Test Report

FCC ID: KA2SM22AA1

Test Report

Download: PDF
FCCID_1336132

             Compliance Certification Services Inc.
             Report No.: T100617011-RP1     FCC ID: KA2SM22AA1           Date of Issue: September 1, 2010



                         FCC 47 CFR PART 15 SUBPART C


                                       TEST REPORT


                                               For


                                     Remote controller


                         Model Number: DSM-22A, DSM-22


                                   Trade Name: D-Link

                                             Issued to

                                    D-Link Corporation
                     17595 Mt. Herrmann Fountain Valley California
                                  92708 United States

                                             Issued by

                       Compliance Certification Services Inc.
                     No. 11, Wu-Gong 6th Rd., Wugu Industrial Park,
                            Taipei Hsien 248, Taiwan (R.O.C.)
                                  http://www.ccsrf.com
                                    service@ccsrf.com




Note: This report shall not be reproduced except in full, without the written approval of Compliance
 Certification Services Inc. This document may be altered or revised by Compliance Certification
      Services Inc. personnel only, and shall be noted in the revision section of the document.



                                               Page 1                                      Total Page: 29
                                                                                                 Rev. 00


                       Compliance Certification Services Inc.
                       Report No.: T100617011-RP1                     FCC ID: KA2SM22AA1                          Date of Issue: September 1, 2010




                                                  TABLE OF CONTENTS
1.    TEST RESULT CERTIFICATION................................................................................................. 3

2.    EUT DESCRIPTION....................................................................................................................... 4

3.     TEST METHODOLOGY................................................................................................................ 5
     3.1   EUT CONFIGURATION ................................................................................................................. 5
     3.2   EUT EXERCISE ............................................................................................................................. 5
     3.3   GENERAL TEST PROCEDURES...................................................................................................... 5
     3.4   FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS.................................................. 6
     3.5   DESCRIPTION OF TEST MODES .................................................................................................... 6

4.    INSTRUMENT CALIBRATION.................................................................................................... 7
     4.1   MEASURING INSTRUMENT CALIBRATION ............................................................................... 7
     4.2   MEASUREMENT EQUIPMENT USED .................................................................................. 7
     4.3   MEASUREMENT UNCERTAINTY ........................................................................................ 8

5.     FACILITIES AND ACCREDITATIONS....................................................................................... 9
     5.1   FACILITIES .................................................................................................................................. 9
     5.2   EQUIPMENT................................................................................................................................. 9
     5.3   TABLE OF ACCREDITATIONS AND LISTINGS .............................................................................. 10

6.     SETUP OF EQUIPMENT UNDER TEST.................................................................................... 11
     6.1   SETUP CONFIGURATION OF EUT ................................................................................................ 11
     6.2   SUPPORT EQUIPMENT ........................................................................................................ 11

7.    FCC PART 15.249 REQUIREMENTS......................................................................................... 12
     7.1   20 DB BANDWIDTH.............................................................................................................. 12
     7.2   BAND EDGES MEASUREMENT ......................................................................................... 15
     7.3   SPURIOUS EMISSION .......................................................................................................... 20
     7.4   POWERLINE CONDUCTED EMISSIONS ........................................................................... 28

APPENDIX I PHOTOGRAPHS OF TEST SETUP ............................................................................ 29

APPENDIX 1 - PHOTOGRAPHS OF EUT




                                                                           Page 2                                                                     Rev. 00


                Compliance Certification Services Inc.
                Report No.: T100617011-RP1   FCC ID: KA2SM22AA1         Date of Issue: September 1, 2010




1. TEST RESULT CERTIFICATION
Applicant:                      D-Link Corporation
                                17595 Mt. Herrmann Fountain Valley California
                                92708 United States
Equipment Under Test:           Remote controller
Trade Name:                     D-Link
Model Number:                   DSM-22A, DSM-22
Date of Test:                   June 18 ~ September 1, 2010

                                  APPLICABLE STANDARDS
                    STANDARD                                        TEST RESULT
          FCC 47 CFR Part 15 Subpart C                         No non-compliance noted


We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data, data
evaluation, test procedures, and equipment configurations shown in this report were made in
accordance with the procedures given in ANSI C63.4: 2003 and the energy emitted by the
sample EUT tested as described in this report is in compliance with the requirements emission
limits of FCC Rules Part 15.207, 15.209 and 15.249.
The test results of this report relate only to the tested sample identified in this report.

Approved by:                                            Reviewed by:




Rex Lai                                                 Gina Lo
Section Manager                                         Section Manager
Compliance Certification Services Inc.                  Compliance Certification Services Inc.




                                               Page 3                                            Rev. 00


              Compliance Certification Services Inc.
              Report No.: T100617011-RP1    FCC ID: KA2SM22AA1      Date of Issue: September 1, 2010




2. EUT DESCRIPTION
Product                   Remote controller

Trade Name                D-Link

Model Number              DSM-22A, DSM-22
                          All the specification and layout are identical except they come with
Model Discrepancy
                          different model numbers for marketing purposes.
Power Supply              Coin-cell Battery: 3V (CR2032)

Frequency Range           2400 ~ 2483.5 MHz

Operating Frequency       2403 ~ 2475MHz

Frequency Number          73 Channels

Channel Spacing           1MHz

Modulation Technique GFSK

Antenna Gain              0.88 dBi

Antenna Designation       Printed Antenna

Remark:
   1.     The sample selected for test was production product and was provided by
          manufacturer.
   2.     This submittal(s) (test report) is intended for FCC ID: KA2SM22AA1 filing to comply
          with Section 15.107, 15.109, 15.207, 15.209, 15.249 (FCC Part 15, Subpart C Rules.)




                                              Page 4                                         Rev. 00


              Compliance Certification Services Inc.
              Report No.: T100617011-RP1   FCC ID: KA2SM22AA1        Date of Issue: September 1, 2010




3. TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.4: 2003 and
FCC CFR 47 Part 15.207, 15.209 and 15.249.
3.1 EUT CONFIGURATION
The EUT configuration for testing is installed on RF field strength measurement to meet the
Commissions requirement and operating in a manner that intends to maximize its emission
characteristics in a continuous normal application.
3.2 EUT EXERCISE
The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose
of the measurements.
According to its specifications, the EUT must comply with the requirements of the Section
15.207, 15.209,15.249 under the FCC Rules Part 15 Subpart C.
3.3 GENERAL TEST PROCEDURES
Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the
requirements in Section 13.1.4.1 of ANSI C63.4: 2003 Conducted emissions from the EUT
measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-peak and
average detector modes.

Radiated Emissions
The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate
360 degrees to determine the position of maximum emission level. EUT is set 3m away from the
receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each
emission was to be maximized by changing the polarization of receiving antenna both horizontal
and vertical. In order to find out the maximum emissions, exploratory radiated emission
measurements were made according to the requirements in Section 13.1.4.1 of ANSI C63.4:
2003.




                                             Page 5                                           Rev. 00


                Compliance Certification Services Inc.
                Report No.: T100617011-RP1   FCC ID: KA2SM22AA1       Date of Issue: September 1, 2010




3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
(a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in
    any of the frequency bands listed below:

               MHz                     MHz                   MHz                    GHz
           0.090 - 0.110          16.42 - 16.423           399.9 - 410           4.5 - 5.15
           1
           0.495 - 0.505       16.69475 - 16.69525          608 - 614            5.35 - 5.46
         2.1735 - 2.1905       16.80425 - 16.80475         960 - 1240            7.25 - 7.75
          4.125 - 4.128            25.5 - 25.67            1300 - 1427           8.025 - 8.5
        4.17725 - 4.17775          37.5 - 38.25           1435 - 1626.5           9.0 - 9.2
        4.20725 - 4.20775            73 - 74.6           1645.5 - 1646.5          9.3 - 9.5
          6.215 - 6.218             74.8 - 75.2            1660 - 1710           10.6 - 12.7
        6.26775 - 6.26825          108 - 121.94          1718.8 - 1722.2        13.25 - 13.4
        6.31175 - 6.31225           123 - 138              2200 - 2300          14.47 - 14.5
          8.291 - 8.294           149.9 - 150.05           2310 - 2390          15.35 - 16.2
          8.362 - 8.366            156.52475 -            2483.5 - 2500          17.7 - 21.4
        8.37625 - 8.38675           156.52525              2655 - 2900          22.01 - 23.12
        8.41425 - 8.41475         156.7 - 156.9            3260 - 3267           23.6 - 24.0
          12.29 - 12.293        162.0125 - 167.17          3332 - 3339           31.2 - 31.8
       12.51975 - 12.52025        167.72 - 173.2          3345.8 - 3358         36.43 - 36.5
       12.57675 - 12.57725          240 - 285              3600 - 4400                (2)
          13.36 - 13.41            322 - 335.4
   1
       Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
   2
       Above 38.6

(b) Except as provided in paragraphs (d) and (e), the field strength of emissions appearing within
    these frequency bands shall not exceed the limits shown in Section 15.209. At frequencies
    equal to or less than 1000 MHz, compliance with the limits in Section 15.209 shall be
    demonstrated using measurement instrumentation employing a CISPR quasi-peak detector.
    Above 1000 MHz, compliance with the emission limits in Section 15.209 shall be
    demonstrated based on the average value of the measured emissions. The provisions in
    Section 15.35 apply to these measurements.
3.5 DESCRIPTION OF TEST MODES
The EUT (model: DSM-22A) had been tested under operating condition.
After verification, all tests were carried out with the worst case test modes as shown below
except radiated spurious emission below 1GHz, which worst case was in normal link mode only.
Channel Low(2403MHz), Channel Mid(2440MHz) and Channel High(2475MHz) were chosen for
the final testing.
The field strength of spurious emission was measured in the following position: EUT stand-up
position (Z axis), lie-down position (X, Y axis). The worst emission was found in lie-down
position (X axis) and the worst case was recorded.




                                               Page 6                                           Rev. 00


               Compliance Certification Services Inc.
               Report No.: T100617011-RP1   FCC ID: KA2SM22AA1          Date of Issue: September 1, 2010



4. INSTRUMENT CALIBRATION
4.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein, has
been calibrated in accordance with the manufacturer's recommendations for utilizing calibration
equipment, which is traceable to recognized national standards.
4.2 MEASUREMENT EQUIPMENT USED
Equipment Used for Emissions Measurement
Remark: Each piece of equipment is scheduled for calibration once a year and Loop Antenna is
scheduled for calibration once three years.
                                     3M Semi Anechoic Chamber
   Name of Equipment       Manufacturer         Model           Serial Number      Calibration Due
   Spectrum Analyzer          Agilent           E4446A           US42510252           10/26/2010
    EMI Test Receiver          R&S               ESCI              100064             02/04/2011
      Pre-Amplifier        Mini-Circults      ZFL-1000LN        SF350700823           01/13/2011
                                            AFS44-00102650-
      Pre-Amplifier           MITEQ                               1415367             11/20/2010
                                               42-10P-44
     Bilog Antenna        Sunol Sciences          JB3             A030105             09/11/2010
      Horn Antenna            EMCO               3117             00055165            12/07/2010
      Loop Antenna            EMCO               6502             8905/2356           06/10/2013
       Turn Table              CCS             CC-T-1F              N/A                  N.C.R
     Antenna Tower             CCS             CC-A-1F              N/A                  N.C.R
       Controller              CCS             CC-C-1F              N/A                  N.C.R
        Site NSA               CCS               N/A                N/A               12/31/2010
        Test S/W                                   EZ-EMC (CCS-3A1RE)




                                               Page 7                                            Rev. 00


                 Compliance Certification Services Inc.
                 Report No.: T100617011-RP1      FCC ID: KA2SM22AA1             Date of Issue: September 1, 2010




4.3 MEASUREMENT UNCERTAINTY
                   PARAMETER                                  UNCERTAINTY
3M Semi Anechoic Chamber / 30M~200M                                +/- 4.0606
3M Semi Anechoic Chamber / 200M~1000M                              +/- 3.9979
3M Semi Anechoic Chamber / 1G~8G                                   +/- 2.5790
3M Semi Anechoic Chamber / 8G~18G                                  +/- 2.5928
3M Semi Anechoic Chamber / 18G~26G                                 +/- 2.7212
3M Semi Anechoic Chamber / 26G~40G                                 +/- 2.9520
Remark: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level
         using a coverage factor of k=2.




                                                     Page 8                                              Rev. 00


               Compliance Certification Services Inc.
               Report No.: T100617011-RP1   FCC ID: KA2SM22AA1        Date of Issue: September 1, 2010



5. FACILITIES AND ACCREDITATIONS
5.1 FACILITIES
All measurement facilities used to collect the measurement data are located at

    No. 199, Chunghsen Road, Hsintien City, Auerbach / Opf GERMANY
    Tel: 886-2-2217-0894 / Fax: 886-2-2217-1029

    No.11, Wugong 6th Rd., Wugu Industrial Park, Taipei Hsien 248, Taiwan
    Tel: 886-2-2299-9720 / Fax: 886-2-2298-4045

    No.81-1, Lane 210, Bade 2nd Rd., Luchu Hsiang, Taoyuan Hsien 338, Taiwan
    Tel: 886-3-324-0332 / Fax: 886-3-324-5235
The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and
CISPR Publication 22.
5.2 EQUIPMENT
Radiated emissions are measured with one or more of the following types of linearly polarized
antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum
analyzers with pre-selectors and quasi-peak detectors are used to perform radiated
measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and EMI Test
Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for
making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring
Apparatus and Measurement Methods.”




                                              Page 9                                           Rev. 00


                 Compliance Certification Services Inc.
                 Report No.: T100617011-RP1       FCC ID: KA2SM22AA1             Date of Issue: September 1, 2010




5.3 TABLE OF ACCREDITATIONS AND LISTINGS
 Country Agency Scope of Accreditation                                                   Logo

                        3M Semi Anechoic Chamber (FCC MRA: TW1039) to perform
 USA         FCC
                        FCC Part 15 measurements
                                                                                         FCC MRA: TW1039
                        LP0002, RTTE01, FCC Method-47 CFR Part 15 Subpart C, D, E,
                        RSS-210, RSS-310
                        IDA TS SRD, AS/NZS 4268, AS/NZS 4771, TS 12.1 & 12,2,
                        ETSI EN 300 440-1, ETSI EN 300 440-2, ETSI EN 300 328,
                        ETSI EN 300 220-1, ETSI EN 300 220-2, ETSI EN 301 893,
                        ETSI EN 301 489-1/3/7/17
 Taiwan      TAF
                        FCC OET Bulletin 65 + Supplement C,
                        EN 50360, EN 50361, EN 50371, RSS 102, EN 50383, EN 50385,
                        EN 50392, IEC 62209, CNS 14958-1, CNS 14959
                        FCC Method –47 CFR Part 15 Subpart B
                        IEC / EN 61000-3-2, IEC / EN 61000-3-3,
                        IEC / EN 61000-4-2/3/4/5/6/8/11

             Industry
 Canada                 3M Semi Anechoic Chamber (IC 2324G-1 / IC 2324G-2) to perform    IC 2324G-1
             Canada
                                                                                         IC 2324G-2

* No part of this report may be used to claim or imply product endorsement by A2LA or any agency of the US
  Government.




                                                     Page 10                                                 Rev. 00


                     Compliance Certification Services Inc.
                     Report No.: T100617011-RP1   FCC ID: KA2SM22AA1          Date of Issue: September 1, 2010




6. SETUP OF EQUIPMENT UNDER TEST
6.1 SETUP CONFIGURATION OF EUT
See test photographs attached in Appendix I for the actual connections between EUT and support
equipment.
6.2 SUPPORT EQUIPMENT
  No Equipment            Model    Serial No.     FCC ID       Trade Name     Data Cable       Power Cord
                                                                                           AC I/P:
                                                                                           Unshielded, 1.8m
            Notebook PC
  1.                      DELL        PP19L       GK102 A00    QDS-BRCM1021      N/A       DC O/P:
             (Remote)
                                                                                           Unshielded, 1.8m
                                                                                           with a core

Remark:
       1.      All the equipment/cables were placed in the worst-case configuration to maximize the
               emission during the test.
       2.      Grounding was established in accordance with the manufacturer’s requirements and
               conditions for the intended use.




                                                     Page 11                                             Rev. 00


                   Compliance Certification Services Inc.
                   Report No.: T100617011-RP1   FCC ID: KA2SM22AA1        Date of Issue: September 1, 2010



7. FCC PART 15.249 REQUIREMENTS
7.1 20 DB BANDWIDTH

LIMIT
None; for reporting purposes only.
Test Configuration


                                                                 Antenna
                                                                  tower


                          3m                                     Horn
                                                                antenna
     EUT
                               4m
                                                                 Spectrum
                                                                 analyzer


           Turntable                1m
                       0.8m
                                                                     Pre-amp




TEST PROCEDURE
1.    Place the EUT on the table and set it in the transmitting mode.
2.    Remove the antenna from the EUT and then connect a low loss RF cable from the antenna
      port to the spectrum analyzer.
3.    Set the spectrum analyzer as RBW=20kHz, VBW = 62kHz, Span = 5MHz, Sweep = auto.
4.    Mark the peak frequency and 20dB (upper and lower) frequency.
5.    Repeat until all the rest channels are investigated.

TEST RESULTS
No non-compliance noted

Test Data
                Frequency      20dB Bandwidth
 Channel
                  (MHz)            (MHz)
     Low           2403             1.000
     Mid           2440             0.992
     High          2475             1.025




                                                  Page 12                                          Rev. 00


            Compliance Certification Services Inc.
            Report No.: T100617011-RP1   FCC ID: KA2SM22AA1   Date of Issue: September 1, 2010



Test Plot
CH Low




CH Mid




                                           Page 13                                     Rev. 00


          Compliance Certification Services Inc.
          Report No.: T100617011-RP1   FCC ID: KA2SM22AA1   Date of Issue: September 1, 2010



CH High




                                         Page 14                                     Rev. 00


               Compliance Certification Services Inc.
               Report No.: T100617011-RP1       FCC ID: KA2SM22AA1         Date of Issue: September 1, 2010




7.2 BAND EDGES MEASUREMENT
LIMIT
1. In the above emission table, the tighter limit applies at the band edges.
               Frequency                       Field Strength                  Field Strength
                 (MHz)                      (μV/m at 3-meter)               (dBμV/m at 3-meter)
                  30-88                              100                              40
                 88-216                              150                             43.5
                216-960                              200                              46
               Above 960                             500                              54
2. As shown in Section 15.35(b), for frequencies above 1000 MHz, the above field strength limits in
   paragraphs (a) and (b) of this section are based on average limits. However, the peak field
   strength of any emission shall not exceed the maximum permitted average limits specified above
   by more than 20 dB under any condition of modulation. For point-to-point operation under
   paragraph (b) of this section, the peak field strength shall not exceed 2500 millivolts/meter at 3
   meters along the antenna azimuth.
Test Configuration

                                                                  Antenna
                                                                   tower


                     3m                                           Horn
                                                                 antenna
   EUT
                          4m
                                                                 Spectrum
                                                                 analyzer


       Turntable               1m
                   0.8m
                                                                     Pre-amp




TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above the ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
   emission level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out
   the highest emission.
4. Set the spectrum analyzer in the following setting in order to capture the lower and upper
   band-edges of the emission:
    (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
    (b) AVERAGE: RBW=1MHz / VBW=10Hz / Sweep=AUTO
5. Repeat the procedures until all the PEAK and AVERAGE versus POLARIZATION are
   measured.
TEST RESULTS
Refer to attach spectrum analyzer data chart.

                                                  Page 15                                           Rev. 00


            Compliance Certification Services Inc.
            Report No.: T100617011-RP1   FCC ID: KA2SM22AA1          Date of Issue: September 1, 2010




Band Edges (CH Low)

Detector mode: Peak                             Polarity: Vertical




Detector mode: Average                          Polarity: Vertical




                                           Page 16                                            Rev. 00


            Compliance Certification Services Inc.
            Report No.: T100617011-RP1   FCC ID: KA2SM22AA1      Date of Issue: September 1, 2010




Detector mode: Peak                             Polarity: Horizontal




Detector mode: Average                          Polarity: Horizontal




                                           Page 17                                        Rev. 00


            Compliance Certification Services Inc.
            Report No.: T100617011-RP1   FCC ID: KA2SM22AA1          Date of Issue: September 1, 2010




Band Edges (CH High)

Detector mode: Peak                             Polarity: Vertical




Detector mode: Average                          Polarity: Vertical




                                           Page 18                                            Rev. 00


            Compliance Certification Services Inc.
            Report No.: T100617011-RP1   FCC ID: KA2SM22AA1      Date of Issue: September 1, 2010




Detector mode: Peak                             Polarity: Horizontal




Detector mode: Average                          Polarity: Horizontal




                                           Page 19                                        Rev. 00


               Compliance Certification Services Inc.
               Report No.: T100617011-RP1    FCC ID: KA2SM22AA1           Date of Issue: September 1, 2010




7.3 SPURIOUS EMISSION

LIMIT
1. In the section 15.249(a):
  Except as provided in paragraph (b) of this section, the field strength of emissions from intentional
  radiators operated within these frequency bands shall comply with the following:
           Fundamental           Field Strength of Fundamental
                                                               Field Strength of Harmonics
            Frequency                     Field Strength
                                                                           (μV/m)
              (MHz)                          (mV/m)
           902-928 MHz                          50                           500
        2400 - 2483.5 MHz                         50                                 500
         5725 - 5875 MHz                          50                                 500
        24.0 - 24.25 GHz                          250                            2500
2. Except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall not
   exceed the field strength levels specified in the following table:
              Frequency                       Field Strength           Measurement Distance
                 (MHz)                             (μV/m)                         (m)
                  30-88                             100*                            3
                 88-216                            150*                                3
                216-960                            200*                                3
               Above 960                            500                                3
   Remark: Except as provided in paragraph (g), fundamental emissions from intentional
   radiators operating under this Section shall not be located in the frequency bands 54-72
   MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these
   frequency bands is permitted under other sections of this Part, e.g., Sections 15.231 and
   15.241.
3. In the above emission table, the tighter limit applies at the band edges.
              Frequency                       Field Strength                   Field Strength
                (MHz)                       (μV/m at 3-meter)               (dBμV/m at 3-meter)
                 30-88                              100                              40
                 88-216                             150                              43.5
                216-960                             200                               46
               Above 960                            500                               54




                                                Page 20                                            Rev. 00


               Compliance Certification Services Inc.
               Report No.: T100617011-RP1    FCC ID: KA2SM22AA1     Date of Issue: September 1, 2010



Test Configuration
9kHz ~ 30MHz




                             3m
                                                                     Loop antenna
       EUT

                                                                   Spectrum /
                                                                    Receiver


             Turntable                  1m
                            0.8m




   Reference ground plane


30MHz ~ 1GHz

                                                                   Antenna
                                                                    tower


                             3m                                     Bi-log
                                                                   antenna
       EUT
                                   4m
                                                                  Spectrum
                                                                  analyzer


             Turntable                  1m
                            0.8m




   Reference ground plane




                                               Page 21                                       Rev. 00


              Compliance Certification Services Inc.
              Report No.: T100617011-RP1   FCC ID: KA2SM22AA1        Date of Issue: September 1, 2010



Above 1 GHz

                                                            Antenna
                                                             tower


                   3m                                       Horn
                                                           antenna
  EUT
                        4m
                                                            Spectrum
                                                            analyzer


     Turntable               1m
                 0.8m
                                                                Pre-amp




                                             Page 22                                          Rev. 00


               Compliance Certification Services Inc.
               Report No.: T100617011-RP1   FCC ID: KA2SM22AA1      Date of Issue: September 1, 2010




TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission
   level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out
   the highest emissions.
4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
5. And also, each emission was to be maximized by changing the polarization of receiving
   antenna both horizontal and vertical.
6. Set the spectrum analyzer in the following setting as:
   Below 1GHz:
                RBW=100kHz / VBW=300kHz / Sweep=AUTO
   Above 1GHz:
                 (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
                 (b) AVERAGE: RBW=1MHz / VBW=10Hz / Sweep=AUTO
7. Repeat above procedures until the measurements for all frequencies are complete.




                                              Page 23                                        Rev. 00


               Compliance Certification Services Inc.
               Report No.: T100617011-RP1   FCC ID: KA2SM22AA1         Date of Issue: September 1, 2010




Below 1 GHz

Operation Mode: Normal Link                                    Test Date: June 18, 2010
Temperature:        25°C                                       Tested by: Ming Chen
Humidity:           55% RH                                     Polarity:       Ver. / Hor.

                      Detector
Frequency Ant.Pol.               Reading    Correction Factor   Result     Limit 3m          Margin
                       Mode
  (MHz)    (H/V)                 (dBuV)          (dB/m)       (dBuV/m)     (dBuV/m)           (dB)
                      (PK/QP)
  243.40        V       QP        37.78          -11.03        26.75          46.00          -19.25
  296.75        V       QP        36.70           -9.27        27.42          46.00          -18.58
  351.72        V       QP        33.05           -8.02        25.03          46.00          -20.97
  405.07        V       QP        32.96           -6.97        25.99          46.00          -20.01
  647.57        V       QP        32.72           -2.95        29.77          46.00          -16.23
  728.40        V       QP        29.20           -2.13        27.07          46.00          -18.93

