SAR Test Report

FCC ID: KBCFEX21RIM802

RF Exposure Info

Download: PDF
FCCID_122371

CELLTECH RESEARCH INC.                                                    Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________



                            CERTIFICATE OF COMPLIANCE
                                 SAR EVALUATION

 Test Lab:                                           Applicant Name:

 CELLTECH RESEARCH INC.                              ITRONIX CORPORATION
 Testing and Engineering Lab                         801 South Stevens Street
 1955 Moss Court                                     Spokane, WA 99204
 Kelowna, B.C.                                       Attn: Fred Phillips, Certification Engineer
 Canada V1Y 9L3                                      Phone: 509-742-1506
 Phone:     250 - 860-3130                           Fax:      509-626-4204
 Fax:       250 - 860-3110
 Toll Free: 1-877-545-6287
 e-mail:    celltech@globuswireless.com
 web site: www.globuswireless.com

      FCC ID:               KBCFEX21RIM802
      Model(s):             FeX21
      Equipment Type:       Rugged Handheld PC w/ RIM 802 DataTAC Radio Modem
      Tx Frequency Range: 806-825 MHz
      Rx Frequency Range: 851-870 MHz
      Max. RF Output Power: 1.3 Watts
      FCC Rule Part(s):     2.1093; ET Docket 96.326

This wireless mobile and/or portable device has been shown to be compliant for localized specific
absorption rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE
Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in
ANSI/IEEE Std. C95.3-1999. (See test report).

I attest to the accuracy of data. All measurements were performed by me or were made under my
supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the
completeness of these measurements and vouch for the qualifications of all persons taking them.

Celltech Research Inc. certifies that no party to this application has been denied FCC benefits pursuant to
Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a).




Shawn McMillen
General Manager
Celltech Research Inc.



© 2000 Celltech Research Inc.


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________




                                  TABLE OF CONTENTS


    1.0        INTRODUCTION…………………………………………………………                                                 1

    2.0        DESCRIPTION OF EUT………..………………………..………………                                           1

    3.0        SAR MEASUREMENT SYSTEM ………………………………………                                             2

    4.0        MEASUREMENT SUMMARY……..…………………………………...                                            3

    5.0        SAR LIMITS………………………………………………………………                                                 3

    6.0        DETAILS OF SAR EVALUATION…………………………………….                                           4

    7.0        EVALUATION PROCEDURES……..…………………………………..                                           5

    8.0        SYSTEM VALIDATION………………………………………………....                                            5

    9.0        SIMULATED EQUIVALENT TISSUES………….…………………….                                         6

    10.0       TISSUE PARAMETERS…………………………………………………                                               6

    11.0       SYSTEM SPECIFICATIONS.…………………………………………...                                          7

    12.0       TEST EQUIPMENT LIST………………………………………..………                                            8

    13.0       MEASUREMENT UNCERTAINTIES………………………………….                                            9

    14.0       REFERENCES……………………………………………………………. 10

    APPENDIX A - SAR MEASUREMENT DATA…………...…………………….                                             11
    APPENDIX B - DIPOLE VALIDATION………………………………………...                                              12
    APPENDIX C - PROBE CALIBRATION………………………………………..                                               13
    APPENDIX D - TEST SETUP PHOTOGRAPHS……………………………….                                              14




© 2000 Celltech Research Inc.


CELLTECH RESEARCH INC.                                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


1.0 INTRODUCTION

This measurement report is designed to show compliance of the Itronix Model: FeX21 Rugged
Handheld PC with RIM 802-2-0 DataTAC Radio Modem FCC ID: KBCFEX21RIM802 with
FCC Part 2, 1093, ET Docket 96-326 Rules for mobile and portable devices. The test
procedures, as described in American National Standards Institute C95.1 - 1992 (1), FCC OET
Bulletin 65–1997 were employed. A description of the product and operating configuration,
detailed summary of the test results, methodology and procedures used in the evaluation,
equipment used, and the various provisions of the rules are included within this test report.


2.0 DESCRIPTION of Equipment Under Test (EUT)

                             Rugged Handheld PC
                                                                                   Licensed Non-Broadcast
        EUT Type            with RIM 802 DataTAC          Equipment Class
                                                                                   Station Transmitter (TNB)
                                 Radio Modem
                                  RIM 802D-2-O
       Radio Type                                              Model No.(s)                 FeX21
                                (DataTAC Network)

         FCC ID                 KBCFEX21RIM802                   S/N No.                Pre-production


     Tx Frequency                                                Max. RF
                                     806-825                                              1.3 Watts
     Range (MHz)                                               Output Power

     Rx Frequency                                                Signal
                                     851-870                                                 FSK
     Range (MHz)                                               Modulation(s)

     Antenna Type                     Dipole               Antenna Length                  160 mm




     Figure 1. Front of EUT            Figure 2. Rear of EUT        Figure 3. Antenna    Figure 4. Radio Modem



© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                      1
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                  Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


3.0 SAR MEASUREMENT SYSTEM

Celltech Research SAR measurement facility utilizes the Dosimetric Assessment System
(DASY™) manufactured by Schmid & Partner Engineering AG (SPEAG™) of Zurich,
Switzerland. The DASY system is comprised of the robot controller, computer, near-field probe,
probe alignment sensor, and the generic twin phantom containing brain or muscle equivalent
material (see Figure 6). The robot is a six-axis industrial robot performing precise movements to
position the probe to the location (points) of maximum electromagnetic field (EMF). A cell
controller system contains the power supply, robot controller, teach pendant (Joystick), and remote
control, is used to drive the robot motors. The Staubli robot is connected to the cell controller to
allow software manipulation of the robot. A data acquisition electronics (DAE) circuit performs
the signal amplification, signal multiplexing, AD-conversion, offset measurements, mechanical
surface detection, collision detection, etc. is connected to the Electro-optical coupler (EOC). The
EOC performs the conversion from the optical into digital electric signal of the DAE and transfers
data to the PC plug-in card. The DAE3 utilizes a highly sensitive electrometer-grade preamplifier
with auto-zeroing, a channel and gain-switching multiplexer, a fast 16 bit AD-converter and a
command decoder and control logic unit. Transmission to the PC-card is accomplished through an
optical downlink for data and status information and an optical uplink for commands and clock
lines. The mechanical probe-mounting device includes two different sensor systems for frontal and
sidewise probe contacts. They are also used for mechanical surface detection and probe collision
detection. The robot uses its own controller with a built in VME-bus computer.




                                     Figure 5. DASY3 SAR Measurement System



© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                               2
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


4.0 MEASUREMENT SUMMARY

The measurement results were obtained with the EUT tested in the conditions described in this
report. Detailed measurement data and plots showing the maximum SAR location of the EUT
are reported in Appendix A.

                                Conducted   Antenna Phantom Separation                    SAR
    Freq.       Mode
                                 Power      Position Position Distance                   (w/kg)
   (MHz)        Tested
                                 (dBm)                         (cm)

     806       Unmod.             33.0      Vertical     Flat        4.0        1.02            0.255
                                                                                          (25% duty cycle)


     815       Unmod.             33.0      Vertical                            1.13            0.2825
                                                         Flat        4.0                  (25% duty cycle)


     821       Unmod.             33.0      Vertical     Flat        4.0        1.54            0.385
                                                                                          (25% duty cycle)

         Mixture Type: Muscle                       ANSI / IEEE C95.1 1992 - SAFETY LIMIT
        Dielectric Constant: 56.1             Spatial Peak Uncontrolled Exposure/General Population
           Conductivity: 0.95                      Body SAR: 1.6 W/kg (averaged over 1 gram)


Notes:
   1. All modes of operation were investigated and the worst-case SAR levels are recorded.
   2. The SAR values found were below the maximum limit of 1.6 w/kg.
   3. The worst-case SAR value found was 0.385 w/kg (25% duty cycle).


5.0 SAR SAFETY LIMITS


                           EXPOSURE LIMITS                                             SAR
           (General populations/Uncontrolled Exposure Environment)                     (W/Kg)

           Spatial Average (averaged over the whole body)                               0.08

             Spatial Peak (averaged over any 1g of tissue)                              1.60

      Spatial Peak (hands/wrists/feet/ankles averaged over 10g)                         4.00


Notes: 1. The FCC SAR safety limits specified in the table above apply to devices operated
          in the General Population / Uncontrolled Exposure environment.
       2. Uncontrolled environments are defined as locations where there is exposure of
          individuals who have no knowledge or control of their exposure.

© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                3
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                     Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


6.0 DETAILS OF SAR EVALUATION

The Itronix FeX21 Rugged Handheld PC with RIM 802 DataTAC Radio Modem FCC ID:
KBCFEX21RIM802 was found to be compliant for localized specific absorption rate (SAR)
based on the following test provisions and conditions:

1) The EUT is operated in a body-worn configuration. For the test setup the rear of the device
   (antenna side) was placed facing up and parallel to the outer surface of the planar phantom
   with 4.0cm spacing between the antenna and the outer surface of the planar phantom.
2) The body-worn measurements were evaluated at maximum power and the unit was operated
   for an appropriate period prior to the evaluation in order to minimize drift.
3) The device was keyed to operate continuously in the transmit mode for the duration of the
   test.
4) The location of the maximum spatial SAR distribution (Hot Spot) was determined relative to
   the device and its antenna.
5) The EUT was tested with a fully charged battery.




           Figure 5. Test Setup with 4cm spacing between device antenna and planar phantom surface.




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                               4
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


7.0 EVALUATION PROCEDURES

The Specific Absorption Rate (SAR) evaluation was performed in the following manner:

a. (i) The evaluation was performed in an applicable area of the phantom depending on the type
of device being tested. For devices worn about the ear during normal operation, both the left and
right ear positions were evaluated at the center frequency of the band at maximum power. The
side, which produced the greatest SAR, determined which side of the phantom would be used for
the entire evaluation. The positioning of the head worn device relative to the phantom was
dictated by FCC OET bulletin 65 Supp., C.
    (ii) For body worn devices or devices which can be operated within 20 cm of the body, the
planar section of the phantom was used. The type of device being evaluated dictated the distance
of the EUT to the outer surface of the planar phantom.

b. The SAR was determined by a pre-defined procedure within the DASY3 software. Upon
completion of a reference and optical surface check, the exposed region of the phantom was
scanned near the inner surface with a grid spacing of 20mm x 20mm.

c. A 5x5x7 matrix was performed around the greatest spatial SAR distribution found during the
area scan of the applicable exposed region. SAR values were then calculated using a 3-D spline
interpolation algorithm and averaged over spatial volumes of 1 and 10 grams.

d. If the EUT had any appreciable drift over the course of the evaluation, then the EUT was re-
evaluated. Any unusual anomalies over the course of the test also warranted a re-evaluation.


8.0 SYSTEM VALIDATION

Prior to the assessment, the system was verified in the planar region of the phantom. For devices
operating below 1GHz, an 835MHz dipole or 900MHz was used, depending on the operating
frequency of the EUT. For devices operating above 1GHz, an 1800MHz dipole was used. A
forward power of 250mW was applied to the dipole and system was verified to a tolerance of
+5%. Following the validation, the fluid remained or was changed depending on the particular
part of the body being evaluated. The applicable verification(s) is/are as follows (see Appendix
B for validation test plot):


      Dipole Validation Kit              Target SAR 1g (w/kg)        Measured SAR 1g (w/kg)


               D835V2                             2.06                            2.04




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                               5
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


9.0 SIMULATED TISSUES

The brain and muscle mixtures consist of a viscous gel using hydroxethylcellullose (HEC)
gelling agent and saline solution. Preservation with a bactericide was added and visual
inspection was made to ensure air bubbles are not trapped during the mixing process. The
mixture was calibrated to obtain proper dielectric constant (permittivity) and conductivity of
the tissue.



                       INGREDIENT                          FREQUENCY
                                                         (835MHz Muscle)

                                Water                          52.4%

                                Sugar                          45.0%

                                Salt                            1.4%

                                HEC                             1.0%

                          Bactericide                           0.2%




10.0 TISSUE PARAMETERS

The dielectric parameters of the fluids were verified prior to the SAR evaluation using an
85070C Dielectric Probe Kit and an 8753E Network Analyzer. The dielectric parameters of the
fluid are as follows:


           Frequency               Dielectric Constant     Conductivity
                                                                                      ñ (Kg/m3)
            (Muscle)                        år              ó (mho/m)

          800-850 MHz                   56.1 ± 5%           0.95 ± 10%                   1000




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                               6
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                  Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


11.0 ROBOT SYSTEM SPECIFICATIONS

Specifications
       POSITIONER:                   Stäubli Unimation Corp. Robot Model: RX60L
       Repeatability:                0.02 mm
       No. of axis:                  6

Data Acquisition Electronic (DAE) System
      Cell Controller
      Processor:            Pentium III
      Clock Speed:          450 MHz
      Operating System: Windows NT
      Data Card:            DASY3 PC-Board
      Data Converter
      Features:             Signal Amplifier, multiplexer, A/D converter, and control logic
      Software:             DASY3 software
      Connecting Lines: Optical downlink for data and status info.
                            Optical uplink for commands and clock

PC Interface Card
      Function:                      24 bit (64 MHz) DSP for real time processing
                                     Link to DAE3
                                     16 bit A/D converter for surface detection system
                                     serial link to robot
                                     direct emergency stop output for robot

E-Field Probe
       Model:                        ET3DV6
       Serial No.:                   1387
       Construction:                 Triangular core fiber optic detection system
       Frequency:                    10 MHz to 6 GHz
       Linearity:                    ± 0.2 dB (30 MHz to 3 GHz)

Phantom
      Phantom:                       Generic Twin
      Shell Material:                Fiberglass
      Thickness:                     2.0 ± 0.1 mm




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                               7
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


12.0 TEST EQUIPMENT LIST


                                   SAR MEASUREMENT SYSTEM

                      EQUIPMENT                              S/N #          CALIBRATION DATE


                   DASY3 System
                       -Robot                             599396-01                   N/A
                -ET3DV6 E-Field Probe                       1387                    Sept 1999
                        -DAE                                 383                    Sept 1999
              -835MHz Validation Dipole                      411                    Aug 1999
              -900MHz Validation Dipole                      054                    Aug 1999
             -1800MHz Validation Dipole                      247                    Aug 1999
             -Generic Twin Phantom V3.0                     N/A                       N/A


            85070C Dielectric Probe Kit                       N/A                      N/A


          Gigatronics 8652A Power Meter                    1835272                   Oct 1999
               -Power Sensor 80701A                        1833535                   Oct 1999
               -Power Sensor 80701A                        1833542                   Oct 1999


             E4408B Spectrum Analyzer                    US39240170                 Nov 1999


              8594E Spectrum Analyzer                    3543A02721                  Mar 2000


              8753E Network Analyzer                     US38433013                 Nov 1999


               8648D Signal Generator                    3847A00611                    N/A


  5S1G4 Amplifier Research Power Amplifier                   26235                     N/A




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                               8
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


13.0 MEASUREMENT UNCERTAINTIES



    Uncertainty Description                Error    Distribution     Weight       Standard        Offset
                                                                                  Deviation
Probe Uncertainty
Axial isotropy                            ±0.2 dB     U-Shaped          0.5         ±2.4 %
Spherical isotropy                        ±0.4 dB     U-Shaped          0.5         ±4.8 %
Isotropy from gradient                    ±0.5 dB     U-Shaped           0             ±
Spatial resolution                         ±0.5 %      Normal            1          ±0.5 %
Linearity error                           ±0.2 dB     Rectangle          1          ±2.7 %
Calibration error                          ±3.3 %      Normal            1          ±3.3 %
SAR Evaluation Uncertainty
Data acquisition error                     ±1 %       Rectangle          1          ±0.6 %
ELF and RF disturbances                   ±0.25 %      Normal            1          ±0.25 %
Conductivity assessment                    ±10 %      Rectangle          1          ±5.8 %
Spatial Peak SAR Evaluation
Uncertainty
Extrapolated boundary effect               ±3 %        Normal            1           ±3 %         ±5 %
Probe positioning error                   ±0.1 mm      Normal            1           ±1 %
Integrated and cube orientation            ±3 %        Normal            1           ±3 %
Cube Shape inaccuracies                    ±2 %       Rectangle          1          ±1.2 %
Device positioning                         ±6 %        Normal            1           ±6 %
Combined Uncertainties                                                              ±11.7 %       ±5 %



Measurement uncertainties in SAR measurements are difficult to quantify due to several
variables including biological, physiological, and environmental. However, the estimated
measurement uncertainties in SAR are less than 15-25 %.

According to ANSI/IEEE C95.3, the overall uncertainties are difficult to assess and will vary
with the type of meter and usage situation. However, accuracy’s of ± 1 to 3 dB can be expected
in practice, with greater uncertainties in near-field situations and at higher frequencies (shorter
wavelengths), or areas where large reflecting objects are present. Under optimum measurement
conditions, SAR measurement uncertainties of at least ± 2dB can be expected.

According to CENELEC, typical worst-case uncertainty of field measurements is ± 5 dB.
For well-defined modulation characteristics the uncertainty can be reduced to ± 3 dB.




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                9
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


14.0 REFERENCES

(1) ANSI, ANSI/IEEE C95.1: IEEE Standard for Safety Levels with Respect to Human Exposure
to Radio Frequency Electromagnetic Fields, 3kHz to 300 Ghz, The Institute of Electrical and
Electronics Engineers, Inc., New York, NY 10017, 1992;

(2) Federal Communications Commission, “Evaluating Compliance with FCC Guidelines for
Human Exposure to Radio frequency Electromagnetic Fields”, OET Bulletin 65, FCC,
Washington, D.C. 20554, 1997;

(3) Thomas Schmid, Oliver Egger, and Neils Kuster, “Automated E-field scanning system for
dosimetric assessments”, IEEE Transaction on Microwave Theory and Techniques, Vol. 44, pp.
105 – 113, January, 1996.

(4) Niels Kuster, Ralph Kastle, and Thomas Schmid, “Dosimetric evaluation of mobile
communications equipment with know precision”, IEICE Transactions of Communications, vol.
E80-B, no. 5, pp. 645 – 652, May 1997.




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                              10
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


APPENDIX “A” - SAR MEASUREMENT DATA




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                              11
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


Celltech Research Inc.




                            ITRONIX FCC ID: KBCFEX21RIM802
                              Generic Twin Phantom; Flat Section; Position: (270°,90°);
                         Probe: ET3DV6 - SN1387; ConvF(6.43,6.43,6.43); Crest factor: 1.0;
                             Muscle 835 MHz: σ = 0.95 mho/m εr = 56.1 ρ = 1.00 g/cm3
                                      Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0
                                                   Cube 5x5x7
                          SAR (1g): 1.02 mW/g * , SAR (10g): 0.714 mW/g * Max outside

                                            Separation Distance 4.0cm
                                              Unmodulated Carrier
                                             Low Channel [806MHz]
                                            Conducted Power 33dBm
                                             Date Tested: Oct 2, 2000




                                                                                             SARTot [mW/g]


                                                                                                   1.04E+0

                                                                                                   7.27E-1

                                                                                                   4.16E-1

                                                                                                   1.04E-1




Celltech Research Inc.


Celltech Research Inc.




                            ITRONIX FCC ID: KBCFEX21RIM802
                              Generic Twin Phantom; Flat Section; Position: (270°,90°);
                         Probe: ET3DV6 - SN1387; ConvF(6.43,6.43,6.43); Crest factor: 1.0;
                             Muscle 835 MHz: σ = 0.95 mho/m εr = 56.1 ρ = 1.00 g/cm3
                                      Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0
                                                   Cube 5x5x7
                                  SAR (1g): 1.13 mW/g, SAR (10g): 0.761 mW/g

                                            Separation Distance 4.0cm
                                              Unmodulated Carrier
                                             Mid Channel [815MHz]
                                            Conducted Power 33dBm
                                             Date Tested: Oct 2, 2000




                                                                                             SARTot [mW/g]


                                                                                                   1.02E+0

                                                                                                   7.12E-1

                                                                                                   4.07E-1

                                                                                                   1.02E-1




Celltech Research Inc.


Celltech Research Inc.




                            ITRONIX FCC ID: KBCFEX21RIM802
                              Generic Twin Phantom; Flat Section; Position: (270°,90°);
                         Probe: ET3DV6 - SN1387; ConvF(6.43,6.43,6.43); Crest factor: 1.0;
                             Muscle 835 MHz: σ = 0.95 mho/m εr = 56.1 ρ = 1.00 g/cm3
                                      Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0
                                                   Cube 5x5x7
                                  SAR (1g): 1.54 mW/g, SAR (10g): 1.05 mW/g

                                            Separation Distance 4.0cm
                                              Unmodulated Carrier
                                             High Channel [821MHz]
                                            Conducted Power 33dBm
                                             Date Tested: Oct 2, 2000




                                                                                             SARTot [mW/g]


                                                                                                   1.32E+0

                                                                                                   9.25E-1

                                                                                                   5.29E-1

                                                                                                   1.32E-1




Celltech Research Inc.


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


APPENDIX “B” – DIPOLE VALIDATION




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                              12
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


Celltech Research Inc.




                                             Dipole 835 MHz
                               Generic Twin Phantom; Flat Section; Position: (90°,90°);
                         Probe: ET3DV6 - SN1387; ConvF(6.43,6.43,6.43); Crest factor: 1.0;
                              Brain 835 MHz: σ = 0.80 mho/m εr = 44.2 ρ = 1.00 g/cm3
                                      Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0
                                                   Cube 5x5x7
                                  SAR (1g): 2.04 mW/g, SAR (10g): 1.34 mW/g

                                          Validation Date: Oct. 2, 2000




                                                                                             SARTot [mW/g]




                                                                                                   1.94E+0

                                                                                                   1.51E+0

                                                                                                   1.08E+0

                                                                                                   6.48E-1

                                                                                                   2.16E-1




Celltech Research Inc.


Validation SN411, 08/26/99




Validation Dipole D835V2 SN:411, d = 15mm
Frequency: 835 MHz; Antenna Input Power: 250 [mW]
Generic Twin Phantom; Flat Section; Grid Spacing: Dx = 20.0, Dy = 20.0, Dz = 10.0
Probe: ET3DV5 - SN1342/DAE3; ConvF(5.75,5.75,5.75); Brain 835 MHz: σ = 0.80 mho/m εr = 44.2 ρ = 1.00 g/cm 3
Cubes (2): Peak: 3.07 mW/g ± 0.05 dB, SAR (1g): 2.06 mW/g ± 0.05 dB, SAR (10g): 1.38 mW/g ± 0.05 dB, (Worst-case extrapolation)
Penetration depth: 13.6 (12.7, 14.8) [mm]
Powerdrift: -0.00 dB




                                                                                                                                  SARTot [mW/g]




                                                                                                                                         2.50E+0

                                                                                                                                         2.25E+0

                                                                                                                                         2.00E+0

                                                                                                                                         1.75E+0

                                                                                                                                         1.50E+0

                                                                                                                                         1.25E+0

                                                                                                                                         1.00E+0

                                                                                                                                         7.50E-1

                                                                                                                                         5.00E-1

                                                                                                                                         2.50E-1




Schmid & Partner Engineering AG, Zurich Switzerland


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


APPENDIX “C” – PROBE CALIBRATION




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                              13
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


Probe ET3DV6
           SN:1387
Manufactured:                September 21, 1999
Last calibration:            September 22, 1999



     Calibrated for System DASY3




                    Page 1 of 7


ET3DV6 SN:1387


DASY3 - Parameters of Probe: ET3DV6 SN:1387
Sensitivity in Free Space                              Diode Compression

                        1.55 µV/(V/m)
                                      2
        NormX                                                      DCP X               98 mV
                        1.65 µV/(V/m)
                                         2
        NormY                                                      DCP Y               98 mV
                        1.64 µV/(V/m)
                                         2
        NormZ                                                      DCP Z               98 mV

Sensitivity in Tissue Simulating Liquid

Brain         450 MHz                 εr = 48 ± 5%           σ = 0.50 ± 10% mho/m


        ConvF X         6.76 extrapolated                          Boundary effect:
        ConvF Y         6.76 extrapolated                          Alpha              0.30
        ConvF Z         6.76 extrapolated                          Depth              2.52

Brain         900 MHz                 εr = 42.5 ± 5%         σ = 0.86 ± 10% mho/m


        ConvF X         6.34 ± 7% (k=2)                            Boundary effect:
        ConvF Y         6.34 ± 7% (k=2)                            Alpha              0.47
        ConvF Z         6.34 ± 7% (k=2)                            Depth              2.25

Brain        1500 MHz                 εr = 41 ± 5%           σ = 1.32 ± 10% mho/m


        ConvF X         5.78 interpolated                          Boundary effect:
        ConvF Y         5.78 interpolated                          Alpha              0.69
        ConvF Z         5.78 interpolated                          Depth              1.88

Brain        1800 MHz                 εr = 41 ± 5%           σ = 1.69 ± 10% mho/m


        ConvF X         5.50 ± 7% (k=2)                            Boundary effect:
        ConvF Y         5.50 ± 7% (k=2)                            Alpha              0.81
        ConvF Z         5.50 ± 7% (k=2)                            Depth              1.70

Sensor Offset

        Probe Tip to Sensor Center                     2.7                    mm
        Optical Surface Detection                      1.6 ± 0.2              mm




                                     Page 2 of 7


ET3DV6 SN:1387



                                        Receiving Pattern (φ), θ = 0°

              f = 30 MHz, TEM cell ifi110                                                          f = 100 MHz, TEM cell ifi110

                                         0                                                                                    0
                                  350         10                                                                       350         10
                            340                     20                                                           340                     20
                      330                                 30                                               330                                 30
                320                                             40                                   320                                             40
          310                                                         50                       310                                                         50
        300                                                                60                300                                                                60

   290                                                                      70          290                                                                      70

  280                                                                           80     280                                                                           80

  270                                                                            90    270                                                                            90

  260                                                                           100    260                                                                           100

   250                                                                      110         250                                                                      110

        240                                                                120               240                                                                120
          230                                                         130                      230                                                         130
                220                                             140                                  220                                             140
                      210                                 150                                              210                                 150
                            200                     160                                                          200                     160
                                  190         170                                                                      190         170
                                        180                                                                                  180


                 X                 Y           Z                     Tot                              X                 Y           Z                     Tot




              f = 300 MHz, TEM cell ifi110                                                         f = 900 MHz, TEM cell ifi110

                                         0                                                                                    0
                                  350         10                                                                       350         10
                            340                     20                                                           340                     20
                      330                                 30                                               330                                 30
                320                                             40                                   320                                             40
          310                                                         50                       310                                                         50

        300                                                                60                300                                                                60

   290                                                                      70          290                                                                      70

  280                                                                            80    280                                                                            80

  270                                                                            90    270                                                                            90

  260                                                                            100   260                                                                            100

   250                                                                      110         250                                                                      110

        240                                                                120               240                                                                120

          230                                                         130                      230                                                         130
                220                                             140                                  220                                             140
                      210                                 150                                              210                                 150
                            200                     160                                                          200                     160
                                  190         170                                                                      190         170
                                        180                                                                                  180


                 X                 Y           Z                     Tot                              X                 Y           Z                     Tot




                                                                      Page 3 of 7


ET3DV6 SN:1387


                           f = 1800 MHz, WG R22                                                                        f = 2500 MHz, WG R26

                                                       0                                                                                      0
                                            350            10                                                                          350          10
                                      340                           20                                                           340                         20
                                330                                       30                                               330                                     30
                          320                                                   40                                   320                                                 40
                    310                                                               50                       310                                                             50

               300                                                                         60                300                                                                    60

              290                                                                           70          290                                                                          70

       280                                                                                       80    280                                                                                80

      270                                                                                        90    270                                                                                90

       260                                                                                       100   260                                                                                100

              250                                                                           110         250                                                                          110

               240                                                                         120               240                                                                    120

                    230                                                               130                      230                                                             130
                          220                                                   140                                  220                                                 140
                                210                                       150                                              210                                     150
                                      200                           160                                                          200                         160
                                            190            170                                                                         190          170
                                                   180                                                                                       180


                           X                 Y                  Z                    Tot                              X                 Y                Z                    Tot




                                                           Isotropy Error (φ), θ = 0°

                1.00
                0.80
                0.60
                0.40                                                                                                                                                          30 MHz
                                                                                                                                                                              100 MHz
  error[dB]




                0.20
                0.00                                                                                                                                                          300 MHz
               -0.20                                                                                                                                                          900 MHz
               -0.40                                                                                                                                                          1800 MHz
               -0.60                                                                                                                                                          2500 MHz
               -0.80
               -1.00
                           0                      60                 120                         180   240                   300                   360




                                                                                      Page 4 of 7


ET3DV6 SN:1387



                                 Frequency Response of E-Field
                                         ( TEM-Cell:ifi110, Waveguide R22, R26 )


                              1.50


                              1.40


                              1.30


                              1.20
         frequency response




                              1.10


                              1.00


                              0.90


                              0.80


                              0.70


                              0.60


                              0.50
                                     0       500     1000         1500   2000   2500   3000
                                                            f [MHz]

                                            TEM               R22               R26




                                                    Page 5 of 7


ET3DV6 SN:1387


                                  Dynamic Range f(SARbrain)
                                            ( TEM-Cell:ifi110 )

                1.E+7


                1.E+6


                1.E+5


                1.E+4
       µV




                1.E+3


                1.E+2


                1.E+1


                1.E+0
                    0.0001         0.001    0.01        0.1       1.        10.      100.
                                                       mW/cm3

                                     not compensated                   compensated




                     1.00



                     0.00
        errror[dB]




                     -1.00



                     -2.00
                         0.0001    0.0010   0.0100      0.1000   1.0000    10.0000 100.0000
                                                       mW/cm3




                                             Page 6 of 7


ET3DV6 SN:1387



                                        Conversion Factor Assessment

                               f = 900 MHz, WG R9                                                    f = 1800 MHz, WG R22

                    0.80                                                                      8.00

                    0.70                                                                      7.00

                    0.60                                                                      6.00
 SAR[mW/cm 3] / W




                                                                           SAR[mW/cm 3] / W
                    0.50                                                                      5.00

                    0.40                                                                      4.00

                    0.30                                                                      3.00

                    0.20                                                                      2.00

                    0.10                                                                      1.00

                    0.00                                                                      0.00
                           0            20            40         60                                  0            20           40        60
                                             z[mm]                                                                     z[mm]

                           Analytical             Measuremets                                        Analytical          Measuremets




                                                   Receiving Pattern (φ)
                                                      ( in brain tissue, z = 5 mm )


                     1.00
                     0.80
                     0.60
                     0.40
      error[dB]




                     0.20
                     0.00
                    -0.20 0                  60            120            180                            240             300           360
                    -0.40
                    -0.60
                    -0.80
                    -1.00
                                                           900 MHz                              1800 MHz




                                                            Page 7 of 7


CELLTECH RESEARCH INC.                                                 Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna,                                           Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
_________________________________________________________________________________________________________


APPENDIX “D” – TEST SETUP PHOTOGRAPHS




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                              14
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                                SAR TEST SETUP PHOTOGRAPHS




© 2000 Celltech Research Inc.    ITRONIX FeX21 FCC ID: KBCFEX21RIM802
                            Rugged Handheld PC with RIM 802 DataTAC Radio Modem



Document Created: 2000-10-20 10:31:02
Document Modified: 2000-10-20 10:31:02

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC