RF Exposure Info

FCC ID: K7SF5L146

RF Exposure Info

Download: PDF
FCCID_1878391

                                     RF EXPOSURE REPORT


                                         REPORT NO.: SA120406C03D
                                          MODEL NO.: F5L146
                                                FCC ID: K7SF5L146
                                             RECEIVED: Apr. 06, 2012
                                                  TESTED: Apr. 24, 2012
                                                  ISSUED: Jan. 10, 2013



                                           APPLICANT: Belkin International, Inc.

                                              ADDRESS: 12045 East Waterfront Dr. Playa Vista
                                                       California United States 90094



                                             ISSUED BY: Bureau Veritas Consumer Products Services
                                                        (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory

                                     LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen,
                                                  Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan,
                                                  R.O.C.




  This report should not be used by the client to claim
  product certification, approval, or endorsement by any
  government agencies.




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set
forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or
identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the
information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our
negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue
within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or
non-compliance to the specification

 Report No.: SA120406C03D                                                         1 of 6                                  Report Format Version 4.0.0
 Reference No.: 121023C16, 121220C12


                                 TABLE OF CONTENTS
RELEASE CONTROL RECORD .................................................................................... 3
1.        CERTIFICATION....................................................................................... 4
2.        EVALUATION RESULT ............................................................................ 5
3.        SAR TEST EXCLUSION THRESHOLDS.................................................. 6
4.        CONCLUSION .......................................................................................... 6




Report No.: SA120406C03D                                  2 of 6                       Report Format Version 4.0.0
Reference No.: 121023C16, 121220C12


                            RELEASE CONTROL RECORD

  ISSUE NO.                   REASON FOR CHANGE             DATE ISSUED
  SA120406C03D                Original release             Jan. 10, 2013




Report No.: SA120406C03D                          3 of 6   Report Format Version 4.0.0
Reference No.: 121023C16, 121220C12


 1.     CERTIFICATION


               PRODUCT:           Portable Keyboard Case

         BRAND NAME:              Belkin

            MODEL NO.:            F5L146

        TEST SAMPLE:              ENGINEERING SAMPLE

            APPLICANT:            Belkin International, Inc.

        TESTED DATE:              Apr. 24, 2012

           STANDARDS:             FCC Part 2 (Section 2.1091)

                                  FCC OET Bulletin 65, Supplement C (01-01)

                                  IEEE C95.1


The above equipment (Model: F5L146) has been tested by Bureau Veritas Consumer
Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the
requirement of the above standards. The test record, data evaluation & Equipment
Under Test (EUT) configurations represented herein are true and accurate accounts of
the measurements of the sample’s EMC characteristics under the conditions specified
in this report.




 PREPARED BY               :                                   ,   DATE:   Dec. 06, 2012
                               ( Phoenix Huang, Specialist )


 APPROVED BY               :                                   ,   DATE:   Dec. 06, 2012
                               ( May Chen, Deputy Manager )




Report No.: SA120406C03D                              4 of 6                Report Format Version 4.0.0
Reference No.: 121023C16, 121220C12


 2.     EVALUATION RESULT


Following FCC KDB 447498 D01 “General SAR test exclusion guidance”

The corresponding SAR Exclusion Threshold condition, listed below:

1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test
  separation distances ≤ 50 mm are determined by:
  [(max. power of channel, including tune-up tolerance, mW)/(min. test separation
  distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16
  where
  Ø     f(GHz) is the RF channel transmit frequency in GHz
  Ø     Power and distance are rounded to the nearest mW and mm before calculation
  Ø     The result is rounded to one decimal place for comparison
  The test exclusions are applicable only when the minimum test separation distance is
  ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the
  minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
  determine SAR test exclusion.

2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test
  exclusion threshold is determined according to the following:
  a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)]
    mW, at 100MHz to 1500 MHz
  b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at >
    1500 MHz and ≤ 6 GHz

3) At frequencies below 100 MHz, the following may be considered for SAR test
  exclusion.
  a) The threshold at the corresponding test separation distance at 100 MHz in step 2)
    is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and <
    200 mm.
  b) The threshold determined by the equation in a) for 50 mm and 100 MHz is
    multiplied by ½ for test separation distances ≤ 50 mm.
  c) SAR measurement procedures are not established below 100 MHz. When SAR test
    exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation
    requirements for any test results to be acceptable.




Report No.: SA120406C03D                     5 of 6                 Report Format Version 4.0.0
Reference No.: 121023C16, 121220C12


 3.     SAR TEST EXCLUSION THRESHOLDS

Maximum measured transmitter power:
                                        Min. test         SAR test       10-g extremity
    Frequency           Max. Power     separation         exclusion         SAR test
                                                                                                 Result
      (GHz)               (mW)          distance         calculation        exclusion
                                          (mm)           value(NOTE 2)     thresholds
  2.402 ~ 2.480            0.358            5                 0.111              3                 Pass
NOTE: 1. The antenna type is PIFA antenna with 1.56dBi gain.
      2. Calculate SAR test exclusion thresholds from condition “1” formulas.



 4.     CONCLUSION

Since Source-base time average power is below SAR test exclusion power thresholds,
the SAR evaluation is not required.



--- END ---




Report No.: SA120406C03D                             6 of 6                     Report Format Version 4.0.0
Reference No.: 121023C16, 121220C12