DFS Test Report

FCC ID: KA2WA182D1

Test Report

Download: PDF
FCCID_3627416

                           Test Report No.: RF170104N010-3



                                                                TEST REPORT
         Applicant                       D-Link Corporation

         Address                         17595 Mt. Herrmann, Fountain Valley, California, United States, 92708


          Manufacturer or
                                         HUNAN FULLRIVER HIGH TECHNOLOGY CO.,LTD
          Supplier
                                         FullRiver Industrial Area Economic Development Zone LiLing City HuNan
          Address
                                         Province China

          Product Name                   AC1200 MU-MIMO Wi-Fi USB Adapter

          Brand Name                     D-Link

          Model                          DWA-182

          Additional Model &
          Model Difference               N/A

          FCC ID                         KA2WA182D1

          Date of tests                  Jan. 25, 2017 ~ Aug. 26, 2017

          the tests have been carried out according to the requirements of the following standard:

               FCC Part 15, Subpart E, Section 15.407
               FCC 06-96

          CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                              Tested by Harry Li                                                         Approved by Glyn He
                     Project Engineer/ EMC Department                                                 Supervisor / EMC Department




                                                                                                              Date: Oct. 13, 2017
          This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark,
          is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The
          results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or
          any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof
          based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or
          omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to
          raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the
          tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into
          account to declare the compliance or non-compliance to the specification

                                                         No. 34, Chenwulu Section, Guantai Rd., Houjie                             Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                                    Town, Dongguan City,                                           Fax: +86 769 8593 1080
Dongguan Branch
                                                                  Guangdong 523942, China                                 Email: customerservice.dg@cn.bureauveritas.com
                                                                             Page 1 of 23                                                               Report Version 1


                          Test Report No.: RF170104N010-3

                                                   TABLE OF CONTENTS
          RELEASE CONTROL RECORD ............................................................................................................ 4

              1      EUT INFORMATION .................................................................................................................. 5
              1.1    OPERATING FREQUENCY BANDS AND MODE OF EUT ...................................................... 5
              1.2    EUT SOFTWARE AND FIRMWARE VERSION ........................................................................ 5
              1.3    DESCRIPTION OF AVAILABLE ANTENNAS TO THE EUT .................................................... 5
              1.4    TRANSMIT POWER CONTROL (TPC) ..................................................................................... 6
              1.5    STATEMENT OF MAUNFACTURER......................................................................................... 6

          2       U-NII DFS RULE REQUIREMENTS .............................................................................................. 7

              2.1    WORKING MODES AND REQUIRED TEST ITEMS ................................................................ 7
              2.2    TEST LIMITS AND RADAR SIGNAL PARAMETERS .............................................................. 8

          3       TEST & SUPPORT EQUIPMENT LIST ........................................................................................11


          3.1     TEST INSTRUMENTS ...................................................................................................................11


          3.2     DESCRIPTION OF SUPPORT UNITS ..........................................................................................11


          4       TEST PROCEDURE ..................................................................................................................... 12


          4.1     BVADT DFS MEASUREMENT SYSTEM: ................................................................................... 12


          4.2     CALIBRATION OF DFS DETECTION THRESHOLD LEVEL: .................................................... 13


          4.3     DEVIATION FROM TEST STANDARD ........................................................................................ 14


          4.4     CONDUCTED TEST SETUP CONFIGURATION ........................................................................ 14

                  4.4.1      Client without radar detection mode ................................................................................ 14

          5       TEST RESULTS ........................................................................................................................... 15


          5.1     SUMMARY OF TEST RESULTS.................................................................................................. 15


          5.2     DETAILED TEST RESULTS ........................................................................................................ 15

              5.2.1 TEST MODE: DEVICE OPERATING IN CLIENT WITHOUT RADAR DETECTION MODE ... 15
              5.2.2 DFS DETECTION THRESHOLD ............................................................................................. 16
              5.2.3 CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME .................................. 17
              5.2.4 NON- OCCUPANCY PERIOD .................................................................................................. 19

                                                        No. 34, Chenwulu Section, Guantai Rd., Houjie                          Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                                   Town, Dongguan City,                                        Fax: +86 769 8593 1080
Dongguan Branch
                                                                 Guangdong 523942, China                               Email: customerservice.dg@cn.bureauveritas.com
                                                                           Page 2 of 23                                                             Report Version 1


                           Test Report No.: RF170104N010-3

              5.2.5 NON-ASSOCIATED TEST ....................................................................................................... 21
              5.2.6 NON- CO-CHANNEL TEST ..................................................................................................... 21

          6       PHOTOGRAPHS OF THE TEST CONFIGURATION .................................................................. 22


          7       APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT
          BY THE LAB ......................................................................................................................................... 23




                                                         No. 34, Chenwulu Section, Guantai Rd., Houjie                            Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                                    Town, Dongguan City,                                          Fax: +86 769 8593 1080
Dongguan Branch
                                                                  Guangdong 523942, China                                 Email: customerservice.dg@cn.bureauveritas.com
                                                                             Page 3 of 23                                                              Report Version 1


                       Test Report No.: RF170104N010-3




                                       RELEASE CONTROL RECORD

           ISSUE NO.                REASON FOR CHANGE                                                     DATE ISSUED
           RF170104N010-3           Original release.                                                       Oct. 13, 2017




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                         Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                       Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 4 of 23                                                 Report Version 1


                       Test Report No.: RF170104N010-3


          1        EUT INFORMATION

          1.1       OPERATING FREQUENCY BANDS AND MODE OF EUT


           TABLE 1: OPERATING FREQUENCY BANDS AND MODE OF EUT
                                                               OPERATING FREQUENCY RANGE
                    OPERATIONAL MODE
                                                          5250~5350MHz                      5470~5725MHz
           Client without radar detection and
                                                                   V                                   V
                     ad hoc function


          Note: The EUT has disabled the 5600-5650MHz band


          1.2       EUT SOFTWARE AND FIRMWARE VERSION


           TABLE 2: THE EUT SOFTWARE/FIRMWARE VERSION

              NO.            PRODUCT                  MODEL NO.              SOFTWARE/FIRMWARE VERSION

                      AC1200 MU-MIMO Wi-Fi
               1
                          USB Adapter
                                                        DWA-182                                v4.00




          1.3       DESCRIPTION OF AVAILABLE ANTENNAS TO THE EUT


           TABLE 3: ANTENNA LIST
                                                                       FREQUENCY
                                      CONNECTOR             ANT                             NET              CABLE
           ANT.      BRAND      MODEL                                    RANGE
                                         TYPE              TYPE                           GAIN(dBi)         LOSS(dBi)
                                                                       (MHZ TO MHZ)
                                                                         5250 - 5350         2.79                   0
               1       N/A          N/A      N/A           PIFA
                                                                         5470 - 5725         4.21                   0
                                                                         5250 - 5350         2.79                   0
               2       N/A          N/A      N/A           PIFA
                                                                         5470 - 5725         4.21                   0




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie            Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                          Fax: +86 769 8593 1080
Dongguan Branch
                                                   Guangdong 523942, China                 Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 5 of 23                                                  Report Version 1


                       Test Report No.: RF170104N010-3


          1.4 TRANSMIT POWER CONTROL (TPC)
          U-NII devices operating in the 5.25-5.35 GHz band and the 5.47-5.725 GHz band
          shall employ a TPC mechanism. The U-NII device is required to have the capability
          to operate at least 6 dB below the mean EIRP value of 30 dBm. A TPC mechanism is
          not required for systems with an EIRP of less than 500 mW.

          Maximum EIRP of this device is 145.21 mW which less than 500mW, therefore it’s
          not require TPC function.




          1.5 STATEMENT OF MAUNFACTURER
          This device (Client) is without radar detection, then the manufacturer statement
          confirming that information regarding the parameters of the detected Radar
          Waveforms is not available to the end user. And the device doesn’t have Ad Hoc
          mode on DFS frequency band.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                 Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 6 of 23                                                 Report Version 1


                       Test Report No.: RF170104N010-3


          2     U-NII DFS RULE REQUIREMENTS

          2.1     WORKING MODES AND REQUIRED TEST ITEMS

          The manufacturer shall state whether the UUT is capable of operating as a Master
          and/or a Client. If the UUT is capable of operating in more than one operating mode
          then each operating mode shall be tested separately. See tables 1 and 2 for the
          applicability of DFS requirements for each of the operational modes.

