MPE Estimates 1

FCC ID: KBCIX-MC5725

RF Exposure Info

Download: PDF
FCCID_801433

 Applicant: General Dynamics Itronix, Corporation                                     FCC ID: KBCIX-MC5725
                                                                                      FCC ID: KBCIX270-WL3945
                                                                                      FCC ID: KBCIX270-BT2022




                                       Co-Located Exposure Condition


Compliance with 47 CFR 15.247(i)
                “Systems operating under the provisions of this section shall be operated in a manner that
                ensures that the public is not exposed to radio frequency energy levels in excess of the
                Commission's guidelines. See § 1.1307(b)(1) of this chapter.”

The EUT will only be used with a separation distance of 20 centimeters or greater between the antenna and the body of the
user or nearby persons and can therefore be considered a mobile transmitter per 47 CFR 2.1091 (b). Calculations are
provided for each radio transmitting through its own internal antenna and optional external antenna.

The total transmit power is less than 1.5 W (ERP), therefore the EUT is categorically excluded from routine environmental
evaluation per 47 CFR 2.1091(c).

The MPE estimates are as follows:

Table 1 in 47 CFR 1.1310 defines the maximum permissible exposure (MPE) for the general population. The exposure level
at a 20 cm distance from the EUT’s transmitting antenna is calculated using the general equation:

                S = (PG)/4πR2
                Where: S = power density (mW/cm2)
                P = power input to the antenna (mW)
                G = numeric power gain relative to an isotropic radiator
                R = distance to the center of the radiation of the antenna (20 cm = limit for MPE estimates)
                PG = EIRP

Solving for S, the maximum power densities 20 cm from the transmitting antennas are summarized in the tables on the
following pages:




                                                                                                                            1


 Applicant: General Dynamics Itronix, Corporation                                      FCC ID: KBCIX-MC5725
                                                                                       FCC ID: KBCIX270-WL3945
                                                                                       FCC ID: KBCIX270-BT2022

MPE Estimates for Self Located Device

FCC ID: KBCIX-MC5725
In the IX270 Host PC


CDMA

                                                                                                                            Ratio of
                                                                                                               General
                                                                Max Peak              Minimum                               Power
                                                                                                   Power      Population
                           Antenna Part        Transmit         Conducted   Antenna   Antenna                               Density
    Antenna Type                                                                                  Density     Exposure
                               No.            Frequency          Output      Gain      Cable                                 to the
                                                                                                  @ 20 cm     Limit from
                                                                  Power                 Loss                               Exposure
                                                                                                                1.1310
                                                                                                                              Limit
IX270                                            (MHz)            (mW)       (dBi)      (dB)     (mW/cm2)     (mW/cm2)
PRIMARY WAN ANTENNA         59-0521-001R    1851.25 - 1908.75     304.8      -1.50      0.89       0.035           1         0.035
PRIMARY WAN ANTENNA         59-0521-001R     824.7 – 848.31       325.8       1.50      1.50       0.065         0.55        0.118
External MaxRad          BMLPVDB800/1900    1851.25 - 1908.75     304.8        3        2.77       0.064           1         0.064
External MaxRad          BMLPVDB800/1900     824.7 – 848.31       325.8        3        3.33       0.060         0.55        0.109

Worst Case Ratio of Power Density to the
Exposure Limit = 0.118




Excerpts from TCB Training, April 3, 2002, “Mobile Transmitters”, Slide 6:

        “Devices operating in multiple frequency bands

             ‰    When RF exposure evaluation is required for TCB approval
                     o Separate antennas – estimated minimum separation distances may be considered for the frequency
                        bands that do not require evaluation or TCB approval, however, the estimated distance should take
                        into account the effect of co-located transmitters. (Note 24)

                         Note 24 According to multiple frequency exposure criteria, the ratio of field strength or power density
                         to the applicable exposure limit at the exposure location should be determined for each transmitter
                         and the sum of these ratios must not exceed 1.0 for the location to be compliant.”


The sum of the ratio(s) (power density to the exposure limit) does not exceed 1.0; therefore, the exposure condition is
compliant with FCC rules.




                                                                                                                               2


Applicant: General Dynamics Itronix, Corporation                                                FCC ID: KBCIX-MC5725
                                                                                                FCC ID: KBCIX270-WL3945
                                                                                                FCC ID: KBCIX270-BT2022



MPE Estimates for Self Located Device


FCC ID: KBCIX270-WL3945

WLAN, IEEE 802.11 (a) (b) & (g)

                                                                                                                                           Ratio of
                                                                                                                     General
                                                                                                                                           Power
                                                       Max Peak                        Minimum        Power         Population
Antenna        Antenna Part            Transmit                          Antenna                                                          Density to
                                                    Conducted Output                   Antenna       Density @      Exposure
 Type              No.                Frequency                           Gain                                                               the
                                                         Power                        Cable Loss       20 cm        Limit from
                                                                                                                                          Exposure
                                                                                                                      1.1310
                                                                                                                                            Limit
                                                                                                               2                   2
                                        (GHz)            (mW)              (dBi)         (dB)        (mW/cm )        (mW/cm )


PiFa
MAIN       TWR12WIPI02A                  5                100             -2.56          6.5          0.002                1            0.002
PiFa
MAIN       TWR12WIPI02A                 2.4               318             -2.72          3.5          0.015                1            0.015
External
MaxRad     MAXC24503                    2.4               318                  3         4.6          0.044                1            0.044
External
MaxRad     BMAXC24505                   2.4               318                  5         4.6          0.069                1            0.069

 Worst Case Ratio of Power Density to the Exposure Limit = 0.069




MPE Estimates for Self Co-located Device


FCC ID: KBCIX270-BT2022

Bluetooth Radio

                                                                                                                    General
                                                                                                                                       Ratio of Power
                                                     Max Peak                       Minimum         Power          Population
                                         Transmit                  Antenna                                                             Density to the
 Antenna Type      Antenna Part No.                  Conducted                      Antenna        Density @       Exposure
                                        Frequency                   Gain                                                                 Exposure
                                                    Output Power                   Cable Loss        20 cm         Limit from
                                                                                                                                            Limit
                                                                                                                     1.1310
                                                                                                         2                     2
                                           (MHz)       (mW)            (dBi)          (dB)      (mW/cm )           (mW/cm )
Well Green
Technology
Co. Ltd.
IX270-B/T or
R12Y-B/T           TWR12BLPI01A           2441         36.22           -2.56         0.69          0.0032              1                  0.0032

Worst Case Ratio of Power Density to the Exposure Limit = 0.0032




                                                                                                                                                   3


Applicant: General Dynamics Itronix, Corporation                                   FCC ID: KBCIX-MC5725
                                                                                   FCC ID: KBCIX270-WL3945
                                                                                   FCC ID: KBCIX270-BT2022




Worst Case Co-located Exposure Condition
FCC ID: KBCIX-MC5725
FCC ID: KBCIX270-WL3945
FCC ID: KBCIX270-BT2022
Per Note 24 shown below, the Sum of Worst Case Power Ratios cannot exceed 1.0

                                      Bluetooth
                    802.11abg                         Sum of Worst
CDMA Radio                              Radio
                 Radio Worst                           Case Ratios
 Worst Case                          Worst Case                         FCC Limit for
                  Case Ratio of                          (Power
Ratio of Power                      Ratio of Power                      Sum of Worst
                  Power Density                       Density to the
Density to the                      Density to the                       Case Ratios
                 to the Exposure                        Exposure
Exposure Limit                      Exposure Limit
                       Limit                              Limit)

    0.118             0.069            0.0032             0.1902             1.0              PASS


The results shown in the above table are equivalent to the Sum of the EIRP of the Two Co-located Transmitters
(EIRP TX1 + EIRP TX2) compared to the exposure limit. The benefit of this method, is that accounts for
transmitters operating at different frequencies against different exposure limits.




                                                                                                                4



Document Created: 2007-05-18 12:25:04
Document Modified: 2007-05-18 12:25:04

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC