Test report 4

FCC ID: KBCIX300AC775WLBT

Test Report

Download: PDF
FCCID_505307

    CLASS B VERIFICATION MEASUREMENTS

Under Title 47 CFR, Parts 15.107(a), 15.207(a) Conducted Emissions

      and Parts 15.109(a), & & 15.209(a) Radiated Emissions




                               For


                   ITRONIX, Corporation


                      IX300 Tablet PC




                       December 17, 2004


                           Prepared By

                     Spectrum Technology, Inc.
                        209 Dayton Street
                       Edmonds, WA 98020
                           425 771-4482


                                     VERIFICATION

                               TABLE OF CONTENTS



Cover Page                                                        1

Table of Contents                                                 2

Letter of Submittal and Compliance                                3


TEST RESULTS AND DATA


AC Conducted Emissions Part 15.107(a), 15.207(a)                  4-7

Field Strength of Radiated Emissions Part 15.109 (a), 15.209(a)   8 - 10

Open Field Site and Antenna/Equipment Orientation                 11




                                                                           2


                       __ _”»-;;/”m
                                mavoan   ’F"




mnaeste
          wz   seanC    e       _7             k

          we
                            g
                            *
                            *


s PE C TR U M                                      209 Dayton Street, Suite 205
£ZEPMILC SEA ‘EA                                   Edmonds, WA 98020—3581              425 771—4482           425 771—9283 Fax
..-/




                            December 17, 2004

                            Federal Communications Commission
                            Authorization and Standards Division
                            7435 Oakland Mills Rd.
                            Columbia, M.D. 21046

                            Re: Model: 1X300 with AirCard 775, (WAN), WM168b—Molex, (WLAN), &
                                       MUBTC2—TH, (Bluetooth)


                            Gentlemen:



                            Spectrum Technology Incorporated has tested this Digital Device containing two
                            Intentional Radiators in accordance with the requirements contained in Part 15 of the
                            CFR 47. To the best of my knowledge these tests were performed using measurement
                            procedures consistent with ANSI C63.4 standard. The results demonstrate that the
                            equipment complies with the published standard. We are unable to warrant against
                            unpublished changes in requirements. The applicable rules are listed in the following
                            test report.

                            The open area test site used for the radiated emissions measurements is located at
                            Fluke Park II in Everett, Washington. The site information required by Part 2.98,
                            measured in accordance with ANSI C63.4—2001, was most recently renew with the FCC
                            and accepted by the FCC Sampling and Measurements Branch in August 2004.

                            This site is also on file with Industry Canada for the performance of radiated emissions
                            measurements. Test site information required by RSS—212, Issue 1 (provisional) was
                            most recently renewed with IC in January 2002. The site file number is IC 2089.


                            Sincerely,


                            L Altines
                            Rod Munro
                            President


TEST:               CONDUCTED SPURIOUS EMISSIONS

Manufacturer:       ITRONIX, Corporation.

Name:               IX300 Tablet PC

Model:              IX300 with AirCard 775, (WAN), WM168b-Molex, (WLAN), &
                    MUBTC2-TH, (Bluetooth)


Setup:

The equipment under test (EUT) was set up in accordance with the provisions of ANSI C63.4-
2001, Section 7, on a 1 X 1.5-meter non-conductive test table at our Edmonds, Washington
facility. The tabletop is 80 cm above a 2.5 x 2-meter horizontal ground plane and 40 cm
forward from a 2.25 X 2.4-meter vertical ground plane. The two ground planes are
continuously grounded along the common seam. The two 50 ohm/ 50 uHy Line Impedance
Stabilization Networks (LISN) are grounded to the horizontal ground plane. The EUT was
placed in a typical operational arrangement following the 10-cm spacing as detailed in
Section 6.2 and 11.2, and the power cord of the EUT plugged into the first LISN. The signal
output of this LISN was fed to the Agilent E7405 EMC analyzer using a 9 kHz bandwidth,
which served as the measuring instrument. The peripheral equipment, if any were powered
from a separate LISN.


Discussion:

Measurements of the AC power line conducted spurious emissions were made with the
ITRONIX IX300 inserted into the Desk Stand and set up in a representative system
configuration. The Desk Stand is also the charging stand for the IX300, which can operate
during the charging process. The frequency range from 150 kHz to 30 MHz was measured in
detail. No modifications were made prior to the final compliance test.

Preliminary measurements were made as described in Section 7.2.3. The EUT was set up
as an operational system. A Microsoft keyboard and a Microsoft optical mouse were
connected to the USB ports on the Desk Mount. Measurements were made for the AC
power input to the AC adapter Model: LSE9802A2060, which was connected to the Desk
Mount and in turn powering the IX300. Excess I/O cable lengths were draped .5 m straight
down behind the equipment then back up to the device used to terminate the line. The
system cables were carefully tuned during the preliminary measurements on all frequencies
of significance endeavoring to maximize the emissions observed. The test setup photos in
Exhibit 7 detail the cable and equipment configuration for this test.




                                                                                         4


The ITRONIX Desk Stand with the IX300 inserted, was turned on and fully operational
while the batteries were charging. This unit was set up to transmit with all three
transmitters active simultaneously during the measurements. During the preliminary
measurements this IX300 was set to operate with simultaneously transmit on the first
the low, then mid and finally the high channels respectively in multiple sets of
measurements covering operational range of both transmitters. Note that no
measurable change in the conducted emissions activity was observed when the
transmitters were turned on or off or varied over the channel combinations listed below.

   All of the following channel combinations were investigated during the preliminary measurements:

             AC555                                        WLAN & Bluetooth
  Channel      Frequency MHz                    Channel          Frequency MHz
    128             824.2              and         1                  2402
    190             836.6              and        40                  2441
    251             848.8              and        79                  2480
    512            1850.2              And         1                  2412
    661            1880.0              And        40                  2437
    810            1909.8              And        79                  2462



Final measurements were made as described in Section 7.2.3 while the EUT was fully
functional as it would be in worst case (all three transmitters on) normal operation. The
equipment had only one basic mode of operation, that being charging active. The final
measurements were made with the AC775 transmitter set to 1880 MHz and the WLAN
and Bluetooth Intentional Radiators set at 2412 MHz.

The following page shows the measured results of the EUT emission profile. The spectrum
was observed from .15 to 30 MHz. The Class B average limits are: 56 to 46 dBuV from (0.15
to .5 MHz), 46 dBuV from (.5 to 5 MHz) and 50 dBuV from (5 to 30 MHz).

The conducted emissions were measured with Quasi-peak and Average detectors during the
testing. The emissions results are reported for line 1, the "hot" and line 2, the "neutral"
conductors, each with respect to ground at the power terminal.

Conclusion


The ITRONIX, Corporation IX300 when charging in the Desk Stand, met the conducted
emissions requirements for Class B digital devices under Title 47 CFR, Part 15.107(a),
and for Intentional Radiators under Part 15.207(a).




                                                                                                      5


TEST:                     CONDUCTED SPURIOUS EMISSIONS

Manufacturer:             ITRONIX, Corporation.

Name:                     IX300 Tablet PC

Model:                    IX300 with AirCard 775, (WAN), WM168b-Molex, (WLAN), &
                           MUBTC2-TH, (Bluetooth)

Part 15.107(a) and 15.207(a) the Class B average limits are:     56 to 46 dBuV from (0.15 to .5 MHz),
                                                                 46 dBuV from (.5 to 5 MHz) and
                                                                 50 dBuV from (5 to 30 MHz).
Note: This Plot is Line 1 Peak detector for reference, QP and Average measured maximum values are
provided below. Complies with Part 15.107(a) and Part 15.207(a) limits.



ITRONIX IX300 KBCIX300AC775WLBT                                                         Mkr1 2.98 MHz
Ref 75 dBµV              #Atten 10 dB                                                     44.88 dBµV
Peak
Log                                                                                                     *
10          1
dB/




Start 150 kHz                                                                            Stop 30 MHz
Res BW 9 kHz                                   VBW 30 kHz                      Sweep 840 ms (401 pts)
   Signal                   Peak Ampl Qp Ampl Avg Ampl Peak ∆ LL1 Peak ∆ LL2
      (7)         Freq        dBµV     dBµV    dBµV          dB         dB
       1      2.981 MHz         50.46    49.75   45.88
       2      3.098 MHz         50.33    49.21   44.93
 ©     3       3.28 MHz         50.99    50.04   45.11
       4      3.459 MHz         51.21    50.38   45.26
       5      3.513 MHz         50.71    49.97   45.23
       6      3.516 MHz         50.56    49.90   45.35
       7       3.69 MHz         49.16    47.36   42.05




                            Note: ferrite located on AC adapter low voltage cord




                                                                                                            6


TEST:                     CONDUCTED SPURIOUS EMISSIONS

Manufacturer:             ITRONIX, Corporation.

Name:                     IX300 Tablet PC

Model:                    IX300 with AirCard 775, (WAN), WM168b-Molex, (WLAN), &
                           MUBTC2-TH, (Bluetooth)

Part 15.107(a) and 15.207(a) the Class B average limits are:     56 to 46 dBuV from (0.15 to .5 MHz),
                                                                 46 dBuV from (.5 to 5 MHz) and
                                                                 50 dBuV from (5 to 30 MHz).
Note: This Plot is Line 2 Peak detector for reference, QP and Average measured maximum values are
provided below. Complies with Part 15.107(a) and Part 15.207(a) limits.



ITRONIX IX300 KBCIX300AC775WLBT                                                       Mkr1 352.32 kHz
Ref 75 dBµV              #Atten 10 dB                                                     50.67 dBµV
Peak
Log
                  1
10
dB/




Start 150 kHz                                                                           Stop 30 MHz
Res BW 9 kHz                                   VBW 30 kHz                  Sweep 881.3 ms (1515 pts)
    Signal                  Peak Ampl Qp Ampl Avg Ampl Peak ∆ LL1 Peak ∆ LL2
       (7)        Freq        dBµV     dBµV    dBµV          dB         dB
        1     236.7 kHz         51.39    48.73   45.29
        2     356.7 kHz         51.49    50.02   46.22
        3     952.9 kHz         48.05    47.28   43.29
        4     1.192 MHz         47.68    47.06   42.86
        5     4.285 MHz         47.93    46.32   42.35
        6     4.647 MHz         48.35    47.46   44.57
        7     4.942 MHz         46.91    45.62   42.75




                            Note: ferrite located on AC adapter low voltage cord




                                                                                                        7


TEST:               FIELD STRENGTH OF RADIATED EMISSIONS
Manufacturer:       ITRONIX, Corporation.

Name:               IX300 Tablet PC

Model:              IX300 with AirCard 775, (WAN), WM168b-Molex, (WLAN), &
                    MUBTC2-TH, (Bluetooth)

Setup:

The equipment under test (EUT) was configured and operated in accordance with the
applicable provisions of ANSI C63.4-2001, Section 6 and 8. The EUT was placed on
the 80 cm height, 1 X 1.5 m non-metallic turntable that sits above the 15 X 30 meter
ground plane at Spectrum's Open Area Test Site. There was no power cord as the
device was battery operated. The antennas (dipoles, bi-conical or log-periodic) were
mounted on a tower spaced at a 3 meters distance, and arranged for adjustment in
height (1-4 meters) and V/H orientation to maximize the emissions levels when
combined with turntable rotation of the EUT. An Agilent E7405 EMC analyzer, using
120 kHz bandwidth and a HP 8447F OPT H64 Amplifier were used for the measuring
instrumentation.


Discussion:

Measurements of the radiated spurious emissions were made with the ITRONIX IX300
inserted into the Desk Stand and set up in a representative system configuration. The Desk
Stand is also the charging stand for the IX300, which can operate during the charging
process. The frequency range from 30 to 1000 MHz was measured in detail. No
modifications were made prior to the final compliance test.

Preliminary measurements were made as described in Section 8.3.1.1. The EUT was set up
as an operational system. A Microsoft keyboard and a Microsoft mouse were connected to
the two USB ports on the Desk Stand. Excess I/O cable lengths were draped .5 m straight
down behind the equipment then back up to the device used to terminate the line. The
system cables were carefully tuned during the preliminary measurements on all frequencies
of significance endeavoring to maximize the emissions observed.

During the preliminary measurements the IX300 was set up at the OATS facility with the
receive antenna in close proximity, about 1.0 meter distance. The IX300 was operated on
the frequencies listed on the following page to identify measurable emission frequencies.
The test setup photos in Exhibit 7 detail the exact cable and equipment configuration for
this test. During the preliminary measurements this IX300 was set to operate with
simultaneously transmit on the first the low, then mid and finally the high channels
respectively in multiple sets of measurements covering operational range of both

                                                                                        8


transmitters. Note that no measurable change in the conducted emissions activity was
observed when the transmitters were turned on or off or varied over the channel
combinations listed below.

All of the following channel combinations were investigated during the preliminary measurements:

                AC555                                      WLAN & Bluetooth
     Channel      Frequency MHz                  Channel          Frequency MHz
       128             824.2            and         1                  2402
       190             836.6            and        40                  2441
       251             848.8            and        79                  2480
       512            1850.2            and         1                  2412
       661            1880.0            and        40                  2437
       810            1909.8            and        79                  2462




Preliminary measurements were made while the system was investigated operating in
the following modes:

1)        IX300 operating digital device active only, no transmitters turned on.

2)        IX300 operating with the Bluetooth transmitter on low, mid and hi channel.

3)        IX300 operating with the AirCard 775 transmitting on the high mid and low
          channels in the Cellular and PCS bands.

For the final measurements, the IX300 inserted in the ITRONIX Desk Stand, turned on
and fully operational while the battery was charging. This unit was set up to transmit
with all three transmitters active simultaneously during the measurements.

The final OATS test configuration is shown in photographs included in this report. Final
digital device measurements were made from 30 - 1000 MHz as specified in Section
8.3.1.2 and were made at three meters.


Conclusion:


The ITRONIX, Inc. IX300 when operated as discussed above meets the radiated
emissions requirements for a receivers and Class B digital devices under Title 47 CFR,
Parts 15.109(a) and 15.209(a).




                                                                                                   9


            EXHIBIT 6 TEST: FIELD STRENGTH OF SPURIOUS RADIATED EMISSIONS

   FCC ID: KBCIX300AC775WLBT

   Applicant: ITRONIX Corp.

   Model: IX300 with AirCard 775, (WAN), WM168b- Molex, (WLAN), &
           MUBTC2-TH, (Bluetooth)

       Minimum Standard Specified: Part 15.109(a), 15.209(a)
       Frequency Range Observed: 30 to 1 GHz
       Date: 12/09/04
      Test Setup: See block diagram following.

    NOTE: Simultaneous co-location transmit on the identical low, mid & hi freq. with the WM168b-Molex, (WLAN)
    and the MUBTC2-TH, (Bluetooth), intentional radiators. AC775 was also transmitting on its low, mid and high
    channels respectively (1850.2, 1880, 1909.8 MHz). The AC775 transmitter maximum power output was fed to a
    resistive coaxial termination.

                                   RADIATED SPURIOUS EMISSIONS
Frequency     Max.     Ant.       Peak or    Antenna   Cable      Amp       Corrected   Limit      Margin in
  GHz         SA       Vert. or   Average    Factor    loss       Gain      Reading                dB
              Rdg.     Horz.      Detector   dB        dB                   dBuV/m      dBu/V      below
              dBu/V                                                                                LIMIT

  128.90       20.50      H        Peak        8.6       2.38      -inc.-     31.48       43.5       12.02
  128.90       15.47      V        Peak        8.6       2.38      -inc.-     26.45       43.5       17.05
  130.00       15.31      H        Peak        8.6       2.38      -inc.-     26.29       43.5       17.21
  130.00       12.85      V        Peak        8.6       2.38      -inc.-     23.83       43.5       19.67
 132.54 *      27.17      H        Peak        8.7       2.40      -inc.-     38.27       43.5        5.23
 132.54 *      19.86      V        Peak       8.7        2.40      -inc.-     30.96       43.5       12.54
 133.23 *      25.82      H        Peak        8.7       2.40      -inc.-     36.92       43.5        6.58
 133.23 *      19.72      V        Peak       8.7        2.40      -inc.-     30.82       43.5       12.68
  171.26       16.18      H        Peak       10.1       2.68      -inc.-     28.96       43.5       14.54
  171.26       13.32      V        Peak       10.1       2.68      -inc.-     26.10       43.5       17.40
  298.99       10.21      H        Peak       13.9       3.30      -inc.-     27.41       46.0       18.59
  298.99       18.26      V        Peak       13.9       3.30      -inc.-     35.46       46.0       10.54
 397.50 *      22.32      H        Peak       16.1       3.79      -inc.-     42.21       46.0        3.79
 397.50 *      21.93      V        Peak       16.1       3.79      -inc.-     41.82       46.0        4.18
 397.75 *      20.53      H        Peak       16.1       3.79      -inc.-     40.42       46.0        5.58
 397.75 *      21.30      V        Peak       16.1       3.79      -inc.-     41.19       46.0        4.81
  480.00       20.70      H        Peak       17.7       4.00      -inc.-     42.40       46.0        3.60
  480.00       21.35      V        Peak       17.7       4.00      -inc.-     43.05       46.0        2.95

                          * Broadband emission upper and lower peak level recorded




                                                                                                      10


                     EXHIBIT VII - Test Set-Up Procedures


                                      BLOCK DIAGRAM #1

                            Radiated Spurious Emissions Test Set Up




            D = 100 ft. or 3 meters

             │                  │1/2 Wave Dipole *
             │                  │
             │        D         │
             ├──────────────────┼────┐
             │                  │    │
             │                  │    │
             │                  │    │
             │                       │
             │                       │
             │                       │
    ┌────────┴─────────┐             │
    │                   │            │
    │ Equipment         │            │
    │ Under Test        │            │
    │                   │            │
    └──────────────────┘             │
                                     │
                                     │
                                     │        ┌────────────────┐
                                     │        │                │
                                     │        │ Spectrum       │
                                     └────────┤ Analyzer       │
                                              │                │
                                              │                │
                                              └────────────────┘




      See Equipment List for Models

*    1/2 Wave Dipole 30-1000 MHz or Bi-Conilog
     Dual Ridged Guide Antenna or Broadband Log Periodic 1-18 GHz
     Standard Gain Horn 18 – 26.5 GHz




                                           End of Report
                                                                      11



Document Created: 2004-12-28 16:27:03
Document Modified: 2004-12-28 16:27:03

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC