MPE Estimates 1

FCC ID: KBCIX-4965AGN

RF Exposure Info

Download: PDF
FCCID_795512

 Applicant: General Dynamics Itronix Corporation                            FCC ID’s: KBCIX-MC5725, KBCIX-4965AGN


Compliance with 47 CFR 15.247(i)



                “Systems operating under the provisions of this section shall be operated in a manner that
                ensures that the public is not exposed to radio frequency energy levels in excess of the
                Commission's guidelines. See § 1.1307(b)(1) of this chapter.”

The EUT will only be used with a separation distance of 20 centimeters or greater between the antenna and the body of the
user or nearby persons and can therefore be considered a mobile transmitter per 47 CFR 2.1091 (b). Calculations are
provided for each radio transmitting through its own internal antenna and optional external antenna.

The total transmit power is less than 1.5 W (ERP), therefore the EUT is categorically excluded from routine environmental
evaluation per 47 CFR 2.1091(c).

The MPE estimates are as follows:

Table 1 in 47 CFR 1.1310 defines the maximum permissible exposure (MPE) for the general population. The exposure level
at a 20 cm distance from the EUT’s transmitting antenna is calculated using the general equation:

                S = (PG)/4πR2
                Where: S = power density (mW/cm2)
                P = power input to the antenna (mW)
                G = numeric power gain relative to an isotropic radiator
                R = distance to the center of the radiation of the antenna (20 cm = limit for MPE estimates)
                PG = EIRP

Solving for S, the maximum power densities 20 cm from the transmitting antennas are summarized in the tables on the
following pages:




                                                                                                                            1


 Applicant: General Dynamics Itronix Corporation                             FCC ID’s: KBCIX-MC5725, KBCIX-4965AGN


MPE Estimates for Self Located Device



FCC ID: KBCIX-MC5725

CDMA

                                                                                                                            Ratio of
                                                                                                             General
                                                               Max Peak              Minimum                                Power
                                                                                                   Power    Population
                                              Transmit         Conducted   Antenna   Antenna                                Density
   Antenna Type         Antenna Part No.                                                          Density   Exposure
                                             Frequency          Output      Gain      Cable                                  to the
                                                                                                  @ 20 cm   Limit from
                                                                 Power                 Loss                                Exposure
                                                                                                              1.1310
                                                                                                                              Limit
IX605 Primary WAN                               (MHz)            (mW)       (dBi)       (dB)     (mW/cm2)   (mW/cm2)
  Meander Line          Skycross 2-2920    1851.25 - 1908.75     304.8       1.8        1.1        0.076         1          0.076
  Meander Line          Skycross 2-2920     824.7 – 848.31       325.8       3.4        0.7        0.121       0.55         0.121
External MaxRad        BMLPVDB800/1900     1851.25 - 1908.75     304.8        3         3.7        0.055        1           0.055
External MaxRad        BMLPVDB800/1900      824.7 – 848.31       325.8        3         2.2        0.078       0.55         0.078

Worst Case Ratio of Power Density to the Exposure Limit =0.121     Duty Cycle not taken in to account.




Excerpts from TCB Training, April 3, 2002, “Mobile Transmitters”, Slide 6:

        “Devices operating in multiple frequency bands

            ‰     When RF exposure evaluation is required for TCB approval
                     o Separate antennas – estimated minimum separation distances may be considered for the
                        frequency bands that do not require evaluation or TCB approval, however, the estimated distance
                        should take into account the effect of co-located transmitters. (Note 24)

                         Note 24 According to multiple frequency exposure criteria, the ratio of field strength or power
                         density to the applicable exposure limit at the exposure location should be determined for each
                         transmitter and the sum of these ratios must not exceed 1.0 for the location to be compliant.”


The sum of the ratio(s) (power density to the exposure limit) does not exceed 1.0; therefore, the exposure condition is
compliant with FCC rules.




                                                                                                                             2


 Applicant: General Dynamics Itronix Corporation                              FCC ID’s: KBCIX-MC5725, KBCIX-4965AGN


MPE Estimates for Self Located Device

FCC ID: KBCIX-4965AGN

WLAN, IEEE 802.11 (a) (b) (g) & (n)

                                                                                                                            Ratio of
                                                                                                           General
                                              Max Peak                      Minimum         Power                           Power
                  Antenna Part    Transmit                    Antenna                                     Population
 Antenna Type                                 Conducted                     Antenna        Density @                     Density to the
                      No.        Frequency                     Gain                                     Exposure Limit
                                             Output Power                  Cable Loss        20 cm                         Exposure
                                                                                                         from 1.1310
                                                                                                                             Limit
                                                                                                    2             2
                                     (MHz)         (mW)         (dBi)         (dB)         (mW/cm )       (mW/cm )
Part 15C
Inverted F MAIN   EST07-10       5745-5825         303          -2.0          2.0           0.024             1           0.024
Inverted F MAIN   EST07-10       2412-2462         463          -3.5          0.9           0.033             1           0.033
External MaxRad   MAXC24503      2412-2462         463           3            4.4           0.067             1           0.067
External MaxRad   BMAXC24505     2412-2462         463           5            4.4           0.106             1           0.106
Part 15 E
Inverted F MAIN   EST07-10       5180-5240         50           -2.0          2.0           0.004             1           0.004
Inverted F MAIN   EST07-10       5260-5320         123          -2.0          2.0           0.010             1           0.010

 Worst Case Ratio of Power Density to the Exposure Limit = 0.106




 Worst Case Co-located Exposure Condition
 FCC ID: KBCIX-MC5725
 FCC ID: KBCIX-4965AGN
 Per Note 24 shown below, the Sum of Worst Case Power Ratios cannot exceed 1.0


                     802.11abgn                           Sum of Worst
 CDMA Radio
                   Radio Worst                             Case Ratios
  Worst Case                                                                  FCC Limit for
                    Case Ratio of                            (Power
 Ratio of Power                                                               Sum of Worst
                    Power Density                         Density to the
 Density to the                                                                Case Ratios
                   to the Exposure                          Exposure
 Exposure Limit
                         Limit                                Limit)

      0.121             0.106                                 0.227                  1.0                 PASS


 The results shown in the above table are equivalent to the Sum of the EIRP of the Two Co-located Transmitters (EIRP TX1
 + EIRP TX2) compared to the exposure limit. The benefit of this method, is that accounts for transmitters operating at
 different frequencies against different exposure limits.




                                                                                                                                    3



Document Created: 2007-05-22 08:20:23