RF Exposure Info (MPE)_rev

FCC ID: K7SF7U082

RF Exposure Info

Download: PDF
FCCID_4189638

                                                     RF Exposure Test Report

                       Report No.: SA190107D06

                             FCC ID: K7SF7U082

                       Test Model: F7U082

                   Series Model: F7U088

                 Received Date: Jan. 7, 2019

                         Test Date: Jan. 25, 2019

                     Issued Date: Feb. 11, 2019


                         Applicant: Belkin International., Inc

                           Address: 12045 East Waterfront Drive, Playa Vista, CA. 90094, USA


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
         FCC Registration /
       Designation Number: 198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by any government agencies.

Report No.: SA190107D06                                               Page No. 1 / 13                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Report Issue History Record .......................................................................................................................... 3
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         General Information .............................................................................................................................. 5
    2.1      General Description of EUT ................................................................................................................ 5
3         RF Exposure .......................................................................................................................................... 6
    3.1      Description of Support Units ............................................................................................................... 6
    3.1.1    Configuration of System Under Test.................................................................................................... 6
    3.2      Test Setup ........................................................................................................................................... 7
    3.3      Test Instruments .................................................................................................................................. 7
    3.4      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 8
    3.5      Test Point Description ......................................................................................................................... 8
4         Calculation Result of Maximum Conducted Power........................................................................... 9
5         Photographs of the Test Configuration ............................................................................................ 13




Report No.: SA190107D06                                              Page No. 2 / 13                                             Report Format Version: 6.1.1


                                          Report Issue History Record

Issue No.             Description                                              Date Issued
SA190107D06           Original release.                                        Feb. 11, 2019




                                            Release Control Record


Issue No.             Description                                              Date Issued
SA190107D06           Original release                                         Feb. 11, 2019




Report No.: SA190107D06                         Page No. 3 / 13         Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: BOOST↑UP™ Wireless Charging Pad 10W

              Brand: belkin

        Test Model: F7U082

      Series Model: F7U088

    Sample Status: Engineering sample

          Applicant: Belkin International., Inc

          Test Date: Jan. 25, 2019

         Standards: FCC Part 1 (Section 1.1307(b), 1.1310)



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                         , Date:        Feb. 11, 2019
                                   Celia Chen / Supervisor




    Approved by :                                                          , Date:        Feb. 11, 2019
                           Rex Lai / Associate Technical Manager




Report No.: SA190107D06                       Page No. 4 / 13                         Report Format Version: 6.1.1


2     General Information
2.1    General Description of EUT

 Product                          BOOST↑UP™ Wireless Charging Pad 10W
 Brand                            belkin
 Test Model                       F7U082
 Series Model                     F7U088
 Model Difference                 Refer to table as below
 Sample Status                    Engineering sample
                                  Input: 5Vdc, 2A, Output: 5W
 Rating                           Input: 9Vdc, 2A / 12Vdc, 1.5A Output: 10W
                                  From adapter
 Modulation Type                  FSK
 Operating Frequency              111-148kHz
 Antenna Type                     Coil antenna
 Field Strength                   79.76dBuV/m
 Dimensions                       17.35cm2 (diameter = 47mm)
 Accessory Device                 Adapter
 Data Cable Supplied              1.3m shielded USB cable
 Maximum Power Output from
                                  10W
 the Charging Coil
Note:
1. The EUT is a wireless inductive charging coil.
2. The EUT has two configuration could be chosen as the following.
    Model                                 Configuration                                  Difference
   F7U082           Wireless charging pad + USB cable + AC power supply
                                                                                    Marketing purpose
   F7U088                     Wireless charging pad + USB cable
3. The EUT consumes power from a switching power adapter, as the following:
        Brand                 Model                                   Specification
                                              Input: 100-240Vac, 50/60Hz, 0.8A (AC 2 Pin)
                                              Output: +3.6-6Vdc, 2A
        belkin         DSA-18QFB FUS A
                                                      +6-9Vdc, 2A
                                                      +9-12Vdc, 1.5A
4. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: SA190107D06                      Page No. 5 / 13                       Report Format Version: 6.1.1


3        RF Exposure
3.1       Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
    ID       Product                 Brand                Model No.           Serial No.         FCC ID               Remarks
                                                                                                                  Supplied by client
    A.         Load                   N/A                    N/A                 N/A               N/A
                                                                                                                   (10W max load)
Note: All power cords of the above support units are non-shielded (1.8m).


    ID     Descriptions               Qty.               Length (m)       Shielding (Yes/No)   Cores (Qty.)           Remarks
    1.      USB cable                   1                    1.3                  Y                 0             Supplied by client
Note: The core(s) is(are) originally attached to the cable(s).




3.1.1      Configuration of System Under Test



For Charging Mode:



                                                                   Load (A)


                                         1
              Adapter (EUT)                     USB                 EUT
                  120Vac




For Standby Mode:




                                         1
            Adapter (EUT)                       USB                 EUT
                  120Vac




Report No.: SA190107D06                                     Page No. 6 / 13                              Report Format Version: 6.1.1


3.2     Test Setup




                                                 15 cm / 20cm




                                                                              EUT

                      Field Probe




Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm or
     20 cm measured from the center of the probe(s) to the edge of the device.

3.3     Test Instruments

       Description         Brand     Model No.     Frequency Range Calibrated Date Calibrated Until
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018      Mar. 27, 2020
       Meter
   Magnetic Field
                          NARDA       ELT-400          1 – 400kHz       Apr. 12, 2018     Apr. 11, 2020
      Meter
  Magnetic Probe          NARDA       HF-3061       300kHz – 30MHz      Apr. 16, 2018     Apr. 15, 2020
  Magnetic Probe          NARDA       HF-0191        27 – 1000MHz       Apr. 17, 2018     Apr. 16, 2020
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018      Mar. 27, 2020
       Meter
Electric Field Meter COMBINOVA        EFM 200        5Hz – 400kHz       Dec. 6, 2017      Dec. 5, 2019
      E-Field Probe       NARDA       EF-0391       100kHz – 3GHz      Mar. 28, 2018      Mar. 27, 2020
      E-Field Probe       NARDA       EF-6091      100MHz – 60GHz        Mar. 29, 2018  Mar. 28, 2020
NOTE: 1. The calibration interval of the above test instruments is 12/24 months and the
          calibrations are traceable to NML/ROC and NIST/USA.
      2. The test was performed in Chia Pau RF Chamber




Report No.: SA190107D06                      Page No. 7 / 13                         Report Format Version: 6.1.1


3.4    Limits for Maximum Permissible Exposure (MPE)
§ 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of
  human exposure to radiofrequency(RF) radiation as specified in § 1.1307(b), except in the case of portable
  devices which shall be evaluated according to the provisions of § 2.1093 of this chapter.




680106 D01 RF Exposure Wireless Charging App v03
The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all
simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

3.5    Test Point Description



                          Z-axis (Above)
                                       Top




      Left                                       Right




                 Bottom




Report No.: SA190107D06                      Page No. 8 / 13                        Report Format Version: 6.1.1


4      Calculation Result of Maximum Conducted Power
Charging Mode with 10% Load
                                           E-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side             Left           Right                 Top          Bottom               Z-axis
    Max E-field (V/m)      1.0200         0.7600                1.2100        0.7700               0.8100
       Limit (V/m)          614             614                  614           614                   614
      Margin (V/m)        -612.9800     -613.2400              -612.7900    -613.2300            -613.1900
    50 % Limit (V/m)        307             307                  307           307                   307
50 % Margin (V/m)         -305.9800     -306.2400              -305.7900    -306.2300            -306.1900

                                           H-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side              Left           Right                Top          Bottom               Z-axis
    Max H-field (uT)        0.1780         0.1910               0.1240        0.1120               0.1700
    Max H-field (A/m)       0.1424         0.1528               0.0992        0.0896               0.1360
       Limit (A/m)           1.63           1.63                 1.63          1.63                 1.63
      Margin (A/m)         -1.4876         -1.4772              -1.5308      -1.5404              -1.4940
    50 % Limit (A/m)        0.815           0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6726            -0.6622           -0.7158          -0.7254           -0.6790
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.

Charging Mode with 50% Load
                                           E-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side              Left           Right                Top          Bottom               Z-axis
    Max E-field (V/m)       1.1200         0.8500               1.2800        0.8800               0.9200
       Limit (V/m)           614            614                  614           614                   614
      Margin (V/m)        -612.8800      -613.1500             -612.7200    -613.1200            -613.0800
    50 % Limit (V/m)         307            307                  307           307                   307
50 % Margin (V/m)         -305.8800      -306.1500             -305.7200    -306.1200            -306.0800

                                           H-Field Measurement
        Distance                                     15cm                                           20cm
       EUT Side              Left           Right                Top          Bottom               Z-axis
    Max H-field (uT)        0.1840         0.1960               0.1310        0.1160               0.1730
    Max H-field (A/m)       0.1472         0.1568               0.1048        0.0928               0.1384
       Limit (A/m)           1.63           1.63                 1.63          1.63                 1.63
      Margin (A/m)         -1.4828         -1.4732              -1.5252      -1.5372              -1.4916
    50 % Limit (A/m)        0.815           0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6678            -0.6582           -0.7102          -0.7222           -0.6766
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190107D06                      Page No. 9 / 13                          Report Format Version: 6.1.1


Charging Mode with Full Load
                                           E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         2.1200          1.8500                2.2900       1.8700               1.9200
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -611.8800      -612.1500              -611.7100   -612.1300            -612.0800
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -304.8800      -305.1500          -304.7100       -305.1300            -305.0800

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1860          0.1990                0.1330       0.1190               0.1760
 Max H-field (A/m)         0.1488          0.1592                0.1064       0.0952               0.1408
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4812         -1.4708               -1.5236     -1.5348              -1.4892
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6662            -0.6558           -0.7086          -0.7198           -0.6742
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.

Charging Mode with 10% Load (With 3mm airgap)
                                      E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.3200          1.2500                1.1900       1.6300               1.2600
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.6800      -612.7500          -612.8100       -612.3700            -612.7400
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.6800      -305.7500          -305.8100       -305.3700            -305.7400

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1780          0.1720                0.1590       0.1390               0.1460
 Max H-field (A/m)         0.1424          0.1376                0.1272       0.1112               0.1168
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4876         -1.4924               -1.5028     -1.5188              -1.5132
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6726            -0.6774           -0.6878          -0.7038           -0.6982
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.




Report No.: SA190107D06                      Page No. 10 / 13                         Report Format Version: 6.1.1


Charging Mode with 50% Load (With 3mm airgap)
                                      E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.3600          1.2900                1.2300       1.6700               1.3100
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.6400      -612.7100              -612.7700   -612.3300            -612.6900
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.6400      -305.7100              -305.7700   -305.3300            -305.6900

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1810          0.1750                0.1620       0.1620               0.1620
 Max H-field (A/m)         0.1448          0.1400                0.1296       0.1296               0.1296
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4852         -1.4900               -1.5004     -1.5004              -1.5004
  50 % Limit (A/m)         0.815            0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.6702            -0.6750           -0.6854          -0.6854           -0.6854
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with Full Load (With 3mm airgap)
                                        E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.7800          1.7100                1.6500       2.0900               1.7200
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.2200      -612.2900              -612.3500   -611.9100            -612.2800
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.2200      -305.2900              -305.3500   -304.9100            -305.2800

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.2050          0.1990                0.1860       0.1660               0.1730
 Max H-field (A/m)         0.1640          0.1592                0.1488       0.1328               0.1384
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4660         -1.4708               -1.4812     -1.4972              -1.4916
  50 % Limit (A/m)         0.815            0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.6510            -0.6558           -0.6662          -0.6822           -0.6766
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.



Report No.: SA190107D06                      Page No. 11 / 13                         Report Format Version: 6.1.1


Standby Mode
                                           E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         0.1700          0.1600               0.2300        0.2500               0.1800
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -613.8300      -613.8400          -613.7700       -613.7500            -613.8200
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -306.8300      -306.8400          -306.7700       -306.7500            -306.8200

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.1210          0.1140               0.1250        0.1360               0.1420
 Max H-field (A/m)         0.0968          0.0912               0.1000        0.1088               0.1136
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.5332         -1.5388              -1.5300      -1.5212              -1.5164
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.7182            -0.7238           -0.7150          -0.7062           -0.7014
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.




Report No.: SA190107D06                      Page No. 12 / 13                         Report Format Version: 6.1.1


5    Photographs of the Test Configuration

Please refer to the attached file (Test Setup Photo).



--- END ---




Report No.: SA190107D06                        Page No. 13 / 13   Report Format Version: 6.1.1



Document Created: 2019-02-25 16:56:38
Document Modified: 2019-02-25 16:56:38

© 2025 FCC.report