Test Report

FCC ID: K7SF7U094

Test Report

Download: PDF
FCCID_4414492

                                                            FCC Pretest Report

                       Report No.: RF190724C15

                            FCC ID: K7SF7U094

                       Test Model: F7U094

                 Received Date: Jul. 24, 2019

                         Test Date: Jul. 25 ~ Jul. 30, 2019

                     Issued Date: Aug. 15, 2019


                         Applicant: Belkin International, Inc.

                           Address: 12045 East Waterfront Drive, Playa Vista, CA 90094


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)
         FCC Registration / 788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: RF190724C15                                               Page No. 1 / 33                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         Summary of Test Results ..................................................................................................................... 5
    2.1      Measurement Uncertainty ................................................................................................................... 5
    2.2      Modification Record ............................................................................................................................ 5
3         General Information .............................................................................................................................. 6
    3.1      General Description of EUT ................................................................................................................ 6
    3.2      Description of Test Modes ................................................................................................................... 6
    3.2.1    Test Mode Applicability and Tested Channel Detail ............................................................................. 7
    3.3      Description of Support Units ............................................................................................................... 8
    3.3.1    Configuration of System under Test .................................................................................................... 8
    3.4      General Description of Applied Standards .......................................................................................... 8
4         Test Types and Results ........................................................................................................................ 9
    4.1      Radiated Emission and Bandedge Measurement............................................................................... 9
    4.1.1    Limits of Radiated Emission and Bandedge Measurement ................................................................ 9
    4.1.2    Test Instruments ................................................................................................................................ 10
    4.1.3    Test Procedures.................................................................................................................................. 11
    4.1.4    Deviation from Test Standard ............................................................................................................. 11
    4.1.5    Test Set Up ........................................................................................................................................ 12
    4.1.6    EUT Operating Conditions................................................................................................................. 12
    4.1.7    Test Results ....................................................................................................................................... 13
    4.2      Conducted Emission Measurement .................................................................................................. 26
    4.2.1    Limits of Conducted Emission Measurement .................................................................................... 26
    4.2.2    Test Instruments ................................................................................................................................ 26
    4.2.3    Test Procedures................................................................................................................................. 27
    4.2.4    Deviation from Test Standard ............................................................................................................ 27
    4.2.5    Test Setup .......................................................................................................................................... 27
    4.2.6    EUT Operating Conditions................................................................................................................. 27
    4.2.7    Test Results ....................................................................................................................................... 28
5         Pictures of Test Arrangements .......................................................................................................... 32
Appendix – Information of the Testing Laboratories ................................................................................. 33




Report No.: RF190724C15                                              Page No. 2 / 33                                             Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
RF190724C15           Original release                                   Aug. 15, 2019




Report No.: RF190724C15                     Page No. 3 / 33       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: BOOST↑CHARGE™ Wireless Charging Stand Special Edition

              Brand: belkin

        Test Model: F7U094

    Sample Status: Engineering sample

          Applicant: Belkin International, Inc.

          Test Date: Jul. 25 ~ Jul. 30, 2019

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.209)
                          ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                               , Date:        Aug. 15, 2019
                                 Polly Chien / Specialist




     Approved by :                                                , Date:        Aug. 15, 2019
                             Bruce Chen / Project Engineer




Report No.: RF190724C15                         Page No. 4 / 33                       Report Format Version: 6.1.1


2     Summary of Test Results

                             47 CFR FCC Part 15, Subpart C (Section 15.209)
       FCC
                              Test Item                   Result                    Remarks
      Clause
                                                                     Meet the requirement of limit.
      15.207      AC Power Conducted Emission              Pass      Minimum passing margin is
                                                                     -10.24dB at 5.61618MHz.
                                                                     Meet the requirement of limit.
      15.209      Radiated Emission Test                   Pass      Minimum passing margin is
                                                                     -8.2dB at 59.06MHz

2.1    Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
EUT as specified in CISPR 16-4-2:
                                                                                     Expanded Uncertainty
                   Measurement                                 Frequency
                                                                                          (k=2) (±)
        Conducted Emissions at mains ports               150kHz ~ 30MHz                    2.94 dB
                                                          9kHz ~ 30MHz                     3.04 dB
         Radiated Emissions up to 1 GHz                  30MHz ~ 200MHz                    3.86 dB
                                                        200MHz ~ 1000MHz                   3.87 dB


2.2    Modification Record
There were no modifications required for compliance.




Report No.: RF190724C15                      Page No. 5 / 33                          Report Format Version: 6.1.1


3     General Information
3.1    General Description of EUT

 Product                            BOOST↑CHARGE™ Wireless Charging Stand Special Edition
 Brand                              belkin
 Test Model                         F7U094
 Sample Status                      Engineering sample
 Rating                             15Vdc (Adapter)
 Modulation Type                    FSK
 Operating Frequency                127.8 kHz
 Dimension for iPhone charging
                                    47.52cm2 (diameter = 77.8mm)
 coil
 Antenna Type                       Coil antenna
 Field Strength                     81.1dBuV/m
 Accessory Device                   Adapter
 Data Cable Supplied                NA
 Maximum Power Output for
                                    7.5W
 Phone charging coil
Note:
1. The EUT uses following adapter.
 Brand                          belkin
 Model                          2ADH023H NJ
 Input Power                    100-240Vac, 50/60Hz, 0.7A MAX
 Output Power                   15Vdc, 1.5A
 Power Line                     1.5m DC cable without core attached on adapter
2. The EUT has WPC (Wireless Power Consortium) technology.

3.2    Description of Test Modes
1 channel is provided to this EUT
             Channel                                              Freq. (kHz)
                  1                                                 127.8




Report No.: RF190724C15                         Page No. 6 / 33                  Report Format Version: 6.1.1


3.2.1       Test Mode Applicability and Tested Channel Detail
    EUT                     APPLICABLE TO
 CONFIGURE                                                                        DESCRIPTION
   MODE               RE<1G             PLC
        A                   √            -       Charging Mode (iPhone in the stand-up position)
        B                   √            √       Charging Mode (iPhone in the lie-down position)
        C                   √            √       Standby Mode
Where        RE<1G: Radiated Emission below 1GHz                         PLC: Power Line Conducted Emission


Note:
1. The EUT is designed to be positioned on the X-plane only.
2. “-” means no effect.
3. After the pretesting on radiated emission (30MHz to 1GHz) among mode A and B, mode B was found to be the worst case test mode.
   Therefore, radiated emission (30MHz to 1GHz) and conducted emission among mode B had been chosen for final test.


Radiated Emission Test (Below 1GHz):
     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
             EUT Configure Mode                         Available Channel                           Tested Channel
                  A, B, C                                       1                                          1


Power Line Conducted Emission Test:
    Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
     available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
             EUT Configure Mode                         Available Channel                           Tested Channel
                     B, C                                       1                                          1


Test Condition:
     Applicable To              Environmental Conditions                 Input Power                      Tested by

        RE<1G                      22 deg. C, 66% RH                     120Vac, 60Hz                     Adair Peng
            PLC                    25 deg. C, 75% RH                     120Vac, 60Hz                     Willy Cheng




Report No.: RF190724C15                                Page No. 7 / 33                               Report Format Version: 6.1.1


3.3     Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
 ID       Product         Brand        Model No.             Serial No.   FCC ID               Remarks
 A.       iPhone X        APPLE         A1901                    NA         NA        -


3.3.1    Configuration of System under Test
Charging Mode:
Test Mode A, B


                                                      iPhone X
                                                         (A)

            Adapter (EUT)                                EUT




Standby Mode:
Test Mode C




            Adapter (EUT)                                EUT




3.4     General Description of Applied Standards
The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:

FCC Part 15, Subpart C (15.209)
ANSI C63.10-2013

All test items have been performed and recorded as per the above standards.




Report No.: RF190724C15                            Page No. 8 / 33                   Report Format Version: 6.1.1


4       Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement
FOR FREQUENCY BELOW 30MHz

        Frequency                Field Strength (dBuV/m)                   Measurement Distance
          (MHz)               uV/m                      dBuV/m                   (meters)

      0.009 – 0.490       2400 / F (kHz)             48.52-13.80                   300

      0.490 – 1.705       24000 / F (kHz)            33.80-22.97                    30

      1.705 – 30.0               30                      29.54                      30

FOR FREQUENCY BETWEEN 30-1000MHz

            Frequency                         Class A (at 10m)                  Class B (at 3m)
              (MHz)                        uV/m                  dBuV/m     uV/m               dBuV/m

               30-88                        90                      39.1     100                 40.0

              88-216                        150                     43.5     150                 43.5

              216-960                       210                     46.4     200                 46.0

            Above 960                       300                     49.5     500                 54.0




Report No.: RF190724C15                           Page No. 9 / 33                  Report Format Version: 6.1.1


4.1.2   Test Instruments
  Description & Manufacturer         Model No.                    Serial No.     Cal. Date          Cal. Due
Test Receiver
                                       ESIB7                       100187      May 30, 2019      May 29, 2020
ROHDE & SCHWARZ
BILOG Antenna
                                    VULB9168                      9168-171     Nov. 22, 2018 Nov. 21, 2019
SCHWARZBECK
HORN Antenna
                                       9120D                         209       Nov. 25, 2018 Nov. 24, 2019
SCHWARZBECK
HORN Antenna
                                    BBHA 9170               BBHA9170241        Nov. 25, 2018 Nov. 24, 2019
SCHWARZBECK
Loop Antenna
                                     HLA 6121                      45745       Jul. 01, 2019     Jun. 30, 2020
TESEQ
Preamplifier
Agilent                                8447D                 2944A10738        Aug. 21, 2018 Aug. 20, 2019
(Below 1GHz)
Preamplifier
Agilent                                8449B                 3008A02465        Mar. 27, 2019     Mar. 26, 2020
(Above 1GHz)
RF signal cable                                             Cable-CH3-03
                                  SUCOFLEX 104                                 Aug. 21, 2018 Aug. 20, 2019
HUBER+SUHNER                                                 (223653/4)
RF signal cable                    SUCOFLEX
                                                            Cable-CH3-03
HUBER+SUHNER&                   104&EMC104-SM-S                                Aug. 21, 2018 Aug. 20, 2019
                                                          (309224+170907)
EMCI                                 M-8000
Software                          ADT_Radiated_
                                                                     NA             NA                 NA
BV ADT                             V7.6.15.9.5
Antenna Tower
                                     MA 4000                       013303           NA                 NA
inn-co GmbH
Antenna Tower Controller
                                       AT100                 AT93021702             NA                 NA
BV ADT
Turn Table
                                       TT100                 TT93021702             NA                 NA
BV ADT
Turn Table Controller
                                      SC100                  SC93021702             NA                 NA
BV ADT
Boresight Antenna Fixture             FBA-01                  FBA-SIP01             NA                 NA

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Chamber 3.




Report No.: RF190724C15                        Page No. 10 / 33                        Report Format Version: 6.1.1


4.1.3   Test Procedures
For Radiated emission below 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
    room. The table was rotated 360 degrees to determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
     measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
     from 0 degrees to 360 degrees to find the maximum reading.
e.   The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with Maximum
     Hold Mode.
Note:
1.   The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
     below 30MHz.

For Radiated emission above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for below 1GHz) / 1.5 meters (for above
    1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
    determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   The height of antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
     to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
     find the maximum reading.
e.   The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
     hold mode when the test frequency is below 1 GHz.
f.   The test-receiver system was set to peak and average detect function and specified bandwidth with
     maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
     average limit, measurement with the average detector is unnecessary.
Note:
1.   The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
     Quasi-peak detection (QP) at frequency below 1GHz.
2.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
     for Peak detection (PK) at frequency above 1GHz.
3.   The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is ≥ 1/T
     (Duty cycle < 98%) or 10Hz (Duty cycle ≥ 98%) for Average detection (AV) at frequency above 1GHz.
4.   All modes of operation were investigated and the worst-case emissions are reported.


4.1.4   Deviation from Test Standard

No deviation.



Report No.: RF190724C15                        Page No. 11 / 33                        Report Format Version: 6.1.1


4.1.5   Test Set Up
For Radiated emission below 30MHz

                EUT&                          3m
                                                                          Loop antenna
               Support Units

                                         Turn Table

                 80cm


                                              Ground Plane

                                           Test Receiver




For Radiated emission 30MHz to 1GHz
                                                               Ant. Tower
                                                                                      1-4m
                                                                                      Variable
              EUT&
                                                 3m
                                                 10m
              Support Units

                                         Turn Table

                 80cm


                                              Ground Plane

                                              Test Receiver




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions
Charging Mode:
Test Mode A, B
a. The EUT powered by adapter.
b. Put the iPhone X on the EUT (wireless charging) during the test.

Standby Mode:
Test Mode C
a. The EUT powered by adapter.




Report No.: RF190724C15                         Page No. 12 / 33                           Report Format Version: 6.1.1


4.1.7   Test Results
Below 30MHz Data: Charging Mode
Channel                   TX Channel 1                                             Average (AV)
                                                        Detector Function
Frequency Range           9 kHz ~ 30 MHz                                           Quasi-Peak (QP)

Test Mode                 A

              ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA PARALLEL AT 3M
                     Emission                                Antenna      Table         Raw          Correction
          Freq.                    Limit       Margin
No.                    Level                                  Height     Angle          Value         Factor
         (MHz)                   (dBuV/m)       (dB)
                     (dBuV/m)                                  (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.1278       73.9 AV      105.5        -31.6          1.00        293          54.8           19.1
 2       3.3747       36.5 QP      69.5         -33.0          1.00        335          16.5           20.0
 3       5.5985       37.0 QP      69.5         -32.5          1.00        319          16.7           20.3
 4      10.2865       33.9 QP      69.5         -35.6          1.00        213          12.2           21.7
 5      15.2149       34.7 QP      69.5         -34.8          1.00        321          12.8           21.9
 6      23.2085       37.4 QP      69.5         -32.1          1.00        13           15.3           22.1
 7      27.1151       34.8 QP      69.5         -34.7          1.00        70           12.6           22.2
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40




Report No.: RF190724C15                       Page No. 13 / 33                         Report Format Version: 6.1.1


Channel                   TX Channel 1                                             Average (AV)
                                                        Detector Function
Frequency Range           9 kHz ~ 30 MHz                                           Quasi-Peak (QP)

Test Mode                 A

          ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA PERPENDICULAR AT 3m
                     Emission                                Antenna      Table         Raw          Correction
          Freq.                    Limit       Margin
No.                    Level                                  Height     Angle          Value         Factor
         (MHz)                   (dBuV/m)       (dB)
                     (dBuV/m)                                  (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.1278       66.1 AV      105.5        -39.4          1.00         15          47.0           19.1
 2       3.4348       34.1 QP      69.5         -35.4          1.00        332          14.1           20.0
 3       6.8607       33.8 QP      69.5         -35.7          1.00        240          13.1           20.7
 4      12.9911       34.6 QP      69.5         -34.9          1.00        147          12.8           21.8
 5      17.4987       34.3 QP      69.5         -35.2          1.00        30           12.3           22.0
 6      23.2085       35.4 QP      69.5         -34.1          1.00        128          13.3           22.1
 7      28.4974       34.8 QP      69.5         -34.7          1.00        94           12.6           22.2
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40




Report No.: RF190724C15                       Page No. 14 / 33                         Report Format Version: 6.1.1


Channel                   TX Channel 1                                             Average (AV)
                                                        Detector Function
Frequency Range           9 kHz ~ 30 MHz                                           Quasi-Peak (QP)

Test Mode                 A

        ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA GROUND-PARALLEL AT 3m
                     Emission                                Antenna      Table         Raw          Correction
          Freq.                    Limit       Margin
No.                    Level                                  Height     Angle          Value         Factor
         (MHz)                   (dBuV/m)       (dB)
                     (dBuV/m)                                  (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.1278       71.1 AV      105.5        -34.4          1.00        277          52.0           19.1
 2       3.550        37.2 QP      69.5         -32.3          1.00        286          17.2           20.0
 3       5.5985       35.0 QP      69.5         -34.5          1.00        147          14.7           20.3
 4      10.0461       35.4 QP      69.5         -34.1          1.00        123          13.7           21.7
 5      15.3351       36.7 QP      69.5         -32.8          1.00        306          14.8           21.9
 6      20.3235       36.8 QP      69.5         -32.7          1.00        69           14.7           22.1
 7      24.1701       38.7 QP      69.5         -30.8          1.00        243          16.6           22.1
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40




Report No.: RF190724C15                       Page No. 15 / 33                         Report Format Version: 6.1.1


Channel                   TX Channel 1                                             Average (AV)
                                                        Detector Function
Frequency Range           9 kHz ~ 30 MHz                                           Quasi-Peak (QP)

Test Mode                 B

              ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA PARALLEL AT 3M
                     Emission                                Antenna      Table         Raw          Correction
          Freq.                    Limit       Margin
No.                    Level                                  Height     Angle          Value         Factor
         (MHz)                   (dBuV/m)       (dB)
                     (dBuV/m)                                  (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.1278       81.1 AV      105.5        -24.4          1.00        333          62.0           19.1
 2       2.7737       36.7 QP      69.5         -32.8          1.00        302          16.8           19.9
 3       5.3581       36.8 QP      69.5         -32.7          1.00        343          16.6           20.2
 4       7.5819       33.7 QP      69.5         -35.8          1.00        154          12.8           20.9
 5      12.4502       34.7 QP      69.5         -34.8          1.00        336          12.9           21.8
 6      17.4386       36.5 QP      69.5         -33.0          1.00        214          14.5           22.0
 7      20.3235       36.7 QP      69.5         -32.8          1.00        141          14.6           22.1
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40




Report No.: RF190724C15                       Page No. 16 / 33                         Report Format Version: 6.1.1


Channel                   TX Channel 1                                             Average (AV)
                                                        Detector Function
Frequency Range           9 kHz ~ 30 MHz                                           Quasi-Peak (QP)

Test Mode                 B

          ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA PERPENDICULAR AT 3m
                     Emission                                Antenna      Table         Raw          Correction
          Freq.                    Limit       Margin
No.                    Level                                  Height     Angle          Value         Factor
         (MHz)                   (dBuV/m)       (dB)
                     (dBuV/m)                                  (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.1278       74.3 AV      105.5        -31.2          1.00        115          55.2           19.1
 2       2.8338       35.4 QP      69.5         -34.1          1.00        27           15.5           19.9
 3       5.3581       34.7 QP      69.5         -34.8          1.00        192          14.5           20.2
 4      10.1663       34.1 QP      69.5         -35.4          1.00        173          12.4           21.7
 5      13.5921       34.4 QP      69.5         -35.1          1.00        337          12.6           21.8
 6      19.2417       34.4 QP      69.5         -35.1          1.00        80           12.3           22.1
 7      25.0716       36.5 QP      69.5         -33.0          1.00        170          14.4           22.1
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40




Report No.: RF190724C15                       Page No. 17 / 33                         Report Format Version: 6.1.1


Channel                   TX Channel 1                                             Average (AV)
                                                        Detector Function
Frequency Range           9 kHz ~ 30 MHz                                           Quasi-Peak (QP)

Test Mode                 B

        ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA GROUND-PARALLEL AT 3m
                     Emission                                Antenna      Table         Raw          Correction
          Freq.                    Limit       Margin
No.                    Level                                  Height     Angle          Value         Factor
         (MHz)                   (dBuV/m)       (dB)
                     (dBuV/m)                                  (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.1278       78.5 AV      105.5        -27.0          1.00         41          59.4           19.1
 2       2.7737       42.1 QP      69.5         -27.4          1.00        236          22.2           19.9
 3       5.0576       35.1 QP      69.5         -34.4          1.00        287          15.0           20.1
 4       9.2046       36.7 QP      69.5         -32.8          1.00         3           15.3           21.4
 5      13.3517       35.6 QP      69.5         -33.9          1.00        298          13.8           21.8
 6      21.2852       37.4 QP      69.5         -32.1          1.00        300          15.3           22.1
 7      25.0716       40.9 QP      69.5         -28.6          1.00        14           18.8           22.1
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40




Report No.: RF190724C15                       Page No. 18 / 33                         Report Format Version: 6.1.1


Standby Mode
Channel                   TX Channel 1                                             Average (AV)
                                                        Detector Function
Frequency Range           9 kHz ~ 30 MHz                                           Quasi-Peak (QP)

Test Mode                 C

              ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA PARALLEL AT 3m
                     Emission                                Antenna      Table         Raw          Correction
          Freq.                    Limit       Margin
No.                    Level                                  Height     Angle          Value         Factor
         (MHz)                   (dBuV/m)       (dB)
                     (dBuV/m)                                  (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.1278       69.3 AV      105.5        -36.2          1.00        354          50.2           19.1
 2       2.8338       36.1 QP      69.5         -33.4          1.00        102          16.2           19.9
 3       5.2379       38.3 QP      69.5         -31.2          1.00         10          18.1           20.2
 4       8.9642       34.0 QP      69.5         -35.5          1.00        198          12.7           21.3
 5      13.4719       34.6 QP      69.5         -34.9          1.00        114          12.8           21.8
 6      18.2200       35.1 QP      69.5         -34.4          1.00         23          13.1           22.0
 7      23.2085       36.9 QP      69.5         -32.6          1.00        352          14.8           22.1
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40




Report No.: RF190724C15                       Page No. 19 / 33                         Report Format Version: 6.1.1


Channel                   TX Channel 1                                             Average (AV)
                                                        Detector Function
Frequency Range           9 kHz ~ 30 MHz                                           Quasi-Peak (QP)

Test Mode                 C

          ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA PERPENDICULAR AT 3m
                     Emission                                Antenna      Table         Raw          Correction
          Freq.                    Limit       Margin
No.                    Level                                  Height     Angle          Value         Factor
         (MHz)                   (dBuV/m)       (dB)
                     (dBuV/m)                                  (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.1278       65.5 AV      105.5        -40.0          1.00        273          46.4           19.1
 2       2.8338       38.1 QP      69.5         -31.4          1.00        187          18.2           19.9
 3       5.2379       38.5 QP      69.5         -31.0          1.00        56           18.3           20.2
 4      10.1062       35.0 QP      69.5         -34.5          1.00        322          13.3           21.7
 5      11.9693       35.7 QP      69.5         -33.8          1.00        182          13.9           21.8
 6      16.2366       34.5 QP      69.5         -35.0          1.00        18           12.6           21.9
 7      20.3235       36.0 QP      69.5         -33.5          1.00        12           13.9           22.1
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40




Report No.: RF190724C15                       Page No. 20 / 33                         Report Format Version: 6.1.1


Channel                   TX Channel 1                                             Average (AV)
                                                        Detector Function
Frequency Range           9 kHz ~ 30 MHz                                           Quasi-Peak (QP)

Test Mode                 C

        ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA GROUND-PARALLEL AT 3m
                     Emission                                Antenna      Table         Raw          Correction
          Freq.                    Limit       Margin
No.                    Level                                  Height     Angle          Value         Factor
         (MHz)                   (dBuV/m)       (dB)
                     (dBuV/m)                                  (m)      (Degree)       (dBuV)         (dB/m)
 1      *0.1278       63.0 AV      105.5        -42.5          1.00         3           43.9           19.1
 2       2.7737       42.1 QP      69.5         -27.4          1.00        27           22.2           19.9
 3       5.4783       36.0 QP      69.5         -33.5          1.00        175          15.8           20.2
 4      11.1279       34.7 QP      69.5         -34.8          1.00        73           13.0           21.7
 5      15.3952       37.0 QP      69.5         -32.5          1.00        238          15.1           21.9
 6      20.3836       37.6 QP      69.5         -31.9          1.00         9           15.5           22.1
 7      23.9898       40.0 QP      69.5         -29.5          1.00        63           17.9           22.1
Remarks:
            1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission Level – Limit value
            5. “ * “: Fundamental frequency.
            6. Loop antenna was used for all radiated emission below 30MHz.
            7. Limit @3m=Limit@300m+40log(300 / 3)=Limit@300m+80
            8. Limit @3m=Limit@30m+40log(30 / 3)=Limit@30m+40




Report No.: RF190724C15                       Page No. 21 / 33                         Report Format Version: 6.1.1


Below 1GHz Data:
Charging Mode
Channel                   TX Channel 1
                                                           Detector Function          Quasi-Peak (QP)
Frequency Range           30MHz ~ 1GHz

Test Mode                 B

                                Antenna Polarity & Test Distance: Horizontal At 3m
                     Emission                                  Antenna       Table         Raw          Correction
          Freq.                       Limit       Margin
No.                    Level                                    Height      Angle          Value         Factor
         (MHz)                      (dBuV/m)       (dB)
                     (dBuV/m)                                     (m)      (Degree)       (dBuV)         (dB/m)
 1      57.12         26.9 QP         40.0        -13.1         2.00 H        268          37.0           -10.1
 2      131.00        30.5 QP         43.5        -13.0         1.50 H        71           41.0           -10.5
 3      152.39        32.9 QP         43.5        -10.6         2.00 H        78           42.1            -9.2
 4      179.61        30.6 QP         43.5        -12.9         1.50 H        74           40.8           -10.2
 5      307.93        30.6 QP         46.0        -15.4         1.01 H        236          37.7            -7.1
 6      455.70        27.2 QP         46.0        -18.8         2.00 H        120          31.6            -4.4
Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit.
           4. Margin value = Emission Level – Limit value




Report No.: RF190724C15                         Page No. 22 / 33                          Report Format Version: 6.1.1


Channel                   TX Channel 1
                                                          Detector Function          Quasi-Peak (QP)
Frequency Range           30MHz ~ 1GHz

Test Mode                 B


                                Antenna Polarity & Test Distance: Vertical At 3m
                     Emission                                 Antenna       Table         Raw          Correction
          Freq.                      Limit       Margin
No.                    Level                                   Height      Angle          Value         Factor
         (MHz)                     (dBuV/m)       (dB)
                     (dBuV/m)                                   (m)       (Degree)       (dBuV)         (dB/m)
 1      37.68         30.3 QP        40.0         -9.7         1.00 V        329          41.0           -10.7
 2      59.06         31.8 QP        40.0         -8.2         1.00 V        322          41.9           -10.1
 3      150.45        24.4 QP        43.5        -19.1         1.00 V         0           33.5            -9.1
 4      294.32        27.3 QP        46.0        -18.7         1.50 V        183          34.9            -7.6
 5      473.20        28.3 QP        46.0        -17.7         1.00 V        84           32.4            -4.1
 6      642.35        27.1 QP        46.0        -18.9         1.50 V         7           27.7            -0.6
Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit.
           4. Margin value = Emission Level – Limit value




Report No.: RF190724C15                        Page No. 23 / 33                          Report Format Version: 6.1.1


Standby Mode
Channel                   TX Channel 1
                                                           Detector Function          Quasi-Peak (QP)
Frequency Range           30MHz ~ 1GHz

Test Mode                 C

                                Antenna Polarity & Test Distance: Horizontal At 3m
                     Emission                                  Antenna       Table         Raw          Correction
          Freq.                       Limit       Margin
No.                    Level                                    Height      Angle          Value         Factor
         (MHz)                      (dBuV/m)       (dB)
                     (dBuV/m)                                     (m)      (Degree)       (dBuV)         (dB/m)
 1      57.12         22.3 QP         40.0        -17.7         1.50 H        62           32.4           -10.1
 2      152.39        29.1 QP         43.5        -14.4         1.00 H        250          38.3            -9.2
 3      193.22        22.9 QP         43.5        -20.6         2.00 H        68           34.1           -11.2
 4      290.43        28.6 QP         46.0        -17.4         1.00 H        135          36.3            -7.7
 5      339.04        26.4 QP         46.0        -19.6         1.50 H        81           33.2            -6.8
 6      436.26        24.6 QP         46.0        -21.4         1.00 H        290          29.1            -4.5
Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit.
           4. Margin value = Emission Level – Limit value




Report No.: RF190724C15                         Page No. 24 / 33                          Report Format Version: 6.1.1


Channel                   TX Channel 1
                                                          Detector Function          Quasi-Peak (QP)
Frequency Range           30MHz ~ 1GHz

Test Mode                 C


                                Antenna Polarity & Test Distance: Vertical At 3m
                     Emission                                 Antenna       Table         Raw          Correction
          Freq.                      Limit       Margin
No.                    Level                                   Height      Angle          Value         Factor
         (MHz)                     (dBuV/m)       (dB)
                     (dBuV/m)                                    (m)      (Degree)       (dBuV)         (dB/m)
 1      51.29         22.7 QP        40.0        -17.3         1.50 V         5           32.4            -9.7
 2      154.33        21.5 QP        43.5        -22.0         1.00 V        120          30.5            -9.0
 3      290.43        25.8 QP        46.0        -20.2         1.50 V        169          33.5            -7.7
 4      432.37        24.9 QP        46.0        -21.1         1.00 V        247          29.4            -4.5
 5      582.08        25.6 QP        46.0        -20.4         2.00 V        240          27.3            -1.7
 6      689.01        27.5 QP        46.0        -18.5         1.00 V        117          27.4             0.1
Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit.
           4. Margin value = Emission Level – Limit value




Report No.: RF190724C15                        Page No. 25 / 33                          Report Format Version: 6.1.1


4.2     Conducted Emission Measurement
4.2.1    Limits of Conducted Emission Measurement
                                                             Conducted Limit (dBuV)
        Frequency (MHz)
                                                Quasi-peak                              Average
           0.15 - 0.5                              66 - 56                               56 - 46
           0.50 - 5.0                                56                                     46
           5.0 - 30.0                                60                                     50
Note: 1. The lower limit shall apply at the transition frequencies.
      2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.

4.2.2    Test Instruments

   Description & Manufacturer           Model No.                 Serial No.     Cal. Date          Cal. Due
Test Receiver
                                           ESCI                    100613      Dec. 10, 2018 Dec. 09, 2019
ROHDE & SCHWARZ
RF signal cable
                                          5D-FB              Cable-cond1-01    Sep. 05, 2018 Sep. 04, 2019
Woken
LISN
ROHDE & SCHWARZ                          ENV216                    101826      Feb. 21, 2019 Feb. 20, 2020
(EUT)
LISN
ROHDE & SCHWARZ                         ESH3-Z5                    100311      Aug. 19, 2018 Aug. 18, 2019
(Peripheral)
Software                             BV ADT_Cond_
                                                                     NA             NA                 NA
ADT                                     V7.3.7.4

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Shielded Room 1.
      3. The VCCI Site Registration No. is C-12040.




Report No.: RF190724C15                        Page No. 26 / 33                        Report Format Version: 6.1.1


4.2.3   Test Procedures
a.   The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
     connected to the power mains through a line impedance stabilization network (LISN). Other support units
     were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50uH of
     coupling impedance for the measuring instrument.
b.   Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c.   The frequency range from 150kHz to 30MHz was searched. Emission levels under (Limit - 20dB) were
     not recorded.
NOTE: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi-peak detection (QP)
      and average detection (AV) at frequency 0.15MHz-30MHz.

4.2.4   Deviation from Test Standard
No deviation.

4.2.5   Test Setup
                                   Vertical Ground
                                   Reference Plane                               Test Receiver


                                   EUT
                      40cm




                                                        80cm
                      LISN



                                                                   Horizontal Ground
                                                                    Reference Plane

                          Note: 1.Support units were connected to second LISN.




For the actual test configuration, please refer to the attached file (Test Setup Photo).

4.2.6   EUT Operating Conditions
Same as 4.1.6.




Report No.: RF190724C15                         Page No. 27 / 33                           Report Format Version: 6.1.1


4.2.7   Test Results
Charging Mode
                                                                                    Quasi-Peak (QP) /
Phase                          Line (L)                     Detector Function
                                                                                    Average (AV)
Test Mode                      B


                           Corr.    Reading Value     Emission Level            Limit              Margin
           Freq.
 No                       Factor       [dB (uV)]         [dB (uV)]           [dB (uV)]              (dB)
           [MHz]           (dB)      Q.P.     AV.      Q.P.     AV.        Q.P.       AV.      Q.P.      AV.
  1       0.15000          9.84     43.45    27.05    53.29    36.89      66.00     56.00     -12.71 -19.11
  2       0.15782          9.84     40.35    25.24    50.19    35.08      65.58     55.58     -15.39 -20.50
  3       0.25932          9.86     29.58    21.18    39.44    31.04      61.45     51.45     -22.01 -20.41
  4       0.44325          9.88     30.35    24.10    40.23    33.98      57.00     47.00     -16.77 -13.02
  5       0.63856          9.90     26.17    23.28    36.07    33.18      56.00     46.00     -19.93 -12.82
  6       5.61618         10.06     31.85    29.70    41.91    39.76      60.00     50.00     -18.09 -10.24
Remarks:
               1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. The emission levels of other frequencies were very low against the limit.
               3. Margin value = Emission level - Limit value
               4. Correction factor = Insertion loss + Cable loss
               5. Emission Level = Correction Factor + Reading Value.




Report No.: RF190724C15                        Page No. 28 / 33                         Report Format Version: 6.1.1


                                                                                    Quasi-Peak (QP) /
Phase                          Neutral (N)                  Detector Function
                                                                                    Average (AV)
Test Mode                      B


                           Corr.   Reading Value      Emission Level            Limit              Margin
           Freq.
 No                       Factor      [dB (uV)]          [dB (uV)]           [dB (uV)]              (dB)
           [MHz]           (dB)     Q.P.     AV.       Q.P.     AV.        Q.P.       AV.      Q.P.      AV.
  1       0.15000          9.82    44.30    27.29     54.12    37.11      66.00     56.00     -11.88 -18.89
  2       0.20084          9.84    34.38    20.56     44.22    30.40      63.58     53.58     -19.36 -23.18
  3       0.44325          9.87    27.42    21.02     37.29    30.89      57.00     47.00     -19.71 -16.11
  4       0.63856          9.87    25.16    23.09     35.03    32.96      56.00     46.00     -20.97 -13.04
  5       5.62009         10.04    26.53    23.78     36.57    33.82      60.00     50.00     -23.43 -16.18
  6       8.05602         10.11    22.45    17.45     32.56    27.56      60.00     50.00     -27.44 -22.44
Remarks:
               1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. The emission levels of other frequencies were very low against the limit.
               3. Margin value = Emission level - Limit value
               4. Correction factor = Insertion loss + Cable loss
               5. Emission Level = Correction Factor + Reading Value.




Report No.: RF190724C15                        Page No. 29 / 33                         Report Format Version: 6.1.1


Standby Mode
                                                                                    Quasi-Peak (QP) /
Phase                          Line (L)                     Detector Function
                                                                                    Average (AV)
Test Mode                      C


                           Corr.    Reading Value     Emission Level            Limit              Margin
           Freq.
 No                       Factor       [dB (uV)]         [dB (uV)]           [dB (uV)]              (dB)
           [MHz]           (dB)      Q.P.     AV.      Q.P.     AV.        Q.P.       AV.      Q.P.      AV.
  1       0.16564          9.84     28.93     4.57    38.77    14.41      65.18     55.18     -26.41 -40.77
  2       0.24384          9.86     20.12     2.20    29.98    12.06      61.96     51.96     -31.98 -39.90
  3       0.44325          9.88     25.51     9.34    35.39    19.22      57.00     47.00     -21.61 -27.78
  4       1.40395          9.93     12.24     4.18    22.17    14.11      56.00     46.00     -33.83 -31.89
  5       2.93783          9.98     14.53     5.63    24.51    15.61      56.00     46.00     -31.49 -30.39
  6       4.72861         10.04     19.32     9.62    29.36    19.66      56.00     46.00     -26.64 -26.34
Remarks:
               1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. The emission levels of other frequencies were very low against the limit.
               3. Margin value = Emission level - Limit value
               4. Correction factor = Insertion loss + Cable loss
               5. Emission Level = Correction Factor + Reading Value.




Report No.: RF190724C15                        Page No. 30 / 33                         Report Format Version: 6.1.1


                                                                                    Quasi-Peak (QP) /
Phase                          Neutral (N)                  Detector Function
                                                                                    Average (AV)
Test Mode                      C


                           Corr.   Reading Value      Emission Level            Limit              Margin
           Freq.
 No                       Factor      [dB (uV)]          [dB (uV)]           [dB (uV)]              (dB)
           [MHz]           (dB)     Q.P.     AV.       Q.P.     AV.        Q.P.       AV.      Q.P.      AV.
  1       0.15802          9.82    30.87     9.56     40.69    19.38      65.57     55.57     -24.88 -36.19
  2       0.18910          9.84    25.72     6.04     35.56    15.88      64.08     54.08     -28.52 -38.20
  3       0.43579          9.87    25.24     8.85     35.11    18.72      57.14     47.14     -22.03 -28.42
  4       3.44613          9.98    14.37     5.59     24.35    15.57      56.00     46.00     -31.65 -30.43
  5       5.36203         10.04    28.39    20.00     38.43    30.04      60.00     50.00     -21.57 -19.96
  6       8.13813         10.11    16.12     0.71     26.23    10.82      60.00     50.00     -33.77 -39.18
Remarks:
               1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. The emission levels of other frequencies were very low against the limit.
               3. Margin value = Emission level - Limit value
               4. Correction factor = Insertion loss + Cable loss
               5. Emission Level = Correction Factor + Reading Value.




Report No.: RF190724C15                        Page No. 31 / 33                         Report Format Version: 6.1.1


5     Pictures of Test Arrangements
Please refer to the attached file (Test Setup Photo).




Report No.: RF190724C15                        Page No. 32 / 33   Report Format Version: 6.1.1


Appendix – Information of the Testing Laboratories
We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited and approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lin Kou EMC/RF Lab                                     Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-6668565
Fax: 886-2-26051924                                    Fax: 886-3-6668323

Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF190724C15                        Page No. 33 / 33                 Report Format Version: 6.1.1



Document Created: 2019-08-27 19:03:00
Document Modified: 2019-08-27 19:03:00

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC