MPE

FCC ID: KA2WR920VA1

RF Exposure Info

Download: PDF
FCCID_4290899

               FCC RF EXPOSURE REPORT
                            FCC ID: QIPBGS12

      Project No.     : 1901H008B
      Equipment       : U.S. Cellular Home Phone
      Model Name      : DWR-920V
      Series Model    : N/A
      Applicant       : D-Link Corporation
      Address         : No.289, Xinhu 3rd Rd., Neihu District, Taipei
                        11494, Taiwan

      According:      : FCC Guidelines for Human Exposure IEEE
                        C95.1 & FCC Part 2.1091




                   BTL                    INC.
          No.3,Jinshagang 1st Road, Shixia,Dalang Town, Dongguan,
                            Guangdong, China.
            TEL: +86-769-8318-3000     FAX: +86-769-8319-6000




Report No.: BTL-FCCP-4-1901H008B                                       Page 1 of 4
                                                                  Report Version: R00


  1. GENERAL SUMMARY

      Equipment :      U.S. Cellular Home Phone
      Brand Name :     N/A
      Test Model :     DWR-920V
      Series Model :   N/A
      Applicant    :   D-Link Corporation
      Manufacturer :   D-Link Corporation
      Address      :   No.289, Xinhu 3rd Rd., Neihu District, Taipei 11494, Taiwan
      Date of Test :   Jan. 22, 2019~ Jan. 28, 2019
      Test Sample :    Engineering Sample No.: B190100025
      Standards    :   FCC Title 47 Part 2.1091, OET Bulletin 65 Supplement C

   The above equipment has been tested and found compliance with the requirement of the relative
   standards by BTL Inc.
   The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
   BTL-FCCP-4-1901H008B) were obtained utilizing the test procedures, test instruments, test sites
   that has been accredited by the Authority of A2LA according to the ISO/IEC 17025 quality
   assessment standard and technical standard(s).




Report No.: BTL-FCCP-4-1901H008B                                                          Page 2 of 4
                                                                                     Report Version: R00


  2. MPE CALCULATION METHOD

          Calculation Method of RF Safety Distance:




         where:
         S = power density
         P = power input to the antenna
         G = power gain of the antenna in the direction of interest relative to an isotropic radiator
         R = distance to the center of radiation of the antenna


 Table for Filed Antenna:

 For Band 2
     Ant.        Brand                 P/N             Antenna Type     Connector       Gain(dBi)
      1           N/A                  N/A               External         N/A             4.1.

 For Band 5
     Ant.        Brand                 P/N             Antenna Type     Connector       Gain(dBi)
      1           N/A                  N/A               External         N/A            -0.83


 For Band 4
     Ant.        Brand                 P/N             Antenna Type     Connector       Gain(dBi)
      1           N/A                  N/A               External         N/A             2.73

 For Band 12
     Ant.        Brand                 P/N             Antenna Type     Connector       Gain(dBi)
      1           N/A                  N/A               External         N/A            -0.81

 For Band 66
     Ant.        Brand                 P/N             Antenna Type     Connector       Gain(dBi)
      1           N/A                  N/A               External         N/A             2.45




Report No.: BTL-FCCP-4-1901H008B                                                            Page 3 of 4
                                                                                       Report Version: R00


  3. TEST RESULTS

 For Band 2
                                                                Limit of Power
        Max EIRP            Max EIRP        Power Density (S)
                                                                  Density (S)       Test Result
         (dBm)               (mW)              (mW/cm2)
                                                                  (mW/cm2)
          26.64             461.3176                0.09182           1              Complies

 For Band 4
                                                                Limit of Power
        Max EIRP            Max EIRP        Power Density (S)
                                                                  Density (S)       Test Result
         (dBm)               (mW)              (mW/cm2)
                                                                  (mW/cm2)
          25.42             348.3373                0.06933           1              Complies

 For Band 66
                                                                Limit of Power
        Max EIRP            Max EIRP        Power Density (S)
                                                                  Density (S)       Test Result
         (dBm)               (mW)              (mW/cm2)
                                                                  (mW/cm2)
          25.61             363.9150                0.07244           1              Complies

 For Band 5

   ERP=EIRP-2.15

                                                                Limit of Power
        Max EIRP            Max EIRP        Power Density (S)
                                                                  Density (S)       Test Result
         (dBm)               (mW)              (mW/cm2)
                                                                  (mW/cm2)
          19.82              95.9401                0.01910           1              Complies

 For Band 12

   ERP=EIRP-2.15

                                                                Limit of Power
        Max EIRP            Max EIRP        Power Density (S)
                                                                  Density (S)       Test Result
         (dBm)               (mW)              (mW/cm2)
                                                                  (mW/cm2)
          21.87             153.8155                0.03062           1              Complies


 Note: the calculated distance is 20 cm.
        Output power including tune up tolerance.




                                         End of Test Report

Report No.: BTL-FCCP-4-1901H008B                                                      Page 4 of 4
                                                                                 Report Version: R00



Document Created: 2019-05-29 21:27:04
Document Modified: 2019-05-29 21:27:04