RF Exposure 2

FCC ID: KBCIX600-EM5625

RF Exposure Info

Download: PDF
FCCID_621190

 Applicant: Itronix, Corporation        FCC ID: KBCIX600-EM5625, KBCIX600-BT, KBCIX600-IWL & KBCIX600-IWLBT


Compliance with 47 CFR 15.247(i)
                “Systems operating under the provisions of this section shall be operated in a manner
                that ensures that the public is not exposed to radio frequency energy levels in excess of
                the Commission's guidelines. See § 1.1307(b)(1) of this chapter.”

The EUT will only be used with a separation distance of 20 centimeters or greater between the antenna and the body of
the user or nearby persons and can therefore be considered a mobile transmitter per 47 CFR 2.1091 (b). Calculations
are provided for each radio transmitting through its own internal antenna and optional external antenna.

The total transmit power is less than 1.5 W (ERP), therefore the EUT is categorically excluded from routine environmental
evaluation per 47 CFR 2.1091(c).

The MPE estimates are as follows:

Table 1 in 47 CFR 1.1310 defines the maximum permissible exposure (MPE) for the general population. The exposure
level at a 20 cm distance from the EUT’s transmitting antenna is calculated using the general equation:

                S = (PG)/4πR2
                Where: S = power density (mW/cm2)
                P = power input to the antenna (mW)
                G = numeric power gain relative to an isotropic radiator
                R = distance to the center of the radiation of the antenna (20 cm = limit for MPE estimates)
                PG = EIRP

Solving for S, the maximum power densities 20 cm from the transmitting antennas are summarized in the tables on the
following pages:




                                                                                                                        1


 Applicant: Itronix, Corporation           FCC ID: KBCIX600-EM5625, KBCIX600-BT, KBCIX600-IWL & KBCIX600-IWLBT




MPE Estimates for Self Located Device

FCC ID: KBCIX600-EM5625

CDMA

                                                                                                                       Ratio of
                                                                                                          General
                                                         Max Peak                Minimum                               Power
                                                                                              Power      Population
                                              Transmit   Conducted    Antenna    Antenna                               Density
   Antenna Type         Antenna Part No.                                                     Density     Exposure
                                             Frequency    Output       Gain       Cable                                 to the
                                                                                             @ 20 cm     Limit from
                                                           Power                   Loss                               Exposure
                                                                                                           1.1310
                                                                                                                         Limit
                                               (MHz)        (mW)        (dBi)       (dB)     (mW/cm2)    (mW/cm2)
Internal Skycross WAN      59-0479-001         1880        724.44       -0.3       1.76       0.090          1            0.090
Internal Skycross WAN     59-0479-001          824.7       792.5         3.8       0.89       0.308         0.55          0.560
External MaxRad         BMLPVDB800/1900        1880        724.44         3        4.61       0.099          1            0.099
External MaxRad         BMLPVDB800/1900        824.7       792.5          3        2.45       0.179         0.55          0.325

Worst Case Ratio of Power Density to the
Exposure Limit = 0.56




Excerpts from TCB Training, April 3, 2002, “Mobile Transmitters”, Slide 6:

        “Devices operating in multiple frequency bands

            ‰   When RF exposure evaluation is required for TCB approval
                   o Separate antennas – estimated minimum separation distances may be considered for the
                      frequency bands that do not require evaluation or TCB approval, however, the estimated distance
                      should take into account the effect of co-located transmitters. (Note 24)

                         Note 24 According to multiple frequency exposure criteria, the ratio of field strength or power
                         density to the applicable exposure limit at the exposure location should be determined for each
                         transmitter and the sum of these ratios must not exceed 1.0 for the location to be compliant.”


The sum of the ratio(s) (power density to the exposure limit) does not exceed 1.0; therefore, the exposure condition is
compliant with FCC rules.




                                                                                                                           2


      Applicant: Itronix, Corporation    FCC ID: KBCIX600-EM5625, KBCIX600-BT, KBCIX600-IWL & KBCIX600-IWLBT




MPE Estimates for Co-located Device


FCC ID: KBCIX600-IWL or KBCIX600-IWLBT

IEEE 802.11 (a) (b) g)

                                                                                                     Ratio of
                                                                                        General
                                          Max Peak                 Minimum   Power                   Power
                                                                                       Population
 Antenna     Antenna Part     Transmit    Conducted    Antenna     Antenna   Density                Density to
                                                                                       Exposure
  Type           No.         Frequency     Output       Gain        Cable     @ 20                     the
                                                                                       Limit from
                                           Power                     Loss      cm                   Exposure
                                                                                        1.1310
                                                                                                      Limit
                                                                             (mW/c
                                (MHz)       (mW)         (dBi)      (dB)      m2)      (mW/cm2)


PiFa MAIN 25.90215.001        5320         100.69         2.26        0       0.034        1          0.034
PiFa MAIN 25.90215.001        2462          92.9          2.41        0       0.032        1          0.032
Worst Case Ratio of Power Density to the Exposure Limit = 0.034




FCC ID: KBCIX600-BT or KBCIX600-IWLBT

Bluetooth Radio

                                                                                                     Ratio of
                                                                                        General
                                          Max Peak                 Minimum   Power                   Power
                                                                                       Population
 Antenna       Antenna        Transmit    Conducted    Antenna     Antenna   Density                 Density
                                                                                       Exposure
  Type         Part No.      Frequency     Output       Gain        Cable     @ 20                    to the
                                                                                       Limit from
                                           Power                     Loss      cm                   Exposure
                                                                                        1.1310
                                                                                                       Limit
                                                                             (mW/c
                               (MHz)        (mW)         (dBi)      (dB)     m2)       (mW/cm2)
Etenna's
AccuWave       EA2400           2402        0.85          3           0      0.0003            1       0.0003

Worst Case Ratio of Power Density to the Exposure Limit = 0.0003




                                                                                                                 3


Applicant: Itronix, Corporation      FCC ID: KBCIX600-EM5625, KBCIX600-BT, KBCIX600-IWL & KBCIX600-IWLBT




Per Note 24 shown below, the Sum of Worst Case Power Ratios cannot exceed 1.0

                    802.11a
                     Radio
  EM5625                                              Sum of Worst
                   Worst Case       Bluetooth
CDMA Radio                                             Case Ratios     FCC Limit
                     Ratio of      Worst Case
 Worst Case                                              (Power        for Sum of
                     Power        Ratio of Power
Ratio of Power                                        Density to the   Worst Case
                   Density to     Density to the
Density to the                                          Exposure         Ratios
                       the        Exposure Limit
Exposure Limit                                            Limit)
                    Exposure
                      Limit
     0.560            0.034            0.0003                 0.5943            1.0      PASS




                                                                                                     4



Document Created: 2006-01-17 18:30:26
Document Modified: 2006-01-17 18:30:26

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC