WLAN Back Side SAR Test Plot

FCC ID: KBCIX100XA750WLBT

RF Exposure Info

Download: PDF
FCCID_464567

Date: 08/25/04

2450MHz Body SAR (Lap-held) - Back Side of DUT Touching Planar Phantom - WLAN Single Transmit

DUT: Itronix Model: IX100XA750WLBT; Type: Rugged Handheld PC with 802.11b/Bluetooth/GPRS; Serial: 510495001-U5103-0025

Ambient Temp: 24.0°C; Fluid Temp: 22.5°C; Barometric Pressure: 101.0 kPa; Humidity: 30%

7.4V, 3.0Ah Li-ion Battery Pack
Communication System: DSSS
Frequency: 2437 MHz; Duty Cycle: 1:1
RF Output Power: 14.0 dBm (Peak Conducted)
                                                       3
Medium: M2450 (σ = 1.97 mho/m; εr = 50.2; ρ = 1000 kg/m )

- Probe: ET3DV6 - SN1590; ConvF(4.22, 4.22, 4.22); Calibrated: 24/05/2004
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn370; Calibrated: 14/05/2004
- Phantom: Barski Industries; Type: Fiberglas Planar; Serial: 03-01
- Measurement SW: DASY4, V4.3 Build 16; Postprocessing SW: SEMCAD, V1.8 Build 123


Back of Device Touching Planar Phantom - Without Carry Case - Mid Channel
Area Scan (10x22x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.00435 mW/g



Document Created: 2004-08-31 20:06:09
Document Modified: 2004-08-31 20:06:09

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC