mpe

FCC ID: K7SF7D5301V3

RF Exposure Info

Download: PDF
FCCID_1348720

             Compliance Certification Services Inc.
             Report No.: KS100824A01-RC   FCC ID: K7SF7D5301V3   Date of Issue: August 12, 2010


ELECTROMAGNETIC COMPATIBILITY CRITERIA FOR
INTENTIONAL RADIATORS

§ 15.247(b), A8.5    Peak Power Output and RF Exposure

RF Exposure Requirements:     §1.1307(b)(1) and §1.1307(b)(2): Systems operating
                           under the provisions of this section shall be operated in a
                           manner that ensures that the public is not exposed to
                           radio frequency energy levels in excess of the
                           Commission’s guidelines.
RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum
                           Permissible Exposure (MPE) Limit shall be used to
                           evaluate the environmental impact of human exposure to
                           radiofrequency (RF) radiation as specified in Sec.
                           1.1307(b), except in the case of portable devices which
                           shall be evaluated according to the provisions of Sec.
                           2.1093 of this chapter.


               MPE Limit Calculation: EUT’s operating frequencies @2.412GHz ~
               2.462GHz;2.422GHz ~ 2.452GHz; highest conducted power =
               19.12dBm (peak) therefore,
                                                           2          2
               Limit for Uncontrolled exposure: 1 mW/cm or 10 W/m



               EUT maximum antenna gain =0.13dBi.

               Equation from page 18 of OET 65, Edition 97-01
                             S = PG / 4πR2     or   R = √PG / 4πS
                    where,   S = Power Density (1 mW/cm2)
                             P = Power Input to antenna (78.34mW)
                             G = Antenna Gain (4.10 numeric)
                    R = (81.66*1.03/ 4*3.14*1.0)1/2= (321.20 / 12.56) 1/2 = 2.59cm
                    separation required in order to comply with the limit of 1 mW/cm2 for
                    Uncontrolled Exposure.



Document Created: 2010-09-23 15:02:34
Document Modified: 2010-09-23 15:02:34

© 2025 FCC.report