RF Exposure Info

FCC ID: K7SF8J233

RF Exposure Info

Download: PDF
FCCID_4143478

                                                     RF Exposure Test Report

                       Report No.: SA181018C34

                             FCC ID: K7SF8J233

                       Test Model: F8J233

                 Received Date: Oct. 18, 2018

                         Test Date: Nov. 2, 2018

                     Issued Date: Nov. 23, 2018


                         Applicant: Belkin International, Inc.

                          Address: 12045 East Waterfront Drive, Playa Vista, CA 90094 USA


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
         FCC Registration /
       Designation Number: 198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: SA181018C34                                              Page No. 1 / 11                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         General Information .............................................................................................................................. 5
    2.1      General Description of EUT ................................................................................................................ 5
3         RF Exposure .......................................................................................................................................... 6
    3.1      Description of Support Units ............................................................................................................... 6
    3.1.1    Configuration of System under Test .................................................................................................... 6
    3.2      Test Setup ........................................................................................................................................... 7
    3.3      Test Instruments .................................................................................................................................. 7
    3.4      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 8
    3.5      Test Point Description ......................................................................................................................... 8
4         Calculation Result of Maximum Conducted Power........................................................................... 9
5         Photographs of the Test Configuration ............................................................................................. 11




Report No.: SA181018C34                                              Page No. 2 / 11                                             Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA181018C34           Original release                                   Nov. 23, 2018




Report No.: SA181018C34                     Page No. 3 / 11       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: BOOST↑CHARGE™

              Brand: belkin

        Test Model: F8J233

    Sample Status: Engineering sample

          Applicant: Belkin International, Inc.

          Test Date: Nov. 2, 2018

         Standards: FCC Part 1 (Section 1.1307(b), 1.1310)



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                         , Date:        Nov. 23, 2018
                                   Celia Chen / Supervisor




    Approved by :                                                          , Date:        Nov. 23, 2018
                           Rex Lai / Associate Technical Manager




Report No.: SA181018C34                       Page No. 4 / 11                         Report Format Version: 6.1.1


2     General Information
2.1    General Description of EUT

 Product                              BOOST↑CHARGE™
 Test Model                           F8J233
 Sample Status                        Engineering sample
                                      5Vdc (Adapter)
 Power Supply Rating
                                      3.83Vdc (Battery)
 Modulation Type                      FSK
 Operating Frequency                  326.5 kHz
 Antenna Type                         Coil antenna
 Field Strength                       49.5dBuV/m
 Dimension                            7.95cm2 (diameter = 31.82mm)
 Accessory Device                     N/A
 Data Cable Supplied                  0.17m shielded USB cable without core
 Maximum Power Output for
                                      Less than 5W
 Apple watch inductive coil
Note:
1. The EUT uses following battery.
 Brand                                Dongguan Amperex Technology Limited
 Model                                B03543
 Power Rating                         3.83Vdc, 2200mAh

2. The EUT has a wireless inductive charging coil for charging Apple watch.

3. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: SA181018C34                      Page No. 5 / 11                       Report Format Version: 6.1.1


3        RF Exposure
3.1       Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
    ID        Product                Brand               Model No.              Serial No.       FCC ID             Remarks
    A.     Apple Watch               Apple                 A1889              FH7V1006J97R     BCG-A1889         Supplied by client
    B.        Adapter                Apple                 A1385                   NA              NA             Provided by Lab
NOTE: All power cords of the above support units are non-shielded (1.8 m).


    ID      Descriptions              Qty.               Length (m)       Shielding (Yes/No)   Cores (Qty.)         Remarks
    1.      USB cable                  1                    0.17                    Y               0            Supplied by client
Note: The core(s) is(are) originally attached to the cable(s)


3.1.1      Configuration of System under Test

Charging Mode with Apple Watch



                                                            Apple Watch (A)


                                        1
                 Adapter (B)                                       EUT




Standby Mode




                                           1
                 Adapter (B)                                       EUT




Report No.: SA181018C34                                     Page No. 6 / 11                             Report Format Version: 6.1.1


3.2     Test Setup




                                                 15 cm / 20cm




                                                                              EUT

                      Field Probe




Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm or
     20 cm measured from the center of the probe(s) to the edge of the device.

3.3     Test Instruments

       Description         Brand     Model No.     Frequency Range Calibrated Date Calibrated Until
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018      Mar. 27, 2020
       Meter
   Magnetic Field
                          NARDA       ELT-400          1 – 400kHz       Apr. 12, 2018     Apr. 11, 2020
      Meter
  Magnetic Probe          NARDA       HF-3061       300kHz – 30MHz      Apr. 16, 2018     Apr. 15, 2020
  Magnetic Probe          NARDA       HF-0191        27 – 1000MHz       Apr. 17, 2018     Apr. 16, 2020
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018      Mar. 27, 2020
       Meter
Electric Field Meter COMBINOVA        EFM 200         5Hz – 400kHz      Dec. 6, 2017      Dec. 5, 2019
      E-Field Probe       NARDA       EF-0391        100kHz – 3GHz     Mar. 28, 2018      Mar. 27, 2020
      E-Field Probe       NARDA       EF-6091      100MHz – 60GHz        Mar. 29, 2018  Mar. 28, 2020
NOTE: 1. The calibration interval of the above test instruments is 12/24 months and the
          calibrations are traceable to NML/ROC and NIST/USA.
      2. The test was performed in Chia Pau RF Chamber




Report No.: SA181018C34                      Page No. 7 / 11                         Report Format Version: 6.1.1


3.4    Limits for Maximum Permissible Exposure (MPE)
§ 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of
  human exposure to radiofrequency(RF) radiation as specified in § 1.1307(b), except in the case of portable
  devices which shall be evaluated according to the provisions of § 2.1093 of this chapter.




680106 D01 RF Exposure Wireless Charging App v03
The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all
simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

3.5    Test Point Description



                          Z-axis
                                      Top




      Left                                       Right




                 Bottom




Report No.: SA181018C34                      Page No. 8 / 11                        Report Format Version: 6.1.1


4      Calculation Result of Maximum Conducted Power

Charging Mode with Apple Watch, battery 10% Charge
                                         E-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max E-field (V/m)      0.3500          0.1500               0.1800        0.4200               0.2600
       Limit (V/m)          614             614                  614           614                   614
      Margin (V/m)        -613.6500      -613.8500             -613.8200    -613.5800            -613.7400
    50 % Limit (V/m)        307             307                  307           307                   307
50 % Margin (V/m)         -306.6500      -306.8500             -306.8200    -306.5800            -306.7400

                                           H-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max H-field (uT)       0.1450          0.1360               0.1410        0.1480               0.1520
    Max H-field (A/m)      0.1160          0.1088               0.1128        0.1184               0.1216
       Limit (A/m)          1.63            1.63                 1.63          1.63                 1.63
      Margin (A/m)         -1.5140         -1.5212              -1.5172       -1.5116             -1.5084
    50 % Limit (A/m)       0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6990            -0.7062           -0.7022          -0.6966           -0.6934
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.

Charging Mode with Apple Watch, battery 50% Charge
                                         E-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max E-field (V/m)      0.3300          0.2600               0.2400        0.5100               0.3200
       Limit (V/m)          614             614                  614           614                   614
      Margin (V/m)        -613.6700      -613.7400             -613.7600    -613.4900            -613.6800
    50 % Limit (V/m)        307             307                  307           307                   307
50 % Margin (V/m)         -306.6700      -306.7400             -306.7600    -306.4900            -306.6800

                                           H-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max H-field (uT)       0.1510          0.1340               0.1420        0.1580               0.1620
    Max H-field (A/m)      0.1208          0.1072               0.1136        0.1264               0.1296
       Limit (A/m)          1.63            1.63                 1.63          1.63                 1.63
      Margin (A/m)         -1.5092         -1.5228              -1.5164      -1.5036              -1.5004
    50 % Limit (A/m)       0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6942            -0.7078           -0.7014          -0.6886           -0.6854
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA181018C34                      Page No. 9 / 11                          Report Format Version: 6.1.1


Charging Mode with Apple Watch, battery 90% Charge
                                         E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         0.4300          0.2800                0.2600       0.5300               0.3900
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -613.5700      -613.7200              -613.7400   -613.4700            -613.6100
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -306.5700      -306.7200              -306.7400   -306.4700            -306.6100

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1570          0.1520                0.1510       0.1620               0.1690
 Max H-field (A/m)         0.1256          0.1216                0.1208       0.1296               0.1352
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.5044         -1.5084               -1.5092     -1.5004              -1.4948
  50 % Limit (A/m)         0.815            0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.6894            -0.6934           -0.6942          -0.6854           -0.6798
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Standby Mode
                                           E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         0.1600          0.1000                0.1200       0.3100               0.1500
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -613.8400      -613.9000              -613.8800   -613.6900            -613.8500
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -306.8400      -306.9000              -306.8800   -306.6900            -306.8500

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1480          0.1340                0.1350       0.1520               0.1560
 Max H-field (A/m)         0.1184          0.1072                0.1080       0.1216               0.1248
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.5116         -1.5228               -1.5220     -1.5084              -1.5052
  50 % Limit (A/m)         0.815            0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.6966            -0.7078           -0.7070          -0.6934           -0.6902
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.



Report No.: SA181018C34                      Page No. 10 / 11                         Report Format Version: 6.1.1


5    Photographs of the Test Configuration

Please refer to the attached file (Test Setup Photo).



--- END ---




Report No.: SA181018C34                        Page No. 11 / 11   Report Format Version: 6.1.1



Document Created: 2019-03-31 10:14:31
Document Modified: 2019-03-31 10:14:31