                 TABLE 6: APPLICABILITY OF DFS REQUIREMENTS PRIOR TO USE A CHANNEL
                                                                        OPERATIONAL MODE
                     REQUIREMENT                                        CLIENT WITHOUT              CLIENT WITH
                                                     MASTER                 RADAR                     RADAR
                                                                          DETECTION                 DETECTION
                  Non-Occupancy Period
                 DFS Detection Threshold                                    Not required
              Channel Availability Check Time                               Not required             Not required
                    Uniform Spreading                                       Not required             Not required
                U-NII Detection Bandwidth                                   Not required


               TABLE 7: APPLICABILITY OF DFS REQUIREMENTS DURING NORMAL OPERATION
                                                                        OPERATIONAL MODE
                     REQUIREMENT                                        CLIENT WITHOUT              CLIENT WITH
                                                     MASTER                 RADAR                     RADAR
                                                                          DETECTION                 DETECTION
                 DFS Detection Threshold                                    Not required
          Channel Closing Transmission Time
                   Channel Move Time
                U-NII Detection Bandwidth                                   Not required




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie             Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                           Fax: +86 769 8593 1080
Dongguan Branch
                                                  Guangdong 523942, China                  Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 7 of 23                                                   Report Version 1


                       Test Report No.: RF170104N010-3


          2.2    TEST LIMITS AND RADAR SIGNAL PARAMETERS

                 DETECTION THRESHOLD VALUES

                TABLE 8: DFS DETECTION THRESHOLDS FOR MASTER DEVICES AND CLIENT
                                  DEVICES WITH RADAR DETECTION

                   MAXIMUM TRANSMIT POWER                                    VALUE (SEE Note 1 and 2)

                             ≥ 200 milliwatt                                               -64 dBm
                             < 200 milliwatt                                               -62 dBm
          Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.
          Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude
          of the test transmission waveforms to account for variations in measurement equipment. This
          will ensure that the test signal is at or above the detection threshold level to trigger a DFS
          response.


                                    TABLE 9: DFS RESPONSE REQUIREMENT VALUES

                             PARAMETER                                                     VALUE
          Non-occupancy period                                   Minimum 30 minutes
          Channel Availability Check Time                        60 seconds
          Channel Move Time                                      10 seconds
                                                                 See Note 1.
          Channel Closing Transmission Time                      200 milliseconds + an aggregate of 60
                                                                 milliseconds over remaining 10 second period.
                                                                 See Notes 1 and 2.
          U-NII Detection Bandwidth                              100% of the UNII transmission power bandwidth.
                                                                 See Note 3.
          Note 1: The instant that the Channel Move Time and the Channel Closing Transmission Time
          begins is as follows:
          • For the Short Pulse Radar Test Signals this instant is the end of the Burst.
          • For the Frequency Hopping radar Test Signal, this instant is the end of the last radar
          Burst generated.
          • For the Long Pulse Radar Test Signal this instant is the end of the 12 second period defining
          the Radar Waveform.
          Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at
          the beginning of the Channel Move Time plus any additional intermittent control signals
          required to facilitate a Channel move (an aggregate of 60 milliseconds) during the remainder of
          the 10 second period. The aggregate duration of control signals will not count quiet periods in
          between transmissions.
          Note 3: During the U-NII Detection Bandwidth detection test, radar type 1 is used and for each
          frequency step the minimum percentage of detection is 90 percent. Measurements are
          performed with no data traffic.

                                           No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 8 of 23                                                    Report Version 1


                       Test Report No.: RF170104N010-3
          PARAMETERS OF DFS TEST SIGNALS
          Step intervals of 0.1 microsecond for Pulse Width, 1 microsecond for PRI, 1 MHz for chirp
          width and 1 for the number of pulses will be utilized for the random determination of specific
          test waveforms.



                                    Table 10: Short Pulse Radar Test Waveforms
                                                                                      Minimum
                          Pulse                                                      Percentage              Minimum
            Radar                             PRI                 Number
                          Width                                                          of                  Number of
            Type                            (µsec)               of Pulses
                          (µsec)                                                     Successful                Trials
                                                                                      Detection
               0             1               1428                     18                  See Note 1         See Note 1
               1             1       Test A: 15 unique                                      60%                  30
                                          PRI values
                                     randomly selected
                                     from the list of 23
                                        PRI values in
                                           Table 5a
                                     ------------------------
                                       Test B: 15 unique
                                           PRI values
                                       randomly selected
                                         within the range
                                          of 518-3066
                                          µsec, with a
                                           minimum
                                       increment of 1
                                             µsec,
                                         excluding PRI
                                             values
                                          selected in
                                             Test A
               2            1-5           150-230                    23-29                  60%                      30
               3           6-10           200-500                    16-18                  60%                      30
               4          11-20           200-500                    12-16                  60%                      30
                            Aggregate (Radar Types 1-4)                                     80%                     120
           Note 1: Short Pulse Radar Type 0 should be used for the detection bandwidth test,
           channel move time, and channel closing time tests.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                                   Guangdong 523942, China                     Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 9 of 23                                                     Report Version 1


                       Test Report No.: RF170104N010-3


                                    TABLE 11: LONG PULSE RADAR TEST WAVEFORM

                                    CHIRP                                         MINIMUM
                       PULSE                     PRI         NUMBER                                              MINIMUM
           RADAR                                                       NUMBER PERCENTAGE OF
                       WIDTH        WIDTH                   OF PULSES                                           NUMBER OF
            TYPE                               (µsec)                 OF BURSTS SUCCESSFUL
                       (µsec)       (MHz)                   PER BURST                                             TRIALS
                                                                                 DETECTION

              5        50-100       5-20     1000-2000          1-3           8-20             80%                     30



                            TABLE 12: FREQUENCY HOPPING RADAR TEST WAVEFORM

                         PULSE                               HOPPING HOPPING     MINIMUM
                                                                                                                 MINIMUM
            RADAR                       PRI     PULSES        RATE   SEQUENCE PERCENTAGE OF
                         WIDTH                                                                                  NUMBER OF
             TYPE                     (µsec)    PER HOP               LENGTH   SUCCESSFUL
                         (µsec)                               (kHz)                                               TRIALS
                                                                      (msec)    DETECTION

               6            1          333          9          0.333          300              70%                     30




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie            Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                          Town, Dongguan City,                          Fax: +86 769 8593 1080
Dongguan Branch
                                                        Guangdong 523942, China                 Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 10 of 23                                                  Report Version 1


                       Test Report No.: RF170104N010-3


          3 TEST & SUPPORT EQUIPMENT LIST

           3.1     TEST INSTRUMENTS
                                          TABLE 1: TEST INSTRUMENTS LIST.
                 DESCRIPTION &                                                   CALIBRATED           CALIBRATED
                                           MODEL NO.               BRAND
                 MANUFACTURER                                                       DATE                 UNTIL
                  R&S Spectrum                    FSV7              R&S           Nov 25, 2016         Nov 24, 2017
                  Signal generator                8645A            Agilent        Aug 24, 2017         Aug 23, 2018




           3.2     DESCRIPTION OF SUPPORT UNITS

                                        TABLE 2: SUPPORT UNIT INFORMATION.

           NO.       PRODUCT            BRAND          MODEL NO.                    ID                    SPEC.


                   WIRELESS AC
            1                            D-Link           WMC-AC01           UZ7AP7131N                      N/A
                      MODULE

          NOTE: This device was functioned as a           Master     Slave device during the DFS test.


                                     TABLE 3: SOFTWARE/FIRMWARE INFORMATION.
                                                                                      SOFTWARE/FIRMWARE
           NO.             PRODUCT                        MODEL NO.
                                                                                           VERSION
                                                                                  1.0.0    Mon 04 Feb 2013
            1.     WIRELESS AC MODULE                      WMC-AC01               (version6.30.163.13.r373323
                                                                                  WLTEST)




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie             Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                      Town, Dongguan City,                           Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                  Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 11 of 23                                                  Report Version 1


                       Test Report No.: RF170104N010-3



          4 TEST PROCEDURE

           4.1     BVADT DFS MEASUREMENT SYSTEM:
               A complete DFS Measurement System consists of Radar signal generate system to
               generating the radar waveforms in Table 10, 11 and 12. The traffic monitoring system is
               specified to the type of unit under test (UUT).

          Conducted setup configuration of ADT DFS Measurement System

                                                                                                 Radar Signal Generating
                                    Control PC
                                                                                                       Subsystem




                                    Spectrum
                                    Analyzer                                                            Attenuator




                                      C/S




                  Attenuator                               Attenuator                                      C/S


                                                 Traffic Monitoring Subsystem

                  Support Unit                                                                           Master /
                                                                                                        Client with
                                                                                                       DFS function



          Channel Loading
          System testing will be performed with channel-loading using means appropriate to the data types that
          are used by the unlicensed device. The following requirements apply:


          a)   The data file must be of a type that is typical for the device (i.e., MPEG-2,
               MPEG-4, WAV, MP3, MP4, AVI, etc.) and must generally be transmitting in a
               streaming mode.
          b)   Software to ping the client is permitted to simulate data transfer but must
               have random ping intervals.
          c)   Timing plots are required with calculations demonstrating a minimum channel
               loading of approximately 17% or greater.
          d)   Unicast or Multicast protocols are preferable but other protocols may be
               used. The appropriate protocol used must be described in the test
               procedures.


                                                 No. 34, Chenwulu Section, Guantai Rd., Houjie               Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                            Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                                          Guangdong 523942, China                    Email: customerservice.dg@cn.bureauveritas.com
                                                                Page 12 of 23                                                     Report Version 1


                          Test Report No.: RF170104N010-3


           4.2     CALIBRATION OF DFS DETECTION THRESHOLD LEVEL:

              The measured channel is 5300MHz and 5500 MHz in 20MHz Bandwidth,
              5290MHz and 5530MHz in 80MHz Bandwidth. The radar signal was the same as
              transmitted channels, and injected into the antenna port of AP (master) or Client
              Device with Radar Detection, measured the channel closing transmission time
              and channel move time. The Master maximum transmit power was l 200mW. The
              Master antenna gain is 4.7dBi and required detection threshold is -57.3dBm
              (=-62+4.7)dBm.

          CONDUCTED SETUP CONFIGURATION OF CALIBRATION OF DFS DETECTION
          THRESHOLD LEVEL



                                     Control PC




                                     Spectrum                                                   Radar Signal Generating
                                     Analyzer                                                         Subsystem




                                                50Ω Load (Terminator)
                                                                                                   Attenuator


                                                  C/S



             50Ω Load          Attenuator                                                              C/S
                                                                        Attenuator
           (Terminator)




                                                No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                           Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                         Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                               Page 13 of 23                                                 Report Version 1


                       Test Report No.: RF170104N010-3


           4.3     DEVIATION FROM TEST STANDARD
          No deviation.

           4.4     CONDUCTED TEST SETUP CONFIGURATION


           4.4.1      CLIENT WITHOUT RADAR DETECTION MODE


                                Control PC




                                Spectrum                                                     Radar Signal Generating
                                Analyzer                                                           Subsystem




                                                                                                    Attenuator

                                    C/S




                                                                                                        C/S            Master
                  Attenuator                           Attenuator




                 Client (UUT)
                                     Notebook                                                                        Notebook




          The UUT is a U-NII Device operating in Client mode without radar detection. The radar test signals are
          injected into the Master Device.




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie               Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                        Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                                      Guangdong 523942, China                    Email: customerservice.dg@cn.bureauveritas.com
                                                            Page 14 of 23                                                     Report Version 1


                       Test Report No.: RF170104N010-3


          5      TEST RESULTS
           5.1      SUMMARY OF TEST RESULTS


                 CLAUSE                    TEST PARAMETER                           REMARKS               PASS/FAIL


                 15.407             DFS Detection Threshold                       Not Applicable                N/A

                 15.407             Channel Availability Check Time               Not Applicable                N/A

                 15.407             Channel Move Time                                Applicable                Pass

                 15.407             Channel Closing Transmission Time                Applicable                Pass

                 15.407             Non- Occupancy Period                            Applicable                Pass

                 15.407             Uniform Spreading                             Not Applicable                N/A

                 15.407             U-NII Detection Bandwidth                     Not Applicable                N/A

                 15.407             Non-associated test                              Applicable                Pass

                 15.407             Non-Co-Channel test                              Applicable                Pass




           5.2      DETAILED TEST RESULTS

              5.2.1     TEST MODE: DEVICE OPERATING IN CLIENT WITHOUT RADAR
                        DETECTION MODE

          The radar test signals are injected into the Master Device.
          This test was investigated for different bandwidth (20MHz and 80MHz). The following
          plots was done on 80MHz as a representative




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie            Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                        Town, Dongguan City,                          Fax: +86 769 8593 1080
Dongguan Branch
                                                      Guangdong 523942, China                 Email: customerservice.dg@cn.bureauveritas.com
                                                            Page 15 of 23                                                  Report Version 1


                       Test Report No.: RF170104N010-3


               5.2.2      DFS DETECTION THRESHOLD


          The Required detection threshold is -57.30dBm = -62 +4.7dBi. The conducted radar
          burst level is set to -57.30dBm.




                                                                                 Radar signal




                                                                                Noise Floor




                                                Radar Signal (Type 0)




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie                 Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                               Fax: +86 769 8593 1080
Dongguan Branch
                                                 Guangdong 523942, China                      Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 16 of 23                                                       Report Version 1


                       Test Report No.: RF170104N010-3


               5.2.3      CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME

          11ac (VHT 80 MHz ) 5290MHz


                                    Radar Signal




                                      Traffic Signal


                                                             Noise Floor




          NOTE: T1 denotes the start of Channel Move Time upon the end of the last Radar burst. T2 denotes
          the data transmission time of 200ms from T1. T4 denotes the 10 second from T1 to observe the
          aggregate duration of transmissions.




                                                                       Radar Signal




                                                                                                                   Noise Floor




          NOTE: An expanded plot for the device vacates the channel in the required 500ms.




                                                   No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                              Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                            Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                                  Page 17 of 23                                                  Report Version 1


                       Test Report No.: RF170104N010-3


          11ac (VHT 80 MHz ) 5530MHz



                                    Radar Signal




                                      Traffic Signal


                                                          Noise Floor




          NOTE: T1 denotes the start of Channel Move Time upon the end of the last Radar burst. T2 denotes
          the data transmission time of 200ms from T1. T4 denotes the 10 second from T1 to observe the
          aggregate duration of transmissions.




                                                                 Radar Signal




                                                                                                          Noise Floor




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                          Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                        Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 18 of 23                                                 Report Version 1


                       Test Report No.: RF170104N010-3

               5.2.4      NON- OCCUPANCY PERIOD

          ASSOCIATED TEST

                 1) Test results demonstrating an associated client link is established with the master on a
                 test frequency.




                 EUT (Client ) links with master on 5530MHz


                 2) The client and DFS-certified master device are associated, and the movie can be
                 streamed as specified in the DFS Order for a non-occupancy period test.




                 Client transmitting a specified files to master.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                   Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 19 of 23                                                 Report Version 1


                       Test Report No.: RF170104N010-3




           3). The device transmits one type of radar as specified in the DFS Order.




           Radar 1 is used to test during DFS testing.



           4) The test frequency has been monitored to ensure no transmission of any type has occurred for 30
           minutes;
           Note: If the client moves with the master, the device is considered compliant if nothing appears in
           the client non-occupancy period test. For devices that shut down (rather than moving channels), no
           beacons should appear;
           5)An analyzer plot that contains a single 30-minute sweep on the original test frequency.



                                    Injected into Radar




                                     Traffic Signal




                                                      No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                                 Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                               Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                                     Page 20 of 23                                                 Report Version 1


                       Test Report No.: RF170104N010-3

               5.2.5        NON-ASSOCIATED TEST


          Master was off.
          During the 30 minutes observation time, The UUT did not make any transmissions in
          the DFS band after UUT power up.




               5.2.6      NON- CO-CHANNEL TEST


          The UUT was investigated after radar was detected the channel and made sure no
          co-channel operation with radars.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                 Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 21 of 23                                                 Report Version 1


                       Test Report No.: RF170104N010-3


          6 PHOTOGRAPHS OF THE TEST CONFIGURATION

          Please refer to the attached file (Test Setup Photo).




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                 Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 22 of 23                                                 Report Version 1


                       Test Report No.: RF170104N010-3


          7     APPENDIX A - MODIFICATIONS RECORDERS FOR
                ENGINEERING CHANGES TO THE EUT BY THE LAB

           No any modifications are made to the EUT by the lab during the test.




           ---END---




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                 Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 23 of 23                                                 Report Version 1



Document Created: 2017-10-24 17:14:45
Document Modified: 2017-10-24 17:14:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC