Calibration Laboratory of                                                                                          Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                                   Service suisse d‘étaionnage
  Engineering AG                                                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                       Swiss Calibration Service



Accredited by the Swiss Federal Office of Metrology and Accreditation
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client       Celltech Labs .. _

                                           TIFICA]
 Object                                             SSN:1387
 Calibration procedure(s)                               1.v5 .       o     e
                                                   ion procedure fordosi


 Calibration date:


 Condition of the calibrated item



 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                      ID #                      Cal Date (Calibrated by, Certificate No.)               Scheduled Calibration
 Power meter E4419B                     GB41293874                5—May—04 (METAS, No. 251—00388)                         May—05
 Power sensor E4412A                    MY41495277                5—May—04 (METAS, No. 251—00388)                         May—05
 Reference 3 dB Attenuator              SN: $5054 (3c)            10—Aug—04 (METAS, No. 251—00403)                        Aug—05
 Reference 20 dB Attenuator             SN: $5086 (20b)           3—May—04 (METAS, No. 251—00389)                         May—05
 Reference 30 dB Attenuator             SN: $5129 (30b)           10—Aug—04 (METAS, No. 251—00404)                        Aug—05
 Reference Probe ES3DV2                 SN: 3013                  7—Jan—05 (SPEAG, No. ES3—3013_JanO05)                   Jan—06
 DAE4                                   SN: 617                   19—Jan—05 (SPEAG, No. DAE4—617_Jan05)                   Jan—06

 Secondary Standards                    ID #                      Check Date (in house)                                   Scheduled Check
 Power sensor HP 8481A                  MY41092180                18—Sep—02 (SPEAG, in house check Oct—03)                in house check: Oct 05
 RF generator HP 8648C                  US3642U01700              4—Aug—99 (SPEAG, in house check Dec—03)                 In house check: Dec—05
 Network Analyzer HP 8753E              US37390585                18—Oct—01 (SPEAG, in house check Nov—04)                in house check: Nov 05


                                        Name                                    Function      ol                          Signature
 Calibrated by:                         Nico Vetterli                             ibe   m     e ‘Micién onl           ;        y



 Approved by:                           Katia Puka\g'                                      i Manager—


                                                                                                                          Issued: March 18, 2005
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.


Certificate No: ET3—1387_MarO5                                           Page 1 of 9


Calibration Laboratory of                                                           Schweizerischer Kalibrierdienst
Schmid & Partner                                                                    Service suisse d‘étalonnage
  Engineering AG                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                        Swiss Calibration Service


Accredited by the Swiss Federal Office of Metrology and Accreditation            Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates



Glossary:
TSL                          tissue simulating liquid
NORMx,y.z                    sensitivity in free space
ConF                         sensitivity in TSL / NORMx,y,z
DCP                          diode compression point
Polarization q               q rotation around probe axis
Polarization 8               8 rotation around an axis that is in the plane normal to probe axis (at
                             measurement center), iie., 8 = 0 is normal to probe axis

Calibration is Performed According to the Following Standards:
   a) IEEE Std 1528—2003, "IEEE Recommended Practice for Determining the Peak Spatial—
      Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
      Communications Devices: Measurement Techniques", December 2003
   b) CENELEC EN 50361, "Basic standard for the measurement of Specific Absorption Rate
      related to human exposure to electromagnetic fields from mobile phones (300 MHz — 3
      GHz), July 2001

Methods Applied and Interpretation of Parameters:
     NORMx,y,z: Assessed for E—field polarization 8 = 0 (f < 900 MHz in TEM—cell; f > 1800 MHz:
     R22 waveguide). NORMx,y,z are only intermediate values, i.e., the uncertainties of
     NORMx,y,z does not effect the E"—field uncertainty inside TSL (see below ConvF).
         NORM(Px,y,z = NORMx,y,z * frequency_response (see Frequency Response Chart). This
         linearization is implemented in DASY4 software versions later than 4.2. The uncertainty of
         the frequency response is included in the stated uncertainty of ConvF.
         DCPx,y,z: DCP are numerical linearization parameters assessed based on the data of
         power sweep (no uncertainty required). DCP does not depend on frequency nor media.
         ConvF and Boundary Effect Parameters: Assessed in flat phantom using E—field (or
         Temperature Transfer Standard for f < 800 MHz) and inside waveguide using analytical field
         distributions based on power measurements for f > 800 MHz. The same setups are used for
         assessment of the parameters applied for boundary compensation (alpha, depth) of which
         typical uncertainty values are given. These parameters are used in DASY4 software to
         improve probe accuracy close to the boundary. The sensitivity in TSL corresponds to
         NORMx,y,z * ConvF whereby the uncertainty corresponds to that given for ConvF. A
         frequency dependent ConvF is used in DASY version 4.4 and higher which allows
         extending the validity from + 50 MHz to + 100 MHz.
         Spherical isotropy (3D deviation from isotropy): in a field of low gradients realized using a
         flat phantom exposed by a patch antenna.
         Sensor Offset: The sensor offset corresponds to the offset of virtual measurement center
         from the probe tip (on probe axis). No tolerance required.


Certificate No: ET3—1387_MarO5                                   Page 2 of 9


    ET3DV6 SN:1387                                                                March 18, 2005




                        Probe ET3DVGO

                                            SN:1387
                                 Manufactured:                   September 21, 1999
                                 Last calibrated:                March 18, 2004
                                 Recalibrated:                   March 18, 2005

                                     Calibrated for DASY Systems
                                      (Note: non—compatible with DASY2 system!)




Certificate No: ET3—1387_Mar05                   Page 3 of 9


    ET3DV6 SN:1387                                                                                           March 18, 2005


    DASY — Parameters of Probe: ET3DV6 SN:1387


    Sensitivity in Free SpaceA                                                                Diode CompressionB

              NormX                      1.61 £101%                 uV/(V/im)                DCP x           92 mV
              NormY                      1.70 £101%                 uV/(V/im)                DCP Y           92 mV
              NormzZ                     1.70 £101%                 uV/(V/im)                DCP Z           92 mV


    Sensitivity in Tissue Simulating Liquid (Conversion Factors)
    Please see Page 8.



    Boundary Effect

   TSL                        900 MHz           Typical SAR gradient: 5 % per mm


              Sensor Center to Phantom Surface Distance                                      3.7 mm 4.7 mm
              SARpe [%]             Without Correction Algorithm                                9.4    4.9
              SARp, [%]             With Correction Aigorithm                                   0.1    0.3


   TSL                      1810 MHz            Typical SAR gradient: 10 % per mm


              Sensor Center to Phantom Surface Distance                                      3.7 mm —4.7 mm
              SARp, [%])            Without Correction Algorithm                                14.3   9.6
              SARp, [%]             With Correction Algorithm                                   0.6    0.1



    Sensor Offset

              Probe Tip to Sensor Center                                                2.7 mm




    The reported uncertainty of measurement is stated as the standard uncertainty of
    measurement multiplied by the coverage factor k=2, which for a normal distribution
    corresponds to a coverage probability of approximately 95%.


   * The uncertainties of NormX,Y,Z do not affect the E—field uncertainty inside TSL (see Page 8).
   ® Numerical linearization parameter: uncertainty not required.




Certificate No: ET3—1387_Mar05                                Page 4 of 9


    ET3DV6 SN:1387                                                                                            March 18, 2005



                                                      Frequency Response of E—Field
                                                            (TEM—Cell:ifi110 EXX, Waveguide: R22)




                                 1.3
               Frequency response (normalized)
                                          us
                                          ho




                                                     |
                                                     |
                                   as




                                                 }
                                                 |
                                                 |

                                                 |
                                                      |
                 $     2
                       to   5&




                                                                          |
                             2
                             R




                                                                         es t_
                             :




                                                                              ——4
                                                 0        500     1000         1500    2000      2500       3000
                                                                          f [MHz]




                                                     Uncertainty of Frequency Response of E—field: £ 6.3% (k=2)




Certificate No: ET3—1387_Mar05                                           Page 5 of 9


   ET3DV6 SN:1387                                                                                    March 18, 2005



                                         Receiving Pattern (¢), 8 = 0°

                   f= 600 MHz, TEM ifi110EXX




                                                                   |        —@—X   —@—¥       —@—Z        —O—Tot




                                                                                                                      |
   |                                                                                                     —0—30 MHz
           a                                                                                             —=— 100 MHz. |
           3.                                                                                            —6—600 MHz | |
           5                                                                             11 T907         Am— 1800 MHz |
           8 54 COCCCCCCCEC—ESEenceaecece 1CACAAEAZT |—a—zsvomee] |
                806       |—B——H————AAA—AABAAAAHAAAHAAAAAAAAA—A—A— ‘ |— |
                «§ig 3._L .LA 112L AEMELACE           SeA——eHeRmA—A———=——G———H
       |        —1.0       jexty _E0       _L         12B4 EOEdE TAE OE OB B OEREL LAE T20 _TEA
                      o          60             120         180           240      300             360
                                                           6 1]




                                      Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




Certificate No: ET3—1387_MarO5                              Page 6 of 9


    ET3DV6 SN:1387                                                                                         March 18, 2005


                                                  Dynamic Range f(SARpesq)
                                                        (Waveguide R22, f = 1800 MHz)



                                  1.E+7


                                  1.E+6


                                  1.E+5
              Input Signal [mV]




                                  1.E+4


                                  1.E+3


                                  1.E+2


                                  1.E+1


                                  1.E+0            §
                                     0.0001     0.001     0.01         0.1           1       10      100
                                                                 SAR [mW/cm‘]

                                              —®— not compensated               —®— compensated
                 Error [dB]




                                   0.001         0.01            0.1             1           10            100

                                                                 SAR [mW/cm‘]


                                                 Uncertainty of Linearity Assessment: £ 0.6% (k=2)




Certificate No: ET3—1387_Mar05                                    Page 7 of 9


    ET3DV6 SN:1387                                                                                           March 18, 2005



                                    Conversion Factor Assessment

                   f= 900 MHz, WGLS RY (head)                                    f= 1810 MHz, WGLS R22 (head)
             3.5           —                                                    30.0                      4                  <


             3.0                                                                25.0                    J@{cz L4
                                                                                                              [  ——A_L<L—I \|
                                                                                                                 |        |
          §4*° -                                                         Z 200                          ‘ f——fL            ‘ | ‘
          "g 2.0 —                                                       "E
          3                                                              3 150 1—
     |    E154                                                           E                                                          |
                                                                         C
     | &3 10|                                                            & 100                                                      |

             0.5 —                                                               5.0

             0.0 +             *             *                                   0.0                             -               |
                   o           20           40              60                         o           20           40           60 |
                                    z[mm]                                                               z[mm]

              Ge— Analytical        —O—Measurements                               —@— Analytical        —0—Measurements



   f [MHz] Validity [MHz]®            TSL    Permittivity        Conductivity      Alpha      Depth       ___ConvF Uncertainty
    900       +50/+ 100              Head 41.5%+5%               0.97+5%               0.65     1.81       6.47 £11.0% (k=2)
    1810      +50/+100               Head 40.0%5%                140+5%                o.62     2.39       5.18 £11.0% (k=2)
    2450      £50/+ 100              Head 39.2+5%                1.80+5%               0.76    2.09        4.56 £11.8% (k=2)



    900       £50/+ 100              Body 55.0%5%                 1.05+5%              0.60    2.01        6.10 £11.0% (k=2)
    1810      +50/+100               Body 53.3%+5%                1.52+5%              0.60    2.67        4.75 £11.0% (k=2)
   2450       £50/+100               Body 52.7+5%                1.95+5%               0.82     1.82       4.30 £11.8% (k=2)




   © The validity of £ 100 MHz only applies for DASY v4.4 and higher (see Page 2). The uncertainty is the RSS
   of the ConvF uncertainty at calibration frequency and the uncertainty for the indicated frequency band.




Certificate No: ET3—1387_Mar05                           Page 8 of 9


   ET3DV6 SN:1387                                                                                         March 18, 2005



                                 Deviation from Isotropy in HSL
                                               Error (¢, 9), f = 900 MHz




                                                                                             Error [dB]




                           ©—1.00——0.80 ©—0.80——0.60 ©—0.60—0.40 l-O;O;O.ZO ©—0.20—0.00 |
                           ©0.00—0.20   ©0.20—0.40   ©0.40—0.60    ©0.60—0.80   ©0.80—1.00




                             Uncertainty of Spherical Isotropy Assessment: 2.6% (k=2)




Certificate No: ET3—1387_Mar05                       Page 9 of 9


Schmid & Partner Engineering AG                                 s             e   a

Zeughausstrasse 43, 8004 Zurich, Switzerland
Phone +41 1 245 9700, Fax +41 1 245 9779
info@speag.com, http://www.speag.com




                         Additional Conversion Factors
                                               for Dosimetric E—Field Probe



                  Type:                                             ET3DV6



                  Serial Number:                                       1387



                  Place of Assessment:                               Zurich



                  Date of Assessment:                            March 21, 2005



                  Probe Calibration Date:                        March 18, 2005


       Schmid & Partner Engineering AG hereby certifies that conversion factor(s) of this probe
       have been evaluated on the date indicated above. The assessment was performed using
       the FDTD numerical code SEMCAD of Schmid & Partner Engineering AG. Since the
       evaluation is coupled with measured conversion factors, it has to be recalculated yearly,
       i.e., following the re—calibration schedule of the probe. The uncertainty of the numerical
       assessment is based on the extrapolation from measured value at 900 MHz or at 1800
       MHz.




                  Assessed by:
                                                                Zeleg~
                                                                /   f




ET3DV6—SN:1387                                    Page 1 of 2                         March 21, 2005


Schmid & Partner Engineering AG                              s               e         a

Zeughausstrasse 43, 8004 Zurich, Switzerland
Phone +41 1 245 9700, Fax +41 1 245 9779
info@speag.com, http://www.speag.com




Dosimetric E—Field Probe ET3DV6 SN:1387
Conversion factor (+ standard deviation)


f = 150 MHz               ConvF           8.8 + 10%                    s,= 52.3 4# 5%
                                                                      0 =0.76 +# 5% mho/m
                                                             (head tissue)

f= 300 MHz                ConvF           7.9 + 9%                    €]= 45.3 +# 5%
                                                                      0 = 0.87 + 5% mho/m
                                                             (head tissue)

f = 450 MHz               ConvF           7.5 +8%                     €,= 43.5 4# 5%
                                                                      0 =0.87 +5% mho/m
                                                             (head tissue)

£ = 150 MHz               ConvF           8.4 + 10%                   €r= 61.9 #5%
                                                                      0 =0.80 +# 5% mho/m
                                                             (body tissue)

f = 450 MHz               ConvF           7.5 +8%                     €;= 56.7 + 5%
                                                                      0 =0.94 +5% mho/m
                                                             (body tissue)



Important Note:

For numerically assessed probe conversion factors, parametérs Alpha and Delta in the
DASY software must have the following entries: Alpha =0 and Delta= 1.

Please see also Section 4.7 of the DASY4 Manual.




ET3DV6—SN:1387                                 Page 2 of 2                             March 21, 2005