RF Exp_K7SF9K1102V1

FCC ID: K7SF9K1102V1

RF Exposure Info

Download: PDF
FCCID_1424648

                          RF EXPOSURE REPORT


                          REPORT NO.: SA110107E07

                           MODEL NO.: F9K1102V1

                               FCC ID: K7SF9K1102V1



                          ACCORDING: FCC Guidelines for Human Exposure

                                         IEEE C95.1



                    APPLICANT: Belkin International, Inc.

                      ADDRESS: 12045 East Waterfront Drive, Playa Vista, CA
                               90094



                     ISSUED BY: Bureau Veritas Consumer Products Services (H.K.)
                                Ltd., Taoyuan Branch Hsin Chu Laboratory

               LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen,
                            Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan




Report No.: SA110107E07                      1                     Report Format Version 4.0.0


1. RF EXPOSURE LIMIT

LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
  FREQUENCY               ELECTRIC FIELD MAGNETIC FIELD POWER DENSITY     AVERAGE TIME
  RANGE (MHz)             STRENGTH (V/m) STRENGTH (A/m)   (mW/cm2)          (minutes)
                LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
     300-1500                  …              …            F/1500                 30
   1500-100,000                …              …              1.0                  30

F = Frequency in MHz


2. MPE CALCULATION FORMULA
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


3. CLASSIFICATION
The antenna of this product, under normal use condition, is at least 20cm away from the
body of the user. So, this device is classified as Mobile Device.




Report No.: SA110107E07                       2                     Report Format Version 4.0.0


4. CALCULATION RESULT OF MAXIMUM EIRP

 For 15.247(2.4GHz):
 FREQUENCY          CONDUCTED    ANTENNA                   POWER
                                               DISTANCE                      LIMIT
    BAND              POWER        GAIN                    DENSITY
                                                  (cm)                     (mW/cm2)
    (MHz)              (dBm)       (dBi)                  (mW/ cm2)
   2412-2462              27.8     7.3            20        0.650              1.00


 For 15.247(5GHz):
 FREQUENCY          CONDUCTED    ANTENNA                   POWER
                                               DISTANCE                      LIMIT
    BAND              POWER        GAIN                    DENSITY
                                                  (cm)                     (mW/cm2)
    (MHz)              (dBm)       (dBi)                  (mW/ cm2)
   5745-5825              25.8     7.7            20        0.442              1.00



For 15.407(5GHz):
 FREQUENCY          CONDUCTED    ANTENNA                   POWER
                                               DISTANCE                      LIMIT
    BAND              POWER        GAIN                    DENSITY
                                                  (cm)                     (mW/cm2)
    (MHz)              (dBm)       (dBi)                  (mW/ cm2)
   5180-5240              16.2     5.21           20        0.028              1.00




 --- END ---




Report No.: SA110107E07                    3                    Report Format Version 4.0.0