SAR report part 4

FCC ID: KBCIX-4965AGN

RF Exposure Info

Download: PDF
FCCID_931064

                             Date(s) of Evaluation              Test Report Serial No.              Test Report Revision No.
                            November 02, 06, 2007             102407KBC-T866-S15WB                  Rev. 1.0 (Initial Release)
                            Test Report Issue Date               Description of Test(s)              RF Exposure Category
                                 March 20, 2008                Specific Absorption Rate                General Population               Certificate No. 2470.01


APPENDIX F - SYSTEM VALIDATION




Company:            General Dynamics Itronix Corporation                     FCC ID:          KBCIX-4965AGN                   IC:            1943A-4965AGN
 Model(s):         IX350        DUT Type:           Tablet PC with 802.11a/b/g/n WLAN & Co-located Bluetooth
2008 Celltech Labs Inc.    This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 70 of 72


                                    Date of Evaluation:               June 08, 2007              Document Serial No.:            SV2450M-060807-R1.4
                                   Evaluation Type:        System Validation          Validation Dipole:       2450 MHz         Fluid Type:      Body




                                                 2450 MHz SYSTEM VALIDATION



                     Type:                                                  2450 MHz Validation Dipole




                     Asset Number:                                                               00025




                     Serial Number:                                                                150




                     Place of Validation:                                             Celltech Labs Inc.




                     Date of Validation:                                                  June 08, 2007




         Celltech Labs Inc. certifies that the 2450 MHz System Validation was performed on the date indicated above.




                     Performed by:                                                    Cheri Frangiadakis



                     Approved by:                                                         Sean Johnston




                                       Celltech Labs Inc. 21-364 Lougheed Rd., Kelowna, B.C. V1X 7R8 Canada
                                       Tel. 250-765-7650 x Fax. 250-765-7645 x e-mail: info@celltechlabs.com
                                                                www.celltechlabs.com

2007 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 1 of 11


                                          Date of Evaluation:               June 08, 2007              Document Serial No.:            SV2450M-060807-R1.4
                                         Evaluation Type:        System Validation          Validation Dipole:       2450 MHz          Fluid Type:   Body



     1. Dipole Construction & Electrical Characteristics

     The validation dipole was constructed in accordance with the requirements specified in IEEE Standard 1528-
     2003 and International Standard IEC 62209-1:2005. The electrical properties were measured using an HP
     8753ET Network Analyzer. The network analyzer was calibrated to the validation dipole N-type connector
     feed point using an HP85032E Type N calibration kit. The dipole was placed parallel to a planar phantom at
     a separation distance of 10.0mm from the simulating fluid using a loss-less dielectric spacer. The measured
     input impedance is:


                          Feed point impedance at 2450 MHz                                      Re{Z} = 45.100:
                                                                                                Im{Z} = 3.5605:

                          Return Loss at 2450 MHz                                               -23.411dB




                                                Reference dipole - basic mechanical parameters




2007 Celltech Labs Inc.      This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 2 of 11


                                                                             a Jun zear    egrase2s
               En3 rrl          Loo       10 aormer o se                  arm2sea ap      2 «s0.000 cce mz




               §



                                  ESX                                                         ~—
                                          r—_                                       |_._—4
                                                                           L4




                             céiimcr 2 45a.500 soe hiz                             sFai a60.000 se wis

                                                                               8   Jun 207.    @B:39:54
               Emm rrl           a ucrs            is 48100 a   a.sses a_zonge pi             2 «s0.000 ooo nz

               +

               tor




                   +




                               ceiter 2 «s0.o00 ons Mz                               sran «a0.a00 on it



esces caus n           inuoourremie ux o ue reprouui i wntore n in par wiouie prin wintent prvinimwin or verien taus n   rage o on i1


                                        Date of Evaluation:               June 08, 2007              Document Serial No.:            SV2450M-060807-R1.4
                                       Evaluation Type:        System Validation          Validation Dipole:       2450 MHz          Fluid Type:   Body



     3. Validation Dipole Dimensions

                          Frequency (MHz)                         L (mm)                       H (mm)                        D (mm)
                                    300                             396.0                        250.0                           6.0
                                    450                             270.0                        167.0                           6.0
                                    835                             161.0                         89.8                           3.6
                                    900                             149.0                         83.3                           3.6
                                   1450                             89.1                          51.7                           3.6
                                   1800                             72.0                          41.7                           3.6
                                   1900                             68.0                          39.5                           3.6
                                   2000                             64.5                          37.5                           3.6
                                   2450                             51.5                          30.4                           3.6
                                   3000                             41.5                          25.0                           3.6


     4. Validation Phantom

     The validation phantom is the SAM (Specific Anthropomorphic Mannequin) phantom manufactured by
     Schmid & Partner Engineering AG. The SAM phantom is a Fiberglass shell integrated in a wooden table.
     The shape of the shell corresponds to the phantom defined by SCC34-SC2. It enables the dosimetric
     evaluation of left and right hand phone usage as well as body mounted usage at the flat phantom region. A
     cover prevents evaporation of the liquid. Reference markings on the phantom allow the complete setup of all
     predefined phantom positions and measurement grids by manually teaching three points in the robot.

                                                Shell Thickness:                  2.0 ± 0.1 mm
                                                Filling Volume:                   Approx. 25 liters
                                                Dimensions:                       50 cm (W) x 100 cm (L)




                                                                           SAM Phantom




                                                                     Fluid Depth (t 15.0 cm)




2007 Celltech Labs Inc.    This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 4 of 11




(Celltech




            raye o o


                                       Date of Evaluation:               June 08, 2007              Document Serial No.:            SV2450M-060807-R1.4
                                      Evaluation Type:        System Validation          Validation Dipole:          2450 MHz       Fluid Type:   Body



     7. SAR Measurement

     Measurements were made at the planar section of the SAM phantom using a dosimetric E-field probe
     EX3DV4 (S/N: 3600, conversion factor 6.31). The SAR measurement was performed with the E-field probe
     in mechanical detection mode only. The setup and determination of the forward power into the dipole was
     performed using the procedures described below.

     First the power meter PM1 (including attenuator Att1) is connected to the cable to measure the forward
     power at the location of the dipole connector (X). The signal generator is adjusted for the desired forward
     power at the dipole connector (taking into account the attenuation of Att1) as read by power meter PM2.
     After connecting the cable to the dipole, the signal generator is readjusted for the same reading at power
     meter PM2. If the signal generator does not allow adjustment in 0.01dB steps, the remaining difference at
     PM2 must be taken into consideration. PM3 records the reflected power from the dipole to ensure that the
     value is not changed from the previous value. The reflected power should be 20dB below the forward
     power.




                                                                                                   3D Probe positioner

                                                      d
                                                                                         Field probe
                                                                                                            Flat Phantom




                                                                                                            Dipole




                                                               Dir.Coupler
            Signal          Amp          Low        3dB                                                 x
            Generator                    Pass                                        Cable                       Att1
                                                    Att3
                                                                                                                       PM1

                                                                    Att2    PM3



                                                              PM2




                                                  System Validation Measurement Setup Diagram




2007 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 7 of 11


                                          Date of Evaluation:               June 08, 2007              Document Serial No.:            SV2450M-060807-R1.4
                                         Evaluation Type:        System Validation           Validation Dipole:      2450 MHz          Fluid Type:   Body



     8. Measurement Conditions

            The SAM phantom was filled with 2450 MHz Body tissue simulant.
            Relative Permittivity:             50.1 (-4.9% deviation from target)
            Conductivity:                      1.99 mho/m (+2.1% deviation from target)
            Fluid Temperature:                 21.5 qC (Start of Test) / 21.2 qC (End of Test)
            Fluid Depth:                       t 15.0 cm

            Environmental Conditions:
            Ambient Temperature: 22.7 qC
            Barometric Pressure: 101.1 kPa
            Humidity:              31 %

            The 2450 MHz Body tissue simulant consisted of the following ingredients:

                            Ingredient                                            Percentage by weight
                               Water                                                         69.98%
                          Glycol Monobutyl                                                   30.00%
                                Salt                                                          0.02%
            IEEE Target Dielectric Parameters:                      Hr = 52.7 (+/-5%)             V = 1.95 S/m (+/-5%)



     9. System Validation SAR Results

            SAR @ 0.25W Input averaged over 1g (W/kg)                                 SAR @ 1W Input averaged over 1g (W/kg)
               SPEAG Target                 Measured           Deviation              SPEAG Target                   Measured            Deviation

              12.8           +/- 10%            13.4              +4.7%               51.2           +/- 10%             53.6              +4.7%

           SAR @ 0.25W Input averaged over 10g (W/kg)                                SAR @ 1W Input averaged over 10g (W/kg)
               SPEAG Target                 Measured           Deviation              SPEAG Target                   Measured            Deviation

              5.93           +/- 10%            6.03              +1.7%               23.7           +/- 10%             24.1              +1.7%




2007 Celltech Labs Inc.      This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 8 of 11


                                           Date of Evaluation:               June 08, 2007              Document Serial No.:            SV2450M-060807-R1.4
                                          Evaluation Type:        System Validation          Validation Dipole:       2450 MHz          Fluid Type:   Body



     System Validation - 2450 MHz Dipole - June 8, 2007
     DUT: Dipole 2450 MHz; Asset: 00025; Serial: 150

     Ambient Temp: 22.7qC; Fluid Temp: 21.5qC; Barometric Pressure: 101.1 kPa; Humidity: 31%

     Communication System: CW
     Forward Conducted Power: 250 mW
     Frequency: 2450 MHz; Duty Cycle: 1:1
                                                                                                  3
     Medium: M2450 Medium parameters used: f = 2450 MHz; ı = 1.99 mho/m; İr = 50.1; ȡ = 1000 kg/m

     - Probe: EX3DV4 - SN3600; ConvF(6.31, 6.31, 6.31); Calibrated: 24/01/2007
     - Sensor-Surface: 2 mm (Mechanical Surface Detection)
     - Electronics: DAE4 Sn353; Calibrated: 21/06/2006
     - Phantom: SAM 4.0; Type: Fiberglas; Serial: 1033
     - Measurement SW: DASY4, V4.7 Build 44; Postprocessing SW: SEMCAD, V1.8 Build 171

     2450 MHz System Validation/Area Scan (6x10x1):
     Measurement grid: dx=10mm, dy=10mm
     Maximum value of SAR (measured) = 13.1 mW/g

     2450 MHz System Validation/Zoom Scan (7x7x7)/Cube 0:
     Measurement grid: dx=5mm, dy=5mm, dz=5mm
     Reference Value = 91.9 V/m; Power Drift = -0.128 dB
     Peak SAR (extrapolated) = 28.6 W/kg
     SAR(1 g) = 13.4 mW/g; SAR(10 g) = 6.03 mW/g
     Maximum value of SAR (measured) = 15.5 mW/g




                          




2007 Celltech Labs Inc.       This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 9 of 11


                                       Date of Evaluation:               June 08, 2007              Document Serial No.:            SV2450M-060807-R1.4
                                      Evaluation Type:        System Validation          Validation Dipole:       2450 MHz          Fluid Type:   Body




     10. Measured Fluid Dielectric Parameters
            System Validation - 2450 MHz (Body)
            ************************************************************
            Celltech Labs Inc.
            Test Result for UIM Dielectric Parameter
            Fri 08/Jun/2007
            Frequency (GHz)
            FCC_eH FCC Bulletin 65 Supplement C (June 2001) Limits for Head Epsilon
            FCC_sH FCC Bulletin 65 Supplement C (June 2001) Limits for Head Sigma
            FCC_eB FCC Limits for Body Epsilon
            FCC_sB FCC Limits for Body Sigma
            Test_e Epsilon of UIM
            Test_s Sigma of UIM
            ************************************************************
            Freq                 FCC_eB FCC_sB Test_e Test_s
            2.3500               52.83 1.85          50.39 1.89
            2.3600               52.82 1.86          50.32 1.90
            2.3700               52.81 1.87          50.28 1.91
            2.3800               52.79 1.88          50.28 1.93
            2.3900               52.78 1.89          50.31 1.94
            2.4000               52.77 1.90          50.26 1.95
            2.4100               52.75 1.91          50.24 1.96
            2.4200               52.74 1.92          50.21 1.96
            2.4300               52.73 1.93          50.21 1.98
            2.4400               52.71 1.94          50.13 1.99
            2.4500               52.70 1.95          50.09 1.99
            2.4600               52.69 1.96          50.01 2.03
            2.4700               52.67 1.98          50.10 2.03
            2.4800               52.66 1.99          50.12 2.05
            2.4900               52.65 2.01          50.09 2.07
            2.5000               52.64 2.02          50.08 2.07
            2.5100               52.62 2.04          50.03 2.08
            2.5200               52.61 2.05          50.02 2.09
            2.5300               52.60 2.06          49.93 2.10
            2.5400               52.59 2.08          49.87 2.11
            2.5500               52.57 2.09          49.78 2.13

2007 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 10 of 11


                                           Date of Evaluation:               June 08, 2007              Document Serial No.:            SV2450M-060807-R1.4
                                          Evaluation Type:        System Validation          Validation Dipole:       2450 MHz          Fluid Type:       Body



     11. Measurement Uncertainties
                                            UNCERTAINTY BUDGET FOR SYSTEM VALIDATION
                                                 Uncertainty                                                                        Uncertainty
                                                                        Probability                                      ci
                Error Description                  Value                                            Divisor                           Value            Vi or Veff
                                                                        Distribution                                     1g
                                                    ±%                                                                               ±% (1g)

         Measurement System
         Probe calibration (2450 MHz)                  5.9                 Normal                      1                   1             5.9               f
         Axial isotropy of the probe                   4.7              Rectangular             1.732050808                1             2.7               f
         Spherical isotropy of the probe                0               Rectangular             1.732050808                1             0.0               f
         Spatial resolution                             0               Rectangular             1.732050808                1             0.0               f
         Boundary effects                              0.2              Rectangular             1.732050808                1             0.1               f
         Probe linearity                               4.7              Rectangular             1.732050808                1             2.7               f
         Detection limit                                1               Rectangular             1.732050808                1             0.6               f
         Readout electronics                           0.3                 Normal                      1                   1             0.3               f
         Response time                                  0               Rectangular             1.732050808                1             0.0               f
         Integration time                               0               Rectangular             1.732050808                1             0.0               f
         RF ambient conditions                          3               Rectangular             1.732050808                1             1.7               f
         Mech. constraints of robot                    0.4              Rectangular             1.732050808                1             0.2               f
         Probe positioning                             2.9              Rectangular             1.732050808                1             1.7               f
         Extrapolation & integration                    1               Rectangular             1.732050808                1             0.6               f
         Dipole
         Dipole Positioning                             2                  Normal               1.732050808                1             1.2               f
         Power & Power Drift                           4.7                 Normal               1.732050808                1             2.7               f
         Phantom and Setup
         Phantom uncertainty                            4               Rectangular             1.732050808                1             2.3               f
         Liquid conductivity (target)                   5               Rectangular             1.732050808             0.64             1.8               f
         Liquid conductivity (measured)                2.1                 Normal                      1                0.64             1.3               f
         Liquid permittivity (target)                   5               Rectangular             1.732050808              0.6             1.7               f
         Liquid permittivity (measured)                4.9                 Normal                      1                 0.6             2.9               f
         Combined Standard Uncertainty                                                                                                   9.33
         Expanded Uncertainty (k=2)                                                                                                     18.66
                Measurement Uncertainty Table in accordance with IEEE Standard 1528-2003 and IEC Standard 62209-1:2005

     12. Test Equipment List

                          TEST EQUIPMENT                           ASSET NO.            SERIAL NO.            DATE OF CAL.             CAL. DUE DATE
              SPEAG DASY4 Measurement Server                           00158                  1078                   N/A                        N/A
                            SPEAG Robot                                00046              599396-01                  N/A                        N/A
                            SPEAG DAE4                                 00019                  353                  21Jun06                   21Jun07
                  SPEAG EX3DV4 E-Field Probe                           00213                  3600                 24Jan07                   24Jan08
                   2450 MHz Validation Dipole                          00025                  150                  08Jun07                   08Jun08
                  SPEAG SAM Phantom V4.0C                              00154                  1033                   N/A                        N/A
                ALS-PR-DIEL Dielectric Probe Kit                       00160              260-00953                  N/A                        N/A
                  Gigatronics 8652A Power Meter                        00007               1835272                26Mar07                    26Mar08
               Gigatronics 80701A Power Sensor                         00014               1833699                 22Jan07                   22Jan08
               Gigatronics 80701A Power Sensor                         00109               1834366                26Mar07                    26Mar08
                  HP 8753ET Network Analyzer                           00134             US39170292                20Apr07                   20Apr08
                   HP 8648D Signal Generator                           00005             3847A00611                  NCR                        NCR
           Amplifier Research 5S1G4 Power Amplifier                    00106                 26235                   NCR                        NCR


2007 Celltech Labs Inc.       This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.         Page 11 of 11


                                Date of Evaluation:            May 18, 2007                  Document Serial No.:                 SV5200M-051807-R1.2
                                 Evaluation Type:           System Validation          Validation Dipole:        5200 MHz         Fluid Type:    Body




                                                  5200 MHz SYSTEM VALIDATION




                      Type:                                                  5200 MHz Validation Dipole




                      Asset Number:                                                               00126



                      Serial Number:                                                               1031




                      Place of Validation:                                            Celltech Labs Inc.




                      Date of Validation:                                                   May 18, 2007



           Celltech Labs Inc. certifies that the 5200 MHz System Validation was performed on the date indicated above.




                      Performed by:                                                    Cheri Frangiadakis




                      Approved by:                                                         Sean Johnston




                                        Celltech Labs Inc. 21-364 Lougheed Rd., Kelowna, B.C. V1X 7R8 Canada
                                        Tel. 250-765-7650 x Fax. 250-765-7645 x e-mail: info@celltechlabs.com
                                                                 www.celltechlabs.com

2007 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.     Page 1 of 11


                               Date of Evaluation:            May 18, 2007                   Document Serial No.:                 SV5200M-051807-R1.2
                                 Evaluation Type:           System Validation          Validation Dipole:        5200 MHz         Fluid Type:     Body



    1. Dipole Construction & Electrical Characteristics

    The validation dipole was manufactured by Schmid and Partner Engineering AG. The electrical properties
    were measured using an HP 8753ET Network Analyzer. The network analyzer was calibrated to the
    validation dipole N-type connector feed point using an HP85032E Type N calibration kit. The dipole was
    placed parallel to a planar phantom at a separation distance of 10.0mm from the simulating fluid using a
    loss-less dielectric spacer. The measured input impedance is:


                      Feed point impedance at 5200 MHz                                     Re{Z} = 50.324:
                                                                                           Im{Z} = 3.5215:

                      Return Loss at 5200 MHz                                              -28.311 dB




                                           Reference dipole - basic mechanical parameters




2007 Celltech Labs Inc.    This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 2 of 11


                                                   a8 nay 2eo7. oorsorar
EBM er.     oo       10 corser o an                —21.264 ds s nemeos coe iz

+
                                                                                  CHL Nankers
Sn                                                                                 22,509 oo
t          5.8        GHz                                                           Sedaa ue
                                                                                   ~2a.0uon
                                                                                  Szeden onz

tys
18


    &



        L__]
                                                                 £2=1"
                                fv“?/\

                            4



          Staey 1 500.000 one is                        stor © con.e0e aoe mis

                                                  18 may 2007 eoranss
hn enc      a ucrs              asasose   somes saraepd       s see,c00 cee nz

*
                                                                                    chit narkers
&s                                                                                       sueer a
                                                                                        —rdoar a
&                                                                                    s.sdbon tz


fvs
is


    &




          centcr s 50.000 c00 nz                         spou 1 006.c00 006 miz


                                 Date of Evaluation:            May 18, 2007                   Document Serial No.:                 SV5200M-051807-R1.2
                                   Evaluation Type:           System Validation          Validation Dipole:        5200 MHz         Fluid Type:     Body



    3. Validation Dipole Dimensions


                          Frequency (MHz)                      L (mm)                        H (mm)                        D (mm)
                                  300                            396.0                         250.0                          6.0
                                  450                            270.0                         167.0                          6.0
                                  835                            161.0                          89.8                          3.6
                                  900                            149.0                          83.3                          3.6
                                 1450                             89.1                          51.7                          3.6
                                 1800                             72.0                          41.7                          3.6
                                 1900                             68.0                          39.5                          3.6
                                 2000                             64.5                          37.5                          3.6
                                 2450                             51.5                          30.4                          3.6
                                 3000                             41.5                          25.0                          3.6
                             5200 - 5800                          20.6                         40.65                          3.6


    4. Validation Phantom

    The validation phantom is the SAM (Specific Anthropomorphic Mannequin) phantom manufactured by
    Schmid & Partner Engineering AG. The SAM phantom is a Fiberglass shell integrated in a wooden table.
    The shape of the shell corresponds to the phantom defined by SCC34-SC2. It enables the dosimetric
    evaluation of left and right hand phone usage as well as body mounted usage at the flat phantom region. A
    cover prevents evaporation of the liquid. Reference markings on the phantom allow the complete setup of all
    predefined phantom positions and measurement grids by manually teaching three points in the robot.

                   Shell Thickness: 2.0 ± 0.1 mm
                   Filling Volume: Approx. 25 liters
                   Dimensions:      50 cm (W) x 100 cm (L)




                                  SAM Phantom                                               Fluid Depth (t 15.0 cm)




2007 Celltech Labs Inc.      This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 4 of 11


(‘Celltech




                                Date of Evaluation:          May 18, 2007                   Document Serial No.:                 SV5200M-051807-R1.2
                                 Evaluation Type:          System Validation          Validation Dipole:         5200 MHz        Fluid Type:     Body



    7. SAR Measurement

    Measurements were made using a dosimetric E-field probe EX3DV4 (S/N: 3600, Conversion Factor 4.10).
    The SAR measurement was performed with the E-field probe in mechanical detection mode only. The setup
    and determination of the forward power into the dipole was performed using the procedures described
    below.

    First the power meter PM1 (including attenuator Att1) is connected to the cable to measure the forward
    power at the location of the dipole connector (X). The signal generator is adjusted for the desired forward
    power at the dipole connector (taking into account the attenuation of Att1) as read by power meter PM2.
    After connecting the cable to the dipole, the signal generator is readjusted for the same reading at power
    meter PM2. If the signal generator does not allow adjustment in 0.01dB steps, the remaining difference at
    PM2 must be taken into consideration. PM3 records the reflected power from the dipole to ensure that the
    value is not changed from the previous value. The reflected power should be 20dB below the forward
    power.




                                                                                               3D Probe positioner

                                                  d
                                                                                     Field probe
                                                                                                        Flat Phantom




                                                                                                        Dipole




                                                           Dir.Coupler
          Signal          Amp        Low        3dB                                                 x
          Generator                  Pass                                        Cable                       Att1
                                                Att3
                                                                                                                  PM1

                                                                Att2    PM3



                                                          PM2




                                              System Validation Measurement Setup Diagram




2007 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 7 of 11


                                 Date of Evaluation:            May 18, 2007                   Document Serial No.:                 SV5200M-051807-R1.2
                                   Evaluation Type:           System Validation          Validation Dipole:        5200 MHz         Fluid Type:     Body



    8. Measurement Conditions
           The SAM phantom was filled with 5200 MHz Body tissue simulant.

           Relative Permittivity:           44.6 (-9.0% deviation from target)
           Conductivity:                    5.52 mho/m (+4.2% deviation from target)
           Fluid Temperature:               23.6 qC (Start of Test) / 23.7 qC (End of Test)
           Fluid Depth:                     t 15.0 cm

           Environmental Conditions:
           Ambient Temperature: 25.0qC
           Humidity:              48%
           Barometric Pressure:   101.1 kPa

           The 5200 MHz Body tissue simulant consisted of the following ingredients:

                             Ingredient                                         Percentage by weight
                                Water                                                     64 - 78%
                             Mineral Oil                                                  11 - 18%
                             Emulsifiers                                                   9 - 15%
                          Additives and Salt                                                2 - 3%
              IEEE Target Dielectric Parameters:                    Hr = 49.0 (+/-10%)           V = 5.30 S/m (+/-5%)



    9. System Validation SAR Results

            SAR @ 0.25W Input averaged over 1g (W/kg)                                SAR @ 1W Input averaged over 1g (W/kg)
               SPEAG Target                Measured            Deviation              SPEAG Target                 Measured           Deviation
             18.0           +/- 10%             18.2             +1.2%              72.0           +/- 10%             72.8             +1.1%
           SAR @ 0.25W Input averaged over 10g (W/kg)                               SAR @ 1W Input averaged over 10g (W/kg)
               SPEAG Target                Measured            Deviation              SPEAG Target                 Measured           Deviation
             5.03           +/- 10%             5.12             +1.8%             20.12           +/- 10%             20.48            +1.8%
         Extrapolated Peak SAR              SPEAG Target              71.2         +/- 15%       Measured              72.7             +2.1%




2007 Celltech Labs Inc.      This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 8 of 11


                                  Date of Evaluation:            May 18, 2007                   Document Serial No.:                 SV5200M-051807-R1.2
                                    Evaluation Type:           System Validation          Validation Dipole:        5200 MHz         Fluid Type:     Body



    System Validation - 5200 MHz Dipole - May 18, 2007
    DUT: Dipole 5GHz; Model: D5GHzV2; Asset: 00126; Serial: 1031

    Ambient Temp: 25.0ºC; Fluid Temp: 23.6ºC; Barometric Pressure: 101.1 kPa; Humidity: 48%

    Communication System: CW
    Forward Conducted Power: 250mW
    Frequency: 5200 MHz; Duty Cycle: 1:1
                                                                                                      3
    Medium: M5200-5800 Medium parameters used: f = 5200 MHz; ı = 5.52 mho/m; İr = 44.6; ȡ = 1000 kg/m

    - Probe: EX3DV4 - SN3600; ConvF(4.1, 4.1, 4.1); Calibrated: 24/01/2007
    - Sensor-Surface: 2 mm (Mechanical Surface Detection)
    - Electronics: DAE4 Sn353; Calibrated: 21/06/2006
    - Phantom: SAM 4.0; Type: Fiberglas; Serial: 1033
    - Measurement SW: DASY4, V4.7 Build 44; Postprocessing SW: SEMCAD, V1.8 Build 171

    5200 MHz System Validation/Area Scan (9x13x1):
    Measurement grid: dx=5mm, dy=5mm
    Maximum value of SAR (measured) = 48.3 mW/g

    5200 MHz System Validation/Zoom Scan (7x7x9)/Cube 0:
    Measurement grid: dx=4mm, dy=4mm, dz=2.5mm
    Reference Value = 86.3 V/m; Power Drift = 0.100 dB
    Peak SAR (extrapolated) = 72.7 W/kg
    SAR(1 g) = 18.2 mW/g; SAR(10 g) = 5.12 mW/g
    Maximum value of SAR (measured) = 36.1 mW/g




                          




2007 Celltech Labs Inc.       This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 9 of 11


                              Date of Evaluation:            May 18, 2007                   Document Serial No.:                 SV5200M-051807-R1.2
                                Evaluation Type:           System Validation          Validation Dipole:        5200 MHz         Fluid Type:     Body




    10. Measured Fluid Dielectric Parameters
           System Validation - 5200 MHz (Body)
           ************************************************************
           Celltech Labs Inc.
           Test Result for UIM Dielectric Parameter
           Tue 18/May/2007
           Frequency (GHz)
           FCC_eH FCC Bulletin 65 Supplement C (June 2001) Limits for Head Epsilon
           FCC_sH FCC Bulletin 65 Supplement C (June 2001) Limits for Head Sigma
           FCC_eB FCC Limits for Body Epsilon
           FCC_sB FCC Limits for Body Sigma
           Test_e Epsilon of UIM
           Test_s Sigma of UIM
           ************************************************************
           Freq                 FCC_eB FCC_sB Test_e Test_s
           5.1000               49.15 5.18          44.46 5.40
           5.1100               49.14 5.19          44.42 5.39
           5.1200               49.12 5.21          44.40 5.36
           5.1300               49.11 5.22          44.40 5.40
           5.1400               49.10 5.23          44.38 5.39
           5.1500               49.08 5.24          44.37 5.38
           5.1600               49.07 5.25          44.46 5.44
           5.1700               49.06 5.26          44.35 5.46
           5.1800               49.04 5.28          44.31 5.47
           5.1900               49.03 5.29          44.38 5.51
           5.2000               49.01 5.30          44.55 5.52
           5.2100               49.00 5.31          44.40 5.53
           5.2200               48.99 5.32          44.23 5.48
           5.2300               48.97 5.33          44.20 5.51
           5.2400               48.96 5.35          44.14 5.54
           5.2500               48.95 5.36          44.15 5.58
           5.2600               48.93 5.37          44.19 5.56
           5.2700               48.92 5.38          44.16 5.57
           5.2800               48.91 5.39          44.01 5.59
           5.2900               48.89 5.40          44.00 5.62
           5.3000               48.88 5.42          43.98 5.63


2007 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 10 of 11


                                  Date of Evaluation:            May 18, 2007                   Document Serial No.:                 SV5200M-051807-R1.2
                                    Evaluation Type:           System Validation          Validation Dipole:        5200 MHz         Fluid Type:          Body



    11. Measurement Uncertainties

                                        UNCERTAINTY BUDGET FOR SYSTEM VALIDATION
                                                Uncertainty                                                                  Uncertainty
                                                                    Probability                                    ci
                Error Description                 Value                                       Divisor                          Value            Vi or Veff
                                                                    Distribution                                   1g
                                                   ±%                                                                         ±% (1g)

         Measurement System
         Probe calibration (5200 MHz)                6.55               Normal                    1                 1            6.55                f
         Axial isotropy of the probe                  4.7            Rectangular           1.732050808              1             2.7                f
         Spherical isotropy of the probe              9.6            Rectangular           1.732050808              1             5.5                f
         Spatial resolution                            0             Rectangular           1.732050808              1             0.0                f
         Boundary effects                             0.1            Rectangular           1.732050808              1             0.1                f
         Probe linearity                              4.7            Rectangular           1.732050808              1             2.7                f
         Detection limit                               1             Rectangular           1.732050808              1             0.6                f
         Readout electronics                          0.3               Normal                    1                 1             0.3                f
         Response time                                 0             Rectangular           1.732050808              1             0.0                f
         Integration time                              0             Rectangular           1.732050808              1             0.0                f
         RF ambient conditions                         3             Rectangular           1.732050808              1             1.7                f
         Mech. constraints of robot                   0.8            Rectangular           1.732050808              1             0.5                f
         Probe positioning                            5.7            Rectangular           1.732050808              1             3.3                f
         Extrapolation & integration                   4             Rectangular           1.732050808              1             2.3                f
         Dipole
         Dipole positioning                            2             Rectangular           1.732050808              1             1.2                f
         Power & Power Drift                          4.7            Rectangular           1.732050808              1             2.7                f

         Phantom and Setup
         Phantom uncertainty                           4             Rectangular           1.732050808              1             2.3                f
         Liquid conductivity (target)                  5             Rectangular           1.732050808            0.64            1.8                f
         Liquid conductivity (measured)               4.2               Normal                    1               0.64            2.7                f
         Liquid permittivity (target)                 10             Rectangular           1.732050808            0.6             3.5                f
         Liquid permittivity (measured)                9                Normal                    1               0.6             5.4                f
         Combined Standard Uncertainty                                                                                           13.19
         Expanded Uncertainty (k=2)                                                                                              26.38
            Measurement Uncertainty Table in accordance with IEEE Standard 1528-2003 and IEC Standard 62209-1:2005


    12. Test Equipment List

                     TEST EQUIPMENT                             ASSET NO.            SERIAL NO.            DATE OF CAL.             CAL. DUE DATE
            SPEAG DASY4 Measurement Server                          00158                  1078                    N/A                       N/A
                           SPEAG Robot                              00046              599396-01                   N/A                       N/A
                           SPEAG DAE4                               00019                  353                  21Jun06                   21Jun07
                SPEAG EX3DV4 E-Field Probe                          00213                  3600                 24Jan07                   24Jan08
                SPEAG 5GHz Validation Dipole                        00126                  1031                09May07                    09May08
                  SPEAG SAM Phantom V4.0C                           00154                  1033                    N/A                       N/A
               ALS-PR-DIEL Dielectric Probe Kit                     00160              260-00953                   N/A                       N/A
                Gigatronics 8652A Power Meter                       00007               1835272                 26Mar07                   26Mar08
              Gigatronics 80701A Power Sensor                       00014               1833699                 22Jan07                   22Jan08
              Gigatronics 80701A Power Sensor                       00109               1834366                 26Mar07                   26Mar08
                 HP 8753ET Network Analyzer                         00134             US39170292                20Apr07                   20Apr08
            Nextec NB00383 Microwave Amplifier                      00151                  0535                   NCR                       NCR
         Rohde & Schwarz SMR20 Signal Generator                     00006                100104                   NCR                       NCR



2007 Celltech Labs Inc.       This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.           Page 11 of 11


                               Date of Evaluation:            May 10, 2007                   Document Serial No.:                 SV5800M-051007-R1.2
                                 Evaluation Type:           System Validation          Validation Dipole:        5800 MHz         Fluid Type:     Body




                                                  5800 MHz SYSTEM VALIDATION




                      Type:                                                  5800 MHz Validation Dipole




                      Asset Number:                                                              00126



                      Serial Number:                                                               1031




                      Place of Validation:                                            Celltech Labs Inc.




                      Date of Validation:                                                  May 10, 2007



           Celltech Labs Inc. certifies that the 5800 MHz System Validation was performed on the date indicated above.




                      Performed by:                                                   Cheri Frangiadakis




                      Approved by:                                                        Sean Johnston




                                        Celltech Labs Inc. 21-364 Lougheed Rd., Kelowna, B.C. V1X 7R8 Canada
                                        Tel. 250-765-7650 x Fax. 250-765-7645 x e-mail: info@celltechlabs.com
                                                                 www.celltechlabs.com

2007 Celltech Labs Inc.    This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.     Page 1 of 11


                               Date of Evaluation:            May 10, 2007                   Document Serial No.:                 SV5800M-051007-R1.2
                                 Evaluation Type:           System Validation          Validation Dipole:        5800 MHz         Fluid Type:     Body



    1. Dipole Construction & Electrical Characteristics

    The validation dipole was manufactured by Schmid and Partner Engineering AG. The electrical properties
    were measured using an HP 8753ET Network Analyzer. The network analyzer was calibrated to the
    validation dipole N-type connector feed point using an HP85032ET Type N calibration kit. The dipole was
    placed parallel to a planar phantom at a separation distance of 10.0mm from the simulating fluid using a
    loss-less dielectric spacer. The measured input impedance is:


                      Feed point impedance at 5800 MHz                                     Re{Z} = 58.436:
                                                                                           Im{Z} = 5.3613:

                      Return Loss at 5800 MHz                                              -21.264 dB




                                           Reference dipole - basic mechanical parameters




2007 Celltech Labs Inc.    This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.     Page 2 of 11


«Célltech                                        i                                                 f
                                                                 10 Hay 2607 onsz or
   CBB erc           coo         10 as/rer o ce                 21—21.254 an   s soe.one ooo niz

   x
                                                                                                       CHt Merkers
   gue                                                                                                 a—22.509 d
   :                 9.8           GHz                                                                 5.50000 olz
                                                                                                       a—20.300 ap
                                                                                                       S.zen00 oz

   ov
   16°

       a



           ——I                                                                              _
                                                                                 &
                                             /_\\-/“—fl—¥/—\

                                         7




                   Start 4 s00.000 000 Niz                             STop o 200.000 a08 miiz

                                                                10 may 2607 oscsiiss
           gan en            a ucre            mseasse sostse cera2pi       s ace.ceo aon nz

           a
                                                                                                       CHL Harkers
                                                                                                         4: 51.047 a
           Bke
           to
                                   /                                                                       ie a
                                                                                                        250500 tha
                                                                                                         a sa.a2g
                                                                                                            a490 2o
                                                                                                        s.20d08 the
           hy
           1s°

               1




                           cenitcr 5 «50.000 o00 nite                     spei 1 e00.000 000 mtz


                                  Date of Evaluation:            May 10, 2007                   Document Serial No.:                 SV5800M-051007-R1.2
                                    Evaluation Type:           System Validation          Validation Dipole:        5800 MHz         Fluid Type:     Body



    3. Validation Dipole Dimensions

                          Frequency (MHz)                      L (mm)                       H (mm)                        D (mm)
                                 300                             396.0                         250.0                          6.0
                                 450                             270.0                         167.0                          6.0
                                 835                             161.0                         89.8                           3.6
                                 900                             149.0                         83.3                           3.6
                                1450                             89.1                          51.7                           3.6
                                1800                             72.0                          41.7                           3.6
                                1900                             68.0                          39.5                           3.6
                                2000                             64.5                          37.5                           3.6
                                2450                             51.5                          30.4                           3.6
                                3000                             41.5                          25.0                           3.6
                             5200 - 5800                         20.6                          40.65                          3.6


    4. Validation Phantom

    The validation phantom is the SAM (Specific Anthropomorphic Mannequin) phantom manufactured by
    Schmid & Partner Engineering AG. The SAM phantom is a Fiberglass shell integrated in a wooden table.
    The shape of the shell corresponds to the phantom defined by SCC34-SC2. It enables the dosimetric
    evaluation of left and right hand phone usage as well as body mounted usage at the flat phantom region. A
    cover prevents evaporation of the liquid. Reference markings on the phantom allow the complete setup of all
    predefined phantom positions and measurement grids by manually teaching three points in the robot.

                  Shell Thickness: 2.0 ± 0.1 mm
                  Filling Volume: Approx. 25 liters
                  Dimensions:      50 cm (W) x 100 cm (L)




                                 SAM Phantom                                               Fluid Depth (t 15.0 cm)




2007 Celltech Labs Inc.       This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.     Page 4 of 11


Celltech


Celltech


                                Date of Evaluation:          May 10, 2007                   Document Serial No.:                 SV5800M-051007-R1.2
                                 Evaluation Type:          System Validation          Validation Dipole:         5800 MHz        Fluid Type:     Body


    7. SAR Measurement

    Measurements were made using a dosimetric E-field probe EX3DV4 (S/N: 3600, Conversion Factor 4.14).
    The SAR measurement was performed with the E-field probe in mechanical detection mode only. The setup
    and determination of the forward power into the dipole was performed using the procedures described
    below.
    First the power meter PM1 (including attenuator Att1) is connected to the cable to measure the forward
    power at the location of the dipole connector (X). The signal generator is adjusted for the desired forward
    power at the dipole connector (taking into account the attenuation of Att1) as read by power meter PM2.
    After connecting the cable to the dipole, the signal generator is readjusted for the same reading at power
    meter PM2. If the signal generator does not allow adjustment in 0.01dB steps, the remaining difference at
    PM2 must be taken into consideration. PM3 records the reflected power from the dipole to ensure that the
    value is not changed from the previous value. The reflected power should be 20dB below the forward
    power.




                                                                                               3D Probe positioner

                                                  d
                                                                                     Field probe
                                                                                                        Flat Phantom




                                                                                                        Dipole




                                                           Dir.Coupler
          Signal          Amp        Low        3dB                                                 x
          Generator                  Pass                                        Cable                       Att1
                                                Att3
                                                                                                                   PM1

                                                                Att2    PM3



                                                          PM2




                                              System Validation Measurement Setup Diagram




2007 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.     Page 7 of 11


                                 Date of Evaluation:            May 10, 2007                   Document Serial No.:                 SV5800M-051007-R1.2
                                   Evaluation Type:           System Validation          Validation Dipole:        5800 MHz         Fluid Type:      Body



    8. Measurement Conditions

           The SAM phantom was filled with 5800 MHz Body tissue simulant.

           Relative Permittivity:           44.7 (-7.2% deviation from target)
           Conductivity:                    6.22 mho/m (+3.7% deviation from target)
           Fluid Temperature:               23.6 qC (Start of Test) / 23.2 qC (End of Test)
           Fluid Depth:                     t 15.0 cm

           Environmental Conditions:
           Ambient Temperature:              23.1qC
           Humidity:                         31%
           Barometric Pressure:              101.1 kPa

           The 5800 MHz Body tissue simulant consisted of the following ingredients:

                                     Ingredient                                           Percentage by weight
                                         Water                                                      64 - 78%
                                     Mineral Oil                                                    11 - 18%
                                     Emulsifiers                                                     9 - 15%
                                 Additives and Salt                                                   2 - 3%
                       IEEE Target Dielectric Parameters:                     Hr = 48.2 (+/-10%)            V = 6.00 S/m (+/-5%)



    9. System Validation SAR Results

               SAR @ 0.25W Input averaged over 1g (W/kg)                               SAR @ 1W Input averaged over 1g (W/kg)
                 SPEAG Target                 Measured           Deviation               SPEAG Target                 Measured           Deviation
                18.5          +/- 10%             19.1              +3.3%              74.1           +/- 10%             76.4             +3.1%
              SAR @ 0.25W Input averaged over 10g (W/kg)                              SAR @ 1W Input averaged over 10g (W/kg)
                 SPEAG Target                 Measured           Deviation               SPEAG Target                 Measured           Deviation
                5.13          +/- 10%             5.36              +4.5%             20.52           +/- 10%            21.44             +4.5%
           Extrapolated Peak SAR               SPEAG Target              81.2        +/- 15%        Measured              87.3             +7.5%




2007 Celltech Labs Inc.      This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.      Page 8 of 11


                              Date of Evaluation:            May 10, 2007                   Document Serial No.:                 SV5800M-051007-R1.2
                                Evaluation Type:           System Validation          Validation Dipole:        5800 MHz         Fluid Type:     Body



    System Validation - 5800 MHz Dipole - May 10, 2007

    DUT: Dipole 5GHz; Type: D5GHzV2; Serial: 1031; Asset: 00126

    Ambient Temp: 23.1ºC; Fluid Temp: 23.6ºC; Barometric Pressure: 101.1 kPa; Humidity: 31%

    Communication System: CW
    Forward Conducted Power: 250 mW
    Frequency: 5800 MHz; Duty Cycle: 1:1
                                                                                                      3
    Medium: M5200-5800 Medium parameters used: f = 5800 MHz; ı = 6.22 mho/m; İr = 44.7; ȡ = 1000 kg/m

    - Probe: EX3DV4 - SN3600; ConvF(4.14, 4.14, 4.14); Calibrated: 24/01/2007
    - Sensor-Surface: 2mm (Mechanical Surface Detection)
    - Electronics: DAE4 Sn353; Calibrated: 21/06/2006
    - Phantom: SAM 4.0; Type: Fiberglas; Serial: 1033
    - Measurement SW: DASY4, V4.7 Build 44; Postprocessing SW: SEMCAD, V1.8 Build 171

    5800 MHz System Validation/Area Scan (9x13x1):
    Measurement grid: dx=5mm, dy=5mm
    Maximum value of SAR (measured) = 40.6 mW/g

    5800 MHz System Validation/Zoom Scan (7x7x9)/Cube 0:
    Measurement grid: dx=4mm, dy=4mm, dz=2.5mm
    Reference Value = 83.1 V/m; Power Drift = 0.174 dB
    Peak SAR (extrapolated) = 87.3 W/kg
    SAR(1 g) = 19.1 mW/g; SAR(10 g) = 5.36 mW/g
    Maximum value of SAR (measured) = 40.2 mW/g




2007 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.     Page 9 of 11


                              Date of Evaluation:            May 10, 2007                   Document Serial No.:                 SV5800M-051007-R1.2
                                Evaluation Type:           System Validation          Validation Dipole:        5800 MHz         Fluid Type:     Body




    10. Measured Fluid Dielectric Parameters
           System Validation - 5800 MHz (Body)
           ************************************************************
           Celltech Labs Inc.
           Test Result for UIM Dielectric Parameter
           Mon 10/May/2007
           Frequency (GHz)
           FCC_eH FCC Bulletin 65 Supplement C (June 2001) Limits for Head Epsilon
           FCC_sH FCC Bulletin 65 Supplement C (June 2001) Limits for Head Sigma
           FCC_eB FCC Limits for Body Epsilon
           FCC_sB FCC Limits for Body Sigma
           Test_e Epsilon of UIM
           Test_s Sigma of UIM
           ************************************************************
           Freq                 FCC_eB FCC_sB Test_e Test_s
           5.7000               48.34 5.88          44.57 6.11
           5.7100               48.32 5.89          44.13 6.03
           5.7200               48.31 5.91          43.79 6.06
           5.7300               48.30 5.92          43.57 6.11
           5.7400               48.28 5.93          43.53 6.26
           5.7500               48.27 5.94          43.52 6.33
           5.7600               48.25 5.95          43.73 6.49
           5.7700               48.24 5.96          44.19 6.52
           5.7800               48.23 5.98          44.57 6.48
           5.7900               48.21 5.99          44.66 6.37
           5.8000               48.20 6.00          44.67 6.22
           5.8100               48.19 6.01          44.53 6.14
           5.8200               48.17 6.02          44.13 6.07
           5.8300               48.16 6.04          43.75 6.09
           5.8400               48.15 6.05          43.46 6.20
           5.8500               48.13 6.06          43.36 6.33
           5.8600               48.12 6.07          43.32 6.51
           5.8700               48.10 6.08          43.57 6.64
           5.8800               48.09 6.09          43.99 6.65
           5.8900               48.08 6.11          44.33 6.63
           5.9000               48.06 6.12          44.43 6.55

2007 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 10 of 11


                                  Date of Evaluation:            May 10, 2007                   Document Serial No.:                 SV5800M-051007-R1.2
                                    Evaluation Type:           System Validation          Validation Dipole:        5800 MHz         Fluid Type:          Body



    11. Measurement Uncertainties

                                        UNCERTAINTY BUDGET FOR SYSTEM VALIDATION
                                                Uncertainty                                                                  Uncertainty
                                                                    Probability                                    ci
                Error Description                 Value                                       Divisor                          Value            Vi or Veff
                                                                    Distribution                                   1g
                                                   ±%                                                                         ±% (1g)

         Measurement System
         Probe calibration (5800 MHz)                6.55               Normal                    1                 1             6.55               f
         Axial isotropy of the probe                  4.7            Rectangular           1.732050808              1             2.7                f
         Spherical isotropy of the probe              9.6            Rectangular           1.732050808              1             5.5                f
         Spatial resolution                            0             Rectangular           1.732050808              1             0.0                f
         Boundary effects                             0.1            Rectangular           1.732050808              1             0.1                f
         Probe linearity                              4.7            Rectangular           1.732050808              1             2.7                f
         Detection limit                               1             Rectangular           1.732050808              1             0.6                f
         Readout electronics                          0.3               Normal                    1                 1             0.3                f
         Response time                                 0             Rectangular           1.732050808              1             0.0                f
         Integration time                              0             Rectangular           1.732050808              1             0.0                f
         RF ambient conditions                         3             Rectangular           1.732050808              1             1.7                f
         Mech. constraints of robot                   0.8            Rectangular           1.732050808              1             0.5                f
         Probe positioning                            5.7            Rectangular           1.732050808              1             3.3                f
         Extrapolation & integration                   4             Rectangular           1.732050808              1             2.3                f
         Dipole
         Dipole positioning                            2             Rectangular           1.732050808              1             1.2                f
         Power & Power Drift                          4.7            Rectangular           1.732050808              1             2.7                f

         Phantom and Setup
         Phantom uncertainty                           4             Rectangular           1.732050808              1             2.3                f
         Liquid conductivity (target)                  5             Rectangular           1.732050808            0.64            1.8                f
         Liquid conductivity (measured)               3.7               Normal                    1               0.64            2.4                f
         Liquid permittivity (target)                 10             Rectangular           1.732050808             0.6            3.5                f
         Liquid permittivity (measured)               7.2               Normal                    1                0.6            4.3                f
         Combined Standard Uncertainty                                                                                           12.72
         Expanded Uncertainty (k=2)                                                                                              25.45
            Measurement Uncertainty Table in accordance with IEEE Standard 1528-2003 and IEC Standard 62209-1:2005


    12. Test Equipment List

                     TEST EQUIPMENT                             ASSET NO.            SERIAL NO.            DATE OF CAL.             CAL. DUE DATE
            SPEAG DASY4 Measurement Server                          00158                  1078                    N/A                       N/A
                           SPEAG Robot                              00046              599396-01                   N/A                       N/A
                           SPEAG DAE4                               00019                  353                  21Jun06                   21Jun07
                SPEAG EX3DV4 E-Field Probe                          00213                  3600                 24Jan07                   24Jan08
                SPEAG 5GHz Validation Dipole                        00126                  1031                10May07                    10May08
                  SPEAG SAM Phantom V4.0C                           00154                  1033                    N/A                       N/A
               ALS-PR-DIEL Dielectric Probe Kit                     00160              260-00953                   N/A                       N/A
                Gigatronics 8652A Power Meter                       00007               1835272                 26Mar07                   26Mar08
              Gigatronics 80701A Power Sensor                       00014               1833699                 22Jan07                   22Jan08
              Gigatronics 80701A Power Sensor                       00109               1834366                 26Mar07                   26Mar08
                 HP 8753ET Network Analyzer                         00134             US39170292                20Apr07                   20Apr08
            Nextec NB00383 Microwave Amplifier                      00151                  0535                   NCR                       NCR
         Rohde & Schwarz SMR20 Signal Generator                     00006                100104                   NCR                       NCR



2007 Celltech Labs Inc.       This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.           Page 11 of 11