Part 90 Test Report

FCC ID: KBCFEX21RIM802

Test Report

Download: PDF
FCCID_122361

CELLTECH RESEARCH INC.                                                                   Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                                              Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
_______________________________________________________________________________________________________________



                                  CERTIFICATE OF COMPLIANCE
                                   FCC PART 90 CERTIFICATION

      Test Lab:                                                      Applicant Name:

      CELLTECH RESEARCH INC.                                         ITRONIX CORPORATION
      Testing and Engineering Services                               801 South Stevens Street
      1955 Moss Court                                                Spokane, WA 98024
      Kelowna, B.C.                                                  Attn: Fred Phillips, Certification Engineer
      V1Y 9L3 Canada                                                 Phone: 509-742-1506
      Phone:     250 - 860-3130                                      Fax: 509-626-4204
      Fax:       250 - 860-3110
      Toll Free: 1-877-545-6287
      e-mail:    celltech@globuswireless.com
      web site: www.globuswireless.com

      FCC Classification:   Non-Broadcast Station Transmitter (TNB)
      FCC Rule Part(s):     §90, §2
      FCC ID:               KBCFEX21RIM802
      Model(s):             FeX21
      Equipment Type:       Rugged Handheld PC with RIM 802 DataTAC Radio Modem
      Tx Frequency Range: 806 - 825 MHz
      Rx Frequency Range: 851 - 870 MHz
      Max. RF Output Power: 1.3 Watts
      Frequency Tolerance: 2.5 PPM
      Emission Designator: 20K0F1D

  This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in
  the measurement report and was tested in accordance with the measurement procedures specified in §2.947.

  I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my
  supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the
  completeness of these measurements and vouch for the qualifications of all persons taking them.
  Celltech Research Inc. certifies that no party to this application has been denied FCC benefits pursuant to Section 5301 of the
  Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a).




  Shawn McMillen
  General Manager
  Celltech Research Inc .

  © 2000 Celltech Research Inc.


CELLTECH RESEARCH INC.                                                  Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                             Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________



                                   TABLE OF CONTENTS


           1.1 GENERAL INFORMATION                                                         1
           2.1 MEASUREMENT PROCEDURES                                                      2
                    Occupied Bandwidth (2.1049)                                            2
                    Spurious/Harmonic Emissions at Antenna Terminal (2.1051)               3
                    Radiated Spurious & Harmonic Emissions (2.1053)                        3
                    Frequency Stability/Temperature Variation (2.1055)                     3
           3.1 TEST DATA                                                                   4
                    Effective Radiated Power Output                                        4
                    Field Strength of Spurious Radiation                                  5-7
                     Frequency Stability                                                  8-9
           4.1 LIST OF TEST EQUIPMENT                                                     10
           5.1 CONCLUSION                                                                 11


    ATTACHMENT A:                   COVER LETTER(S)
    ATTACHMENT B:                   ATTESTATION STATEMENT(S)
    ATTACHMENT C:                   TEST REPORT
    ATTACHMENT D:                   TEST PLOTS
    ATTACHMENT E:                   FCC ID LABEL & LOCATION
    ATTACHMENT F:                   TEST SETUP PHOTOGRAPHS
    ATTACHMENT G:                   EXTERNAL EUT PHOTOGRAPHS
    ATTACHMENT H:                   INTERNAL EUT PHOTOGRAPHS
    ATTACHMENT I:                   BLOCK DIAGRAM(S)
    ATTACHMENT J:                   CIRCUIT DIAGRAMS / DESCRIPTION
    ATTACHMENT K:                   PARTS LIST / TUNE UP PROCEDURE
    ATTACHMENT L:                   OPERATIONAL DESCRIPTION
    ATTACHMENT M:                   USER’S MANUAL / RF EXPOSURE WARNING
    ATTACHMENT N:                   SAR MEASUREMENT REPORT




© 2000 Celltech Research Inc.


CELLTECH RESEARCH INC.                                                  Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                             Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________


                       MEASUREMENT REPORT - FCC PART 90

   1.1 SCOPE
          Measurement and determination of electromagnetic emissions (EME) from radio
          frequency devices for compliance with the technical rules and regulations of the
          Federal Communications Commission.

   §2.1033(a) General Information


                           APPLICANT:

                           ITRONIX CORPORATION
                           801 South Stevens Street
                           Spokane, WA 98024
                           Attn: Fred Phillips, Certification Engineer
                           Phone: 509-742-1506
                           Fax: 509-626-4204



                     FCC ID                              KBCFEX21RIM802

                     Model(s)                                    FeX21

                    EUT Type                           Rugged Handheld PC
                                                with RIM 802 DataTAC Radio Modem
                  Classification            Licensed Non-Broadcast Station Transmitter (TNB)

                   Rule Part(s)                                §90, §2

          Max. RF Output Power                                 1.3 Watts

                Tx Freq. Range                               806-825 MHz

                Rx Freq. Range                               851-870 MHz

             Emission Designator                               20K0F1D

              Signal Modulation                                   FSK

                 Modes Tested                    Unmodulated Carrier, RD-LAP, MDC



© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                  1
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                       Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                                  Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________


   2.1 MEASUREMENT PROCEDURES

   2.2 OCCUPIED BANDWIDTH - §2.1049(c)
The antenna output terminal of the EUT was connected to the input of a 50Ω spectrum analyzer
through a matched 30dB attenuator. The radio transmitter was operating at maximum output
power with and without internal data modulation.

Test Results
A. UNMODULATED CARRIER – High power
30.0dBm conducted power with a 30dB matched attenuator and coaxial cable with a total loss of 1.0dB.
B. INTERNAL MODULATION
Please see attached test plots. 100% of the in-band modulation is below the specified mask per
90.210(g) for both RD-LAP and MDC protocols.

         Emission Mask 806-821MHz (DataTAC)


     FREQUENCY (MHz)                                   FORMULA                            LIMIT (dBc)

               -26500                                  43+10 log (P)                            - 46

                -0.050                                 43+10 log (P)                            - 46

                -0.050                                 50+10 log (P)                            - 53

               -0.0175                               116 log (fd / 6.1)                         - 53

                -0.010                      116 log (fd / 6.1) or 83 log ((fd / 5)              - 25

                -0.005                                 83 log ((fd / 5)                         0.0

                0.005                                  83 log ((fd / 5)                         0.0

                0.010                       116 log (fd / 6.1) or 83 log ((fd / 5)              - 25

                0.0175                               116 log (fd / 6.1)                         - 53

                0.050                                  50+10 log (P)                            - 53

                0.050                                  43+10 log (P)                            - 46

                26500                                  43+10 log (P)                            - 46

© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                   2
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                    Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                               Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________



   2.3 SPURIOUS AND HARMONIC EMISSIONS AT ANTENNA TERMINAL - §2.1051
The level of the carrier and the various conducted spurious and harmonic frequencies is measured
by means of a calibrated spectrum analyzer. The spectrum is scanned from 10MHz to 20GHz.
The transmitter is modulated with a 2500Hz tone at a level of 16dB greater than that required to
provided 50% modulation. The antenna output terminal of the EUT was connected to the input
of a 50Ω spectrum analyzer through a matched 30dB attenuator and coaxial cable. The
transmitter was operating at maximum power with and without internal data modulation.

   2.4 RADIATED SPURIOUS AND HARMONIC EMISSIONS - §2.1053
Radiated and harmonic emissions above 1 GHz were measured at our 3-meter outdoor site. The
EUT is placed on the turntable using the intended power source. A receiving antenna located 3
meters from the turntable receives any signal radiated from the transmitter and its operating
accessories. The receiving antenna is varied from 1 to 4 meters and the polarization is varied
(horizontal and vertical) to determine the worst-case emission level.

   2.5 FREQUENCY STABILITY/TEMPERATURE VARIATION - §2.1055
The frequency stability of the transmitter is measured by:
a) Temperature: The temperature is varied from -30°C to +60°C using an environmental
chamber.
b) Primary Supply Voltage: The primary supply voltage is varied from 85% to 115% of the
voltage normally at the input to the device or at the power supply terminals if cables are not
normally supplied. The EUT is tested down to the battery endpoint.
Specification – The minimum frequency stability shall be +/- 0.00025% at any time during normal operation.

Time Period and Procedure:
1. The carrier frequency of the transmitter and the individual oscillators is measured at room
   temperature (25°C to 27°C to provide a reference).
2. The equipment is subjected to an overnight “soak” at -30°C without any power applied.
3. After the overnight “soak” at -30°C (usually 14-16 hours), the equipment is turned on in a
   “standby” condition for one minute before applying power to the transmitter. Measurement
   of the carrier frequency of the transmitter and the individual oscillators is made within a three-
   minute interval after applying power to the transmitter.
4. Frequency measurements were made at 10°C intervals up to +60°C then back to room
   temperature. A minimum period of one and one half-hour is provided to allow stabilization
   of the equipment at each temperature level.




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                    3
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                  Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                             Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________


   3.1 TEST DATA


   3.2 EFFECTIVE RADIATED POWER OUTPUT - §2.1046


                                                                 ERP of EUT
                       Max. Field Polarization Dipole   Dipole
               EUT                                                Dipole Gain
       Freq.           Strength of             Gain    Forward         +
       Tuned Conducted    EUT                         Conducted Dipole Forward
              Power
                                                        Power Conducted Power

       (MHz)         (dBm)           (dBm)       (H/V)     (dBd)       (dBm)       dBm        Watts


         806          33.0           - 4.72        V       - 1.64      32.57       30.93      1.24

         815          33.0           - 7.16        V       - 1.54      32.71       31.17      1.31

         821          33.0            - 5.47       V       - 1.44      32.50       31.06      1.28



Notes:
ERP Measurements by Substitution Method:
The EUT was placed on a turntable 3-meters from the receive antenna. The field of maximum
intensity was found by rotating the EUT approximately 360 degrees and changing the height of the
receive antenna from 1 to 4 meters. The field strength was recorded from a calibrated spectrum
analyzer for each channel being tested. A half-wave dipole was substituted in place of the EUT. The
dipole was fed through a directional coupler and the power at the coupler port was monitored. A
signal generator and power amplifier controlled the dipole, and the input level of the dipole was
adjusted to the same field strength level as the EUT. The feed point for the dipole was then
connected to a calibrated power meter and the power adjusted to read the same as the coupler port
previously recorded, this is to account for any mismatch in impedance, which may occur at the
dipole antenna. The conducted power at the antenna feed point was recorded. The forward power
for the dipole was then determined and the ERP level was determined by adding the forward dipole
power and the dipole gain in dB. For readings above 1GHz the above method is repeated using
standard gain horn antennas.




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                  4
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                  Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                             Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________


3.3 FIELD STRENGTH OF SPURIOUS RADIATION – §2.1053


            Operating Frequency:             806 MHz
                            Channel:         Low
   Measured Conducted Power:                 33.00 dBm
                        Modulation:          unmodulated carrier
                            Distance:        3 meters
                                  Limit:     43 + 10 log10 (W) = 39.47 dBc



    Frequency               Level           AFCL          POL          ERP
                                                                                     (dBc)
                                                         (H/V)        (dBm)
         (MHz)             (dBm)             (dB)


         1612            < - 76.96          30.66          H          - 34.18        65.11
         2418            < - 75.89          34.33          H          - 29.44        60.37
         3224            < - 78.56          37.28          H          - 29.16        60.09
         4030            < - 79.53          40.44          H          - 26.97        57.90
         4836              < -100


    Notes:

    1. The bandwidth is set per §90.210 (RBW = 1MHz, VBW = 1MHz).
    2. The spectrum was checked from 10 MHz up to 20GHz.
    3. < -100dBm is below the floor of the spectrum analyzer.
    4. The EUT is manipulated through 3 orthogonal axis and the worst-case
       emission are reported.
    5. The EUT is placed 3.0 meters away from the receiving antenna and the ERP
       is calculated using the formula.
       ERP (dBm) = 10 Log 10 (((r(mV/m)/1 x 106)2 / 49.2/1 x 10-3)
       ERP (dBm) = 10 Log 10 [ (3 x FS/1 x 106)2 / (49.2) x 1000]
       ERP (Watts) = {(3 x FS)/1 x 106}2 / 49.2
       Note: The antenna factor and cable loss were determined prior to the test.




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                  5
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                  Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                             Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________




            Operating Frequency:             815 MHz
                            Channel:         Mid
   Measured Conducted Power:                 33.00dBm
                        Modulation:          unmodulated carrier
                            Distance:        3 meters
                                  Limit:     43 + 10 log10 (W) = 39.47 dBc



    Frequency               Level           AFCL          POL          ERP
                                                                                     (dBc)
                                                         (H/V)        (dBm)
         (MHz)             (dBm)             (dB)


         1630            < - 77.22          30.58          H          - 34.52        65.69
         2445            < - 76.10          34.25          H          - 29.73        60.90
         3260            < - 78.08          37.22          H          - 28.74        59.91
         4075            < - 76.83          40.33          H          - 24.38        55.55
         4890              < -100


    Notes:

    1. The bandwidth is set per §90.210 (RBW = 1MHz, VBW = 1MHz).
    2. The spectrum was checked from 10 MHz up to 20GHz.
    3. < -100dBm is below the floor of the spectrum analyzer.
    4. The EUT is manipulated through 3 orthogonal axis and the worst-case
       emission are reported.
    5. The EUT is placed 3.0 meters away from the receiving antenna and the ERP
       is calculated using the formula:
       ERP (dBm) = 10 Log 10 (((r(mV/m)/1 x 106)2 / 49.2/1 x 10-3)
       ERP (dBm) = 10 Log 10 [ (3 x FS/1 x 106)2 / (49.2) x 1000]
       ERP (Watts) = {(3 x FS)/1 x 106}2 / 49.2
       Note: The antenna factor and cable loss were determined prior to the test.




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                  6
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                  Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                             Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________



            Operating Frequency:             821 MHz
                            Channel:         High
   Measured Conducted Power:                 33.00 dBm
                        Modulation:          unmodulated carrier
                            Distance:        3 meters
                                  Limit:     43 + 10 log10 (W) = 39.47 dBc



    Frequency               Level           AFCL          POL          ERP
                                                                                     (dBc)
                                                         (H/V)        (dBm)
         (MHz)             (dBm)             (dB)


         1642             < - 77.57         30.55          H          - 34.90        65.96
         2463             < - 77.21         34.22          H          - 30.87        61.93
         3284             < - 78.80         37.15          H          - 29.53        60.59
         4105             < - 78.56         40.22          H          - 26.22        57.28
         4926              < -100


    Notes:

    1. The bandwidth is set per §90.210 (RBW = 1MHz, VBW = 1MHz).
    2. The spectrum was checked from 10 MHz up to 20GHz.
    3. < -100dBm is below the floor of the spectrum analyzer.
    4. The EUT is manipulated through 3 orthogonal axis and the worst-case
       emission are reported.
    5. The EUT is placed 3.0 meters away from the receiving antenna and the ERP
       is calculated using the formula:
       ERP (dBm) = 10 Log 10 (((r(mV/m)/1 x 106)2 / 49.2/1 x 10-3)
       ERP (dBm) = 10 Log 10 [ (3 x FS/1 x 106)2 / (49.2) x 1000]
       ERP (Watts) = {(3 x FS)/1 x 106}2 / 49.2
       Note: The antenna factor and cable loss were determined prior to the test.




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                  7
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                         Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                                    Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________


          3.4 FREQUENCY STABILITY - § 2.1055


                      Operating Frequency:               815,000,000             Hz

                                     Channel:                Mid
                          Reference Voltage:                 4.75                 VDC

                            Deviation Limit:    ± 0.00025 % or 2.5 ppm



              VOLTAGE               POWER        TEMP               FREQ.             Deviation
                   (%)               (VDC)        (ºC)              (Hz)                (%)

                  100 %                4.75     + 20 (Ref)      815,000,000           0.000000
                  100 %                           - 30          814,998,936           0.000131
                  100 %                           - 20          814,999,691           0.000038
                  100 %                           - 10          814,999,921           0.000010
                  100 %                             0           814,999,336           0.000081
                  100 %                           + 10          815,000,082           -0.000010
                  100 %                           + 20          814,999,232           0.000094
                  100 %                           + 25          814,999,829           0.000021
                  100 %                           + 30          814,999,785           0.000026
                  100 %                           + 40          814,999,969           0.000004
                  100 %                           + 50          815,000,551           -0.000068
                  100 %                           + 60          814,998,989           0.000124
                   85 %                N/A        + 20          815,000,000           0.000000
                  115 %                N/A        + 20          815,000,000           0.000000
            BATT. ENDPOINT             N/A        + 20          815,000,000           0.000000




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                     8
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                                                       Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                                                                  Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________


          FREQUENCY STABILITY - § 2.1055



                                                                   Frequency Stability
                             3.5




                             2.5




                             1.5
           Deviation (ppm)




                             0.5




                             -0.5




                             -1.5




                             -2.5




                             -3.5
                                    -20




                                                                   + 10



                                                                           + 20



                                                                                  + 25



                                                                                         + 30



                                                                                                + 40



                                                                                                       + 50



                                                                                                              + 60



                                                                                                                     + 20



                                                                                                                            + 20



                                                                                                                                   + 20
                                                               0
                                          - 30



                                                 - 20



                                                        - 10




                                                                          Temperature (°C)




© 2000 Celltech Research Inc.                         ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                                  9
                                                 Rugged Handheld PC with RIM 802 DataTAC Radio Modem


 CELLTECH RESEARCH INC.                                                         Test Report S/N: 100200-24KBC
 1955 Moss Court, Kelowna                                                    Dates of Tests: October 02-04, 2000
 B.C. CANADA V1Y 9L3
 ____________________________________________________________________________________________________________


    4.1 TEST EQUIPMENT

Type                                 Model                                Calib. Date         Serial No.

Signal Generator                     HP 8648D (9kHz-4.0GHz)                Nov 1999           3847A00611
Gigatronics Power Meter              8652A                                 Oct 1999           1835272
Gigatronics Power Sensor (2)         80701A (0.05-18GHz)                   Oct 1999        1833535, 1833542
Amplifier Research Power Amp. 5S1G4 (5W, 800MHz-4.2GHz)                    N/A                26235
Microwave System Amplifier           HP 83017A (0.5-26.5GHz)               N/A                3123A00587
Network Analyzer                     HP 8753E (30kHz-3GHz)                 Nov 1999           US38433013
Audio Analyzer                       HP 8903B                              March 1999         3729A18691
Modulation Analyzer                  HP 8901A                              March 1999         3749A07154
Frequency Counter                    HP 53181A (3GHz)                      May 1999           3736A05175
DC Power Supply                      HP E3611A                            N/A                 KR83015294
Multi-Device Controller              EMCO 2090                             N/A                9912-1484
Mini Mast                            EMCO 2075                             N/A                0001-2277
Turntable                            EMCO 2080-1.2/1.5                     N/A                0002-1002
Horn Antenna                         Chase BBHA 9120-A (0.7-4.8GHz)       Sept 1998           9120A-239
Horn Antenna                         Chase BBHA 9120-A (0.7-4.8GHz)       Sept 1998           9120A-240
Roberts Dipoles                      Compliance Design (2 sets) 3121C      June 2000
Spectrum Analyzer                    HP 8594E                              March 2000         3543A02721
Spectrum Analyzer                    HP E4408B                             Nov 1999           US39240170
Shielded Screen Room                 Lindgren R.F. 18W-2/2-0               N/A                16297
Environmental Chamber                ESPEC ECT-2 (Temperature/Humidity)   Feb 2000            0510154-B




 © 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                    10
                                 Rugged Handheld PC with RIM 802 DataTAC Radio Modem


CELLTECH RESEARCH INC.                                                  Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                             Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3
____________________________________________________________________________________________________________


   5.1 CONCLUSION

The data collected shows that the Itronix FeX21 Rugged Handheld PC with RIM 802 DataTAC
Radio Modem FCC ID: KBCFEX21RIM802 complies with all the requirements of Parts 2 and 90
of the FCC rules.




© 2000 Celltech Research Inc.        ITRONIX FeX21 FCC ID: KBCFEX21RIM802                                 11
                                Rugged Handheld PC with RIM 802 DataTAC Radio Modem


TEST PLOTS


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                            CONDUCTED SPURIOUS – Channel 806




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                            CONDUCTED SPURIOUS – Channel 806




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                            CONDUCTED SPURIOUS – Channel 806




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                            CONDUCTED SPURIOUS – Channel 815




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                            CONDUCTED SPURIOUS – Channel 815




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                                CONDUCTED SPURIOUS – Channel 815




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                                CONDUCTED SPURIOUS – Channel 821




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                                CONDUCTED SPURIOUS – Channel 821




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                                CONDUCTED SPURIOUS – Channel 821




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                                   OCCUPIED BANDWIDTH
                                       Channel 815
                                         RD-LAP




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                                   OCCUPIED BANDWIDTH
                                       Channel 815
                                          MDC




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem


CELLTECH RESEARCH INC.                                      Test Report S/N: 100200-24KBC
1955 Moss Court, Kelowna                                 Dates of Tests: October 02-04, 2000
B.C. CANADA V1Y 9L3



                                  OCCUPIED BANDWIDTH
                                      Channel 815
                                 UNMODULATED CARRIER




© 2000 Celltech Research Inc.       ITRONIX FCC ID: KBCFEX21RIM802
                                Rugged Handheld PC with DataTAC Radio Modem



Document Created: 2000-10-20 10:24:19
Document Modified: 2000-10-20 10:24:19

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC