MPE Test Report

FCC ID: KBCT5200RIM801D

RF Exposure Info

Download: PDF
FCCID_126366

CELLTECH RESEARCH INC.                                                               Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________



                             CERTIFICATE OF COMPLIANCE
                                  MPE EVALUATION

Test Lab:                                                    Applicant Name:

CELLTECH RESEARCH INC.                                       ITRONIX CORPORATION
Testing and Engineering Lab                                  801 South Stevens Street
1955 Moss Court                                              Spokane, WA 99204
Kelowna, B.C.                                                Attn: Fred Phillips, Certification Engineer
Canada V1Y 9L3                                               Phone: 509-742-1506
Phone:     250 - 860-3130                                    Fax:      509-626-4204
Fax:       250 - 860-3110
Toll Free: 1-877-545-6287
e-mail:    celltech@globuswireless.com
web site: www.globuswireless.com


      FCC ID:               KBCT5200RIM801D
      Model(s):             T5200
      Equipment Type:       Rugged Laptop PC with RIM 801D ARDIS Radio Modem,
                            Vehicle Cradle, & Unity Gain Magnetic Mount Antenna
      Tx Frequency Range: 806 - 825 MHz
      Rx Frequency Range: 851 - 870 MHz
      Max. RF Output Power: 1.2 Watts
      FCC Rule Part(s):     2.1091; 1.1310; ET Docket 93-62

This wireless device has been shown to be compliant for localized maximum permissible exposure
(MPE) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std.
C95.1-1992 and had been tested in accordance with the measurement procedures specified in
ANSI/IEEE Std. C95.3-1999.

I attest to the accuracy of data. All measurements were performed by me or were made under my
supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the
completeness of these measurements and vouch for the qualifications of all persons taking them.

Celltech Research Inc. certifies that no party to this application has been denied FCC benefits pursuant to Section 5301 of
the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a).




Shawn McMillen
General Manager
Celltech Research Inc.


© 2000 Celltech Research Inc.


CELLTECH RESEARCH INC.                                                Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________




                                 TABLE OF CONTENTS


    1.0        INTRODUCTION…………………………………………………………                                                1

    2.0        DESCRIPTION OF EUT………..………………………..………………                                          1

    3.0        MPE MEASUREMENT GUIDELINES.………………………………...                                        2

    4.0        DEFINITION...….…………………………………………………………                                             2

    5.0        MPE LIMITS……………………………..……………………………….                                             3-4

    6.0        DETAILS OF MPE EVALUATION…………………………………….                                          5

    7.0        MPE EVALUATION SUMMARY…..…………………………………..                                         6-8

    8.0        SYSTEM CALIBATION………………………………………………....                                           9

    9.0        SYSTEM SPECIFICATIONS.…………………………………………...                                         9

    10.0       REFERENCES…………………………………………………………….                                                9

    APPENDIX A - MPE TEST SETUP PHOTOGRAPHS……….….…………….                                         10
    APPENDIX B - VEHICLE ANTENNA SPECIFICATIONS…………………...                                       11




© 2000 Celltech Research Inc.


CELLTECH RESEARCH INC.                                                Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


SCOPE
Environmental evaluation measurements of Maximum Permissible Exposure (MPE) to radio
frequency (RF) radiation from transmitting devices for compliance with the technical rules and
regulations of the U.S. Federal Communications Commission (1).


1.0 INTRODUCTION

This measurement report describes the Maximum Permissible Exposure (MPE) tests of Itronix
Model: T5200 Rugged Laptop PC with RIM 801D ARDIS Radio Modem (FCC ID:
KBCT5200RIM801D) and vehicle cradle loaded with a unity gain vehicle rooftop magnetic
mount antenna. The test procedures described in FCC CFR47 2.1091, 1.1310, American
National Standards Institute C95.1-1992 (2), C95.3-1992 (3), and OET Bulletin 65 (Edition 97-
01)(4) were employed. A description of the product and operating configuration, detailed
summary of the test results, methodology and procedures used in the evaluation, equipment used,
and the various provisions of the rules are included within this test report.


2.0 DESCRIPTION of Equipment Under Test (EUT)

                              Rugged Laptop PC
                            with RIM 801D ARDIS
                                                                            Licensed Non-Broadcast
       EUT Type             Radio Modem, Vehicle     Equipment Class
                                                                            Station Transmitter (TNB)
                             Cradle, & Unity Gain
                             Mag-Mount Antenna
                                   RIM 801D
       Radio Type                                         FCC ID             KBCT5200RIM801D
                                (ARDIS Network)

       Max. RF
                                    1.2 Watts          Model No.(s)                  T5200
     Output Power

     Tx Frequency                                        Signal
                                    806 - 825                                         FSK
     Range (MHz)                                       Modulation(s)

                                                                                 Unity Gain
     Rx Frequency
                                    851 - 870          Antenna Type            Vehicle Rooftop
     Range (MHz)
                                                                               Magnetic Mount




© 2000 Celltech Research Inc.       ITRONIX T5200 FCC ID: KBCT5200RIM801D                               1
                                Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                                Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


3.0 MPE MEASUREMENT GUIDELINES

The Federal Communications Commission (FCC) has adopted the guidelines for evaluating the
environmental effects of radio frequency radiation in ET Docket 93-62 on August 6, 1996 to
protect the public from the potential hazards of RF emissions (1). The safety limits used for the
environmental evaluation measurements are based on the criteria published by the American
National Standards Institute (ANSI) for localized MPE in IEEE/ANSI C95.1-1992 Standard for
Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3
kHz – 300 GHz (2). The measurement procedure described in IEEE/ANSI C95.3-1992
Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields –
RF and Microwave (3) is used for guidance in measuring MPE due to RF exposure from the
particular transmitting device. The new guidelines incorporate limits for MPE in terms of
electric and magnetic field strength, and power density for transmitters operating at frequencies
between 300 kHz and 100 GHz. This criteria for MPE evaluation is also described in OET
Bulletin 65 (Edition 97-01), Evaluation Compliance with FCC Guidelines for Human Exposure
to Radio Frequency Electromagnetic Fields (4).

4.0 DEFINITION

MPE is the rms and peak electric and magnetic field strength, their squares, or the plane-wave
equivalent power densities associated with these fields to which a person may be exposed
without harmful effect, and with an acceptable safety factor.

The MPE prescribed by the standard are set in terms of different parameters of effects,
depending on the frequency generated by the device. The MPE levels are set in terms of power
density, whose definition and relationship to electric and magnetic field strengths are described
by the following equation:


                   S(mW / cm2) =       E2 = 37.7H2
                                      3770

where:

         S = Power density (mW/cm2)
         Power per unit area normal to the direction of propagation usually expressed in units of
         watts per square meter (W/m2), or units of milliwatts per square centimeter (mW/cm2).
         For plane waves, power density, electric field strength (E), and magnetic field strength
         (H) are related by the impedence of free space (377 Ω).

         E = Electric field strength (V/m)

         H = Magnetic field strength (A/m)



© 2000 Celltech Research Inc.       ITRONIX T5200 FCC ID: KBCT5200RIM801D                             2
                                Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                                Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


5.0 MPE LIMITS




© 2000 Celltech Research Inc.       ITRONIX T5200 FCC ID: KBCT5200RIM801D                             3
                                Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                                Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________




© 2000 Celltech Research Inc.       ITRONIX T5200 FCC ID: KBCT5200RIM801D                             4
                                Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                                Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


6.0 DETAILS OF MPE EVALUATION

The Itronix T5200 Rugged Laptop PC with RIM 801D ARDIS Radio Modem (FCC ID:
KBCT5200RIM801D) and vehicle cradle loaded with a unity gain vehicle rooftop magnetic
mount antenna was found to be compliant for MPE based on the following test provisions and
conditions:

1) The probe was positioned above a simulated metal vehicle rooftop at a separation distance of
   20.0cm from the radiating antenna and at a starting height of 5.0cm to the center of the probe.
2) The turntable was positioned so that the initial start angle was 0 degrees.
3) The EUT was turned on to allow for sufficient time for stabilization. The EUT was operated
   at full power on a desired frequency.
4) The Survey Meter was set for maximum hold and on the appropriate power range.
5) The turntable was rotated about 360 degrees and the maximum reading was obtained for that
   elevation.
6) The EUT was then turned off and the probe raised by 5.0cm. This process was repeated to a
   sufficient distance past the tip of the antenna or where the maximum radiation was reduced
   by a significant factor to warrant no further measurement. The data was then tabulated and
   graphed in the charts and tables shown on next pages.




                                                                4cm spacing




                                               MPE Test Setup




© 2000 Celltech Research Inc.       ITRONIX T5200 FCC ID: KBCT5200RIM801D                             5
                                Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                                             Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


7.0 MPE MEASUREMENT SUMMARY

The measurement results were obtained with the EUT tested in the conditions described in this
report.

    806MHz

   Height Above         Measured Power                 Correction            Total E-Field           MPE Limit
   Ground Plane         Density at 20cm              Factor to Obtain         Equivalent             (mW/cm2)
       (cm)               (mW/cm2)                   Actual mW/cm2           Power Density

           5                         0.02                    1.06                      0.0212         f/1500

          10                         0.06                    1.06                      0.0636         f/1500

          15                         0.09                    1.06                      0.0954         f/1500

          20                         0.12                    1.06                      0.1272         f/1500

          25                         0.13                    1.06                      0.1378         f/1500

          30                         0.13                    1.06                      0.1378         f/1500

          35                         0.11                    1.06                      0.1166         f/1500

          40                         0.06                    1.06                      0.636          f/1500

          45                         0.03                    1.06                      0.0318         f/1500



                        0.14
                        0.12
                         0.1
    Measured Power 0.08
        Density
       (mW/cm2)    0.06
                   0.04
                        0.02
                           0
                                0           10          20          30            40            50
                                                 Height Above Ground Plane (cm)




© 2000 Celltech Research Inc.           ITRONIX T5200 FCC ID: KBCT5200RIM801D                                    6
                                    Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                                             Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________




    815MHz


   Height Above         Measured Power                 Correction            Total E-Field           MPE Limit
   Ground Plane         Density at 20cm              Factor to Obtain         Equivalent             (mW/cm2)
       (cm)               (mW/cm2)                   Actual mW/cm2           Power Density

           5                         0.03                    1.055                     0.03165        f/1500

          10                         0.05                    1.055                     0.05275        f/1500

          15                         0.08                    1.055                     0.0844         f/1500

          20                         0.11                    1.055                     0.11605        f/1500

          25                         0.14                    1.055                     0.1477         f/1500

          30                         0.13                    1.055                     0.13715        f/1500

          35                         0.10                    1.055                     0.1055         f/1500

          40                         0.07                    1.055                     0.07385        f/1500

          45                         0.04                    1.055                     0.0422         f/1500




                        0.16
                        0.14
                        0.12
    Measured Power  0.1
        Density    0.08
       (mW/cm2)    0.06
                        0.04
                        0.02
                           0
                                0           10          20           30           40            50
                                                 Height Above Ground Plane (cm)




© 2000 Celltech Research Inc.           ITRONIX T5200 FCC ID: KBCT5200RIM801D                                    7
                                    Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                                             Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________




    821MHz


   Height Above         Measured Power                 Correction            Total E-Field           MPE Limit
   Ground Plane         Density at 20cm              Factor to Obtain         Equivalent             (mW/cm2)
       (cm)               (mW/cm2)                   Actual mW/cm2           Power Density

           5                         0.02                    1.05                      0.021          f/1500

          10                         0.05                    1.05                      0.0525         f/1500

          15                         0.07                    1.05                      0.0735         f/1500

          20                         0.09                    1.05                      0.0945         f/1500

          25                         0.10                    1.05                      0.105          f/1500

          30                         0.12                    1.05                      0.126          f/1500

          35                         0.09                    1.05                      0.0945         f/1500

          40                         0.06                    1.05                      0.063          f/1500

          45                         0.04                    1.05                      0.042          f/1500



                        0.14
                        0.12
                         0.1
    Measured Power 0.08
       Density
      (mW/cm )
              2    0.06
                        0.04
                        0.02
                           0
                                0           10          20          30            40            50
                                                 Height Above Ground Plane (cm)




© 2000 Celltech Research Inc.           ITRONIX T5200 FCC ID: KBCT5200RIM801D                                    8
                                    Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                                Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


8.0 SYSTEM CALIBRATION

Prior to the assessment for MPE, the Electromagnetic Radiation Survey Meter and probe was
calibrated as per the operating instructions in the operations manual. The unit was placed into
the units electrically sealed storage case and allowed sufficient time for both units to acquire the
same temperature. The system was then calibrated by a built in software routine and zeroed in
an electromagnetic free environment


9.0 MPE SYSTEM SPECIFICATIONS

Radiation Detection Specifications
      Electromagnetic Radiation Survey Meter:                   Narda Model 8712
      Isotropic Electric Field Probe:                           Model 8761D
      Frequency Range:                                          300 kHz - 3 GHz

Positioning System
         Multi-Device Controller EMCO 2090                      S/N: 9912-1484
         Mini-Mast                  EMCO 2075                   S/N: 0001-2277
         Turntable                  EMCO 2080-1.2/1.5           S/N: 0002-1002




10.0 REFERENCES

    (1) Federal Communications Commission, ET Docket 93-62, Guidelines for Evaluating the
        Environmental Effects of Radiofrequency Radiation, Aug. 1996.

    (2) ANSI/IEEE C95.1-1992, IEEE Standard for Safety Levels with Respect to Human
        Exposure to Radio Frequency Electromagnetic Fields, 3kHz to 300GHz.

    (3) ANSI/IEEE C95.3-1992, IEEE Recommended Practice for the Measurement of
        Potentially Hazardous Electromagnetic Fields – RF and Microwave.

    (4) OET Bulletin 65 (Edition 97-01), Evaluation Compliance with FCC Guidelines for
        Human Exposure to Radio Frequency Electromagnetic Fields.




© 2000 Celltech Research Inc.       ITRONIX T5200 FCC ID: KBCT5200RIM801D                             9
                                Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                                Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna,                                          Dates of Tests: October 24-27, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


APPENDIX A - MPE TEST SETUP PHOTOGRAPHS




© 2000 Celltech Research Inc.       ITRONIX T5200 FCC ID: KBCT5200RIM801D                            10
                                Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                        Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna                                   Dates of Tests: October 24-27, 2000
B.C. CANADA V1Y 9L3


                             MPE TEST SETUP PHOTOGRAPHS
                            UNITY GAIN MAG-MOUNT ANTENNA




© 2000 Celltech Research Inc.       ITRONIX T5200 FCC ID: KBCT5200RIM801D
                                Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                        Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna                                   Dates of Tests: October 24-27, 2000
B.C. CANADA V1Y 9L3


                             MPE TEST SETUP PHOTOGRAPHS
                            UNITY GAIN MAG-MOUNT ANTENNA




© 2000 Celltech Research Inc.       ITRONIX T5200 FCC ID: KBCT5200RIM801D
                                Rugged Laptop PC with RIM 801D ARDIS Radio Modem


CELLTECH RESEARCH INC.                                        Test Report S/N: 101600-32KBC
1955 Moss Court, Kelowna                                   Dates of Tests: October 24-27, 2000
B.C. CANADA V1Y 9L3


                             MPE TEST SETUP PHOTOGRAPHS
                            UNITY GAIN MAG-MOUNT ANTENNA




© 2000 Celltech Research Inc.       ITRONIX T5200 FCC ID: KBCT5200RIM801D
                                Rugged Laptop PC with RIM 801D ARDIS Radio Modem