Attestation (RF Exp Require KDB 680106)

FCC ID: K7SF7U094

Attestation Statements

Download: PDF
FCCID_4414487

Applicant: Belkin International, Inc.
FCC ID: K7SF7U094
                        RF Exposure Requirements ( FCC KDB 680106 D01 V03)
Requirements                                             Statements
(a) Power transfer frequency is less that 1 MHz          The resonator system shall operate at
                                                         127.7KHz
(b) Output power from each primary coil is less than     Maximum surface coupling area is 47.52 cm2
15 watts                                                 Max output Power for charging coil: 7.5W


(c) The transfer system includes only single primary     Product uses two overlapping smaller coils to
and secondary coils. This includes charging systems      form a fixed charging/powering zone which
that may have multiple primary coils and clients that    allow wireless power transfer to take place
are able to detect and allow coupling only between       between this zone and a single client device
individual pairs of coils
(d) Client device is inserted in or placed directly in    Client device is placed directly in contact
contact with the transmitter                              with the transmitter


(e) Mobile exposure conditions only (portable            It’s mobile device, and provided RF exposure
exposure conditions are not covered by this              report to evaluate
exclusion).
(f) The aggregate H-field strengths at 15 cm             Please refer to RF Exposure Report.
surrounding the device and 20 cm above the top
surface from all simultaneous transmitting coils are
demonstrated to be less than 50% of the MPE limit.




Rajesh Karki
Manager, Regulatory Compliance
Belkin International, Inc.
Tel: 310-751-2817
E-mail: rajesh.karki@belkin.com



Document Created: 2019-07-17 14:46:33
Document Modified: 2019-07-17 14:46:33