  30.00         H       QP        21.49           -1.86        19.63          40.00          -20.37
  191.67        H       QP        32.22          -10.63        21.59          43.50          -21.91
  207.83        H       QP        28.15          -10.53        17.62          43.50          -25.88
  224.00        H       QP        27.90          -11.39        16.51          46.00          -29.49
  351.72        H       QP        25.44           -8.02        17.42          46.00          -28.58
  767.20        H       QP        24.83           -1.65        23.17          46.00          -22.83
Remark:
    1.     No emission found between lowest internal used/generated frequency to 30MHz
           (9kHz~30MHz).
    2.     Radiated emissions measured were made with an instrument using peak/quasi-peak
           detector mode.
    3.     Quasi-peak test would be performed if the peak result were greater than the quasi-peak
           limit or as required by the applicant.
    4.     Measurements above show only up to 6 maximum emissions noted, or would be lesser,
           with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
           margin>20dB from the applicable limit) and considered that's already beyond the
           background noise floor.
    5.     Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m).




                                              Page 24                                           Rev. 00


                    Compliance Certification Services Inc.
                    Report No.: T100617011-RP1      FCC ID: KA2SM22AA1             Date of Issue: September 1, 2010




Above 1 GHz
Operation Mode: Tx / CH Low                                                Test Date: August 30, 2010
Temperature:            25°C                                               Tested by: Ming Chen
Humidity:               55% RH                                             Polarity:       Ver. / Hor.


             Ant.      Peak     AV    Ant. / CL     Result        Peak     AV
  Freq.                                                                          Margin
             Pol      Reading Reading    CF     Peak       AV    Limit    Limit         Remark
 (MHz)                                                                            (dB)
             H/V      (dBuV) (dBuV)     (dB) (dBuV/m) (dBuV/m) (dBuV/m) (dBuV/m)
2403.043      V        94.21   72.92   -2.95    91.26    69.97   114.00   94.00  -24.03  AVG
 1310.00      V        55.87      ---       -9.08      46.79        ---       74.00      54.00      -7.21     Peak
 4808.33      V        57.16     41.84      1.18       58.34      43.02       74.00      54.00     -10.98     AVG
  N/A




2403.043      H        106.5     78.13      -2.95     103.55      75.18      114.00      94.00     -18.82     AVG
 1710.00      H        55.78      ---       -6.82      48.95        ---       74.00      54.00      -5.05     Peak
 4808.33      H        61.96     42.89      1.18       63.14      44.07       74.00      54.00      -9.93     AVG
  N/A




Remark:
        1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency.
        2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using
           peak/average detector mode.
        3. Average test would be performed if the peak result were greater than the average limit or as required by
           the applicant.
        4. Data of measurement within this frequency range shown “ --- ” in the table above means the reading of
           emissions are attenuated more than 20dB below the permissible limits or the field strength is too small
           to be measured.
        5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ”
           remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit)
           and considered that's already beyond the background noise floor.
        6. Margin (dB) = Remark result (dBuV/m) – Average limit (dBuV/m). Peak detector mode and average
           detector mode of the emission shown in Result column.




                                                      Page 25                                                Rev. 00


                    Compliance Certification Services Inc.
                    Report No.: T100617011-RP1      FCC ID: KA2SM22AA1            Date of Issue: September 1, 2010



Operation Mode: Tx / CH Mid                                                Test Date: August 30, 2010
Temperature:            25°C                                               Tested by: Ming Chen
Humidity:               55% RH                                             Polarity:       Ver. / Hor.


             Ant.      Peak     AV    Ant. / CL     Result       Peak      AV
  Freq.                                                                          Margin
             Pol      Reading Reading    CF     Peak       AV    Limit    Limit         Remark
 (MHz)                                                                            (dB)
             H/V      (dBuV) (dBuV)     (dB) (dBuV/m) (dBuV/m) (dBuV/m) (dBuV/m)
2440.000      V        93.26     72.75      -2.84      90.42      69.91      114.00      94.00     -24.09     AVG
 1553.33      V        54.91      ---       -8.27      46.64        ---       74.00      54.00      -7.36     Peak
 4883.33      V        53.57     40.67      1.16       54.72      41.83       74.00      54.00     -12.17     AVG
  N/A




 2440.00      H       101.24     77.78      -2.84      98.40      74.94      114.00      94.00     -19.06     AVG
 1500.00      H        55.69      ---       -8.76      46.93        ---      74.00       54.00      -7.07     Peak
 4883.33      H        61.66     43.39      1.16       62.82      44.55      74.00       54.00      -9.45     AVG
  N/A




Remark:
        1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency.
        2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using
           peak/average detector mode.
        3. Average test would be performed if the peak result were greater than the average limit or as required by
           the applicant.
        4. Data of measurement within this frequency range shown “ --- ” in the table above means the reading of
           emissions are attenuated more than 20dB below the permissible limits or the field strength is too small
           to be measured.
        5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ”
           remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit)
           and considered that's already beyond the background noise floor.
        6. Margin (dB) = Remark result (dBuV/m) – Average limit (dBuV/m). Peak detector mode and average
           detector mode of the emission shown in Result column.




                                                      Page 26                                               Rev. 00


                    Compliance Certification Services Inc.
                    Report No.: T100617011-RP1      FCC ID: KA2SM22AA1            Date of Issue: September 1, 2010



Operation Mode: Tx / CH High                                                Test Date: August 30, 2010
Temperature:             25°C                                               Tested by: Ming Chen
Humidity:                55% RH                                             Polarity:       Ver. / Hor.

             Ant.      Peak     AV    Ant. / CL     Result       Peak      AV
  Freq.                                                                          Margin
             Pol      Reading Reading    CF     Peak       AV    Limit    Limit         Remark
 (MHz)                                                                            (dB)
             H/V      (dBuV) (dBuV)     (dB) (dBuV/m) (dBuV/m) (dBuV/m) (dBuV/m)
2475.000      V        94.96     73.60      -2.74      92.22      70.86      114.00      94.00     -23.14     AVG
 1726.67      V        55.01      ---       -6.67      48.34        ---       74.00      54.00      -5.66     Peak
 4950.00      V        53.72     40.81      1.14       54.86      41.95       74.00      54.00     -12.05     AVG
  N/A




2475.000      H       103.53     79.77      -2.73     100.80      77.04      114.00      94.00     -16.96     AVG
 1470.00      H        55.11      ---       -8.81      46.30        ---      74.00       54.00      -7.70     Peak
 4950.00      H        64.64     43.80      1.14       65.77      44.94      74.00       54.00      -9.06     AVG
 7425.00      H        50.74     36.48      5.37       56.11      41.85       74.00      54.00     -12.15     AVG
  N/A



Remark:
        1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency.
        2. Radiated emissions measured in frequency above 1000MHz were made with an instrument using
           peak/average detector mode.
        3. Average test would be performed if the peak result were greater than the average limit or as required by
           the applicant.
        4. Data of measurement within this frequency range shown “ --- ” in the table above means the reading of
           emissions are attenuated more than 20dB below the permissible limits or the field strength is too small
           to be measured.
        5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ”
           remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit)
           and considered that's already beyond the background noise floor.
        6. Margin (dB) = Remark result (dBuV/m) – Average limit (dBuV/m). Peak detector mode and average
           detector mode of the emission shown in Result column.




                                                      Page 27                                               Rev. 00


              Compliance Certification Services Inc.
              Report No.: T100617011-RP1   FCC ID: KA2SM22AA1         Date of Issue: September 1, 2010



7.4 POWERLINE CONDUCTED EMISSIONS

LIMIT
According to §15.207(a), except as shown in paragraphs (b) and (c) of this section, for an
intentional radiator that is designed to be connected to the public utility (AC) power line, the
radio frequency voltage that is conducted back onto the AC power line on any frequency or
frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the following table,
as measured using a 50 µH/50 ohms line impedance stabilization network (LISN). Compliance
with the provisions of this paragraph shall be based on the measurement of the radio frequency
voltage between each power line and ground at the power terminal. The lower limit applies at the
boundary between the frequency ranges.
                                                             Limits
       Frequency Range                                      (dBμV)
            (MHz)
                                           Quasi-peak                          Average
           0.15 to 0.50                      66 to 56*                        56 to 46*
            0.50 to 5                              56                             46
             5 to 30                               60                             50
* Decreases with the logarithm of the frequency.

Test Configuration

See test photographs attached in Appendix I for the actual connections between EUT and support
equipment.

TEST PROCEDURE
1.   The EUT was placed on a table, which is 0.8m above ground plane.
2.   Maximum procedure was performed on the six highest emissions to ensure EUT
     compliance.
3.   Repeat above procedures until all frequency measured were complete.

TEST RESULTS
Not applicable (Since the EUT is powered by battery)




                                             Page 28                                           Rev. 00