                                                                                                CERTIFICATE OF CALIBRATION

   Applicant:                              Bureau Veritas Consumer Products Service (H.K.) Ltd.
                                           Taoyuan Branch

   Order by:                               EMC Instruments corporation
                                           1F, No.8, Lane38 WenSan 3rd street
                                           Kwei—Shan Hsiang Taoyuan Hsien

   Instrument:                             Read out unit + B—field probe (100 MHz—6 GHz)
                                           manufacturer      Narda / Wandel & Goltermann
                                           type              NBM—550 + EF6091
                                           serial number     B—0872+01124
                                           identification    E2—020090 + E2—020088
                                           asset number.     140000123

    Calibration method:                    The calibration is carried out according to IEC 61000—4—3 (2006—02) + A1 (2007—11) + A2 (2010—03).

                                           The instrument was allowed to acclimatize for at least 2 hours before any measurements were made.

                                           During calibration, all axis of the field probe are switched on as in the normalisotropic mode of
                                           operation ofthe probe.

                                           Up to 150 MHz, the calibration is performed in a TEM cell. The calculated field method is used for
                                           the calibration.

                                           The calibration of frequencies from 200 MHz is carried outin a full anechoic room. Over the
                                           frequency range of 200 MHz to 1000 MHz, the standard transfer method is used. For frequencies from
                                            1200 MHz, the calculated field method is used.

                                           The polarization of the E—field is vertical, For each frequency and field strength setting, the field probe
                                           is rotated so that each position is aligned with the E—field. The position undertest is always
                                           perpendicular to the direction of propagation and parallel to the E—field.

                                           Page 11 describes the orientation of the DUT during calibration.

                                                                                              Appliedfield strength
                                                             COPrCHIOA FACLO® = ——.—————«——.ccoce=neccaco====~—~
                                                                                             Measuredfield strength

                                           Position 1: probe horizontal, perpendicular to the field, display horizontal (up). Probe head aligned
                                           with center of the antenna, probe box to the right.


    Certificate number 201600476.00                                                                                                                                                  Page / of 14

    ‘The Raad voor Accreditate is one ofthe signatories ofthe Muliateral   Reproduction ofthe complete centfiate is llowed. Parts of he   This certfate is issued provided that neither DARE1!
    Agreement ofthe European Co—operation for Accredilation (EA) for       certiicatemsy only boreproduced with wrilten approval ofe      Calibrations northe Rasd veor Accrediatie doss assume any
    the mutual recognition ofcallbration cortiicates                       calibration laboratory.                                        Hiabiliy:




Dijkstra Advice, Research & EMC Services B.V.
KvK Uitrechi 30138675
Rabobank Utrechtse Waarden e.0.
IBAN: NLIPRABOOD158313704 *« SWIFT code RABONL2U
Eori—number. NL805613468                                                                                                                                                                       TALBRATION
VAT number: NL8056.13.468.B01                                                                                                                                                                  AvA L061


                                                            DARE!! Calibrations
                                                            Calibration services

  @4                                  //                                                                                  ‘Tel. +31 348 431 807
                                     0 ¢                    Vijzelmolentaan7                                              Fax +31 348 430 645
                                                            3447 GX Woerden                                                      wow.dare.nl
                                                            The Netherlands                                              calibrations@dare.nl




                               Position 2: probe horizontal, perpendicular to the field, display aligned vertical, to the front facing the
                               antenna. Probe head aligned with center of the antenna, probe box to the right.

                               Position 3: probe horizontal, perpendicular to the field, display horizontal (down). Probe head aligned
                               with center of the antenna, probe box to the right.

                               .The linearity is compared to the limits given by the IEC 61000—4—3 standard as mentioned at page 12.

   Ambient conditions:         The calibration was carried out in a screened room, at an ambient temperature of (23 + 2)°C and a
                               relative humidity of (50 + 10)%.

   Period of calibration:      2016 February, 8 to 2016 February, 9.

   Due date:                   2017 February, 9

   Results:                    Final result: PASS. This pass or fail statement excludes the measurement uncertainty.
                               The results are listed on page 5 to 10.
                               The results of comparisons with specifications are shown in the column ‘Remarks®.
                               Reported statements comply with ILAC—G8 (2009—03): ‘Guidelines on the Reporting of Compliance
                               with Specification‘, The following remarks can be reported:

                               (a)          Case 1 — ‘Pass‘ or no remark if:
                                            The measurement result is within (or below) the specification limit when the measurement
                                            uncertainty is taken into account.
                               (b)          Case 4 — ‘Out ofspecs.‘ if:
                                            The measurement result is outside (or above) the specification limit when the measurement
                                            uncertainty is taken into account
                               (c)          Case 2 & 3 — ‘Border value‘ if;
                                            It is not possible to state compliance using a 95% coverage probability forthe expanded
                                            uncertainty.



                                                                              p___}
                                             ILAC—G8 Compllance with specifcation



                                     {                  i                     7               upper limit



                                Case 1              Case 2               Case 3      Case 4
                                                                                               true value
                                                                             —@l—




                                                        +                                     lower limit
                                                                                       i—@—




                                     4 measured value        I uncertainty




                               No adjustments have been made to the instrument.
                               The measured values were calculated from a single sample.

    Certificate number 201600476.00                                                                                            Page 2 of 14



Dijkstra Advice, Research & EMC Services B.V,
KvK Utrecht 30138675
Rabobank Utrechtse Waarden ¢.0.
IBAN: NLIIRABOD1 58313704 « SWIFT code RABONL2U                                                                                        N
Eori—number: NL805613468                                                                                                              CANBRATION
VAT number: NL8056.13.468.B0 1                                                                                                        AvA K063


                                                     DARE!! Calibrations


  DAfse!/
                                                     Calibration services
                                                                                                                       Tel. +31 348 431 807
                                                     Vijzelmoleniaan 7                                                 Fax +31 348 430 645
                                                     3447 GX Woerden                                                           wi.dare.nl
                                                     The Netherlands                                                  calibrations@dare.nl




    Uncertainty:               The reported expanded uncertainty of measurementis stated as the standard uncertainty of
                               measurement multiplied by the coverage factor k=2, which for a normal distribution corresponds to a
                               coverage probability of approximately 95%.The standard uncertainty of measurement has been
                               determined in accordance with EA publication EA—4/02.

                               The uncertainties refer to the measured values only with no account being taken of the ability of the
                               instruments under test to maintain their calibration.

    Traceability:              The measurements have been executed using standards for which the traceability to (inter)national
                               standards has been demonstrated towards the RvA.
                               Description           Identification  Certificate number             Last catibration date
                               Signal Generator      ID 1265         RvA K063/201501248.00          October 2015
                               Power meter           ID 1247         RvA K063/201404632.01         November 2014
                               Power head            ID 1248         RvA K063/201404632.01          November 2014
                               RF Amplifier          ID 7387         D.A.R.EH                       October 2015
                                                                     Calibrations/201501265.00
                               Coupler               ID 7432         RvA K063/201500583.00          April 2015
                               TEM cell              ID 1073         —/No cal required
                               Attenuator 300B       ID 1313         RvA K063/201600022.00          January 2016
                               Termination 50        ID 1545         /No cal required
                               ohms, N—type
                               Radicentre,           ID 7407         /—/No cal required
                               Siemens


                               Description            Identification     Certificate number             Last calibration date
                               Signal Generator       ID 3049            RvA K063/201500914.00          April 2015
                               Signal Generator       ID 7340            RvA K063/201500915.00          April 2015
                               RF Amplifier           ID 1003            D.A.R.EH                       January 2015
                                                                         Calibrations/201405072.00
                               RF Amplifier          ID 1163             D.A.RE!!                       December 2014
                                                                         Calibrations/201405073.00
                               RF Amplifier           ID 1164            —/No cal required
                               RF Amplifier          TD 1347             D.A.RE!                        June 2014
                                                                         Calibrations/201403073.00
                               Power head            ID 7406             RvA K063/201500912.00          May 2015
                               Attenuator 300B       ID 7193             RvA K063/201600013.00          January 2016
                               Attenuator 200B       ID 7196             RvA K063/201600016.00          January 2016
                               Coupler               TD 1005             RvA K063/201501244.00          September 2015
                               Coupler               ID 7422             RyA K063/201503883.00          October 2015
                               Antenna Horn          ID 1218             RvA K063/201401760.00
                               Antenna Horn          ID 1169             RvA K063/201404331.00         November 2014
                               Antenna Horn          ID 7395             7—/No cal required
                               Antenna Horn          ID 1156             RvA K063/201404330.00         November 2014
                               Antenna Hormn         ID   7316           ~/No   cal required
                               Antenna Horn          ID   7317           ~/No   cal required
                               Antenna Homn          1D   7447           ~/No   cal required
                               Antenna Horn          ID   7448           —/No   cal required
                               Antenna Horn          ID   7449           —/No   cal required
    Cortificate number 201600476.00                                                                                        Page 3 of 14



Dijkstra Advice, Research & EMC Services B.V.
KyK Utrecht 30138675
Rabobank Uirechtse Waarden c.0.
                                                                                                                                  is
IBAN: NLIORABOD1 58313704« SWIFT code RABONL2U
                                                                                                                                  talBhalion
                                                                                                                                  AvA K08)
Eori—number: NL805613468
VAT number: NL8056.13.468.B01


                                                       DARE!! Calibrations
                                                       Calibration services

  DAfi!/                                                Vijzelnolenlaan 7
                                                       3447 GX Woerden
                                                       The Netherlands
                                                                                                                   Tel. +31 348 431 807
                                                                                                                   Fax +31 348 430 645
                                                                                                                           ww.dare.l
                                                                                                                  calibrations@dare.al




                                  Description          Identification      Certificate number    Last calibration date
                                  Antenna Horn         ID 7450             —/No cal required
                                  Antenna Hom          ID 7293             =/No cal required
                                  Antenna Horn         TD 7294             =/No cal required
                                  Field sensor         ID 7457             NPL/2015080200—1      September 2015
                                  Field sensor         ID 7273             NPL/2014090127—1      September 2014
                                  Anechoic Room        ID 7092             ~/No cal required



                                  Date                              Calibrated by               Checked by

                                                  27



                                  2016 February,(                   B. Ahyud                               er Viugt
                                                                    Calibration Engineer        Director




    Certificate number 201600476.00                                                                                     Page 4 of 14



Dijkstra Advice, Research & EMC Services B.V.
KvK Uirecht 30138675
Rabobank Utrechtse Waarden e.0.
TBAN: NLIORABOO158313704 « SWIFT code RABONL2U
Eorinumber: NL805613468
VAT number: NL8056.13,468.B01


                                                       DARE!! Calibrations


  D»Afae!/
                                                       Calibration services
                                                                                               ‘Tel. +31 348 431 807
                                                       VijzelmolenIaan7                        Fax +31 348 430 645
                                                       3447 GX Woerden                                  wir.dare.nl
                                                       The Netherlands                        calibrations@dare.nl




     E—field Probe linearity (Position 1)
     Frequency: 150 MHz
     Range: range less

     APPLIED        MEASURED            LINEARITY#              REMARKS          CORRECTION
     FIELD          FIELD               UNCERTANTY              DUETO            FACTOR
     [V/m]           [V/m]                                      SPECIFICATIONS

     10,04           8,64               (0,3 + 0,6) dB          Border value     1,16
     11,28           9,74               (0,2 + 0,6) dB          Border value     1,16
     12,67           10,96              (0,2 + 0,6) dB          Border value     1,16
     14,22           12,37              (0,2 + 0,5) dB          Border value     1,15
     16,0            14,0               (0,1 + 0,5) dB          Border value     1,15
     17,9            15,7               (0,1 +0,5) dB           Border value     1,14
     20,1            17,8               0 dB (Reference)                         1,13
     22,5            20,1               (—0,07 + 0,37) dB                        1,12
     25,3            22.9               (—0,17 + 0,35) dB       Border value     L1
     28,4            26.0               (—0,29 + 0,34) dB       Border value     1,09
     31,6            29,4               (—0,41 +0,33) dB        Border value     1,08
     35,5            33,5               (—0,56 + 0,32) dB       Border value     1,06
     39,9            38,5               (—0,75 + 0,31) dB       Border value     1,04



