RF Exposure Info (MPE)_rev

FCC ID: K7SF7U083

RF Exposure Info

Download: PDF
FCCID_4189585

                                                     RF Exposure Test Report

                       Report No.: SA190107D07

                             FCC ID: K7SF7U083

                       Test Model: F7U083

                 Received Date: Jan. 7, 2019

                         Test Date: Jan. 28, 2019

                     Issued Date: Feb. 11, 2019


                         Applicant: Belkin International., Inc

                          Address: 12045 East Waterfront Drive, Playa Vista, CA 90094


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
         FCC Registration /
       Designation Number: 198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by any government agencies.




Report No.: SA190107D07                                              Page No. 1 / 13                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Report Issue History Record .......................................................................................................................... 3
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         General Information .............................................................................................................................. 5
    2.1      General Description of EUT ................................................................................................................ 5
3         RF Exposure .......................................................................................................................................... 6
    3.1      Description of Support Units ............................................................................................................... 6
    3.1.1    Configuration of System Under Test.................................................................................................... 6
    3.2      Test Setup ........................................................................................................................................... 7
    3.3      Test Instruments .................................................................................................................................. 7
    3.4      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 8
    3.5      Test Point Description ......................................................................................................................... 8
4         Calculation Result Of Maximum Conducted Power .......................................................................... 9
5         Photographs of the Test Configuration ............................................................................................ 13




Report No.: SA190107D07                                              Page No. 2 / 13                                             Report Format Version: 6.1.1


                                         Report Issue History Record


Issue No.             Description                                             Date Issued
SA190107D07           Original release                                        Feb. 11, 2019


                                           Release Control Record


Issue No.             Description                                             Date Issued
SA190107D07           Original release                                        Feb. 11, 2019




Report No.: SA190107D07                        Page No. 3 / 13         Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: BOOST↑UP™ Wireless Charging Stand 10W

              Brand: belkin

        Test Model: F7U083

    Sample Status: Engineering sample

          Applicant: Belkin International., Inc

          Test Date: Jan. 28, 2019

         Standards: FCC Part 1 (Section 1.1307(b), 1.1310)



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                     , Date:          Feb. 11, 2019
                            Jessica Cheng / Senior Specialist




     Approved by :                                                     , Date:          Feb. 11, 2019
                          Rex Lai / Associate Technical Manager




Report No.: SA190107D07                       Page No. 4 / 13                         Report Format Version: 6.1.1


2     General Information
2.1    General Description of EUT

 Product                        BOOST↑UP™ Wireless Charging Stand 10W
 Brand                          belkin
 Test Model                     F7U083
 Sample Status                  Engineering sample
                                Input: 5Vdc, 2A, Output: 5W
 Rating
                                Input: 9Vdc, 2A / 12Vdc, 1.5A Output: 10W
 Modulation Type                FSK
 Operating Frequency            111-148kHz
 Antenna Type                   Coil antenna
 Field Strength                 85.06dBuV/m
 Dimensions                     18.76 cm2, 39.5mm x 47.5mm (rectangle)
 Accessory Device               Adapter
 Data Cable Supplied            1.2m shielded USB cable
 Maximum Power Output from
                                10W
 the Charging Coil
Note:
1. The EUT is a wireless inductive charging coil.
2. The EUT has two configuration could be chosen as the following.
    Model                                 Configuration                              Difference
                    Wireless charging pad + USB cable + AC power supply
   F7U083                                                                       Marketing purpose
                              Wireless charging pad + USB cable
3. The EUT consumes power from a switching power adapter, as the following:
        Brand                 Model                                   Specification
                                              Input: 100-240Vac, 50/60Hz, 0.8A (AC 2 Pin)
                                              Output: +3.6-6Vdc, 2A
        belkin         DSA-18QFB FUS A
                                                      +6-9Vdc, 2A
                                                      +9-12Vdc, 1.5A




Report No.: SA190107D07                   Page No. 5 / 13                      Report Format Version: 6.1.1


3        RF Exposure
3.1       Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
    ID       Product                 Brand                Model No.           Serial No.         FCC ID               Remarks
                                                                                                                  Supplied by client
    A.         Load                   N/A                    N/A                 N/A               N/A
                                                                                                                   (10W max load)
Note: All power cords of the above support units are non-shielded (1.8m).


    ID     Descriptions               Qty.               Length (m)       Shielding (Yes/No)   Cores (Qty.)           Remarks
    1.      USB cable                   1                    1.2                  Y                 0             Supplied by client
Note: The core(s) is(are) originally attached to the cable(s).




3.1.1      Configuration of System Under Test



For Charging Mode with Load & Charging Mode with 3mm gap:



                                                                   Load (A)


                                         1
              Adapter (EUT)                     USB                 EUT
                  120Vac




For Standby Mode:




                                         1
            Adapter (EUT)                       USB                 EUT
                  120Vac




Report No.: SA190107D07                                     Page No. 6 / 13                              Report Format Version: 6.1.1


3.2     Test Setup




                                                 15 cm / 20cm




                                                                              EUT

                      Field Probe




Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm or
     20 cm measured from the center of the probe(s) to the edge of the device.

3.3     Test Instruments

       Description         Brand     Model No.     Frequency Range Calibrated Date Calibrated Until
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018      Mar. 27, 2020
       Meter
   Magnetic Field
                          NARDA       ELT-400          1 – 400kHz       Apr. 12, 2018     Apr. 11, 2020
      Meter
  Magnetic Probe          NARDA       HF-3061       300kHz – 30MHz      Apr. 16, 2018     Apr. 15, 2020
  Magnetic Probe          NARDA       HF-0191        27 – 1000MHz       Apr. 17, 2018     Apr. 16, 2020
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018      Mar. 27, 2020
       Meter
Electric Field Meter COMBINOVA        EFM 200        5Hz – 400kHz       Dec. 6, 2017      Dec. 5, 2019
      E-Field Probe       NARDA       EF-0391       100kHz – 3GHz      Mar. 28, 2018      Mar. 27, 2020
      E-Field Probe       NARDA       EF-6091      100MHz – 60GHz        Mar. 29, 2018  Mar. 28, 2020
NOTE: 1. The calibration interval of the above test instruments is 12/24 months and the
          calibrations are traceable to NML/ROC and NIST/USA.
      2. The test was performed in Chia Pau RF Chamber




Report No.: SA190107D07                      Page No. 7 / 13                         Report Format Version: 6.1.1


3.4    Limits for Maximum Permissible Exposure (MPE)
§ 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of
  human exposure to radiofrequency(RF) radiation as specified in § 1.1307(b), except in the case of portable
  devices which shall be evaluated according to the provisions of § 2.1093 of this chapter.




680106 D01 RF Exposure Wireless Charging App v03
The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all
simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

3.5    Test Point Description



                          Z-axis (Above)
                                       Top




      Left                                       Right




                 Bottom




Report No.: SA190107D07                      Page No. 8 / 13                        Report Format Version: 6.1.1


4      Calculation Result Of Maximum Conducted Power
Charging Mode with 10% Load
                                           E-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side             Left           Right                 Top          Bottom               Z-axis
    Max E-field (V/m)      0.8200         0.6600                0.7500        0.5400               0.4100
       Limit (V/m)          614             614                  614           614                   614
      Margin (V/m)        -613.1800     -613.3400              -613.2500    -613.4600            -613.5900
    50 % Limit (V/m)        307             307                  307           307                   307
50 % Margin (V/m)         -306.1800     -306.3400              -306.2500    -306.4600            -306.5900

                                           H-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side              Left           Right                Top          Bottom               Z-axis
    Max H-field (uT)        0.1490         0.1280               0.1360        0.2030               0.1180
    Max H-field (A/m)       0.1192         0.1024               0.1088        0.1624               0.0944
       Limit (A/m)           1.63           1.63                 1.63          1.63                 1.63
      Margin (A/m)         -1.5108         -1.5276              -1.5212      -1.4676              -1.5356
    50 % Limit (A/m)        0.815           0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6958            -0.7126           -0.7062          -0.6526           -0.7206
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.

Charging Mode with 50% Load
                                           E-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side              Left           Right                Top          Bottom               Z-axis
    Max E-field (V/m)       1.8400         1.2000               1.3200        0.9100               0.5500
       Limit (V/m)           614            614                  614           614                   614
      Margin (V/m)        -612.1600      -612.8000             -612.6800    -613.0900            -613.4500
    50 % Limit (V/m)         307            307                  307           307                   307
50 % Margin (V/m)         -305.1600      -305.8000             -305.6800    -306.0900            -306.4500

                                           H-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side              Left           Right                Top          Bottom               Z-axis
    Max H-field (uT)        0.1560         0.1380               0.1520        0.2610               0.1250
    Max H-field (A/m)       0.1248         0.1104               0.1216        0.2088               0.1000
       Limit (A/m)           1.63           1.63                 1.63          1.63                 1.63
      Margin (A/m)         -1.5052         -1.5196              -1.5084      -1.4212              -1.5300
    50 % Limit (A/m)        0.815           0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6902            -0.7046           -0.6934          -0.6062           -0.7150
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190107D07                      Page No. 9 / 13                          Report Format Version: 6.1.1


Charging Mode with Full Load
                                           E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         1.9700          1.3600               1.4500        1.0900               0.6900
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -612.0300      -612.6400          -612.5500       -612.9100            -613.3100
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -305.0300      -305.6400          -305.5500       -305.9100            -306.3100

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.1670          0.2020               0.2820        0.3430               0.1330
 Max H-field (A/m)         0.1336          0.1616               0.2256        0.2744               0.1064
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.4964         -1.4684              -1.4044      -1.3556              -1.5236
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.6814            -0.6534           -0.5894          -0.5406           -0.7086
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.

Charging Mode with 3mm gap 10% Load
                                           E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         0.8900          0.7100               0.7900        0.6100               0.4800
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -613.1100      -613.2900          -613.2100       -613.3900            -613.5200
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -306.1100      -306.2900          -306.2100       -306.3900            -306.5200

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.1520          0.1360               0.1420        0.2150               0.1480
 Max H-field (A/m)         0.1216          0.1088               0.1136        0.1720               0.1184
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.5084         -1.5212              -1.5164      -1.4580              -1.5116
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.6934            -0.7062           -0.7014          -0.6430           -0.6966
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.




Report No.: SA190107D07                      Page No. 10 / 13                         Report Format Version: 6.1.1


Charging Mode with 3mm gap 50% Load
                                           E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.9600          1.3200                1.4400       1.0500               0.6300
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.0400      -612.6800              -612.5600   -612.9500            -613.3700
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.0400      -305.6800              -305.5600   -305.9500            -306.3700

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1630          0.1410                0.1590       0.2710               0.1340
 Max H-field (A/m)         0.1304          0.1128                0.1272       0.2168               0.1072
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4996         -1.5172               -1.5028     -1.4132              -1.5228
  50 % Limit (A/m)         0.815            0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.6846            -0.7022           -0.6878          -0.5982           -0.7078
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with 3mm gap Full Load
                                           E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         2.0100          1.4700                1.5200       1.1100               0.7800
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -611.9900      -612.5300              -612.4800   -612.8900            -613.2200
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -304.9900      -305.5300              -305.4800   -305.8900            -306.2200

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1740          0.2260                0.2940       0.3580               0.1480
 Max H-field (A/m)         0.1392          0.1808                0.2352       0.2864               0.1184
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4908         -1.4492               -1.3948     -1.3436              -1.5116
  50 % Limit (A/m)         0.815            0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.6758            -0.6342           -0.5798          -0.5286           -0.6966
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.



Report No.: SA190107D07                      Page No. 11 / 13                         Report Format Version: 6.1.1


Standby Mode
                                           E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         0.2100          0.1900               0.2100        0.2300               0.1400
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -613.7900      -613.8100          -613.7900       -613.7700            -613.8600
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -306.7900      -306.8100          -306.7900       -306.7700            -306.8600

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.1010          0.1000               0.1340        0.1120               0.1070
 Max H-field (A/m)         0.0808          0.0800               0.1072        0.0896               0.0856
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.5492         -1.5500              -1.5228      -1.5404              -1.5444
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.7342            -0.7350           -0.7078          -0.7254           -0.7294
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.




Report No.: SA190107D07                      Page No. 12 / 13                         Report Format Version: 6.1.1


5    Photographs of the Test Configuration

Please refer to the attached file (Test Setup Photo).



--- END ---