low Channel




                                Page 20 of 23


FCC ID:                                                                          KE3-3002511
IC:                                                                            2721A-3002511
UST Project No.:                                                                      12-0016
Date:                                                                   February 2, 2012, 2012
Model(s):                                          PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                           Radio Systems Corporation

2.14 Unintentional Radiator, Power Conducted Emissions (CFR 15.107)

       The EUT is powered by a coin cell battery; this test is not applicable.

       Measurements were made over the 150 kHz to 30 MHz frequency range
for the unit. The measurement receiver was connected to the RF (receiver) Port
on the LISN and each power lead was individually measured. Test results are
shown on Table 7 for the unit.


Table 7. Power line Conducted Emissions Data, Class B
                          CONDUCTED EMISSIONS 150 kHz to 30 MHz
              Specification Requirement:     Project Manufacturer: Radio Systems
 Tested By:
                  FCC Part 15.207              No.:  Corporation Corp.
    KM
                        Class B              12-0016 Model: 300-2511
 Frequenc                                   Corrected        Avg
              Test Data     LISN+CL-PA                              Margin
     y                                       Results       Limits                  Detector
               (dBuV)           (dB)                                 (dB)
   (MHz)                                     (dBuV)        (dBuV)



          The EUT is powered by a coin cell battery. This test is not applicable.




Test Date: January 24,26, 2012

Tested By
Signature: ________________                                     Name:   Keyvan Muvahhid




                                           Page 21 of 23


FCC ID:                                                                         KE3-3002511
IC:                                                                           2721A-3002511
UST Project No.:                                                                     12-0016
Date:                                                                  February 2, 2012, 2012
Model(s):                                         PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                          Radio Systems Corporation

2.15 Unintentional Radiator, Radiated Emissions (CFR 15.109)

    Radiated emissions within the band 30 MHz to 12.5 GHz were measured with
a spectrum analyzer via a pre-amplifier by connecting the spectrum analyzer to a
receiving antenna spaced three (3) meters from the EUT. The spectrum analyzer
was set for a 50 Ω input impedance with the VBW set to > the RBW bandwidth.
The antenna was raised and lowered over a span of 4 meters in order to
maximize the signal coming from the EUT. Similarly, the turntable was rotated
through 360 degrees in the same maximizing effort. Also the EUT was scanned
for a maxima when placed in each of the three mutually exclusive orthogonal
planes. The results of the measurements are given in Table 9.

Table 8. Unintentional Radiator, Peak Radiated Emissions (CFR 15.109)
                          Unintentional Radiator, Radiated Emissions
   Test By:   Test: FCC Part 15.109, 15.209         Client: Radio Systems Corporation
     KM       Project: 12-0016 Class: B             Model: 300-2511
  Frequency   Test Data   AF+CL-PA     Results     Limits    Distance /    Margin DETECTOR
    (MHz)      (dBuV)       (dB)      (dBuV/m)   (dBuV/m)   Polarization    (dB)   PK / QP




    All emissions are greater than 20 dB below the limit and therefore are not reported.




Tested from 30 MHz to 13 GHz.

Test date: January 24, 26, 2012

Tested By
Signature:______________________                 Name:__Keyvan Muvahhid




                                        Page 22 of 23


FCC ID:                                                                   KE3-3002511
IC:                                                                     2721A-3002511
UST Project No.:                                                               12-0016
Date:                                                            February 2, 2012, 2012
Model(s):                                   PetSafe Stance Analyzer TX, Model 300-2511
Customer:                                                    Radio Systems Corporation

2.16 Measurement Uncertainty

       The measurement uncertainties given were calculated using the method
detailed in CISPR 16-4. A coverage factor of k=2 was used to give a level of
confidence of approximately 95%.


2.16.1 Conducted Emissions Measurement Uncertainty:

      Measurement Uncertainty (within a 95% confidence level) for this test is
±2.8 dB.

       This measurement was not applicable to this EUT.

2.16.2 Radiated Emissions Measurement Uncertainty:

      For a measurement distance of 3 m the measurement uncertainty (with a
95% confidence level) for this test using a Biconical Antenna (30 MHz to 200
MHz) is ±5.3 dB. This value includes all elements of measurement.

       The measurement uncertainty (with a 95% confidence level) for this test
using a Log Periodic Antenna (200 MHz to 1000 MHz) is ±5.1 dB.

       The measurement uncertainty (with a 95% confidence level) for this test
using a Horn Antenna is ±5.1 dB.

       The data listed in this test report does have sufficient margin to negate the
effects of uncertainty, therefore, this test is unconditionally acceptable.




                                   Page 23 of 23



Document Created: 2012-02-06 12:07:18
Document Modified: 2012-02-06 12:07:18

© 2024 FCC.report