     E—field Probe linearity (Position 2)
     Frequency: 150 MHz
     Range: range less

     APPLIED         MEASURED           LINEARITY+              REMARKS          CORRECTION
     FIELD           FIELD              UncERTANTYy             DUETO            FACTOR
     [V/m]           [V/m]                                      SPECIFICATIONS

     10,04           8,51               (0,2 + 0,7) dB          Border value     1,18
     11,29           9,59               (0,2 + 0,6) dB          Border value     1,18
     12,67           10,80              (0,2 + 0,6) dB          Border value     1,17
     14,22           12,18              (0,2 +0,5) dB           Border value     1,17
     16,0            13,8               (0,1 + 0,5) dB          Border value     1,16
     17,9            15,5               (0,1 +0,5) dB                            1,15
     20,1            17,5               0 dB (Reference)                         1,15
     22,5            19,8               (—0,08 + 0,38) dB                        1,14
     25,3            22,5               (—0,18 +   0,36)   dB   Border value     1,12
     28.4            25,6               (—0,29 +   0,34)   dB   Border value     L1
     31,6            28,9               (—0,40 +   0,33)   dB   Border value     1,10
     35,4            32,9               (—0,55 +   0,32)   dB   Border value     1,08
     39,8            37,8               (—0,74 +   0,31)   dB   Border value     1,05




    Certificate number 201600476.00                                                                 Page 5 of 14



Dijkstra Advice, Research & EMC Services B.V.


                                                                                                       Ci.
KyK Utrecht 30138675
Rabobank Utrechtse Waarden c.0
IBAN: NLIPRABOOD158313704 « SWIFT code RABONL2U
Eori—number: NL805613468                                                                                CALIBAATIOX
VAT number: NL8056.13.468.B01                                                                               AvA K063


                                                      DARE!! Calibrations


 TD»Afae!/
                                                      Calibration services
                                                                                             Tel. +31 348 431 807
                                                      VijzelmolenIaan 7                      Fax +31 348 430 645
                                                      3447 GX Woerden                                wrw.dare.nl
                                                      The Netherlands                       calibrations@dare.nl




    E—field Probe linearity (Position 3)
    Frequency: 150 MHz
    Range: range less

    APPLIED       MEASURED           LINEARITY+               REMARKS          CORRECTION
    FIELD         FIELD              uncErtamity              DUETO            FACTOR
    [V/m]         [V/m]                                       SPECIFICATIONS

    10,04         8,73               (0,2 + 0,6) dB           Border value     1,15
    11,27         9,84               (0.2   + 0,6)   dB       Border value     1,15
    12,66         11,07              (0,2   + 0,5)   dB       Border value     1,14
    14,21         12,48              (0.2   + 0,5)   dB       Border value     1,14
    16,0          14,1               (0,1   + 0,5)   dB       Border value     1,13
    17,8          15,8               (0,1 + 0,4) dB                            1,13
    20,1          18,0               0 dB (Reference)                          1,12
    22,5          20,4               (—0,09 + 0,37) dB                         1,11
    25,3          23,1               (—0,18 + 0,35) dB        Border   value   1,09
    28,4          26,3               (—0,30 + 0,33) dB        Border   value   1,08
    31,6          29,7               (—0,44 + 0,32) dB        Border   value   1,06
    354           33,9               (—0,59 + 0,31) dB        Border   value   1,04
    39,8          38,9               (—0,77 +0,31) dB         Border   value   1,02




   Certificate number 201600476.00                                                                Page 6 of 14



Dijkstra Advice, Research & EMC Services B.V.
KvK Uirecht 30138675
Rabobank Utrechtse Waarden .0.
                                                                                                         S
IBAN: NLI9RABOOD158313704 « SWIFT code RABONL2U
                                                                                                         tldhaon
Eori—number: NL805613468
VAT number: NL8056.13,468.B01                                                                            Avk 06


                                                  DARE!! Calibrations


  D»Afae//
                                                   Calibration services
                                                                                                     Tel. +31 348 431 807
                                                  VijzeImolentnan 7                                  Fax +31 348 430 645
                                                  3447 GX Woerden                                           wr.dare.nl
                                                  The Netherlands                                    calibrations@dare.ol




    E—field Probe frequency response
    Frequency range: 100 MHz— 150 MHz
    Probe orientation: monopole in the same plane as E—field
    Septum height: 0,45 m
    Range: range less

    FREQUENCY            APPLIED FIELD             MEASURED FIELD         CF + UNCERTAINTY
    [MHz]                [V/m]                     [V/m]
                         Pos 1  Pos2   Pos3        Posi  |Pos2  Pos3      Pos 1                       Pos 3
    100                  19,9   19,9   19,9        164   15,9   16,1      1,21 + 0,24   1,25+0,25     1,23 +0,24
    150                  20     20     20          17,7  17,5   18,0      1,13 + 0,23                 1,11 + 0,22




    Certificate number 201600476.00                                                                       Page 7 of 14



Dijkstra Advice, Research & EMC Services B.V.
KvK Utrecht 30138675
Rabobank Uirechise Waarden c.0.
                                                                                                                 i
IBAN: NLIIRABOD1 58313704 * SWIFT code RABONL2U
Eorinumber: NL805613468                                                                             es           PRTT]
VAT number: NL8056.13.468.B01                                                                       Tm®"         WA


                                                       DARE!! Calibrations


  DATecl!! rrssas
                                                       Calibration services
                                                                                                            Tel. +31 348 431 807
                                                                                                            Fax +31 348 430 645
                                                       3447 GX Woerden                                              wirw.dare.nl
                                                       The Netherlands                                     callbrations@dare.n1




   E—field Probe frequency response
   Frequency range: 200 MHz— 1000 MHz
   Probe orientation: monopole in the same plane as E—field
   Antenna distance: 2,0 m
   Range: rangeless


   FREQUENCY           APPLIED FIELD                   MEASURED FIELD         CF + UNCERTAINTY
   [MHz]               [V/m]                           [V/m]
                       Pos 1  Pos2              Pos3   Pos 1 Pos 2  Pos3      Pos 1         Pos 2            Pos 3
   200                 20,1   19,9              20,0   19,8  17,6   19,6      1,01 + 0,15   1,13+0,17        1,02 + 0,15
   250                 19,9   19,8              20,0   20,6  18,5   19,5      0,96 + 0,14   1,07 + 0,16      1,03 + 0,15
   300                 204    20,3              20,4   22,0  20,8   21,3      0,93 + 0,14   0,97 + 0,14      0,96 + 0,14
   350                 20,0   19,9              20,1   21,7  19,4   20,5      0,92 + 0,14   1,03 + 0,15      0,98 + 0,15
   400                 19,9   19,9              19,8   22,0  19,9   21,6      0,90 + 0,13   1,00+0,15        0,92 + 0,14
   450                 19,7   19,8              19,9   216   20,2   22,7      0,91 + 0,14   0,98 + 0,15      0,88 + 0,13
   500                 19,5   19,6              19,6   21,2  20,2   23,3      0,92 + 0,14   0,97 + 0,14      0,84 + 0,12
   550                 19,8   19,8              19,9   21,1  19,4   22,2      0,94 + 0,14   1,02+0,15        0,89 + 0,13
   600                 19,8   19,7              19,9   21,9  20,1   23,1      0,90 + 0,13   0,98 + 0,15      0,86 + 0,13
   650                 20,3   20,3              20,2   224   21,2   22,8      0,91 + 0,13   0,95 + 0,14      0,89 + 0,13
   700                 20,3   20,3              20,3   224   22,0   22,9      0,91 + 0,13   0,92 + 0,14      0,88 + 0,13
   750                 19,6   19,8              19,7   22,1  22,7   22,0      0,89 + 0,13   0,87 + 0,13      0,89 + 0,13
   800                 20,0   19,9              19,9   23.3  23,1   22,8      0,86 + 0,13   0,86 + 0,13      0,87 + 0,13
   850                 20,2   20,2              20,2   25,0  23,0   23,2      0,81 + 0,12   0,88 + 0,13      0,87 + 0,13
   900                 20,2   20,2              20,2   25,1  22,0   23,6      0,81 + 0,12   0,92 + 0,14      0,86 + 0,13
   950                 20,5   20,5              20,4   23,3  21,0   21,9      0,88 + 0,13   0,98 3: 0,14     0,93 + 0,14
   1000                19,8   19,8              19.9   217   20,1   20,9      0.91 + 0,14   0,99 + 0,15      0,95 + 0,14




    Certificate number 201600476.00                                                                              Page 8 of 14



Dijkstea Advice, Research & EMC Services B.V.
KvK Utrecht 30138675
Rabobank Uirechtse Waarden e.0.
IBAN: NLIIRABOO158313704 e SWIFTcode RABONL2U
Eori—number: NL805613468                                                                                                CALIORATIO¢
VAT number: NL8056.13.468,B01                                                                                           fivA £08)


                                                       DARE!! Calibrations


  D»Afae //
                                                       Calibration services
                                                                                                          Tel. +31 348 431 807
                                                       Vijzelmoteniaan 7                                  Fax +31 348 430 645
                                                       3447 GX Woerden                                            wiw.dare.nl
                                                       The Netherlands                                    calibrations@dare.ol




    E—field Probe frequency response
    Frequency range: 1200 MHz~— 6000 MHz
    Probe orientation: monopole in the same plane as E—field
    Antenna distance: 1,0 m
    Range: rangeless

    FREQUENCY            APPLIED FIELD                  MEASURED FIELD        CF + UNCERTAINTY
    [MHz]                [V/m]                          [V/m)
                         Pos 1  Pos2            Pos3    Posi  Pos2   Pos3     Pos1          Pos 2          Pos 3
    1200                 20,0   19,9            19,9    21,7  19.4   22,1     0,92 + 0,14   1,03 + 0,15    0,91 + 0.14
    1400                 20,0   20,0            20,0    21,8  20,9   21,9     0,92 +0,12    0,96 + 0,13    0,92 + 0,12
    1600                 20,1   20,1            20,1    24,1  22,2   23,6     0,83 + 0,11   0,91 + 0,12    0,85 + 0,11
    1800                 20,1   19,9            19,9    23,0  21,4   23.4     0,87 + 0,14   0,93+ 0,15     0,86 + 0,14
    2000                 20,0   19,9            19,9    218   18,9   214      0,92 + 0,15   1,06 + 0,17    0,94 + 0,15
    2200                 20,0   19,9            19,9    21,0  16,7   20,8     0,95 + 0,16   1,19+ 0,20     0,96 + 0,16
    2400                 20,0   20,1            20,1    21,9  20,3   22,0     0,92 + 0,15   0,99 + 0,16    0,91 +0,15
    2600                 20,0   20,1            20,1    21,8  20,3   21,5     0,92 + 0,15   0,99 + 0,16    0,93 + 0,15
    2800                 20,0   20,0            20,0    224   18,9   23,3     0,89 + 0,14   1,06 + 0,17    0,87 + 0,14
    3000                 20.0   20,0            20,0    20,5  18,1   20,7     0,97+0,16     1,10+0,18      0,97 + 0,16
    3200                 20,0   20,0            20,0    20,5  17,0   20,2     0,97 + 0,16   1,18 + 0,19    0,99 + 0,16
    3400                 19,9   19,9            19,9    19,9  17,5   18,9     1,00 + 0,16   1,14 + 0,19    1,06 + 0,17
    3600                 20,0   20,2            20,2    21,6  19,7   21,6     0,93 + 0,15   1,02 + 0,17    0,93 + 0,15
    3800                 19,9   19,9            19,9    20,0  17,8   20,4     0,99 + 0,16   1,12+ 0,18     0,99 + 0,16
    4000                 20,0   20,0            20,0    20,5  16,3   20,8     0,97 + 0,16   1,23 + 0,20    0,96 + 0,16
    4200                 20,2   20,1            20,1    18,9  15,8   19,1     1,07+0,16     1,28 + 0,19    1,05 + 0,16
    4400                 20,0   20,2            20,2    19,7  17,2   19,5     1,01 + 0,16   1,17+0,18      1,03+0,16
    4600                 20,1   20,0            20,0    19,5  17,4   18,5     1,03+0,16     1,15 + 0,18    1,08 + 0,16
    4800                 20,0   20,0            20,0    20,6  17,0   19,4     0,98 + 0,15   1,17+0,18      1,03 +0,16
    5000                 20,1   20,0            20,0    20,4  16,5   20,0     0,98 + 0,15   1,22+0,19      1,01 + 0,15
    5200                 20,0   19,9            19,9    19,4  15,6   19,9     1,03 + 0,16   1,28 + 0,20    1,00 + 0,15
    5400                 20,1   19.9            19,9    19,5  17,0   19,4     1,03 + 0,16   1,17+0,18      1,04+ 0,16
    5600                 20,0   20,0            20,0    19,3  16,9   19.4     1,04+0,16     1,18 + 0,18    1,03 + 0,16
    5800                 19,9   20,1            20,1    18,7  16,3   18,6     1,07+0,16     1,23+0,19      1,08 + 0,16
    6000                 20.0   20,1            20,1    19.4  15.3   18,6     1,03 + 0,16   1,31 + 0,20    1,07 + 0,16




    Certificate number 201600476.00                                                                            Page 9 of 14



Dijkstra Advice, Research & EMC Services B.V.
KvK Utrecht 30138675
Rabobank Uirechise Waarden ¢.0.
IBAN: NLIORABOO1 58313704 « SWIFTcode RABONL2U                                                                        Is<
Eori—number: NL805613468                                                                                              CALIBRANOX
VAT number: NL8056.13.468.B01                                                                                         AvA K061


                                                        DARE!! Calibrations


  PEra~AM
                                                        Calibration services
                                                                                                 Tel. +31 348 431 307
                                                        VijzelniolenIaan7                        Fax +31 348 430 648
                                                        3447 GX Woerden                                  wwy.dare.nl
                                                        The Netherlands                         calibrations@dare.nl




        E—field Probeisotropy
        Applied field: 20 V/m

        FREQUENCY            MEASURED           MEASURED         MEASURED      ANISOTROPY+
                             FIELD              FIELD             FIELD        UNCERTAINTY
                             Position 1         Position 2        Position 3
        [MHz]                [V/m]              [V/m]             [V/m]        [dB]
        100                  16,5 V/m           16,1 V/m          16,3 V/m     (0,1 + 2,2) dB
        1000                 22,0 V/m           20,2 V/m          21,1 V/m     (0,4 + 1,70 dB




    Certificate number 201600476.00                                                                 Page 10 of 14



Dijkstra Advice, Research & EMC Services B.V.
KyK Uirecht 30138675
Rabobank Utrechtse Waarden e.0.
IBAN: NLIORABOO158313704 *« SWIFT code RABONL2U                                                              NR
Eori—number: NL805613468                                                                                    CAlIDRAHON
VAT number: NL8056.13.468.B01                                                                               AvA £08)


                                                 DARE!! Calibrations


  TD»Afae //
                                                 Calibration services
                                                                               Tel. +31 348 431 807
                                                 Vijzelmoleniaan 7             Fax +31 348 430 645
                                                 3447 GX Woerden                       wy.dare.nl
                                                 The Netherlands              calibrations@dare.nl




                                                       Correction Factor
         2,00 >




         1,60



         140



         120



     (cFl 100                                                                      ——Position 1
                                                                                   ——Position 2
                                                                                   ——Position 3



         0.60


         040

         0,20

         0,00 +
              10
                                                              MHz




   Certificate number 201600476.00                                                Page // of 14



Dijkstra Advice, Research & EMC Services B.V.
KyK Utrecht 30138675

                                                                                  Ch
Rabobank Utrechtse Waarden e.0.                                            u*
IBAN: NLI9RABOOL58313704 « SWIFT code RABONL2U
Eori—number: NL805613468
                                                                           inssok
                                                                            ze     CAIBRANION
                                                                           )




VATnumber: NL8056.13.468.B01                                                 Ahaits®
                                                                               ANS
                                                                                          AvA L05]


                                                 DARE!! Calibrations
                                                 Calibration services
  @%                                 //                                                      Tel. +31 348 431 807
                                    0   0        VijzeImolenIaan7                            Fax +31 348 430 645
                                                 3447 GX Woerden                                    worw.dare.ol
                                                 The Netherlands                           calibrations@dare.nl




                   Probe orientation in Tem Cell 10 kHz — 150 MHz(Input side view )

                  Position 1



                                                                                1 Septum




                  Position 2




                                                                                    Septum




                                            |
                  Position 3                |
                                            |                                   |
                                            |                                   i
                                            |                                   |
                                            l                                       Septum


                                            |

                                            ||
                                            1
                                                                    (| )C
    Certificate number 201600476.00         2                       _   l   .                   Page 12 of 14



Dijkstra Advice, Research & EMC Services B.V.
KvK Uirecht 30138675
Rabobank Utrechtse Waarden e.0.
TBAN: NLIORABOO1S8313704 « SWIFT code RABONL2U                                                           h
Eori—number. NL805613468                                                                                 CALORANIOX
VAT number: NLB056.13.468.301                                                                            AivA £08


                                                 DARE!! Calibrations
                                                 Calibration services

  @%2go/o/                                       VijzeImotentaan7
                                                                                   Tel. +31 348 431 807
                                                                                   Fax +31 348 430 645
                                                 3447 GX Woerden                           wiw.dare.nl
                                                 The Netherlands                  calibrations@dare.nl




                        Probe orientation in anechoic room 200 MHz — 40 GHz (Top view)




                         Position 1




                        Position 2




                        Position 3                                  CTThe—




    Certificate number 201600476.00                                                   Page 13 of 14



Dijkstra Advice, Research & EMC Services B.V.
KvK Utrecht 30138675
Rabobank Utrechtse Waarden e.0
                                                                                              I$
TBAN: NL19RABOOLS8313704 « SWIFT code RABONL2U
                                                                                              muBation
                                                                                              AvA LK
Eori—number: NL805613468
VAT mumber: NL8056.13.468.B0 1


                                                 DARE!! Calibrations
                                                 Calibration services
  @%                                //                                           Tel. +31 348 431 807
                                   0    ¢        Vijzelmoleniaan7                Fax +31 348 430 648
                                                 3447 GX Woerden                        www.dare.ol
                                                 The Netherlands                calibrations@dare.al




   IEC 61000—4—3 (2006—02) + A1 (2007—11) + A2 (2010—03) specifications

   Linearity check                                                  + 0,5 dB




    Certificate number 201600476.00                                                 Page 14 of 14



Difkstra Advice, Research & EMC Services B.V.
KvK Uirecht 30138675                                                           sn        L/L
Rabobank Utrechise Waarden e.0.                                                s           <
TBAN: NLI9RABOOL58313704 e SWIFT code RABONL2U                                 inevek WB
Eori—number: NL805613468                                                       y               CALIORANIOX
VAT number: NL8056.13.468.B01                                                  "Adade          AvA LO6)



Document Created: 2017-11-22 09:36:52
Document Modified: 2017-11-22 09:36:52

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC