RF Exposure Info (MPE)

FCC ID: K7SF8J183V2

RF Exposure Info

Download: PDF
FCCID_4432619

                                                     RF Exposure Test Report

                       Report No.: SA190709C07 R1

                             FCC ID: K7SF8J183V2

                       Test Model: F8J183V2

                 Received Date: Jul. 9, 2019

                         Test Date: Jul. 15, 2019

                     Issued Date: Sep. 4, 2019


                         Applicant: Belkin International, Inc.

                          Address: 12045 East Waterfront Drive, Playa Vista, CA 90094


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Lin Kou Laboratories
                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
         FCC Registration /
       Designation Number: 198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: SA190709C07 R1                            Page No. 1 / 11                                                           Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019


                                                                   Table of Contents
Report Issue History Record .......................................................................................................................... 3
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         General Information .............................................................................................................................. 5
    2.1      General Description of EUT ................................................................................................................ 5
3         RF Exposure .......................................................................................................................................... 6
    3.1      Description of Support Units ............................................................................................................... 6
    3.1.1    Configuration of System under Test .................................................................................................... 6
    3.2      Test Setup ........................................................................................................................................... 7
    3.3      Test Instruments .................................................................................................................................. 7
    3.4      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 8
    3.5      Test Point Description ......................................................................................................................... 8
4         Calculation Result of Maximum Conducted Power........................................................................... 9
5         Photographs of the Test Configuration ............................................................................................. 11




Report No.: SA190709C07 R1                            Page No. 2 / 11                                                            Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019


                                              Report Issue History Record

Issue No.                Description                                               Date Issued
SA190709C07              Original release.                                         Aug. 6, 2019
SA190709C07 R1           Modify product name.                                      Sep. 4, 2019




                                                Release Control Record


Issue No.                Description                                               Date Issued
SA190709C07              Original release.                                         Aug. 6, 2019
SA190709C07 R1           Modify product name.                                      Sep. 4, 2019




Report No.: SA190709C07 R1                            Page No. 3 / 11       Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019


1    Certificate of Conformity


             Product: Charge Dock for Apple Watch + iPhone

               Brand: belkin

         Test Model: F8J183V2

     Sample Status: Engineering sample

           Applicant: Belkin International, Inc.

           Test Date: Jul. 15, 2019

          Standards: FCC Part 2 (Section 2.1091)

                          FCC Part 1 (Section 1.1307(c) and (d), Section 1.1310)
                          KDB 680106 D01 RF Exposure Wireless Charging v03




The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                          , Date:        Sep. 4, 2019
                                         Celia Chen / Supervisor




     Approved by :                                                          , Date:        Sep. 4, 2019
                                Rex Lai / Associate Technical Manager




Report No.: SA190709C07 R1                            Page No. 4 / 11                 Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019


2     General Information
2.1    General Description of EUT

 Product                           Charge Dock for Apple Watch + iPhone
 Test Model                        F8J183V2
 Sample Status                     Engineering sample
 Rating                            12Vdc (Adapter)
 Modulation Type                   FSK
 Operating Frequency               326.5 kHz
 Antenna Type                      Coil antenna
 Field Strength                    52.86dBuV/m
 Dimensions                        3.80cm2 (diameter = 22mm)
 Accessory Device                  Adapter
 Data Cable Supplied               N/A
 Maximum Power Output
                                   5W
 from the Charging Coil
Note:
1. The EUT has a wireless inductive charging coil for charging Apple Watch.
2. The EUT uses following adapter.
 Brand                      HOIOTO
 Model                      ADS-25SGP-12 12019E
 Input Power                100-240Vac, 50/60Hz, 0.7A Max.
 Output Power               12Vdc, 1.6A
 Power Line                 1.45m non-shielded DC cable without core attached on adapter
3. After the evaluation of the metal and plastic band on Apple Watch, the metal band was the worst case for
   final test and therefore only its test data was recorded in this report.
4. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: SA190709C07 R1                            Page No. 5 / 11               Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019


3        RF Exposure
3.1       Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
    ID        Product            Brand              Model No.              Serial No.         FCC ID             Remarks
    A.      Apple Watch          Apple                A1554                   NA                NA            Supplied by client
    B.     iPhone XS Max         Apple                A2101                   NA                NA            Supplied by client


    ID      Descriptions          Qty.              Length (m)         Shielding (Yes/No)   Cores (Qty.)         Remarks
    1.       DC cable                 1                   1.45                 N                 0            Supplied by client




3.1.1      Configuration of System under Test

Charging Mode with Apple Watch



                                           iPhone (B)              Apple Watch (A)
                                              Lightning


                                  1
               Adapter (EUT)                                     EUT




Standby Mode

                                              Lightning



                                  1                              EUT
              Adapter (EUT)




Report No.: SA190709C07 R1                            Page No. 6 / 11                                Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019


3.2     Test Setup




                                                          15 cm / 20cm




                                                                                     EUT

                      Field Probe




Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm or
     20 cm measured from the center of the probe(s) to the edge of the device.

3.3     Test Instruments

       Description           Brand          Model No.        Frequency Range Calibrated Date Calibrated Until
  Broadband Field
                            NARDA            NBM-550                    -      Mar. 28, 2018    Mar. 27, 2020
       Meter
   Magnetic Field
                            NARDA            ELT-400            1 – 400kHz     Apr. 12, 2018    Apr. 11, 2020
      Meter
  Magnetic Probe            NARDA            HF-3061         300kHz – 30MHz    Apr. 16, 2018    Apr. 15, 2020
  Magnetic Probe            NARDA            HF-0191          27 – 1000MHz     Apr. 17, 2018    Apr. 16, 2020
  Broadband Field
                            NARDA            NBM-550                    -      Mar. 28, 2018    Mar. 27, 2020
       Meter
Electric Field Meter COMBINOVA               EFM 200           5Hz – 400kHz     Dec. 6, 2017    Dec. 5, 2019
      E-Field Probe         NARDA            EF-0391          100kHz – 3GHz    Mar. 28, 2018    Mar. 27, 2020
      E-Field Probe         NARDA            EF-6091         100MHz – 60GHz    Mar. 29, 2018    Mar. 28, 2020

NOTE: 1. The calibration interval of the above test instruments is 12/24 months and the
          calibrations are traceable to NML/ROC and NIST/USA.
      2. The test was performed in Chia Pau RF Chamber
      3. Determining compliance based on the results of the compliance measurement, not taking into
         account measurement instrumentation uncertainty.




Report No.: SA190709C07 R1                            Page No. 7 / 11                      Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019


3.4    Limits for Maximum Permissible Exposure (MPE)
§ 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of
  human exposure to radiofrequency(RF) radiation as specified in § 1.1307(b), except in the case of portable
  devices which shall be evaluated according to the provisions of § 2.1093 of this chapter.




680106 D01 RF Exposure Wireless Charging App v03
The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all
simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

3.5    Test Point Description



                            Z-axis
                                              Top




      Left                                                Right




                   Bottom




Report No.: SA190709C07 R1                            Page No. 8 / 11               Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019


4   Calculation Result of Maximum Conducted Power
Charging Mode with Apple Watch
Charging Mode with Apple Watch, battery 10% Charge
                                         E-Field Measurement
      Distance                                                15cm                                          20cm
      EUT Side                  Left                Right                 Top        Bottom                Z-axis
 Max E-field (V/m)            0.2900               0.3100                0.4100      0.3500                0.3600
     Limit (V/m)                614                  614                  614         614                    614
    Margin (V/m)            -613.7100            -613.6900              -613.5900   -613.6500            -613.6400
  50 % Limit (V/m)              307                  307                  307         307                    307
50 % Margin (V/m)           -306.7100            -306.6900              -306.5900   -306.6500            -306.6400

                                                   H-Field Measurement
      Distance                                                15cm                                          20cm
      EUT Side                  Left                Right                 Top        Bottom                Z-axis
  Max H-field (uT)            0.0830               0.0900                0.0930      0.0920                0.0980
 Max H-field (A/m)            0.0664               0.0720                0.0744      0.0736                0.0784
     Limit (A/m)                1.63                1.63                  1.63        1.63                  1.63
    Margin (A/m)              -1.5636              -1.5580               -1.5556     -1.5564              -1.5516
  50 % Limit (A/m)             0.815                0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.7486            -0.7430           -0.7406          -0.7414           -0.7366
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.

Charging Mode with Apple Watch, battery 50% Charge
                                         E-Field Measurement
      Distance                                                15cm                                          20cm
      EUT Side                  Left                Right                 Top        Bottom                Z-axis
 Max E-field (V/m)            0.3200               0.3500                0.4700      0.3800                0.4000
     Limit (V/m)                614                  614                  614         614                    614
    Margin (V/m)            -613.6800            -613.6500              -613.5300   -613.6200            -613.6000
  50 % Limit (V/m)              307                  307                  307         307                    307
50 % Margin (V/m)           -306.6800            -306.6500              -306.5300   -306.6200            -306.6000

                                                   H-Field Measurement
      Distance                                                15cm                                          20cm
      EUT Side                  Left                Right                 Top        Bottom                Z-axis
  Max H-field (uT)            0.0860               0.0920                0.0960      0.0950                0.1020
 Max H-field (A/m)            0.0688               0.0736                0.0768      0.0760                0.0816
     Limit (A/m)                1.63                1.63                  1.63        1.63                  1.63
    Margin (A/m)              -1.5612              -1.5564               -1.5532     -1.5540              -1.5484
  50 % Limit (A/m)             0.815                0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.7462            -0.7414           -0.7382          -0.7390           -0.7334
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190709C07 R1                            Page No. 9 / 11                         Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019


Charging Mode with Apple Watch, battery 90% Charge
                                         E-Field Measurement
      Distance                                                15cm                                           20cm
      EUT Side                  Left                Right                  Top        Bottom                Z-axis
 Max E-field (V/m)            0.3600               0.3800                 0.5200      0.4500                0.4800
     Limit (V/m)                614                  614                   614         614                    614
    Margin (V/m)            -613.6400            -613.6200               -613.4800   -613.5500            -613.5200
  50 % Limit (V/m)              307                  307                   307         307                    307
50 % Margin (V/m)           -306.6400            -306.6200               -306.4800   -306.5500            -306.5200

                                                  H-Field Measurement
      Distance                                                15cm                                           20cm
      EUT Side                  Left                Right                  Top        Bottom                Z-axis
  Max H-field (uT)            0.0900               0.0960                 0.1010      0.0990                0.1060
 Max H-field (A/m)            0.0720               0.0768                 0.0808      0.0792                0.0848
     Limit (A/m)                1.63                1.63                   1.63        1.63                  1.63
    Margin (A/m)              -1.5580             -1.5532                 -1.5492     -1.5508              -1.5452
  50 % Limit (A/m)             0.815                0.815                  0.815       0.815                0.815
50 % Margin (A/m)       -0.7430            -0.7382           -0.7342          -0.7358           -0.7302
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Standby Mode
                                                   E-Field Measurement
      Distance                                                15cm                                           20cm
      EUT Side                  Left                Right                  Top        Bottom                Z-axis
 Max E-field (V/m)            0.1100               0.2000                 0.1200      0.2000                0.1700
     Limit (V/m)                614                  614                   614         614                    614
    Margin (V/m)            -613.8900            -613.8000               -613.8800   -613.8000            -613.8300
  50 % Limit (V/m)              307                  307                   307         307                    307
50 % Margin (V/m)           -306.8900            -306.8000               -306.8800   -306.8000            -306.8300

                                                  H-Field Measurement
      Distance                                                15cm                                           20cm
      EUT Side                  Left                Right                  Top        Bottom                Z-axis
  Max H-field (uT)            0.0890               0.0910                 0.0900      0.0940                0.0960
 Max H-field (A/m)            0.0712               0.0728                 0.0720      0.0752                0.0768
     Limit (A/m)                1.63                1.63                   1.63        1.63                  1.63
    Margin (A/m)              -1.5588             -1.5572                 -1.5580     -1.5548              -1.5532
  50 % Limit (A/m)             0.815                0.815                  0.815       0.815                0.815
50 % Margin (A/m)       -0.7438            -0.7422           -0.7430          -0.7398           -0.7382
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.



Report No.: SA190709C07 R1                            Page No. 10 / 11                         Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019


5    Photographs of the Test Configuration

Please refer to the attached file (Test Setup Photo).



--- END ---




Report No.: SA190709C07 R1                            Page No. 11 / 11   Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190709C07 dated Aug. 6, 2019