Users Manual

FCC ID: KDYSR130

Users Manual

Download: PDF
FCCID_2497988

                                                                    SR120 Outdoor



Programming
The following provides instructions on how to program your siren via a keypad or by using BabyWare. For
more details on how to program, please refer to the MG/SP Programming Guide.
                                                                                                                 SR130: Outdoor Wireless Siren w/Built-In Strobe Light
To Program Using a Keypad
     MG6250          MG/SP         Feature                Details
     [0801]          [683]         Learn Siren #1         Press and hold “Reset/Training” switch for 3 seconds
     [0802]          [684]         Learn Siren #2         after entering the section to learn the siren.
     [0803]          [685]         Learn Siren #3         WARNING: When you press the "Reset/Training"
     [0804]          [686]         Learn Siren #4         switch, the SR130 will squawk and the strobe light
                                                          will flash five times to confirm registration to the
                                                          panel.
     [0801]          [687]         Display Signal         Press and hold "Reset/Training" switch for 3 seconds
                                   Strength Siren #1      after entering the section to display, on a K32LCD
     [0802]          [688]         Display Signal         V1.3 or higher, the signal strength the panel is                                                                                            SR130-EI00
                                   Strength Siren #2      receiving from the siren.
     [0803]          [689]         Display Signal                                                                                                                                                     Version 1.0
                                   Strength Siren #3
     [0804]          [690]         Display Signal                                                                                                                                                     Printed in Canada
                                   Strength Siren #4
     [0811]          [691]         Label Siren #1         These labels are used when reporting events via                                                                                             12/2014
     [0812]          [692]         Label Siren #2         e-mail through the IP100/ IP150 (MG/SP only) or
     [0813]          [693]         Label Siren #3         SMS personal reporting (MG6250 only) and for           Description
     [0814]          [694]         Label Siren #4         troubleshooting purposes. Maximum 16 characters.       The SR130 is a stand-alone, fully supervised outdoor wireless siren with built-in strobe light and wireless
     [0800]          [695]         Temporary              Press the [enter] key after entering the section to    transceiver. With normal use, the SR130 will function up to three years without the need to replace the
                                   Tamper Switch          deactivate tamper alarm    until the cover is          batteries. The SR130 uses 2-way wireless communication, which provides continuous supervision between
                                                                               DESIGN
                                   Deactivation for       reinstalled or after 30 minutes.                       the panel and siren with fast response to alarm signals within 4 seconds.The SR130 operates using three
                                   Maintenance                                                                   size “C” alkaline batteries.
     [0820]          [587]         Panel                  OFF = disabled    ON = enabled (default)
                                   Supervision of                                                                Overview
                                   Siren
     Option [1]      Option [3]    Siren #1 (OFF/         The control panel supervises the presence of the
                                   ON)                    SR130. If lost, the control panel will follow global
                                                                                                                                                                         1.     Siren (100dB or more) *
     Option [2]      Option [4]    Siren #2 (OFF/         supervision loss option set in the panel.
                                                                                                                                                                         2.     Wall tamper switch and cover tamper
                                   ON)                                                                                                                                          switch
     Option [3]      Option [5]    Siren #3 (OFF/                                                                                                                        3.     Reset/Training switch
                                   ON)                                                                                                                                   4.     Tamper Switch connector
     Option [4]      Option [6]    Siren #4 (OFF/                                                                                                                        5.     Battery pack (3 size “C” alkaline batteries)
                                   ON)                                                                                                                                   6.     Strobe lights
                                                                                                                                                                         7.     In-Field connector
To Program Using BabyWare                                                                                                                                                8.     Signal Strength and transmission LED
1.      Open BabyWare and connected to your system.                                                                                                                      9.     Antenna
2.      Go to BabyWare => Add Item => Wireless Sirens.                                                                                                                   10.    Status LED
3.      Fill-in the label, location, and serial number of the SR130.                                                                                                     11.    Mounting screw
4.      Click Save.                                                                                                                                                      12.    Captive screw
Certifications                                                                                                                                                           * Warning! High Voltage. Remove batteries
                         EN50131-4 Grade 2, Type W          EN 50130-5 Class IV                                                                                          before maintenance
                                                                                                                                                          Figure 1:ISR130 Back cover
     Certification       Applica Test and Certification
     Body:


LED Feedback                                                                                                     Tamper Supervision
                                                                                                                 If a tamper is detected, the SR130 sounds an alarm and the strobe light flashes for 4 minutes. The control
     Signal strength/RF      Red blinking - sending data                                                         panel follows the global supervision options set in the panel.
     transmission LED        Green blinking - receiving data
                             Amber flash 4x - strong signal
                                                                                                                 Specifications
                             Amber flash 3x - good signal                                                          Power                                          4.5VDC (3 size “C” alkaline batteries)
                             Amber flash 2x - weak signal                                                          Battery life                                   Up to 3 years based on normal use (e.g., 2 alarms per year with strobe for
                             Amber flash 1x - very weak signal (relocate)                                                                                         2.5 hours and 8 squawks per day at an average of 25ºC (77ºF) with default
                             No flash - no signal                                                                                                                 alarm time set to 4 minutes. If the alarm is set for more than 4 minutes, the
                                                                                                                                                                  battery life may be reduced).
     Status LED              Red steady on - powered/normal operation Red slow blink - low battery
                                                                                                                   Current Consumption:                           Standby: 5.75μA
                                                                                                                                                                  Maximum: 450mA
Installation                                                                                                       Battery Low Voltage                            Will be sent at 4.1 VDC
                                                                                                                   signal                                         (This product requires 3 –1.5V batteries total nominal voltage 4.5VDC)
1.      Write down the serial number (on the back of the unit) and location of the SR130 for later reference,
        to insert into BabyWare.                                                                                   * RF frequency                                 433MHz or 868MHz
2.      Unlock the top cover by turning the captive screw.                                                         Siren                                          100dB or more (1 meter)
3.      Remove the top cover from the siren.                                                                                                                      Acoustic output type: Tone
4.      Mount the SR130 siren to the wall using the mounting screws.                                               Dimensions                                     13.43cm X 21.17cm X 5.11cm (5.29in X 8.34in X 2.01in)
5.      Make sure the Anti-Tamper switch is screwed into the wall.
                                                                                                                   Weight                                         567g (20 oz.) with batteries, 365g (12.87oz.) without

Siren with Batteries                                                                                               Humidity Range                                 5% to 93%
                                                                                                                   Operating Temperature                          -25ºC to 70ºC (-13ºF to 158ºF)
                                                                                                                   RF range                                       Up to 70m (230 ft)

                                                                                                                 * Only 433 MHz version is approved for FCC and IC

                                                                                                                 Compatibility
                                            Figure 2:Remove the Cover
If your siren already has batteries installed you need to:                                                         MG/SP series v4.0 or higher (except SP4000)                                        K32LCD v1.3 or higher
   A Remove the plastic tab between the top battery terminals and the battery compartment.                         MG6250 v3.0 and higher                                                             K32LCD+ v1.0 or higher
   B Leave the covers off until you train the siren.                                                               RTX3 v1.5 or higher                                                                K32LX v1.0 or higher
                                                                                                                   BabyWare v2.8 or higher                                                            In-Field Upgrade Software v3.8 or higher
Siren without Batteries
                                                                                                                   K32+ v1.0 or higher                                                                For latest updates visit paradox.com
If your siren does not come with the batteries then:
   A Insert the batteries. Make sure to place with the proper polarity.                                          FCC and Industry Canada Compliance Statement
                                                                                                                 This device complies with FCC Rules Part 15 and with Industry Canada license exempt RSS standard(s). Operation is subject to two conditions:
   B Leave the covers off until you train the siren.                                                             1.This device may not cause harmful interference
6.    Reinstall the PCB cover.                                                                                   2.This device must accept any interference that may be received or that may cause undesired operation.
                                                                                                                 Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
7.    Reinstall the siren cover and lock.                                                                        suivantes :
                                                                                                                 1.l'appareil ne doit pas produire de brouillage, et
                                                                                                                 2.l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Upgrading Firmware                                                                                               FCC ID: KDYSR130
                                                                                                                 IC: 2438A-SR130
                                                                                                                 FCC WARNING
The SR130 firmware can be upgraded through In-Field (V3.0 or higher) using the 307USB Direct Connect             This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
                                                                                                                 reasonable protection against harmful interference in a residential installation.
Interface.                                                                                                       This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference
                                                                                                                 to radio communications.
     Notes: a. The SR130 needs the batteries installed to upgrade the firmware.                                  However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
                                                                                                                 reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
            b. Ensure that the SR130 Wireless Siren is awake before beginning the firmware upgrade. To           measures:
                                                                                                                 • Reorient or relocate the receiving antenna.
               wake up the siren, press the training/reset switch. The siren will provide you with a 60 second   • Increase the separation between the equipment and the receiver.
                                                                                                                 • Connect the equipment into an outlet different from that to which the receiver is connected.
               delay in order to begin the update.                                                               • Consult the dealer or an experienced radio/TV technician for help.
                                                                                                                 Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Paradox Security Systems Ltd.) could void the user’s
1.      Remove the front cover see Figure 2.                                                                     authority to operate the equipment.

2.      Connect the 307USB to the In-Field connector (connector #8 in Figure 1).                                 Warranty
                                                                                                                 For complete warranty information on this product, please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. The terms
3.      Refer to the firmware upgrade instructions found at: www.paradox.com                                     and conditions are subject to change without notice, from time to time, at Paradox’s sole discretion. We invite you to visit our website on a regular basis for the
        =>Software => In-Field Firmware Upgrade Instructions.                                                    latest Limited Warranty Statement. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions. Please ensure that your use of
                                                                                                                 the Paradox product is in compliance with local, national, and international laws.
                                                                                                                 © 2014 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. US, Canadian and international patents may apply.
                                                                                                                 BabyWare and Paradox are a trademarks or registered trademarks of Paradox Security Systems (Bahamas) Ltd. or its affiliates in Canada, the United States and/or
                                                                                                                 other countries.



Document Created: 2015-01-04 09:00:41
Document Modified: 2015-01-04 09:00:41

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC