SAR Report part 4

FCC ID: KBCIX-MC8775

RF Exposure Info

Download: PDF
FCCID_973940

Calibration Laboratory of                                           ¢\“"\":';",""/.;                               Schweizerischer Kalibrierdienst
Schmid & Partner                                                   N               i                               Service suisse d‘étalonnage
   Engineering AG                                                 P               T                                Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                        *47;\\‘\\“\-                                   Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                              Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


ctem                                                                                            Exe:eco0capros



 Calibration date:


 Condition of the calibrated item



 This calibration certificate documents the traceability to national standards, which realize the physicalunits of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of thecertificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                       ID #                      Cal Date (Certificate No.)                           Scheduled Calibration
 Power meter E44198                     GB41293874                 1—Apr—08 (No. 217—00788)                             Apr—09
 Power sensor E4412A                    MY41495277                 1—Apr—08 (No. 217—00788)                             Apr—09
 Power sensor E4412A                    MY41498087                 1—Apr—08 (No. 217—00788)                             Apr—09
 Reference 3 dB Attenuator              SN: $5054 (3c)             B8—Aug—07 (No. 217—00719)                            Aug—08
 Reference 20 dB Attenuator             SN: 5086 (20b)             31—Mar—08 (No. 217—00787)                            Apr—09
 Reference 30 dB Attenuator             SN: $5129 (30b)            8—Aug—07 (No. 217—00720)                             Aug—08
 Reference Probe ES3DV2                 SN: 3013                   2—Jan—08 (No. ES3—3013_Jan08)                        Jan—09
 DAE4                                   SN: 660                    3—Sep—07 (No. DAE4—660_SepO7)                        Sep—08

 Secondary Standards                     ID #                      Check Date (in house)                                Scheduled Check
 RF generator HP 8648C                  US3642U01700               4—Aug—99 (in house check Oct—07)                     In house check: Oct—09
 Network Analyzer HP 8753E              US37390585                 18—Oct—01 (in house check Oct—07)                    In house check: Oct—08 «

                                        Name            €              .          Function                          _   Signature
 Calibrated by:


 Approved by:



                                                                                                                        Issued: April 22, 2008
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.


Certificate No: EX3—3600_Apr08                                             Page 1 of 9


Calibration Laboratory of                                                        §   Schweizerischer Kalibrierdienst
Schmid & Partner                                            ;}E’/fi@?’            c   Service suisse d‘étalonnage
  Engineering AG                                            Z.;_—\\6                 Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                 *4,fi\\‘\\\‘         S   Swiss Calibration Service
                                                                Anduty®



Accredited by the Swiss Accreditation Service (SAS)                               Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates



Glossary:
TSL                          tissue simulating liquid
NORMx,y,z                    sensitivity in free space
Convr                        sensitivity in TSL / NORMx,y,z
DCP                          diode compression point
Polarization q               @ rotation around probe axis
Polarization 8               8 rotation around an axis that is in the plane normal to probe axis (at
                             measurement center), i.e., 8 = 0 is normal to probe axis

Calibration is Performed According to the Following Standards:
    a) IEEE Std 1528—2003, "IEEE Recommended Practice for Determining the Peak Spatial—
         Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
         Communications Devices: Measurement Techniques", December 2003
    b) IEC 62209—1, "Procedure to measure the Specific Absorption Rate (SAR) for hand—held
       devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz)",
       February 2005

Methods Applied and Interpretation of Parameters:
   e NORMx,y,z: Assessed for E—field polarization 8 = 0 (f < 900 MHz in TEM—cell; f > 1800 MHz:
     R22 waveguide). NORMx.y,z are only intermediate values, i.e., the uncertainties of
     NORMx,y,z does not effect the E®—field uncertainty inside TSL (see below ConvF).
    e    NORM(PAx,y,z = NORMx,y,z * frequency_response (see Frequency Response Chart). This
         linearization is implemented in DASY4 software versions later than 4.2. The uncertainty of
         the frequency response is included in the stated uncertainty of ConvF.
    e    DCPx,y,z: DCP are numerical linearization parameters assessed based on the data of
         power sweep (no uncertainty required). DCP does not depend on frequency nor media.
    e    ConvrF and Boundary Effect Parameters: Assessed in flat phantom using E—field (or
         Temperature Transfer Standard for f < 800 MHz) and inside waveguide using analytical field
         distributions based on power measurements for f > 800 MHz. The same setups are used for
         assessment of the parameters applied for boundary compensation (alpha, depth) of which
         typical uncertainty values are given. These parameters are used in DASY4 software to
         improve probe accuracy close to the boundary. The sensitivity in TSL corresponds to
         NORMx,y,z * ConvF whereby the uncertainty corresponds to that given for ConvF. A
         frequency dependent ConvF is used in DASY version 4.4 and higher which allows extending
         the validity from + 50 MHz to + 100 MHz.
    e    Spherical isotropy (3D deviation from isotropy): in a field of low gradients realized using a
         flat phantom exposed by a patch antenna.
    e    Sensor Offset: The sensor offset corresponds to the offset of virtual measurement center
         from the probe tip (on probe axis). No tolerance required.


Certificate No: EX3—3600_Apr08                                  Page 2 of 9


    EX3DV4 SN:3600                                                                April 19, 2008




                       Probe EX3DV4
                                            SN:3600
                                 Manufactured:                   January 10, 2007
                                 Last calibrated:                January 24, 2007
                                 Recalibrated:                   April 19, 2008

                                     Calibrated for DASY Systems
                                      (Note: non—compatible with DASY2 system!)




Certificate No: EX3—3600_Apr08                   Page 3 of 9


    EX3DV4 SN:3600                                                                                               April 19, 2008


    DASY — Parameters of Probe: EX3DV4 SN:3600


    Sensitivity in Free SpaceA                                                                 Diode CompressionB

              NormX                    0.480 £10.1%                 uV/(V/im)                 DCP X            86 mV
              NormY                    0.500 £10.1%                 uV/(V/im)                 DCP Y            88 mV
              NormzZ                   0.380 £10.1%                 uV/(V/im)                 DCP Z            92 mV


    Sensitivity in Tissue Simulating Liquid (Conversion Factors)
    Please see Page 8.


    Boundary Effect

    TSL                      1810 MHz           Typical SAR gradient: 10 % per mm


              Sensor Center to Phantom Surface Distance                                       2.0 mm    3.0 mm
              SARp, [%]             Without Correction Algorithm                                  7.7    3.3
              SARpe [%]             With Correction Algorithm                                     0.2    0.5




    Sensor Offset

              Probe Tip to Sensor Center                                                 1.0 mm




    The reported uncertainty of measurement is stated as the standard uncertainty of
    measurement multiplied by the coverage factor k=2, which for a normal distribution
    corresponds to a coverage probability of approximately 95%.



   * The uncertainties of NormX,Y,Z do not affect the E*—field uncertainty inside TSL (see Page 8).
   ® Numerical linearization parameter: uncertainty not required.




Certificate No: EX3—3600_Apr08                                Page 4 of 9


    EX3DV4 SN:3600                                                                                                April 19, 2008


                                                      Frequency Response of E—Field
                                                           (TEM—Cell:ifi110 EXX, Waveguide: R22)
               Frequency response (normalized)




                                                 0      500       1000        1500     2000      2500       3000




                                                     Uncertainty of Frequency Response of E—field: £ 6.3% (k=2)




Certificate No: EX3—3600_Apr08                                           Page 5 of 9


    EX3DV4 SN:3600                                                                          April 19, 2008



                                   Receiving Pattern (¢), 9 = 0°
                                                             |

                f= 600 MHz, TEM ifi110EXX                    ‘         f= 1800 MHz, WG R22




           —@—       —@—Y        —@—Z    —O—Tot




          1.0               e                     C s
         0.8           +4         1—                     ‘
    |_   o6                                                                             —0—30 MHz
    | _z 04                                                                           | —m— 100 MHz
    | s 02                                                                                 | —>—600 MHz
      5 g'g                                                                                | —m— 1800 MHz _
     4 lng |                                                              CZZZAZZ |—a—2500mHe] |
         —0.6
         —0.8
         —1.0                                     JPPJJP
                0           60          120       180            240      300        360
                                                  4 1]



                                 Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




Certificate No: EX3—3600_Apr08                    Page 6 of 9


    EX3DV4 SN:3600                                                                                          April 19, 2008


                                                  Dynamic Range f(SARpeaq)
                                                        (Waveguide R22, f = 1800 MHz)



                                  1.E+7



                                  1.E+6



                                  1.E+5
              Input Signal [uV)




                                  1.E+4



                                  1.E+3



                                  1.E+2



                                  1.E+1



                                  1.E+0
                                     0.0001     0.001     0.01         0.1           1       10      100
                                                                 SAR [mW/icm‘]

                                              —®— not compensated               —®— compensated
              Error [dB]




                                   0.001         0.01            0.1             1           10            100

                                                                 SAR [mW/cm‘]


                                                 Uncertainty of Linearity Assessment: £ 0.6% (k=2)




Certificate No: EX3—3600_Apr08                                    Page 7 of 9


    EX3DV4 SN:3600                                                                                             April 19, 2008


                                  Conversion Factor Assessment

                f= 1810 MHz, WGLS R22 (head)                                   f = 5800 MHz, WGLS R58 (head)
               sys                ccces                                       800j y

               25.0       4   4         f
                                         _
                                         42004
                                                                              7oo $
                                                   |                          600 +\
           E 20.0 /                                                       E 500

           t
           § 15.0
                                                                         T3 400
           E
           &
                                                                          &
                                                                          Fa
                                                                             soo
       —   § 10.0                                                         %         |
       |                                                                      200 ;
       |        5.0
       |                                                                      100 +

                0.0                                                             0 +           —P°                                   |
                      0                                                            0              10            20           30
                                     z[mm]                                                             z[mm]


               (Seons —ememsoien:                                             [—omarke _ —+—mewerek |

   f [MHz] Validity [MHz]®          TSL      Permittivity    Conductivity       Alpha      Depth       ConvF Uncertainty

    1810       £50/£ 100            Head     40.0£5%         1.40£5%               0.82    0.58          7.32 £11.0% (k=2)
    1950       £50/+ 100            Head     40.0£5%         140 +5%               0.85    0.57          6.99 +11.0% (k=2)

    2450       £50/% 100            Head     39.2+£5%        1.80+5%               0.79    0.58          6.75 £11.0% (k=2)

    5800       £50/% 100            Head     35.3 %£5%       5.27 + 5%            0.50     1.70          411     £13.1% (k=2)




    1810       £50/+ 100            Body     53.3%5%         1.52%5%               0.93    0.56          745     +11.0% (k=2)

    1950       £50/+ 100            Body     53.315%         1.52+5%               0.92    0.55          7.07        #11.0% (k=2)

   2450        £50/£ 100            Body     52.7%5%         1.95%5%               0.59    0.73          6.32        £11.0% (k=2)
    5200       £50/+ 100            Body     49.0£5%         5.30 £5%              0.50    1.70          3.84        £13.1% (k=2)

    5500       £50/+ 100            Body     48.6£5%         5.65 £5%              0.48    1.70          3.86    £13.1% (k=2)

   5800        £50/% 100            Body     48.2£5%         6.00 £5%              0.47    1.70          3.93    £13.1% (k=2)




   © The validity of £ 100 MHz only applies for DASY v4.4 and higher (see Page 2). The uncertainty is the RSS
   of the ConvF uncertainty at calibration frequency and the uncertainty for the indicated frequency band.




Certificate No: EX3—3600_Apr08                            Page 8 of 9


    EX3DV4 SN:3600                                                                                    April 19, 2008



                                 Deviation from Isotropy in HSL
                                        Error (¢, 9), f = 900 MHz




                                                                                                      Error [dB]

                                                                        n
                                  ©®—1.00——0.80 ©—0.80——0.60 ©M—0.60——0.40 ©—0.40——0.20 ©—0.20—0.00

                                  ©0.00—0.20   ©0.20—0.40   ©0.40—0.60    ©0.60—0.80   ©0.80—1.00




                             Uncertainty of Spherical Isotropy Assessment: £ 2.6% (k=2)




Certificate No: EX3—3600_Apr08                       Page 9 of 9



Document Created: 2008-07-08 15:06:24
Document Modified: 2008-07-08 15:06:24

© 2024 FCC.report