RF Exposure Info (MPE)

FCC ID: K7SF7U053

RF Exposure Info

Download: PDF
FCCID_4209271

                                                     RF Exposure Test Report

                       Report No.: SA190130D01

                             FCC ID: K7SF7U053

                       Test Model: F7U053

                 Received Date: Jan. 22, 2019

                         Test Date: Jan. 28 ~ Feb. 1, 2019

                     Issued Date: Feb. 21, 2019


                         Applicant: Belkin International., Inc

                          Address: 12045 East Waterfront Drive, Playa Vista, CA. 90094, USA


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
         FCC Registration /
       Designation Number: 198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by any government agencies.

Report No.: SA190130D01                                              Page No. 1 / 22                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Report Issue History Record .......................................................................................................................... 3
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         General Information .............................................................................................................................. 5
    2.1      General Description of EUT ................................................................................................................ 5
3         RF Exposure .......................................................................................................................................... 6
    3.1      Description of Support Units ............................................................................................................... 6
    3.1.1    Configuration of System Under Test.................................................................................................... 6
    3.2      Test Setup ........................................................................................................................................... 7
    3.3      Test Instruments .................................................................................................................................. 7
    3.4      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 8
    3.5      Test Point Description ......................................................................................................................... 8
4         Calculation Result of Maximum Conducted Power........................................................................... 9
5         Photographs of the Test Configuration ............................................................................................ 22




Report No.: SA190130D01                                              Page No. 2 / 22                                             Report Format Version: 6.1.1


                                          Report Issue History Record

Issue No.             Description                                              Date Issued
SA190130D01           Original release.                                        Feb. 21, 2019




                                            Release Control Record


Issue No.             Description                                              Date Issued
SA190130D01           Original release                                         Feb. 21, 2019




Report No.: SA190130D01                         Page No. 3 / 22         Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: BOOST↑UP™ Wireless Charging Vent Mount 10W

              Brand: belkin

        Test Model: F7U053

    Sample Status: Engineering sample

          Applicant: Belkin International., Inc

          Test Date: Jan. 28 ~ Feb. 1, 2019

         Standards: FCC Part 1 (Section 1.1307(b), 1.1310)



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                      , Date:          Feb. 21, 2019
                               Annie Chang / Senior Specialist




     Approved by :                                                      , Date:          Feb. 21, 2019
                           Rex Lai / Associate Technical Manager




Report No.: SA190130D01                       Page No. 4 / 22                         Report Format Version: 6.1.1


2     General Information
2.1    General Description of EUT

 Product                          BOOST↑UP™ Wireless Charging Vent Mount 10W
 Brand                            belkin
 Test Model                       F7U053
 Sample Status                    Engineering sample
                                  Input: 12Vdc, 2A,
 Rating
                                  Output: 10W
 Modulation Type                  FSK
 Operating Frequency              111-148kHz
 Antenna Type                     Coil antenna
 Field Strength                   85.64dBuV/m
 Dimensions                       14.52cm2 (diameter = 43mm)
 Accessory Device                 N/A
 Data Cable Supplied              1.2m Non-shielded DC cable attached on EUT
 Maximum Power Output from
                                  10W
 the Charging Coil
Note:
1. The EUT is a BOOST↑UP™ Wireless Charging Vent Mount 10W with Qi charging function.
2. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: SA190130D01                      Page No. 5 / 22                       Report Format Version: 6.1.1


3        RF Exposure
3.1       Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
    ID       Product                 Brand                Model No.           Serial No.         FCC ID               Remarks
                                                                                                                  Supplied by client
    A.         Load                   N/A                    N/A                 N/A              N/A
                                                                                                                  (10W max load)
    B.       iPhone X                Apple                  A1901                NA            BCG-E3175A         Supplied by client
    C.        Battery               RKSING             SMF NX120-7L              NA               N/A             Provided by Lab
Note: All power cords of the above support units are non-shielded (1.8m).


    ID     Descriptions               Qty.               Length (m)       Shielding (Yes/No)    Cores (Qty.)          Remarks
    1.       DC cable                   1                    1.2                   N                 0            Supplied by client
Note: The core(s) is(are) originally attached to the cable(s).


3.1.1      Configuration of System Under Test

Charging Mode with Load:

                                                                   Load (A)


                                         1
                Battery (C)                     DC                  EUT
                   12Vdc




Charging Mode with iPhone:



                                                                 iPhone X (B)


                                         1
               Battery (C)                      DC                  EUT
                  12Vdc




Standby Mode:




                                         1
               Battery (C)                      DC                  EUT
                  12Vdc




Report No.: SA190130D01                                     Page No. 6 / 22                               Report Format Version: 6.1.1


3.2     Test Setup




                                                 15 cm / 20cm




                                                                              EUT

                      Field Probe




Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm or
     20 cm measured from the center of the probe(s) to the edge of the device.

3.3     Test Instruments

       Description         Brand     Model No.     Frequency Range Calibrated Date Calibrated Until
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018      Mar. 27, 2020
       Meter
   Magnetic Field
                          NARDA       ELT-400          1 – 400kHz       Apr. 12, 2018     Apr. 11, 2020
      Meter
  Magnetic Probe          NARDA       HF-3061       300kHz – 30MHz      Apr. 16, 2018     Apr. 15, 2020
  Magnetic Probe          NARDA       HF-0191        27 – 1000MHz       Apr. 17, 2018     Apr. 16, 2020
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018      Mar. 27, 2020
       Meter
Electric Field Meter COMBINOVA        EFM 200        5Hz – 400kHz       Dec. 6, 2017      Dec. 5, 2019
      E-Field Probe       NARDA       EF-0391       100kHz – 3GHz      Mar. 28, 2018      Mar. 27, 2020
      E-Field Probe       NARDA       EF-6091      100MHz – 60GHz        Mar. 29, 2018  Mar. 28, 2020
NOTE: 1. The calibration interval of the above test instruments is 12/24 months and the
          calibrations are traceable to NML/ROC and NIST/USA.
      2. The test was performed in Chia Pau RF Chamber




Report No.: SA190130D01                      Page No. 7 / 22                         Report Format Version: 6.1.1


3.4    Limits for Maximum Permissible Exposure (MPE)
§ 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of
  human exposure to radiofrequency(RF) radiation as specified in § 1.1307(b), except in the case of portable
  devices which shall be evaluated according to the provisions of § 2.1093 of this chapter.




680106 D01 RF Exposure Wireless Charging App v03
The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all
simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

3.5    Test Point Description



                          Z-axis (Above)
                                       Top




      Left                                       Right




                 Bottom




Report No.: SA190130D01                      Page No. 8 / 22                        Report Format Version: 6.1.1


4      Calculation Result of Maximum Conducted Power
Charging Mode with max Load (at center)
                                           E-Field Measurement
        Distance                                      15cm                                          20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max E-field (V/m)      0.6100          0.6300               0.7400        0.5500               0.4800
       Limit (V/m)          614             614                  614           614                   614
      Margin (V/m)        -613.3900       -613.3700            -613.2600    -613.4500            -613.5200
    50 % Limit (V/m)        307             307                  307           307                   307
50 % Margin (V/m)         -306.3900       -306.3700            -306.2600    -306.4500            -306.5200

                                           H-Field Measurement
        Distance                                      15cm                                          20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max H-field (uT)       0.1960          0.1620               0.1640        0.1780               0.1660
    Max H-field (A/m)      0.1568          0.1296               0.1312        0.1424               0.1328
       Limit (A/m)          1.63            1.63                 1.63          1.63                 1.63
      Margin (A/m)         -1.4732         -1.5004              -1.4988      -1.4876              -1.4972
    50 % Limit (A/m)       0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6582            -0.6854           -0.6838          -0.6726           -0.6822
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.

Charging Mode with max Load (shift 5mm to top)
                                        E-Field Measurement
        Distance                                      15cm                                          20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max E-field (V/m)      0.9100          0.6900               0.9400        0.7600               0.7500
       Limit (V/m)          614             614                  614           614                   614
      Margin (V/m)        -613.0900       -613.3100            -613.0600    -613.2400            -613.2500
    50 % Limit (V/m)        307             307                  307           307                   307
50 % Margin (V/m)         -306.0900       -306.3100            -306.0600    -306.2400            -306.2500

                                           H-Field Measurement
        Distance                                      15cm                                          20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max H-field (uT)       0.2190          0.2430               0.2170        0.2810               0.2720
    Max H-field (A/m)      0.1752          0.1944               0.1736        0.2248               0.2176
       Limit (A/m)          1.63            1.63                 1.63          1.63                 1.63
      Margin (A/m)         -1.4548         -1.4356              -1.4564      -1.4052              -1.4124
    50 % Limit (A/m)       0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6398            -0.6206           -0.6414          -0.5902           -0.5974
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 9 / 22                          Report Format Version: 6.1.1


Charging Mode with max Load (shift 5mm to bottom)
                                        E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         0.8800          0.7100               0.7300        0.9500               0.8000
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -613.1200      -613.2900          -613.2700       -613.0500            -613.2000
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -306.1200      -306.2900          -306.2700       -306.0500            -306.2000

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.2210          0.2400               0.1820        0.3100               0.2690
 Max H-field (A/m)         0.1768          0.1920               0.1456        0.2480               0.2152
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.4532         -1.4380              -1.4844      -1.3820              -1.4148
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.6382            -0.6230           -0.6694          -0.5670           -0.5998
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.

Charging Mode with max Load with 3mm airgap (at center)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         0.7200          0.6500               0.8100        0.8200               1.2600
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -613.2800      -613.3500          -613.1900       -613.1800            -612.7400
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -306.2800      -306.3500          -306.1900       -306.1800            -305.7400

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.3270          0.2950               0.3940        0.3130               0.6510
 Max H-field (A/m)         0.2616          0.2360               0.3152        0.2504               0.5208
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.3684         -1.3940              -1.3148      -1.3796              -1.1092
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.5534            -0.5790           -0.4998          -0.5646           -0.2942
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.



Report No.: SA190130D01                      Page No. 10 / 22                         Report Format Version: 6.1.1


Charging Mode with max Load with 3mm airgap (shift 5mm to top)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         0.7500          0.6900                0.9400       0.7300               1.2800
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -613.2500      -613.3100              -613.0600   -613.2700            -612.7200
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -306.2500      -306.3100              -306.0600   -306.2700            -305.7200

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.3290          0.2930                0.4110       0.3020               0.6560
 Max H-field (A/m)         0.2632          0.2344                0.3288       0.2416               0.5248
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.3668         -1.3956               -1.3012     -1.3884              -1.1052
  50 % Limit (A/m)         0.815            0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.5518            -0.5806           -0.4862          -0.5734           -0.2902
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with max Load with 3mm airgap (shift 5mm to bottom)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         0.7400          0.6200                0.7000       0.9600               1.2800
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -613.2600      -613.3800              -613.3000   -613.0400            -612.7200
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -306.2600      -306.3800              -306.3000   -306.0400            -305.7200

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.3220          0.2990                0.3770       0.3350               0.6600
 Max H-field (A/m)         0.2576          0.2392                0.3016       0.2680               0.5280
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.3724         -1.3908               -1.3284     -1.3620              -1.1020
  50 % Limit (A/m)         0.815            0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.5574            -0.5758           -0.5134          -0.5470           -0.2870
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 11 / 22                         Report Format Version: 6.1.1


Charging Mode with iPhone 10% Charge (at center)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.4600          1.5600                2.2800       1.7100               1.6800
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.5400      -612.4400              -611.7200   -612.2900            -612.3200
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.5400      -305.4400          -304.7200       -305.2900            -305.3200

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1130          0.0950                0.1010       0.1320               0.1120
 Max H-field (A/m)         0.0904          0.0760                0.0808       0.1056               0.0896
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.5396         -1.5540               -1.5492     -1.5244              -1.5404
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.7246            -0.7390           -0.7342          -0.7094           -0.7254
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with iPhone 50% Charge (at center)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.8600          1.9300                2.5000       2.0200               1.9800
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.1400      -612.0700              -611.5000   -611.9800            -612.0200
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.1400      -305.0700          -304.5000       -304.9800            -305.0200

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1510          0.1230                0.1070       0.1350               0.1320
 Max H-field (A/m)         0.1208          0.0984                0.0856       0.1080               0.1056
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.5092         -1.5316               -1.5444     -1.5220              -1.5244
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6942            -0.7166           -0.7294          -0.7070           -0.7094
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 12 / 22                         Report Format Version: 6.1.1


Charging Mode with iPhone 90% Charge (at center)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.9900          2.3100                2.6800       2.0800               2.0100
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.0100      -611.6900              -611.3200   -611.9200            -611.9900
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.0100      -304.6900          -304.3200       -304.9200            -304.9900

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1580          0.1320                0.1120       0.1460               0.1440
 Max H-field (A/m)         0.1264          0.1056                0.0896       0.1168               0.1152
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.5036         -1.5244               -1.5404     -1.5132              -1.5148
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6886            -0.7094           -0.7254          -0.6982           -0.6998
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with iPhone 10% Charge (shift 5mm to top)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.3700          1.4900                2.5800       1.6600               1.7100
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.6300      -612.5100              -611.4200   -612.3400            -612.2900
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.6300      -305.5100          -304.4200       -305.3400            -305.2900

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1280          0.1040                0.1070       0.1220               0.1130
 Max H-field (A/m)         0.1024          0.0832                0.0856       0.0976               0.0904
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.5276         -1.5468               -1.5444     -1.5324              -1.5396
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.7126            -0.7318           -0.7294          -0.7174           -0.7246
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 13 / 22                         Report Format Version: 6.1.1


Charging Mode with iPhone 50% Charge (shift 5mm to top)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.5500          1.7400                2.8100       1.8300               1.9000
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.4500      -612.2600              -611.1900   -612.1700            -612.1000
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.4500      -305.2600          -304.1900       -305.1700            -305.1000

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1510          0.1290                0.1180       0.1360               0.1280
 Max H-field (A/m)         0.1208          0.1032                0.0944       0.1088               0.1024
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.5092         -1.5268               -1.5356     -1.5212              -1.5276
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6942            -0.7118           -0.7206          -0.7062           -0.7126
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with iPhone 90% Charge (shift 5mm to top)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.6200          1.9300                3.0300       2.0800               2.1500
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.3800      -612.0700          -610.9700       -611.9200            -611.8500
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.3800      -305.0700          -303.9700       -304.9200            -304.8500

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1770          0.1480                0.1360       0.1590               0.1500
 Max H-field (A/m)         0.1416          0.1184                0.1088       0.1272               0.1200
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4884         -1.5116               -1.5212     -1.5028              -1.5100
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6734            -0.6966           -0.7062          -0.6878           -0.6950
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 14 / 22                         Report Format Version: 6.1.1


Charging Mode with iPhone 10% Charge (shift 5mm to bottom)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         1.9600          1.7000               3.3800        2.1700               1.7200
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -612.0400      -612.3000          -610.6200       -611.8300            -612.2800
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -305.0400      -305.3000          -303.6200       -304.8300            -305.2800

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.1240          0.1260               0.1670        0.2080               0.1970
 Max H-field (A/m)         0.0992          0.1008               0.1336        0.1664               0.1576
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.5308         -1.5292              -1.4964      -1.4636              -1.4724
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.7158            -0.7142           -0.6814          -0.6486           -0.6574
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with iPhone 50% Charge (shift 5mm to bottom)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         2.3600          1.4200               3.5800        2.4800               1.8300
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -611.6400      -612.5800          -610.4200       -611.5200            -612.1700
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -304.6400      -305.5800          -303.4200       -304.5200            -305.1700

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.1620          0.1540               0.1730        0.2110               0.2170
 Max H-field (A/m)         0.1296          0.1232               0.1384        0.1688               0.1736
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.5004         -1.5068              -1.4916      -1.4612              -1.4564
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.6854            -0.6918           -0.6766          -0.6462           -0.6414
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 15 / 22                         Report Format Version: 6.1.1


Charging Mode with iPhone 90% Charge (shift 5mm to bottom)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         2.4900          2.4500               3.6400        2.5400               2.0500
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -611.5100      -611.5500          -610.3600       -611.4600            -611.9500
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -304.5100      -304.5500          -303.3600       -304.4600            -304.9500

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.1690          0.1630               0.1780        0.2220               0.2290
 Max H-field (A/m)         0.1352          0.1304               0.1424        0.1776               0.1832
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.4948         -1.4996              -1.4876      -1.4524              -1.4468
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.6798            -0.6846           -0.6726          -0.6374           -0.6318
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with iPhone 10% Charge with 3mm airgap (at center)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         1.1500          1.4300               1.9800        1.3400               1.5100
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -612.8500      -612.5700          -612.0200       -612.6600            -612.4900
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -305.8500      -305.5700          -305.0200       -305.6600            -305.4900

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.1130          0.0950               0.1010        0.1320               0.1120
 Max H-field (A/m)         0.0904          0.0760               0.0808        0.1056               0.0896
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.5396         -1.5540              -1.5492      -1.5244              -1.5404
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.7246            -0.7390           -0.7342          -0.7094           -0.7254
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 16 / 22                         Report Format Version: 6.1.1


Charging Mode with iPhone 50% Charge with 3mm airgap (at center)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.1690          1.7300                2.3500       1.8900               1.7400
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.8310      -612.2700              -611.6500   -612.1100            -612.2600
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.8310      -305.2700          -304.6500       -305.1100            -305.2600

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1660          0.1370                0.1250       0.1470               0.1550
 Max H-field (A/m)         0.1328          0.1096                0.1000       0.1176               0.1240
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4972         -1.5204               -1.5300     -1.5124              -1.5060
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6822            -0.7054           -0.7150          -0.6974           -0.6910
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with iPhone 90% Charge with 3mm airgap (at center)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.8200          2.1300                2.4600       1.9400               1.9700
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.1800      -611.8700              -611.5400   -612.0600            -612.0300
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.1800      -304.8700          -304.5400       -305.0600            -305.0300

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1690          0.1450                0.1330       0.1690               0.1580
 Max H-field (A/m)         0.1352          0.1160                0.1064       0.1352               0.1264
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4948         -1.5140               -1.5236     -1.4948              -1.5036
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6798            -0.6990           -0.7086          -0.6798           -0.6886
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 17 / 22                         Report Format Version: 6.1.1


Charging Mode with iPhone 10% Charge with 3mm airgap (shift 5mm to top)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.1300          1.2200                2.2500       1.4300               1.5800
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.8700      -612.7800              -611.7500   -612.5700            -612.4200
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.8700      -305.7800          -304.7500       -305.5700            -305.4200

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1390          0.1250                0.1540       0.1460               0.1390
 Max H-field (A/m)         0.1112          0.1000                0.1232       0.1168               0.1112
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.5188         -1.5300               -1.5068     -1.5132              -1.5188
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.7038            -0.7150           -0.6918          -0.6982           -0.7038
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with iPhone 50% Charge with 3mm airgap (shift 5mm to top)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.4200          1.5800                2.6100       1.5900               1.7200
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.5800      -612.4200              -611.3900   -612.4100            -612.2800
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.5800      -305.4200          -304.3900       -305.4100            -305.2800

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1680          0.1350                0.1350       0.1480               0.1630
 Max H-field (A/m)         0.1344          0.1080                0.1080       0.1184               0.1304
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4956         -1.5220               -1.5220      -1.5116             -1.4996
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6806            -0.7070           -0.7070          -0.6966           -0.6846
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 18 / 22                         Report Format Version: 6.1.1


Charging Mode with iPhone 90% Charge with 3mm airgap (shift 5mm to top)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.4100          1.6200                2.7800       1.9500               2.0200
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.5900      -612.3800              -611.2200   -612.0500            -611.9800
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.5900      -305.3800          -304.2200       -305.0500            -304.9800

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1920          0.1680                0.1450       0.1770               0.1820
 Max H-field (A/m)         0.1536          0.1344                0.1160       0.1416               0.1456
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.4764         -1.4956               -1.5140     -1.4884              -1.4844
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.6614            -0.6806           -0.6990          -0.6734           -0.6694
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with iPhone 10% Charge with 3mm airgap (shift 5mm to bottom)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
 Max E-field (V/m)         1.8200          1.5600                3.1000       2.0300               1.6100
     Limit (V/m)            614             614                   614          614                   614
   Margin (V/m)           -612.1800      -612.4400          -610.9000       -611.9700            -612.3900
  50 % Limit (V/m)          307             307                   307          307                   307
50 % Margin (V/m)         -305.1800      -305.4400          -303.9000       -304.9700            -305.3900

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                 Top         Bottom               Z-axis
  Max H-field (uT)         0.1420          0.1390                0.1790       0.2210               0.2060
 Max H-field (A/m)         0.1136          0.1112                0.1432       0.1768               0.1648
     Limit (A/m)            1.63            1.63                  1.63         1.63                 1.63
   Margin (A/m)            -1.5164         -1.5188               -1.4868     -1.4532              -1.4652
  50 % Limit (A/m)         0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.7014            -0.7038           -0.6718          -0.6382           -0.6502
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 19 / 22                         Report Format Version: 6.1.1


Charging Mode with iPhone 50% Charge with 3mm airgap (shift 5mm to bottom)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         2.1800          1.2200               3.3200        2.1800               1.6900
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -611.8200      -612.7800          -610.6800       -611.8200            -612.3100
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -304.8200      -305.7800          -303.6800       -304.8200            -305.3100

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.1820          0.1770               0.1920        0.2230               0.2310
 Max H-field (A/m)         0.1456          0.1416               0.1536        0.1784               0.1848
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.4844         -1.4884              -1.4764      -1.4516              -1.4452
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.6694            -0.6734           -0.6614          -0.6366           -0.6302
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Charging Mode with iPhone 90% Charge with 3mm airgap (shift 5mm to bottom)
                                       E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         2.2600          2.3100               3.4800        2.4200               1.9600
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -611.7400      -611.6900          -610.5200       -611.5800            -612.0400
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -304.7400      -304.6900          -303.5200       -304.5800            -305.0400

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.1790          0.1820               0.1880        0.2350               0.2410
 Max H-field (A/m)         0.1432          0.1456               0.1504        0.1880               0.1928
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.4868         -1.4844              -1.4796      -1.4420              -1.4372
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.6718            -0.6694           -0.6646          -0.6270           -0.6222
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190130D01                      Page No. 20 / 22                         Report Format Version: 6.1.1


Standby Mode
                                           E-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
 Max E-field (V/m)         0.2100          0.1900               0.2100        0.2200               0.2200
     Limit (V/m)            614             614                  614           614                   614
   Margin (V/m)           -613.7900      -613.8100          -613.7900       -613.7800            -613.7800
  50 % Limit (V/m)          307             307                  307           307                   307
50 % Margin (V/m)         -306.7900      -306.8100          -306.7900       -306.7800            -306.7800

                                           H-Field Measurement
      Distance                                       15cm                                           20cm
     EUT Side               Left            Right                Top          Bottom               Z-axis
  Max H-field (uT)         0.0880          0.0860               0.0780        0.0850               0.1060
 Max H-field (A/m)         0.0704          0.0688               0.0624        0.0680               0.0848
     Limit (A/m)            1.63            1.63                 1.63          1.63                 1.63
   Margin (A/m)            -1.5596         -1.5612              -1.5676      -1.5620              -1.5452
  50 % Limit (A/m)         0.815            0.815               0.815         0.815                0.815
50 % Margin (A/m)       -0.7446            -0.7462           -0.7526          -0.7470           -0.7302
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.




Report No.: SA190130D01                      Page No. 21 / 22                         Report Format Version: 6.1.1


5    Photographs of the Test Configuration

Please refer to the attached file (Test Setup Photo).



--- END ---




Report No.: SA190130D01                        Page No. 22 / 22   Report Format Version: 6.1.1



Document Created: 2019-03-25 09:41:45
Document Modified: 2019-03-25 09:41:45

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC