Spectrum EMC Test Report Rev1

FCC ID: KBCIX260MPI350

Test Report

Download: PDF
FCCID_292435

                       EXHIBIT VI.

              Supplemental Test Report


New Certification of Previously Certified OEM Module

             FCC ID: KBCIX260MPI350

      IX260 with Integrated Compact Flash WLAN


         Certification Under Title 47 CFR, Part 15.247




                    Prepared On Behalf Of

                  ITRONIX, Corporation
                    South 801 Stevens St.
                     Spokane, WA 99204


                           Prepared

                              By
                   Spectrum Technology, Inc.
                  209 Dayton Street, Suite 205
                     Edmonds, WA 98020
                         425 771-4482




                 Revised December 23, 2002

                          Exhibit VI


Applicant: ITRONIX, Corporation                                                FCC ID: KBCIX260MPI350




                                  Supplemental Test Report

                                       TABLE OF CONTENTS



Cover Page                                                                                  1


Table Of Contents                                                                           2


Exhibit 6 –     Conducted RF Power Output Part 15.247 (b)                                   3
                & Equivalent Isotropic Radiated Power

Exhibit 6 –     Radiated Harmonics and Spurious Emissions                                   4
                & Radiated Field Strength For Three Channels




Note: Please refer to the original Certification exhibits for all of the original test report data for the following Cisco
Systems, Inc., Intentional Radiator referenced herein:

1.) FCC ID: LDK102042, IEEE 802.11(b), WLAN Compact Flash Card, Model: MPI-350 Series




                                                    Exhibit VI                                                          2


Applicant: ITRONIX, Corporation                                              FCC ID: KBCIX260MPI350




EXHIBIT 6A             TEST: CONDUCTED RF POWER OUTPUT

FCC ID:                                           KBCIX260MPI350

Applicant:                                        ITRONIX, Corporation

Model:                                            IX260 with MPI350 WLAN


Minimum Standard Specified:                       Part 15.247(b)(1) is 1 Watt for DSSS

Test Results:                                     The measured output power level shows compliance with the above limit
                                                  and the power granted for the OEM module.

Authorization   Procedure:                        Part 2.1046

Maximum Conducted Power Output:                   21.2 dBm


Method of Measurement:

1.      The output power levels above had been preset during production for this model.
2.      The peak output power was measured 12/10/02 by Celltech with a Gigatronics 8652A Universal Power Meter (S/N:
        1835272). The measured channels cover the low, middle and top of the operational frequency range previously
        approved for this Intentional Radiator of 2412 - 2462 MHz.
4.      Both antenna ports were measured, the results below were the maximum level measured.



                     Tabular Results of Conducted RF Output Power and EIRP


    WLAN                                                   Rangestar
   Serial No:                                               Antenna
VMS06180144                                                P/N 100929
  Frequency            Power           Cable loss           Ant. Gain           EIRP
     GHz                dBm                                    dBi
    2.412               21.2              -inc-                4.5               25.6
    2.437               21.1              -inc-                4.5               25.6
    2.462               21.1              -inc-                4.5               25.7        * max.

The maximum WLAN EIRP is 25.7 dBm with the Rangestar Antenna, P/N 100929, peak antenna gain of 4.5 dBi.




                                                    Exhibit VI                                                       3


Applicant: ITRONIX, Corporation                                              FCC ID: KBCIX260MPI350

EXHIBIT 6G               TEST: RADIATED HARMONICS AND SPURIOUS EMISSIONS

FCC ID:                                           KBCIX260MPI350

Applicant:                                        ITRONIX Corporation

Model:                                            IX260 with MPI350 WLAN

Minimum Standard Specified:                       Part 15.247(c), 15.205 & 15.209(a)

Test Results:                                     Equipment complies with standard

Authorization Procedure:                          Part 2.1053

Test Equipment Set Up:                            See Block Diagram in Exhibit 7

Frequency Range Observed:                         0 to 25 GHz

Operating Frequencies WLAN:                       2412, 2437, & 2462 MHz (2412 - 2462 MHz band)



                Radiated Field Strength For Three Channels and Related Harmonics and Spurious

   WLAN                Ant.    Spectrum              +           -         +              =             or
Frequency in           Vert/   Analyzer Reading     Ant         Amp       Cable         dBuV/m         uV/m
GHz                    Horz    dBuV                 Factor      Gain      Loss         @ 3 meters     @ 3 meters

Ch. 1 Low 2.412          V        83.17             28.37        0         1.33         112.87         440047.94
Ch. 6 Mid 2.437          V        83.50             28.37        0         1.33         113.20         457088.18
Ch.11 High 2.462         V        83.83             28.37        0         1.33         113.53         474788.29

   WLAN            Frequency in GHz         Harmonics observed                Limit     74 dBuV/m Peak &
                                                                                        54 dBuV/m Average
Ch. 1 -Low Fo      2.412
2Fo - 10Fo         4.824 – 24.120         None, At or < noise floor @3m    All emissions < 54 dBuV/m or 500 uV/m
Ch. 6 -Mid Fo      2.437
2Fo – 10Fo         4.874 – 24.370         None, At or < noise floor @3m    All emissions < 54 dBuV/m or 500 uV/m
Ch. 11 -High Fo    2.462
2Fo - 10Fo         4.924 – 24.620         None, At or < noise floor @3m    All emissions < 54 dBuV/m or 500 uV/m

All harmonic and spurious emissions were below the limit. 2Fo and 3Fo were measurable during preliminary
measurements at 1.0 meter with 100 kHz RBW only, but not at 3 meters with 1 MHz RBW. A HP preamplifier with over 20
dB of gain was used during the measurements of the harmonics. A high pass filter was used to reduce the fundamental
signal and avoid the possibility of overloading the front end of the analyzer when using the preamp.
Test Notes:     1.) All harmonics in the restricted bands listed in Part 15.205 are below the Part 15.209(a) limit.
                2.) No peak emissions above 1 GHz are more than 20 dB above the average limit.
                3.) Peak measurements made with 1 MHz RBW & VBW, Average made with 1MHz RBW & 10 Hz VBW.
                4.) One set of measurements was made for each antenna. The highest levels reported above were
                     emanating from the right antenna port.
                                                    Exhibit VI                                                     4



Document Created: 2019-11-10 18:18:28
Document Modified: 2019-11-10 18:18:28