RF Exposure Info (MPE)

FCC ID: K7SF8J237V2

RF Exposure Info

Download: PDF
FCCID_4288298

                                                           RF Exposure Report

                       Report No.: SA190423C25

                            FCC ID: K7SF8J237V2

                       Test Model: F8J237V2

                 Received Date: Apr. 23, 2019

                         Test Date: Apr. 29, 2019

                     Issued Date: May 06, 2019


                         Applicant: Belkin International, Inc.

                          Address: 12045 East Waterfront Drive, Playa Vista, CA 90094


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)
         FCC Registration / 788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by any government agencies.

Report No.: SA190423C25                                              Page No. 1 / 13                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         General Information .............................................................................................................................. 5
    2.1      General Description of EUT ................................................................................................................ 5
3         RF Exposure .......................................................................................................................................... 6
    2.1      Description of Support Units ............................................................................................................... 6
    3.1.1    Configuration of System under Test .................................................................................................... 6
    2.2      Test Setup ........................................................................................................................................... 6
    2.3      Test Instruments .................................................................................................................................. 7
    2.4      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 8
    2.5      Test Point Description ......................................................................................................................... 8
4         Calculation Result of Maximum Conducted Power........................................................................... 9
5         Photographs of the Test Configuration ............................................................................................ 13




Report No.: SA190423C25                                              Page No. 2 / 13                                             Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA190423C25           Original release                                   May 06, 2019




Report No.: SA190423C25                     Page No. 3 / 13       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: PowerHouse™ Charge Dock for Apple Watch + iPhone

              Brand: belkin

        Test Model: F8J237V2

    Sample Status: Engineering sample

          Applicant: Belkin International, Inc.

          Test Date: Apr. 29, 2019

         Standards: FCC Part 1 (Section 1.1307(b), 1.1310)



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                             , Date:          May 06, 2019
                           Celine Chou / Senior Specialist




     Approved by :                                              , Date:          May 06, 2019
                           Bruce Chen / Project Engineer




Report No.: SA190423C25                       Page No. 4 / 13                         Report Format Version: 6.1.1


2     General Information
2.1    General Description of EUT

 Product                        PowerHouse™ Charge Dock for Apple Watch + iPhone
 Test Model                     F8J237V2
 Sample Status                  Engineering sample
 Power Supply Rating            12Vdc (Adapter)
 Modulation Type                FSK
 Operating Frequency            326.5 kHz
 Antenna Type                   Coil antenna
 Field Strength                 50.5dBuV/m
 Dimension for Apple watch
                                7.95cm2 (diameter = 31.82mm)
 inductive coil
 Accessory Device               Adapter
 Data Cable Supplied            NA
 Maximum Power Output for
                               Less than 5W
 Apple watch inductive coil
Note:
1. The EUT uses following adapter.
 Brand                         HOIOTO
 Model                         ADS-25SGP-12 12019E
 Input Power                   100-240Vac, 50/60Hz, 0.7A Max
 Output Power                  12Vdc, 1.6A
 Power Line                    1.5m non-shielded DC cable without core attached on adapter
2. The EUT has a wireless inductive charging coil for charging Apple watch and a USB board to charge
   iPhone.
3. After the evaluation of the metal and plastic band on Apple Watch, the metal band was found to be the
   worst case test mode and therefore was been presented in the test report.




Report No.: SA190423C25                        Page No. 5 / 13                      Report Format Version: 6.1.1


3        RF Exposure
2.1       Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
    ID       Product          Brand      Model No.             Serial No.      FCC ID              Remarks
    A.     Apple Watch       APPLE        A1554                    NA           NA        -


3.1.1      Configuration of System under Test
Charging Mode


                                                                 Apple Watch
                                                                     (A)

               Adapter (EUT)                               EUT




Standby Mode




               Adapter (EUT)                               EUT




2.2       Test Setup




                                                              15/20 cm




                                                                                   EUT

                         Field Probe




Note: Measurements were made from all sides and the top of the primary/client pair, with the 15/20cm
     measured from the center of the probe(s) to the edge of the device. The highest emission level was
     recorded.



Report No.: SA190423C25                              Page No. 6 / 13                     Report Format Version: 6.1.1


2.3      Test Instruments

       Description          Brand    Model No.     Frequency Range Calibrated Date         Calibrated Until
  Broadband Field
                          NARDA       NBM-550                  -        Mar. 28, 2018       Mar. 27, 2020
       Meter
   Magnetic Field
                          NARDA       ELT-400          1 – 400kHz       Apr. 12, 2018       Apr. 11, 2020
      Meter
  Magnetic Probe          NARDA       HF 3061       300kHz – 30MHz      Apr. 16, 2018       Apr. 15, 2020
  Magnetic Probe          NARDA       HF-0191        27 – 1000MHz       Apr. 17, 2018       Apr. 16, 2020
  Broadband Field
                          NARDA       NBM-550                  -        Mar. 28, 2018       Mar. 27, 2020
       Meter
   Magnetic Field
                          NARDA      2300/90.10      1Hz – 400kHz       Apr. 12, 2018       Apr. 11, 2020
      Probe
      E-Field Probe       NARDA       EF 0391       100kHz – 3GHz       Apr. 16, 2018       Apr. 15, 2020
      E-Field Probe       NARDA       EF6091       100MHz – 60GHz         Apr. 17, 2018     Apr. 16, 2020
 Note: 1. The calibration interval of the above test instruments is 12/24 months and the
           calibrations are traceable to NML/ROC and NIST/USA.
       2. The test was performed in HwaYa RF Chamber




Report No.: SA190423C25                      Page No. 7 / 13                         Report Format Version: 6.1.1


2.4     Limits for Maximum Permissible Exposure (MPE)
§ 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of
  human exposure to radiofrequency(RF) radiation as specified in § 1.1307(b), except in the case of portable
  devices which shall be evaluated according to the provisions of § 2.1093 of this chapter.




680106 D01 RF Exposure Wireless Charging Apps v03
The aggregate H-fields strengths at 15 cm surrounding the device and 20cm above the top surface from all
simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

2.5     Test Point Description



                          Z-axis (Above)
                                       Top




      Left                                       Right




                 Bottom




Report No.: SA190423C25                      Page No. 8 / 13                        Report Format Version: 6.1.1


4    Calculation Result of Maximum Conducted Power
Charging Mode with watch, battery 10% Charge
                                                                                                E-Field
                                   E-Field Measurement (15cm)                                Measurement
                                                                                                (20cm)
Frequency                                                                                        Z-axis
                   EUT Side              Left             Right       Top        Bottom
  (kHz)                                                                                        (Above)
    326.5      Max E-field (V/m)       0.8200            0.7500      0.8600      0.8100          0.5800

    326.5         Limit (V/m)            614               614        614         614              614

    326.5        Margin (V/m)         -613.1800        -613.2500    -613.1400   -613.1900      -613.4200

    326.5      50 % Limit (V/m)          307               307        307         307              307

    326.5     50 % Margin (V/m)       -306.1800        -306.2500    -306.1400   -306.1900      -306.4200

                                                                                               H-Field
                                   H-Field Measurement (15cm)                                Measurement
                                                                                                (20cm)
Frequency                                                                                        Z-axis
                   EUT Side              Left             Right       Top        Bottom
  (kHz)                                                                                        (Above)
    326.5       Max H-field (uT)       0.0650            0.0700      0.0660      0.0630          0.0650

    326.5      Max H-field (A/m)       0.0520            0.0560      0.0528      0.0504          0.0520

    326.5         Limit (A/m)            1.63              1.63       1.63        1.63             1.63

    326.5        Margin (A/m)          -1.5780           -1.5740     -1.5772     -1.5796         -1.5780

    326.5      50 % Limit (A/m)         0.815             0.815       0.815       0.815           0.815

    326.5     50 % Margin (A/m)        -0.7630           -0.7590     -0.7622     -0.7646         -0.7630
Measurements were made from all sides and the top of the primary/client pair, with the 15/20cm measured
from the center of the probe(s) to the edge of the device. The highest emission level was recorded.




Report No.: SA190423C25                           Page No. 9 / 13                  Report Format Version: 6.1.1


Charging Mode with watch, battery 50% Charge
                                                                                                 E-Field
                                   E-Field Measurement (15cm)                                 Measurement
                                                                                                 (20cm)
Frequency                                                                                         Z-axis
                   EUT Side              Left             Right        Top        Bottom
  (kHz)                                                                                         (Above)
   326.5       Max E-field (V/m)       0.9100            0.7900       0.9900      0.9400          0.6100

   326.5          Limit (V/m)            614               614         614         614              614

   326.5         Margin (V/m)         -613.0900        -613.2100     -613.0100   -613.0600      -613.3900

   326.5       50 % Limit (V/m)          307               307         307         307              307

   326.5      50 % Margin (V/m)       -306.0900        -306.2100     -306.0100   -306.0600      -306.3900

                                                                                                H-Field
                                   H-Field Measurement (15cm)                                 Measurement
                                                                                                 (20cm)
Frequency                                                                                         Z-axis
                   EUT Side              Left             Right        Top        Bottom
  (kHz)                                                                                         (Above)
   326.5        Max H-field (uT)       0.0710            0.0730       0.0670      0.0650          0.0660

   326.5       Max H-field (A/m)       0.0568            0.0584       0.0536      0.0520          0.0528

   326.5          Limit (A/m)            1.63              1.63        1.63        1.63             1.63

   326.5         Margin (A/m)          -1.5732           -1.5716      -1.5764     -1.5780         -1.5772

   326.5       50 % Limit (A/m)         0.815             0.815        0.815       0.815           0.815

   326.5      50 % Margin (A/m)        -0.7582           -0.7566      -0.7614     -0.7630         -0.7622
Measurements were made from all sides and the top of the primary/client pair, with the 15/20cm measured
from the center of the probe(s) to the edge of the device. The highest emission level was recorded.




Report No.: SA190423C25                           Page No. 10 / 13                  Report Format Version: 6.1.1


Charging Mode with watch, battery 90% Charge
                                                                                                E-Field
                                   E-Field Measurement (15cm)                                Measurement
                                                                                                (20cm)
Frequency                                                                                        Z-axis
                   EUT Side              Left            Right        Top        Bottom
  (kHz)                                                                                        (Above)
   326.5       Max E-field (V/m)       1.0500           0.9100       1.0900      1.0700          0.7500

   326.5          Limit (V/m)            614              614         614         614              614

   326.5         Margin (V/m)         -612.9500       -613.0900     -612.9100   -612.9300      -613.2500

   326.5       50 % Limit (V/m)          307              307         307         307              307

   326.5      50 % Margin (V/m)       -305.9500       -306.0900     -305.9100   -305.9300      -306.2500

                                                                                               H-Field
                                   H-Field Measurement (15cm)                                Measurement
                                                                                                (20cm)
Frequency                                                                                        Z-axis
                   EUT Side              Left            Right        Top        Bottom
  (kHz)                                                                                        (Above)
   326.5        Max H-field (uT)       0.0730           0.0760       0.0690      0.0660          0.0680

   326.5       Max H-field (A/m)       0.0584           0.0608       0.0552      0.0528          0.0544

   326.5          Limit (A/m)            1.63             1.63        1.63        1.63             1.63

   326.5         Margin (A/m)          -1.5716          -1.5692      -1.5748     -1.5772         -1.5756

   326.5       50 % Limit (A/m)         0.815            0.815        0.815       0.815           0.815

   326.5      50 % Margin (A/m)        -0.7566          -0.7542      -0.7598     -0.7622         -0.7606
Measurements were made from all sides and the top of the primary/client pair, with the 15/20cm measured
from the center of the probe(s) to the edge of the device. The highest emission level was recorded.




Report No.: SA190423C25                          Page No. 11 / 13                  Report Format Version: 6.1.1


Standby Mode
                                                                                                 E-Field
                                   E-Field Measurement (15cm)                                 Measurement
                                                                                                 (20cm)
Frequency                                                                                         Z-axis
                   EUT Side              Left             Right        Top        Bottom
  (kHz)                                                                                         (Above)
   326.5       Max E-field (V/m)       0.6900            0.6200       0.7400      0.7600          0.5900

   326.5          Limit (V/m)            614               614         614         614              614

   326.5         Margin (V/m)         -613.3100        -613.3800     -613.2600   -613.2400      -613.4100

   326.5       50 % Limit (V/m)          307               307         307         307              307

   326.5      50 % Margin (V/m)       -306.3100        -306.3800     -306.2600   -306.2400      -306.4100

                                                                                                H-Field
                                   H-Field Measurement (15cm)                                 Measurement
                                                                                                 (20cm)
Frequency                                                                                         Z-axis
                   EUT Side              Left             Right        Top        Bottom
  (kHz)                                                                                         (Above)
   326.5        Max H-field (uT)       0.0610            0.0640       0.0650      0.0620          0.0640

   326.5       Max H-field (A/m)       0.0488            0.0512       0.0520      0.0496          0.0512

   326.5          Limit (A/m)            1.63              1.63        1.63        1.63             1.63

   326.5         Margin (A/m)          -1.5812           -1.5788      -1.5780     -1.5804         -1.5788

   326.5       50 % Limit (A/m)         0.815             0.815        0.815       0.815           0.815

   326.5      50 % Margin (A/m)        -0.7662           -0.7638      -0.7630     -0.7654         -0.7638
Measurements were made from all sides and the top of the primary/client pair, with the 15/20cm measured
from the center of the probe(s) to the edge of the device. The highest emission level was recorded.




Report No.: SA190423C25                           Page No. 12 / 13                  Report Format Version: 6.1.1


5    Photographs of the Test Configuration
Please refer to the attached file (Test Setup Photo).




--- END ---




Report No.: SA190423C25                        Page No. 13 / 13   Report Format Version: 6.1.1



Document Created: 2019-05-24 18:35:38
Document Modified: 2019-05-24 18:35:38

© 2025 FCC.report