RF Exposure Info

FCC ID: KA2SPW320A1

RF Exposure Info

Download: PDF
FCCID_4415632

                                        FCC RF EXPOSURE REPORT

                                                            For

                                           Outdoor Wi-Fi Smart Plug

                                        MODEL NUMBER: DSP-W320

                                              FCC ID: KA2SPW320A1

                                     REPORT NUMBER: 4789094859-4

                                          ISSUE DATE: July 30, 2019



                                                      Prepared for

                                    D-Link Corporation
                17595 Mt. Herrmann, Fountain Valley, California, United States

                                    Prepared by
     UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
          Building 10, Innovation Technology Park, No. 1, Li Bin Road,
Song Shan Lake Hi-Tech Development Zone, Dongguan, People’s Republic of China
                              Tel: +86 769-22038881
                              Fax: +86 769 33244054
                              Website: www.ul.com




The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report
shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the
test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to
other similar products. This report does not imply that the product(s) has met the criteria for certification.


                                                                                             REPORT No.: 4789094859-4
                                                                                                      Page 2 of 6



                                            TABLE OF CONTENTS
1.   ATTESTATION OF TEST RESULTS .................................................................................... 3

2.   TEST METHODOLOGY ........................................................................................................ 3

3.   FACILITIES AND ACCREDITATION .................................................................................... 4

4.   REQUIREMENT .................................................................................................................... 5




                    UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
      This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                   (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                   REPORT No.: 4789094859-4
                                                                                            Page 3 of 6

1. ATTESTATION OF TEST RESULTS
Applicant Information
Company Name:                      D-Link Corporation
Address:                           17595 Mt. Herrmann, Fountain Valley, California, United States


Manufacturer Information
Company Name:                      D-Link Corporation
Address:                           17595 Mt. Herrmann, Fountain Valley, California, United States

EUT Information
EUT Name:                          Outdoor Wi-Fi Smart Plug
Model:                             DSP-W320
Brand Name:                        D-Link
Sample Status:                     Normal
Sample ID:                         1000747766
Sample Received Date:              July 17, 2019
Date of Tested:                    July 17~30, 2019

                                        APPLICABLE STANDARDS
                              STANDARD                                                 TEST RESULTS
                        FCC 47CFR§2.1091                                                    PASS
                       KDB-447498 D01 V06


Prepared By:                                                     Checked By:




Kebo Zhang                                                     Shawn Wen
Engineer Project Associate                                     Laboratory Leader


Approved By:




Stephen Guo
Laboratory Manager


                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                   REPORT No.: 4789094859-4
                                                                                            Page 4 of 6

2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with KDB 447498 D01
General RF Exposure Guidance v06.


3. FACILITIES AND ACCREDITATION
                        A2LA (Certificate No.: 4102.01)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been assessed and proved to be in compliance with A2LA.
                        FCC (FCC Designation No.: CN1187)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        Has been recognized to perform compliance testing on equipment subject
                        to the Commission's Delcaration of Conformity (DoC) and Certification
                        rules
                        ISED(Company No.: 21320)
Accreditation
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
Certificate
                        has been registered and fully described in a report filed with
                        Industry Canada. The Company Number is 21320.
                        VCCI (Registration No.: G-20019, R-20004, C-20012 and T-20011)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been assessed and proved to be in compliance with VCCI, the
                        Membership No. is 3793.
                        Facility Name:
                        Chamber D, the VCCI registration No. is G-20019 and R-20004
                        Shielding Room B , the VCCI registration No. is C-20012 and T-20011

Note 1: All tests measurement facilities use to collect the measurement data are located at
Building 10, Innovation Technology Park, Song Shan Lake Hi tech Development Zone,
Dongguan, 523808, China

Note 2: The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd.
Song Shan Lake Branch had been calibrated and compared to the open field sites and the test
anechoic chamber is shown to be equivalent to or worst case from the open field site.

Note 3: For below 30MHz, lab had performed measurements at test anechoic chamber and
comparing to measurements obtained on an open field site. And these measurements below
30MHz had been correlated to measurements performed on an OFS.




                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                   REPORT No.: 4789094859-4
                                                                                            Page 5 of 6

4. REQUIREMENT
LIMIT
Limits for General Population/Uncontrolled Exposure

                         Limits for General Population/Uncontrolled Exposure
                         Electric Field      Magnetic Field               Power                   Averaging Time
 Frequency Range                                                                                      2     2
                         Strength (E)        Strength (H)              Density (S)                 |E| , |H| or S
   (MHz)                                                                        2
                           (V/m)                (A/m)                  (mW/cm )                      (minutes)
      0.3-1.34               614                  1.63                    (100)*                          30
      1.34-30                824/f                2.19/f                 (180/f2)*                        30
       30-300                27.5                 0.073                     0.2                           30
     300-1500                  --                   --                     f/150                          30
   1500-100,000                --                   --                      1.0                           30
Note 1: f = frequency in MHz, * means Plane-wave equivalent power density

Note 2: General population/uncontrolled exposures apply in situations in which the general
public may be exposed, or in which persons that are exposed as a consequence of their
employment may not be fully aware of the potential for exposure or cannot exercise control over
their exposure.

Note 3: The limit value 1.0mW/cm2 is available for this EUT.



MPE CALCULATION METHOD

             2
S =PG/(4πR )


where: S = power density (in appropriate units, e.g. mW/ cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)




                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.


                                                                                   REPORT No.: 4789094859-4
                                                                                            Page 6 of 6
CALCULATED RESULTS

Radio Frequency Radiation Exposure Evaluation

                                               BLE (Worst case)
      Operating        Max. Tune up Power               Antenna Gain             Power density
                                                                                                          Limit
       Mode                      (dBm)                 (dBi)        (num)          (mW/ cm2 )

         BLE                        5                   2.0          1.58           0.000997                1



                                           WIFI 2.4G (Worst case)
      Operating        Max. Tune up Power              Directional Gain          Power density
                                                                                                          Limit
       Mode                      (dBm)                 (dBi)        (num)          (mW/ cm2 )

       802.11b                     17                   2.0          1.58             0.0158                1



Note:
   1. The calculated distance is 20cm.
   2. WLAN 2.4G & BT can’t transmit simultaneously. (declared by client)




                                            END OF REPORT




                 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.



Document Created: 2019-08-27 10:12:45
Document Modified: 2019-08-27 10:12:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC