Test Report

FCC ID: K7SF8J233

Test Report

Download: PDF
FCCID_4143479

                                                               FCC Test Report

                       Report No.: RF181018C34

                            FCC ID: K7SF8J233

                       Test Model: F8J233

                 Received Date: Oct. 18, 2018

                         Test Date: Oct. 30, 2018

                     Issued Date: Nov. 21, 2018


                         Applicant: Belkin International, Inc.

                          Address: 12045 E. Waterfront Drive, Playa Vista, CA 90094 USA


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)
         FCC Registration / 788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: RF181018C34                                              Page No. 1 / 24                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         Summary of Test Results ..................................................................................................................... 5
    2.1      Measurement Uncertainty ................................................................................................................... 5
    2.2      Modification Record ............................................................................................................................ 5
3         General Information .............................................................................................................................. 6
    3.1      General Description of EUT ................................................................................................................ 6
    3.2      Description of Test Modes ................................................................................................................... 6
    3.2.1    Test Mode Applicability and Tested Channel Detail ............................................................................. 7
    3.3      Description of Support Units ............................................................................................................... 8
    3.3.1    Configuration of System under Test .................................................................................................... 8
    3.4      General Description of Applied Standards .......................................................................................... 8
4         Test Types and Results ........................................................................................................................ 9
    4.1      Radiated Emission and Bandedge Measurement............................................................................... 9
    4.1.1    Limits of Radiated Emission and Bandedge Measurement ................................................................ 9
    4.1.2    Test Instruments ................................................................................................................................ 10
    4.1.3    Test Procedures.................................................................................................................................. 11
    4.1.4    Deviation from Test Standard ............................................................................................................. 11
    4.1.5    Test Set Up ........................................................................................................................................ 12
    4.1.6    EUT Operating Conditions................................................................................................................. 12
    4.1.7    Test Results ....................................................................................................................................... 13
    4.2      Conducted Emission Measurement .................................................................................................. 19
    4.2.1    Limits of Conducted Emission Measurement .................................................................................... 19
    4.2.2    Test Instruments ................................................................................................................................ 19
    4.2.3    Test Procedures................................................................................................................................. 20
    4.2.4    Deviation from Test Standard ............................................................................................................ 20
    4.2.5    Test Setup .......................................................................................................................................... 20
    4.2.6    EUT Operating Conditions................................................................................................................. 20
    4.2.7    Test Results ....................................................................................................................................... 21
5         Pictures of Test Arrangements .......................................................................................................... 23
Appendix – Information on the Testing Laboratories ................................................................................ 24




Report No.: RF181018C34                                              Page No. 2 / 24                                             Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
RF181018C34           Original release                                   Nov. 21, 2018




Report No.: RF181018C34                     Page No. 3 / 24       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: BOOST↑CHARGE™

              Brand: belkin

         Model No.: F8J233

    Sample Status: Engineering sample

          Applicant: Belkin International, Inc.

          Test Date: Oct. 30, 2018

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.209)
                          ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                               , Date:        Nov. 21, 2018
                             Celine Chou / Senior Specialist




     Approved by :                                                , Date:        Nov. 21, 2018
                             Bruce Chen / Project Engineer




Report No.: RF181018C34                         Page No. 4 / 24                       Report Format Version: 6.1.1


2     Summary of Test Results

                             47 CFR FCC Part 15, Subpart C (Section 15.209)
       FCC
                              Test Item                   Result                  Remarks
      Clause
                                                                     Meet the requirement of limit.
      15.207      AC Power Conducted Emission              Pass      Minimum passing margin is
                                                                     -15.79dB at 0.16569MHz.
                                                                     Meet the requirement of limit.
      15.209      Radiated Emission Test                   Pass      Minimum passing margin is
                                                                     -11.1dB at 259.38MHz and 35.83MHz.

2.1    Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
EUT as specified in CISPR 16-4-2:
                                                                                  Expanded Uncertainty
                   Measurement                                 Frequency
                                                                                       (k=2) (±)
        Conducted Emissions at mains ports               150kHz ~ 30MHz                 2.94 dB
                                                         30MHz ~ 200MHz                 3.86 dB
         Radiated Emissions up to 1 GHz
                                                        200MHz ~ 1000MHz                3.87 dB


2.2    Modification Record
There were no modifications required for compliance.




Report No.: RF181018C34                      Page No. 5 / 24                        Report Format Version: 6.1.1


3     General Information
3.1    General Description of EUT

 Product                            BOOST↑CHARGE™
 Test Model                         F8J233
 Sample Status                      Engineering sample
                                    5Vdc (Adapter)
 Power Supply Rating
                                    3.83Vdc (Battery)
 Modulation Type                    FSK
 Operating Frequency                326.5 kHz
 Antenna Type                       Coil antenna
 Field Strength                     49.5dBuV/m
 Dimension for Apple watch
                                    7.95cm2 (diameter = 31.82mm)
 inductive coil
 Accessory Device                   NA
 Data Cable Supplied                0.17m shielded USB cable without core
 Maximum Power Output for
                                Less than 5W
 Apple watch inductive coil
Note:
1. The EUT uses following battery.
 Brand                          Dongguan Amperex Technology Limited
 Model                          B03543
 Power Rating                   3.83Vdc, 2200mAh
2. The EUT has a wireless inductive charging coil for charging Apple watch.

3.2    Description of Test Modes
1 channel is provided to this EUT
             Channel                                                 Freq. (kHz)
                  1                                                    326.5




Report No.: RF181018C34                            Page No. 6 / 24                 Report Format Version: 6.1.1


3.2.1       Test Mode Applicability and Tested Channel Detail
    EUT                           APPLICABLE TO
 CONFIGURE                                                                                DESCRIPTION
   MODE                     RE<1G                PLC
        A                     √                    √         EUT wireless charging to Apple watch + AC adapter
        B                     √                    -         Standby Mode + AC adapter
Where        RE<1G: Radiated Emission below 1GHz             PLC: Power Line Conducted Emission


Note: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on X-plane.


Radiated Emission Test (Below 1GHz):
     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
             EUT Configure Mode                          Available Channel                          Tested Channel
                     A, B                                         1                                          1


Power Line Conducted Emission Test:
    Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
     available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
             EUT Configure Mode                          Available Channel                          Tested Channel
                      A                                           1                                          1


Test Condition:
     Applicable To                Environmental Conditions                 Input Power                       Tested by
                                                                           120Vac, 60Hz
        RE<1G                        25 deg. C, 65% RH                                                      Willy Cheng
                                                                             3.83Vdc
            PLC                      22 deg. C, 67% RH                     120Vac, 60Hz                     Willy Cheng




Report No.: RF181018C34                                  Page No. 7 / 24                                Report Format Version: 6.1.1


3.3     Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
 ID        Product          Brand      Model No.             Serial No.        FCC ID               Remarks
 A.        Adapter          Apple       A1385                    NA              NA        -
 B.      Apple Watch        Apple       A1889             FH7V1006J97R        BCG-A1889    Provided by client


3.3.1    Configuration of System under Test
Test Mode A

                                                                Apple Watch
                                                                    (B)


               Adapter (A)                                EUT




Test Mode B




              Adapter (A)                                EUT




3.4     General Description of Applied Standards
The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:

FCC Part 15, Subpart C (15.209)
ANSI C63.10-2013

All test items have been performed and recorded as per the above standards.




Report No.: RF181018C34                            Page No. 8 / 24                        Report Format Version: 6.1.1


4       Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement
FOR FREQUENCY BELOW 30MHz

        Frequency                Field Strength (dBuV/m)                   Measurement Distance
          (MHz)               uV/m                      dBuV/m                   (meters)

      0.009 – 0.490       2400 / F (kHz)             48.52-13.80                   300

      0.490 – 1.705       24000 / F (kHz)            33.80-22.97                    30

      1.705 – 30.0               30                      29.54                      30

FOR FREQUENCY BETWEEN 30-1000MHz

            Frequency                         Class A (at 10m)                  Class B (at 3m)
              (MHz)                        uV/m                  dBuV/m     uV/m               dBuV/m

               30-88                        90                      39.1     100                 40.0

              88-216                        150                     43.5     150                 43.5

              216-960                       210                     46.4     200                 46.0

            Above 960                       300                     49.5     500                 54.0




Report No.: RF181018C34                           Page No. 9 / 24                  Report Format Version: 6.1.1


4.1.2   Test Instruments
  Description & Manufacturer         Model No.                    Serial No.     Cal. Date          Cal. Due
Test Receiver
                                       ESIB7                       100187      May 29, 2018      May 28, 2019
ROHDE & SCHWARZ
Spectrum Analyzer
                                      FSP40                        100041      Dec. 12, 2017 Dec. 11, 2018
ROHDE & SCHWARZ
BILOG Antenna
                                    VULB9168                      9168-171     Dec. 11, 2017 Dec. 10, 2018
SCHWARZBECK
HORN Antenna
                                       9120D                         209       Dec. 13, 2017 Dec. 12, 2018
SCHWARZBECK
HORN Antenna
                                    BBHA 9170               BBHA9170241        Dec. 01, 2017 Nov. 30, 2018
SCHWARZBECK
Loop Antenna
                                     HLA 6121                      45745       Jun. 14, 2018     Jun. 13, 2019
TESEQ
Preamplifier
Agilent                                8447D                 2944A10738        Aug. 21, 2018 Aug. 20, 2019
(Below 1GHz)
Preamplifier
Agilent                                8449B                 3008A02465        Apr. 03, 2018     Apr. 02, 2019
(Above 1GHz)
RF signal cable                                             Cable-CH3-03
                                  SUCOFLEX 104                                 Aug. 21, 2018 Aug. 20, 2019
HUBER+SUHNER                                                 (223653/4)
RF signal cable                    SUCOFLEX
                                                            Cable-CH3-03
HUBER+SUHNER&                   104&EMC104-SM-S                                Aug. 21, 2018 Aug. 20, 2019
                                                          (309224+170907)
EMCI                                 M-8000
Software                          ADT_Radiated_
                                                                     NA             NA                 NA
BV ADT                             V7.6.15.9.5
Antenna Tower
                                     MA 4000                       013303           NA                 NA
inn-co GmbH
Antenna Tower Controller
                                       AT100                 AT93021702             NA                 NA
BV ADT
Turn Table
                                       TT100                 TT93021702             NA                 NA
BV ADT
Turn Table Controller
                                      SC100                  SC93021702             NA                 NA
BV ADT
Boresight Antenna Fixture             FBA-01                  FBA-SIP01             NA                 NA

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Chamber 3.
      3. The horn antenna and preamplifier (model: 8449B) are used only for the measurement of emission
         frequency above 1GHz if tested.
      4. The FCC Designation Number is TW0003. The number will be varied with the Lab location and
         scope as attached.
      5. The IC Site Registration No. is 7450F-3.




Report No.: RF181018C34                        Page No. 10 / 24                        Report Format Version: 6.1.1


4.1.3   Test Procedures
For Radiated emission below 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
    room. The table was rotated 360 degrees to determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
     measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
     from 0 degrees to 360 degrees to find the maximum reading.
e.   The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with Maximum
     Hold Mode.
Note:
1.   The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
     below 30MHz.

For Radiated emission above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for below 1GHz) / 1.5 meters (for above
    1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
    determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   The height of antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
     to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
     find the maximum reading.
e.   The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
     hold mode when the test frequency is below 1 GHz.
f.   The test-receiver system was set to peak and average detect function and specified bandwidth with
     maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
     average limit, measurement with the average detector is unnecessary.
Note:
1.   The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
     Quasi-peak detection (QP) at frequency below 1GHz.
2.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
     for Peak detection (PK) at frequency above 1GHz.
3.   The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is ≥ 1/T
     (Duty cycle < 98%) or 10Hz (Duty cycle ≥ 98%) for Average detection (AV) at frequency above 1GHz.
4.   All modes of operation were investigated and the worst-case emissions are reported.


4.1.4   Deviation from Test Standard

No deviation.



Report No.: RF181018C34                        Page No. 11 / 24                        Report Format Version: 6.1.1


4.1.5   Test Set Up
For Radiated emission below 30MHz

                EUT&                          3m
                                                                          Loop antenna
               Support Units

                                         Turn Table

                 80cm


                                              Ground Plane

                                           Test Receiver




For Radiated emission 30MHz to 1GHz
                                                               Ant. Tower
                                                                                      1-4m
                                                                                      Variable
              EUT&
                                                 3m
                                                 10m
              Support Units

                                         Turn Table

                 80cm


                                              Ground Plane

                                              Test Receiver




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions
Test Mode A
a. Put the Apple watch on the EUT (wireless charging) during the test.

Test Mode B
a. Set the EUT under standby mode during the test.




Report No.: RF181018C34                         Page No. 12 / 24                           Report Format Version: 6.1.1


4.1.7   Test Results
Below 30MHz Data:
EUT Wireless Charging to Apple Watch Mode + AC adapter
Channel                          TX Channel 1
                                                            Detector Function          Quasi-Peak
Frequency Range                  9 kHz ~ 30 MHz

Test Mode                        A

                  ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA OPEN AT 3m
                     Emission                                    Antenna      Table         Raw          Correction
          Freq.                          Limit     Margin
No.                    Level                                      Height     Angle          Value         Factor
         (MHz)                         (dBuV/m)     (dB)
                     (dBuV/m)                                      (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.3265           49.5           97.3       -47.8            1.0        225          29.4           20.1
 2       3.229            40.3           69.5       -29.2            1.0        118          20.7           19.6
 3       4.623            35.0           69.5       -34.5            1.0        205          14.7           20.3
 4      13.034            35.8           69.5       -33.7            1.0        103          14.0           21.8
 5      17.311            37.7           69.5       -31.8            1.0        279          15.9           21.8
 6      23.800            39.6           69.5       -29.9            1.0        246          17.6           22.0
 7      25.098            36.8           69.5       -32.7            1.0        100          14.8           22.0
                  ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA CLOSE AT 3m
                     Emission                                    Antenna      Table         Raw          Correction
          Freq.                          Limit     Margin
No.                    Level                                      Height     Angle          Value         Factor
         (MHz)                         (dBuV/m)     (dB)
                     (dBuV/m)                                      (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.3265           45.9           97.3       -51.4            1.0        318          25.8           20.1
 2       2.460            34.0           69.5       -35.5            1.0        297          14.3           19.7
 3       9.141            35.5           69.5       -34.0            1.0        12           13.9           21.6
 4      14.091            36.1           69.5       -33.4            1.0        281          14.3           21.8
 5      15.677            36.5           69.5       -33.0            1.0        337          14.7           21.8
 6      21.637            35.3           69.5       -34.2            1.0         9           13.4           21.9
 7      24.473            35.4           69.5       -34.1            1.0        348          13.4           22.0
        ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA GROUND-PARALLEL AT 3m
                     Emission                                    Antenna      Table         Raw          Correction
          Freq.                          Limit     Margin
No.                    Level                                      Height     Angle          Value         Factor
         (MHz)                         (dBuV/m)     (dB)
                     (dBuV/m)                                      (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.3265           43.7           97.3       -53.6            1.0        209          23.6           20.1
 2       3.229            42.6           69.5       -26.9            1.0        205          23.0           19.6
 3      15.581            38.8           69.5       -30.7            1.0        126          17.0           21.8
 4      19.474            43.3           69.5       -26.2            1.0        325          21.5           21.8
 5      23.367            43.5           69.5       -26.0            1.0        86           21.5           22.0
 6      23.800            43.4           69.5       -26.1            1.0        185          21.4           22.0
 7      25.098            40.9           69.5       -28.6            1.0        69           18.9           22.0


Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40


Report No.: RF181018C34                           Page No. 13 / 24                         Report Format Version: 6.1.1


Standby Mode + AC adapter
Channel                          TX Channel 1
                                                            Detector Function          Quasi-Peak
Frequency Range                  9 kHz ~ 30 MHz

Test Mode                        B

                  ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA OPEN AT 3m
                     Emission                                    Antenna      Table         Raw          Correction
          Freq.                          Limit     Margin
No.                    Level                                      Height     Angle          Value         Factor
         (MHz)                         (dBuV/m)     (dB)
                     (dBuV/m)                                      (m)      (Degree)       (dBuV)         (dB/m)
 1       0.653            39.8           71.3       -31.5            1.0        167          19.6           20.2
 2       3.229            47.5           69.5       -22.0            1.0        212          27.9           19.6
 3      13.322            43.0           69.5       -26.5            1.0        54           21.2           21.8
 4      18.369            44.5           69.5       -25.0            1.0        199          22.7           21.8
 5      22.214            48.3           69.5       -21.2            1.0        164          26.4           21.9
 6      23.800            47.4           69.5       -22.1            1.0        103          25.4           22.0
                  ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA CLOSE AT 3m
                     Emission                                    Antenna      Table         Raw          Correction
          Freq.                          Limit     Margin
No.                    Level                                      Height     Angle          Value         Factor
         (MHz)                         (dBuV/m)     (dB)
                     (dBuV/m)                                      (m)      (Degree)       (dBuV)         (dB/m)
 1       0.653            41.7           71.3       -29.6            1.0        347          21.5           20.2
 2       3.229            45.1           69.5       -24.4            1.0        198          25.5           19.6
 3      15.581            43.8           69.5       -25.7            1.0        277          22.0           21.8
 4      17.792            43.9           69.5       -25.6            1.0         4           22.1           21.8
 5      23.367            48.4           69.5       -21.1            1.0        197          26.4           22.0
 6      23.800            44.7           69.5       -24.8            1.0        159          22.7           22.0
        ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA GROUND-PARALLEL AT 3m
                     Emission                                    Antenna      Table         Raw          Correction
          Freq.                          Limit     Margin
No.                    Level                                      Height     Angle          Value         Factor
         (MHz)                         (dBuV/m)     (dB)
                     (dBuV/m)                                      (m)      (Degree)       (dBuV)         (dB/m)
 1       0.653            39.3           71.3       -32.0            1.0        138          19.1           20.2
 2       3.229            50.6           69.5       -18.9            1.0        175          31.0           19.6
 3      15.581            45.7           69.5       -23.8            1.0        134          23.9           21.8
 4      17.792            46.5           69.5       -23.0            1.0        73           24.7           21.8
 5      19.474            47.0           69.5       -22.5            1.0         4           25.2           21.8
 6      21.637            45.1           69.5       -24.4            1.0        30           23.2           21.9


Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40




Report No.: RF181018C34                           Page No. 14 / 24                         Report Format Version: 6.1.1


Below 1GHz Data:
EUT Wireless Charging to Apple Watch Mode + AC adapter
Channel                   TX Channel 1
                                                           Detector Function          Quasi-Peak
Frequency Range           30MHz ~ 1GHz

Test Mode                 A

                                Antenna Polarity & Test Distance: Horizontal At 3m
                     Emission                                  Antenna       Table         Raw          Correction
          Freq.                       Limit       Margin
No.                    Level                                    Height      Angle          Value         Factor
         (MHz)                      (dBuV/m)       (dB)
                     (dBuV/m)                                     (m)      (Degree)       (dBuV)         (dB/m)
 1      37.78         21.2 QP         40.0        -18.8         2.00 H        178          31.6           -10.4
 2      84.43         20.2 QP         40.0        -19.8         2.00 H        119          34.5           -14.3
 3      134.97        19.1 QP         43.5        -24.4         2.00 H         15          29.2           -10.1
 4      552.91        26.5 QP         46.0        -19.5         1.00 H        14           29.1            -2.6
 5      619.00        28.1 QP         46.0        -17.9         2.00 H        309          28.8            -0.7
 6      896.97        32.8 QP         46.0        -13.2         1.50 H        99           28.8             4.0


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit.
           4. Margin value = Emission Level – Limit value




Report No.: RF181018C34                         Page No. 15 / 24                          Report Format Version: 6.1.1


Channel                   TX Channel 1
                                                          Detector Function          Quasi-Peak
Frequency Range           30MHz ~ 1GHz

Test Mode                 A


                                Antenna Polarity & Test Distance: Vertical At 3m
                     Emission                                 Antenna       Table         Raw          Correction
          Freq.                      Limit       Margin
No.                    Level                                   Height      Angle          Value         Factor
         (MHz)                     (dBuV/m)       (dB)
                     (dBuV/m)                                    (m)      (Degree)       (dBuV)         (dB/m)
 1      39.72         23.9 QP        40.0        -16.1         1.00 V         4           33.9           -10.0
 2      70.82         18.7 QP        40.0        -21.3         1.00 V        262          30.2           -11.5
 3      148.67        31.5 QP        43.5        -12.0         1.49 V        352          40.5            -9.0
 4      430.44        23.7 QP        46.0        -22.3         1.49 V         56          28.3            -4.6
 5      506.25        26.8 QP        46.0        -19.2         1.49 V         77          30.2            -3.4
 6      832.83        30.8 QP        46.0        -15.2         1.99 V        169          28.0            2.8


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit.
           4. Margin value = Emission Level – Limit value




Report No.: RF181018C34                        Page No. 16 / 24                          Report Format Version: 6.1.1


Standby Mode + AC adapter
Channel                   TX Channel 1
                                                           Detector Function          Quasi-Peak
Frequency Range           30MHz ~ 1GHz

Test Mode                 B

                                Antenna Polarity & Test Distance: Horizontal At 3m
                     Emission                                  Antenna       Table         Raw          Correction
          Freq.                       Limit       Margin
No.                    Level                                    Height      Angle          Value         Factor
         (MHz)                      (dBuV/m)       (dB)
                     (dBuV/m)                                     (m)      (Degree)       (dBuV)         (dB/m)
 1      30.56         25.0 QP         40.0        -15.0         1.00 H        13           36.1           -11.1
 2      56.69         24.2 QP         40.0        -15.8         2.00 H        13           33.8            -9.6
 3      84.43         20.0 QP         40.0        -20.0         2.00 H        282          34.3           -14.3
 4      133.03        19.3 QP         43.5        -24.2         2.00 H         4           29.7           -10.4
 5      309.92        20.9 QP         46.0        -25.1         1.00 H        189          27.9            -7.0
 6      628.72        28.0 QP         46.0        -18.0         1.50 H        336          28.5            -0.5


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit.
           4. Margin value = Emission Level – Limit value




Report No.: RF181018C34                         Page No. 17 / 24                          Report Format Version: 6.1.1


Channel                   TX Channel 1
                                                          Detector Function          Quasi-Peak
Frequency Range           30MHz ~ 1GHz

Test Mode                 B


                                Antenna Polarity & Test Distance: Vertical At 3m
                     Emission                                 Antenna       Table         Raw          Correction
          Freq.                      Limit       Margin
No.                    Level                                   Height      Angle          Value         Factor
         (MHz)                     (dBuV/m)       (dB)
                     (dBuV/m)                                    (m)      (Degree)       (dBuV)         (dB/m)
 1      30.00         28.7 QP        40.0        -11.3         1.00 V        343          39.8           -11.1
 2      39.72         24.4 QP        40.0        -15.6         1.00 V        249          34.4           -10.0
 3      133.03        20.4 QP        43.5        -23.1         1.00 V        14           30.8           -10.4
 4      584.01        26.5 QP        46.0        -19.5         1.50 V        310          28.0            -1.5
 5      677.31        28.6 QP        46.0        -17.4         2.00 V         6           28.5            0.1
 6      805.61        29.7 QP        46.0        -16.3         1.50 V        318          27.1            2.6


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit.
           4. Margin value = Emission Level – Limit value




Report No.: RF181018C34                        Page No. 18 / 24                          Report Format Version: 6.1.1


4.2     Conducted Emission Measurement
4.2.1    Limits of Conducted Emission Measurement
                                                            Conducted Limit (dBuV)
        Frequency (MHz)
                                                Quasi-peak                              Average
           0.15 - 0.5                              66 - 56                               56 - 46
           0.50 - 5.0                                56                                     46
           5.0 - 30.0                                60                                     50
Note: 1. The lower limit shall apply at the transition frequencies.
      2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.

4.2.2    Test Instruments

   Description & Manufacturer           Model No.                 Serial No.     Cal. Date          Cal. Due
Test Receiver
                                           ESCI                    100613      Nov. 23, 2017 Nov. 22, 2018
ROHDE & SCHWARZ
RF signal cable
                                          5D-FB              Cable-cond1-01    Sep. 05, 2018 Sep. 04, 2019
Woken
LISN
ROHDE & SCHWARZ                          ENV216                    101826      Feb. 26, 2018 Feb. 25, 2019
(EUT)
LISN
ROHDE & SCHWARZ                         ESH3-Z5                    100311      Aug. 19, 2018 Aug. 18, 2019
(Peripheral)
Software                             BV ADT_Cond_
                                                                     NA              NA                NA
ADT                                     V7.3.7.4

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Shielded Room 1.
      3. The VCCI Site Registration No. is C-2040.




Report No.: RF181018C34                        Page No. 19 / 24                        Report Format Version: 6.1.1


4.2.3   Test Procedures
a.   The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
     connected to the power mains through a line impedance stabilization network (LISN). Other support units
     were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50uH of
     coupling impedance for the measuring instrument.
b.   Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c.   The frequency range from 150kHz to 30MHz was searched. Emission levels under (Limit - 20dB) were
     not recorded.
NOTE: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi-peak detection (QP)
      and average detection (AV) at frequency 0.15MHz-30MHz.

4.2.4   Deviation from Test Standard
No deviation.

4.2.5   Test Setup
                                   Vertical Ground
                                   Reference Plane                               Test Receiver


                                   EUT
                      40cm




                                                        80cm
                      LISN



                                                                   Horizontal Ground
                                                                    Reference Plane

                          Note: 1.Support units were connected to second LISN.




For the actual test configuration, please refer to the attached file (Test Setup Photo).

4.2.6   EUT Operating Conditions
Same as 4.1.6.




Report No.: RF181018C34                         Page No. 20 / 24                           Report Format Version: 6.1.1


4.2.7   Test Results
EUT Wireless Charging to Apple Watch Mode + AC adapter
                                                                                    Quasi-Peak (QP) /
Phase                            Line (L)                     Detector Function
                                                                                    Average (AV)
Test Mode                        A


                           Corr.      Reading Value     Emission Level           Limit             Margin
           Freq.
 No                       Factor         [dB (uV)]         [dB (uV)]          [dB (uV)]             (dB)
          [MHz]           (dB)         Q.P.     AV.      Q.P.     AV.       Q.P.       AV.     Q.P.      AV.
  1      0.16569          9.73        39.65    28.05    49.38    37.78     65.17     55.17    -15.79 -17.39
  2      0.24775          9.73        33.64    19.99    43.37    29.72     61.83     51.83    -18.46 -22.11
  3      0.33377          9.74        29.34    13.66    39.08    23.40     59.36     49.36    -20.28 -25.96
  4      0.47844          9.74        25.20     3.75    34.94    13.49     56.37     46.37    -21.43 -32.88
  5      0.79906          9.70        26.44    10.07    36.14    19.77     56.00     46.00    -19.86 -26.23
  6      13.94448         9.91        15.05     7.99    24.96    17.90     60.00     50.00    -35.04 -32.10

Remarks:
               1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. The emission levels of other frequencies were very low against the limit.
               3. Margin value = Emission level - Limit value
               4. Correction factor = Insertion loss + Cable loss
               5. Emission Level = Correction Factor + Reading Value.




Report No.: RF181018C34                          Page No. 21 / 24                       Report Format Version: 6.1.1


                                                                                    Quasi-Peak (QP) /
Phase                            Neutral (N)                 Detector Function
                                                                                    Average (AV)
Test Mode                        A


                           Corr.     Reading Value     Emission Level           Limit              Margin
           Freq.
 No                       Factor        [dB (uV)]         [dB (uV)]          [dB (uV)]              (dB)
           [MHz]          (dB)        Q.P.     AV.      Q.P.     AV.       Q.P.       AV.      Q.P.      AV.
  1       0.15782         9.72       35.93    19.26    45.65    28.98     65.58     55.58     -19.93 -26.60
  2       0.24384         9.73       30.84    17.90    40.57    27.63     61.96     51.96     -21.39 -24.33
  3       0.33377         9.74       27.64    13.55    37.38    23.29     59.36     49.36     -21.98 -26.07
  4       0.49454         9.75       25.49    10.26    35.24    20.01     56.09     46.09     -20.85 -26.08
  5       0.74823         9.73       25.67    14.29    35.40    24.02     56.00     46.00     -20.60 -21.98
  6       5.68265         9.84       20.55    12.76    30.39    22.60     60.00     50.00     -29.61 -27.40

Remarks:
               1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. The emission levels of other frequencies were very low against the limit.
               3. Margin value = Emission level - Limit value
               4. Correction factor = Insertion loss + Cable loss
               5. Emission Level = Correction Factor + Reading Value.




Report No.: RF181018C34                         Page No. 22 / 24                        Report Format Version: 6.1.1


5     Pictures of Test Arrangements
Please refer to the attached file (Test Setup Photo).




Report No.: RF181018C34                        Page No. 23 / 24   Report Format Version: 6.1.1


Appendix – Information on the Testing Laboratories
We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited and approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                       Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-6668565
Fax: 886-2-26051924                                    Fax: 886-3-6668323

Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF181018C34                        Page No. 24 / 24                 Report Format Version: 6.1.1



Document Created: 2019-03-31 10:14:22
Document Modified: 2019-03-31 10:14:22

© 2025 FCC.report