SAR Report part 3

FCC ID: KBCIX-4965AGN

RF Exposure Info

Download: PDF
FCCID_931524

                             Date(s) of Evaluation              Test Report Serial No.              Test Report Revision No.
                            November 02, 06, 2007             102407KBC-T866-S15WB                  Rev. 1.0 (Initial Release)
                            Test Report Issue Date               Description of Test(s)              RF Exposure Category
                                 March 20, 2008                Specific Absorption Rate                General Population               Certificate No. 2470.01


APPENDIX G - PROBE CALIBRATION




Company:            General Dynamics Itronix Corporation                     FCC ID:          KBCIX-4965AGN                   IC:            1943A-4965AGN
 Model(s):         IX350        DUT Type:           Tablet PC with 802.11a/b/g/n WLAN & Co-located Bluetooth
2008 Celltech Labs Inc.    This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 71 of 72


Calibration Laboratory of
                                                                            vipir

                                                                    u7a
                                                                    &                                              Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                                   Service suisse d‘étaionnage
  Engineering AG                                                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                              Za
                                                                        ""lrl,.lu\“\                               Swiss Calibration Service



Accredited by the Swiss Federal Office of Metrology and Accreditation                            Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client




 Object



 Calibration procedure(s)




 Calibration date:


 Condition of the calibrated item



 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                      1D #                       Cal Date (Calibrated by, Certificate No.)           Scheduled Calibration
 Power meter E4419B                     GB41293874                 5—Apr—06 (METAS, No. 251—00557)                     Apr—07
 Power sensor E4412A                    MY41495277                 5—Apr—06 (METAS, No. 251—00557)                     Apr—07
 Power sensor E4412A                    MY41498087                 5—Apr—06 (METAS, No. 251—00557)                     Apr—07
 Reference 3 dB Attenuator              SN: S5054 (3c)             10—Aug—06 (METAS, No. 217—00592)                    Aug—07
 Reference 20 dB Attenuator             SN: $5086 (20b)            4—Apr—06 (METAS, No. 251—00558)                     Apr—07
 Reference 30 dB Attenuator             SN: $5129 (30b)            10—Aug—06 (METAS, No. 217—00593)                    Aug—07
 Reference Probe ES3DV2                 SN: 3013                   4—Jan—07 (SPEAG, No. ES3—3013_Jan07)                Jan—08
 DAE4                                   SN: 654                    21—Jun—06 (SPEAG, No. DAE4—654_JunO6)               Jun—07

 Secondary Standards                    ID #                       Check Date (in house)                               Scheduled Check
 RF generator HP 8648C                  US3642U01700               4—Aug—99 (SPEAG, in house check Nov—05)             In house check: Nov—07
 Network Analyzer HP 8753E              US37390585                 18—Oct—01 (SPEAG, in house check Oct—06)            In house check: Oct—07


                                        Name                                                                            Signature
 Calibrated by:




 Approved by:                          :NielsKuster

                                                                                                                       Issued: January 24, 2007
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.


Certificate No: EX3—3600_JanO7                                           Page 1 of 9


Calibration Laboratory of                                      aNll/                      Schwelizerischer Kalibrierdienst
Schmid & Partner                                                                          Service suisse d‘étalonnage
  Engineering AG                                             y                            Servizio svizzero di taratura




                                                                                 Iuf
                                                               Ty"    N\




                                                             x
Zeughausstrasse 43, 8004 Zurich, Switzerland                     +               8        Swiss Calibration Service
                                                                 l,'llulu\\‘\\


Accredited by the Swiss Federal Office of Metrology and Accreditation                  Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates



Glossary:
TSL                          tissue simulating liquid
NORMx,.y,z                   sensitivity in free space
ConF                         sensitivity in TSL / NORMx,y,z
DCP                          diode compression point
Polarization 4               o rotation around probe axis
Polarization 8               8 rotation around an axis that is in the plane normal to probe axis (at
                             measurement center), i.e., 8 = 0 is normal to probe axis

Calibration is Performed According to the Following Standards:
   a) IEEE Std 1528—2003, "IEEE Recommended Practice for Determining the Peak Spatial—
      Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
      Communications Devices: Measurement Techniques", December 2003
   b) CENELEC EN 50361, "Basic standard for the measurement of Specific Absorption Rate
       related to human exposure to electromagnetic fields from mobile phones (300 MHz — 3
      GHz), July 2001

Methods Applied and Interpretation of Parameters:
     NORMx,y,z: Assessed for E—field polarization 8 = 0 (f < 900 MHz in TEM—cell; f > 1800 MHz:
     R22 waveguide). NORMx,y,z are only intermediate values, i.e., the uncertainties of
     NORMx,y,z does not effect the E*—field uncertainty inside TSL (see below ConvF).
         NORM(P)x,y,z = NORMx,y,z * frequency_response (see Frequency Response Chart). This
         linearization is implemented in DASY4 software versions later than 4.2. The uncertainty of
         the frequency response is included in the stated uncertainty of ConvF.
         DCPx,y,z: DCP are numerical linearization parameters assessed based on the data of
         power sweep (no uncertainty required). DCP does not depend on frequency nor media.
         ConvF and Boundary Effect Parameters: Assessed in flat phantom using E—field (or
         Temperature Transfer Standard for f < 800 MHz) and inside waveguide using analytical field
         distributions based on power measurements for f > 800 MHz. The same setups are used for
         assessment of the parameters applied for boundary compensation (alpha, depth) of which
         typical uncertainty values are given. These parameters are used in DASY4 software to
         improve probe accuracy close to the boundary. The sensitivity in TSL corresponds to
         NORMx,y,z * ConvF whereby the uncertainty corresponds to that given for ConvF. A
         frequency dependent ConvF is used in DASY version 4.4 and higher which allows extending
         the validity from + 50 MHz to + 100 MHz.
         Spherical isotropy (3D deviation from isotropy): in a field of low gradients realized using a
         flat phantom exposed by a patch antenna.
         Sensor Offset: The sensor offset corresponds to the offset of virtual measurement center
         from the probe tip (on probe axis). No tolerance required.


Certificate No: EX3—3600_JanO7                                       Page 2 of 9


   EX3DV4 SN:3600                                                                January 24, 2007




                       Probe EX3DV4

                                           SN:3600
                                 Manufactured:                  January 10, 2007
                                 Calibrated:                    January 24, 2007


                                    Calibrated for DASY Systems
                                     (Note: non—compatible with DASY2 system!)




Certificate No: EX3—3600_JanO7                  Page 3 of 9


    EX3DV4 SN:3600                                                                                       January 24, 2007


    DASY — Parameters of Probe: EX3DV4 SN:3600

    Sensitivity in Free SpaceA                                                                 Diode Compression®

              NormX                    0.460 £10.1%                uV/(V/im)                  DCP X           90 mV
              NormYy                   0.470 £101%                 uV/(V/im)                  DCP Y           88 mV
              NormZ                    0.380 £10.1%                uV/(V/im)                  DCP Z           89 mV


    Sensitivity in Tissue Simulating Liquid (Conversion Factors)
   Please see Page 8.



    Boundary Effect
   TSL                       1810 MHz           Typical SAR gradient: 10 % per mm


              Sensor Center to Phantom Surface Distance                                       2.0 mm   3.0 mm
              SARpe [%)]            Without Correction Algorithm                                 4.5    3.5
              SARp, [%]             With Correction Algorithm                                    0.2    0.4


   TSL                      5800 MHz            Typical SAR gradient: 30 % per mm


              Sensor Center to Phantom Surface Distance                        .              2.0 mm   3.0 mm
              SARp, [%]             Without Correction Algorithm                                 3.5    2.0
              SARpe [%]             With Correction Algorithm                                    0.1    0.3



    Sensor Offset

              Probe Tip to Sensor Center                                                 1.0 mm




    The reported uncertainty of measurement is stated as the standard uncertainty of
    measurement muiltiplied by the coverage factor k=2, which for a normal distribution
    corresponds to a coverage probability of approximately 95%.


   * The uncertainties of NormX,Y,Z do not affect the E*—field uncertainty inside TSL (see Page 8).
    Numerical linearization parameter: uncertainty not required.




Certificate No: EX3—3600_JanO7                                Page 4 of 9


    EX3DV4 SN:3600                                                                                                      January 24, 2007



                                                                  Frequency Response of E—Field
                                                                       (TEM—Cell:ifi110 EXX, Waveguide: R22)


                                                 1.5

                                                 1.4

                                                 1.3
               Frequency response (normalized)
                                                 _2
                                                 N
                                                 _2
                                                 s




                                                 1.0

                                                 0.9

                                                 0.8
                                                 o   N




                                                 0.6

                                                 0.5
                                                         0          500       1000       1500       2000        2500    3000
                                                                                     f [MHz]
                                                             |            —@—TEM                —@— R22     J


                                                                 Uncertainty of Frequency Response of E—field: £ 6.3% (k=2)




Certificate No: EX3—3600_JanO7?                                                      Page 5 of 9


   EX3DV4 SN:3600                                                                    January 24, 2007



                                   Receiving Pattern (¢), 9 = 0°

                  f= 600 MHz, TEM ifi110EXX




                                                                                          | —@— 100 MHz
     Error [dB]




                                                                                            ——600 MHz
                                                                                          | —@— 1800 MHz |
                                                                                            —a&— 2500 MHz |




                                 Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




Certificate No: EX3—3600_JanO7                    Page 6 of 9


    EX3DV4 SN:3600                                                                                       January 24, 2007


                                                      Dynamic Range f(SARpeaq)
                                                            (Waveguide R22, f = 1800 MHz)



                                      1.E+7


                                      1.E+6


                                      1.E+5
              Input Signal [pV]




                                      1.E+4


                                      1.E+3


                                      1.E+2


                                      1.E+1


                                      1.E+0
                                         0.0001     0.001     0.01         0.1           1       10      100
                                                                     SAR [mW/icm*]

                                                  —@— not compensated               —@— compensated
                 Error [dB]
                                  J
                                  bst
                                  o
                                  6
                                  7*
                                      &
                                  t




                                       0.001         0.01            0.1             1           10            100
                                                                     SAR [mW/cm‘*]


                                                     Uncertainty of Linearity Assessment: £ 0.6% (k=2)




Certificate No: EX3—3600_JanO7                                        Page 7 of 9


    EX3DV4 SN:3600                                                                                                                January 24, 2007



                                               Conversion Factor Assessment

                             f= 1810 MHz, WGLS R22 (head)                                            f= 5800 MHz, WGLS R58 (head)   ‘
                            30 —i—       —      es 4                                               800       n EL   feieieaiges   _ ‘

                                                                                                   700                                                      |
                                                                                                                                                            |
     |                                                                                             600
     |
         SAR[mW/cm‘*] / W




                                                                                 SAR[mW/cm*] / W
     |
                                                                                                   500

                                                                             |                     400
                                                                             |
                                                                             |                     300
                                                                             |
                                                                             |                     200
                                                                             |
                                                                             |
                                                                             |                     100
                                                                             |
                                                                             ‘                       0
                                                                                                         0              10                20           30
                                                                             |
                                                                             y                       ns                                             c
                                               z[mm]                  ‘

                                               oooz                                                              ,                                          |
                            ‘ —@— Analytical   —0—Measurements               |                       @— Analytical           0—   Measurements |



   f [MHz] Validity [MHz]®                      TSL    Permittivity   Conductivity                       Alpha       Depth        ConvF Uncertainty
    1810                     £50/£100           Head   40.0£5%        1.40%5%                             0.20       1.01          7.02        £11.0% (k=2)

    1950                     £50/£100           Head   40.0£5%        1.40+5%                             0.26       1.05          6.59         £11.0% (k=2)

   2450                      £50/£100           Head   39.2£5%        1.80£5%                             0.44       1.00          6.37 £11.8% (k=2)

    5800                     £50/+ 100          Head   35.3 15%       5.27 + 5%                           0.37       1.65          4.34        £13.1% (k=2)




    1810                     £50/£100           Body   53.315%            1.52+5%                         0.24       1.06          6.85         £11.0% (k=2)

    1950                     £50/£100           Body   53.315%            1.52+5%                         0.16       1.35          6.54         £11.0% (k=2)

   2450                      £50/£100           Body   52.715%        1.95+5%                             0.42       1.00          6.31         £11.8% (k=2)

   5200                      £50/£100           Body   49.0£5%        5.30 £5%                            0.35       1.70          4.10        £13.1% (k=2)

   5500                      £50/+100           Body   48.6£5%        5.65 £5%                            0.32       1.70          3.95        £13.1% (k=2)

   5800                      £50/+100           Body   48.2+5%        6.00 £5%                            0.33       1.70          4.14        £13.1% (k=2)




   © The validity of £ 100 MHz only applies for DASY v4.4 and higher (see Page 2). The uncertainty is the RSS
   of the ConvF uncertainty at calibration frequency and the uncertainty for the indicated frequency band.




Certificate No: EX3—3600_Jan07                                    Page 8 of 9


   EX3DV4 SN:3600                                                                                 January 24, 2007



                                 Deviation from Isotropy in HSL
                                                Error (¢, 9), f = 900 MHz




                                                                                                      Error [dB]


                                                                     Ca _              _
                                  |i€—1.00——0.80 ©—0.80——0.60 ©—0.60——0.40 ©—0.40——0.20 ©—0.20—0.00
                                  |©0.00—0.20   ©0.20—0.40   ©0.40—0.60   ©0.60—0.80   IO.80-1.00}




                             Uncertainty of Spherical Isotropy Assessment: £ 2.6% (k=2)




Certificate No: EX3—3600_JanO7                        Page 9 of 9



Document Created: 2008-03-20 16:19:16
Document Modified: 2008-03-20 16:19:16

© 2024 FCC.report