MPE Calculation

FCC ID: KA2WL8620APA1

RF Exposure Info

Download: PDF
FCCID_4148225

                                                           RF Exposure Report

                       Report No.: SA180424C01B

                             FCC ID: KA2WL8620APA1

                              Model: DWL-8620AP

                 Received Date: Apr. 24, 2018

                         Test Date: May. 21 ~ Oct. 01, 2018

                     Issued Date: Nov. 26, 2018


                         Applicant: D-Link Corporation

                           Address: 17595 Mt. Herrmann, Fountain Valley, California, United States, 92708



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: SA180424C01B                                              Page No. 1 / 6                                             Report Format Version: 6.1.1
Reference No.: 180910C13


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 6




Report No.: SA180424C01B                                             Page No. 2 / 6                                              Report Format Version: 6.1.1
Reference No.: 180910C13


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA180424C01           Original release                                   Nov. 26, 2018




Report No.: SA180424C01B                    Page No. 3 / 6        Report Format Version: 6.1.1
Reference No.: 180910C13


1    Certificate of Conformity


            Product: Unified AC Concurrent Dual-Band PoE Access Point

              Brand: D-Link Corporation

              Model: DWL-8620AP

    Sample Status: Engineering sample

          Applicant: D-Link Corporation

          Test Date: May. 21 ~ Oct. 01, 2018

         Standards: FCC Part 2 (Section 2.1091)
                           KDB 447498 D01 General RF Exposure Guidance v06
                           IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                              , Date:         Nov. 26, 2018
                                 Polly Chien / Specialist




     Approved by :                                               , Date:         Nov. 26, 2018
                              Bruce Chen / Project Engineer




Report No.: SA180424C01B                        Page No. 4 / 6                        Report Format Version: 6.1.1
Reference No.: 180910C13


2     RF Exposure
2.1     Limits for Maximum Permissible Exposure (MPE)

    Frequency Range          Electric Field     Magnetic Field       Power Density         Average Time
         (MHz)              Strength (V/m)      Strength (A/m)         (mW/cm2)              (minutes)
                             Limits For General Population / Uncontrolled Exposure
       300-1500                   …                    …                  F/1500                  30
      1500-100,000                …                    …                   1.0                    30
F = Frequency in MHz


2.2     MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


2.3     Classification
The antenna of this product, under normal use condition, is at least 37cm away from the body of the user. So,
this device is classified as Mobile Device.




Report No.: SA180424C01B                       Page No. 5 / 6                        Report Format Version: 6.1.1
Reference No.: 180910C13


3    Calculation Result of Maximum Conducted Power

Frequency Band        Max Power       Antenna Gain             Distance    Power Density            Limit
    (MHz)               (dBm)             (dBi)                  (cm)        (mW/cm2)             (mW/cm2)
                                                   CDD Mode

    2412-2462              29.53           9.02                  37            0.416                   1

    5180-5240              28.41           10.02                 37            0.405                   1

    5260-5320              22.65           10.02                 37            0.107                   1

    5500-5700              23.59           10.02                 37            0.133                   1

    5745-5825              29.66           10.02                 37            0.540                   1

                                             Beamforming Mode

    2412-2462              27.93           9.02                  37            0.288                   1

    5180-5240              27.03           10.02                 37            0.295                   1

    5260-5320              21.27           10.02                 37            0.078                   1

    5500-5700              22.21           10.02                 37            0.097                   1

    5745-5825              28.17           10.02                 37            0.383                   1

Note:
1. Directional gain:
2.4GHz Band: Directional gain = 3dBi + 10log(4) = 9.02dBi
5GHz Band: Directional gain = 4dBi +10log (4) = 10.02dBi
2. The above Max Power is Turn-up Power which client declaried.

Conclusion:
2.4GHz & 5GHz Band 1, 2 or 2.4GHz & 5GHz Band 3 or 2.4GHz & 5GHz Band 4 can transmit at same time.
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density

1. WLAN 2.4GHz + WLAN 5GHz Band 1 = 0.416 + 0.405 = 0.821
2. WLAN 2.4GHz + WLAN 5GHz Band 3 = 0.416 + 0.133 = 0.549
3. WLAN 2.4GHz + WLAN 5GHz Band 4 = 0.416 + 0.540 = 0.956


Therefore the maximum calculations of above situations are less than the “1” limit.




---END---




Report No.: SA180424C01B                      Page No. 6 / 6                           Report Format Version: 6.1.1
Reference No.: 180910C13



Document Created: 2019-03-21 23:53:59
Document Modified: 2019-03-21 23:53:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC