Test Report

FCC ID: K66VX-150

Test Report

Download: PDF
FCCID_1109883

                                           849 NW State Road 45
                                           Newberry, Fl 32669 USA
                                           Phone: 888.472.2424 or 352.472.5500
                                           Fax: 352.472.2030
                                           Email: info@timcoengr.com
                                           Website: www.timcoengr.com




                        FCC PART 15
                    SCANNING RECEIVER
           Applicant            VERTEX STANDARD CO., LTD.
             Address      4-8-8 NAKAMEGURO, MEGURO-KU
                                        TOKYO 153-8644
                                            JAPAN
             FCC ID:                            K66VX-150
       Model Number                              FT-250R
  Product Description                  SCANNING RECEIVER
Date Sample Received                            4/23/2009
         Date Tested                            4/30/2009
           Tested By                            Joe Scoglio
        Approved By                       Mario de Aranzeta
      Report Number                  855AUT9TestReport.doc
         Test Results                  PASS                   FAIL


THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL
  WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC.




                        Certificate # 0955-01


                                          TABLE OF CONTENTS


GENERAL REMARKS ...................................................................................................3

GENERAL INFORMATION ............................................................................................4

TEST EQUIPMENT LIST ...............................................................................................5

TEST PROCEDURE......................................................................................................6

RADIATED SPURIOUS EMISSIONS .............................................................................7

POWER LINE CONDUCTED INTERFERENCE ..............................................................8




APPLICANT: VERTEX STANDARD CO., LTD.
   FCC ID: K66VX-150
REPORT #: V\VERTEX_STANDARD\855AUT9\855AUT9TestReport.doc

                                                                                             Page 2 of 8


GENERAL REMARKS

The attached report shall not be reproduced except in full without the written
permission of Timco Engineering Inc.

Summary

The device under test does:
      fulfill the general approval requirements as identified in this test report
      not fulfill the general approval requirements as identified in this test report

This is a request for a Class II Permissive change. With the change, this device
becomes model number FT-250R. Radiated emissions testing was completed and
there is no degradation from previously reported data.

Attestations

This equipment has been tested in accordance with the standards identified in this
test report. To the best of my knowledge and belief, these tests were performed using
the measurement procedures described in this report.

All instrumentation and accessories used to test products for compliance to the
indicated standards are calibrated regularly in accordance with ISO 17025
requirements.



                                                            Testing Certificate # 0955-01

I attest that the necessary measurements were made, under my supervision, at:

Timco Engineering Inc.
849 NW State Road 45
Newberry, Fl 32669




Authorized Signatory Name:

Mario de Aranzeta C.E.T.
Compliance Engineer/ Lab. Supervisor

Date: 4/30/2009




APPLICANT: VERTEX STANDARD CO., LTD.
   FCC ID: K66VX-150
REPORT #: V\VERTEX_STANDARD\855AUT9\855AUT9TestReport.doc

                                                                        Page 3 of 8


GENERAL INFORMATION

                  The test results relate only to the items tested.
        DUT Description    SCANNING RECEIVER
                 FCC ID    K66VX-150
          Model Number     FT-250R
      DUT Power Source        110–120Vac/50– 60Hz
                              DC Power
                              Battery Operated Exclusively
              Test Item       Prototype
                              Pre-Production
                              Production
    Modifications to DUT   None
         Test Standards    FCC Part 15, Subpart B, ANSI C63.4-2003




APPLICANT: VERTEX STANDARD CO., LTD.
   FCC ID: K66VX-150
REPORT #: V\VERTEX_STANDARD\855AUT9\855AUT9TestReport.doc

                                                                      Page 4 of 8


 TEST EQUIPMENT LIST

                                                     Serial      Cal/Char
     Device          Manufacturer      Model                                 Due Date
                                                    Number         Date
                                                                   Listed
3/10-Meter OATS           TEI             N/A         N/A                    3/19/10
                                                                 3/20/07
                                                                   Listed
  3-Meter OATS            TEI             N/A         N/A                     2/5/12
                                                                  2/5/09
  3-Meter Semi-
                                                                  Listed
    Anechoic           Panashield         N/A         N/A                    5/11/10
                                                                 5/11/07
    Chamber
  Analyzer Tan
                                                                  CAL
Tower Quasi-Peak           HP           85650A     3303A01690                11/30/09
                                                                11/30/07
     Adapter
  Analyzer Tan
                                                                  CAL
    Tower RF               HP           85685A     3221A01400                11/30/09
                                                                11/30/07
   Preselector
  Analyzer Tan
                                       8566B Opt   3138A07786     CAL
 Tower Spectrum            HP                                                11/30/09
                                          462      3144A20661   11/30/07
     Analyzer
  Analyzer Tan
                                                                  CAL
      Tower                HP          8449B-H02   3008A00372                11/30/09
                                                                11/30/07
   Preamplifier

  Frequency
                           HP            5385A     2730A03025   CAL 7/6/07    7/6/09
   Counter
    Hygro-                                                         CAL
                         Extech         445703        0602                   11/15/09
 Thermometer                                                    11/15/07
Measuring Tape-                           7.5M                    CHAR
                        Kraftixx                                             11/13/09
     7.5M                                PROFI                  11/13/07
  Modulation
                           HP            8901A     3435A06868   CAL 5/9/07    5/9/09
   Analyzer
                                       FLUKE-77-                   CAL
Digital Multimeter       Fluke                      79510405                 5/14/09
                                            3                    5/14/07
                                         System                   CHAR
   System One        Audio Precision               SYS1-45868                2/27/10
                                          One                    2/27/08
  Temperature           Tenney                                    CHAR
                                         TTRC       11717-7                  4/25/10
    Chamber           Engineering                                4/25/08




 APPLICANT: VERTEX STANDARD CO., LTD.
    FCC ID: K66VX-150
 REPORT #: V\VERTEX_STANDARD\855AUT9\855AUT9TestReport.doc

                                                                     Page 5 of 8


TEST PROCEDURE


General: This report shall NOT be reproduced except in full without the written approval of
TIMCO ENGINEERING, INC.

Radiation Interference: The test procedure used was ANSI Standard C63.4-2003 using a
spectrum analyzer with a pre-selector. The bandwidth of the spectrum analyzer was 100 kHz
with an appropriate sweep speed. The analyzer was calibrated in dB above a microvolt at the
output of the antenna. The video bandwidth was always greater than or equal to the RBW.

Formula Of Conversion Factors: The Field Strength at 3m was established by adding the
meter reading of the spectrum analyzer (which is set to read in units of dBuV) to the antenna
correction factor supplied by the antenna manufacturer. The antenna correction factors are
stated in terms of dB. The gain of the Preselector was accounted for in the Spectrum Analyzer
Meter Reading.

       Example:
       Freq (MHz)    Meter Reading      + ACF            +CL          = FS
       33            20 dBuV            + 10.36 dB/m     +0.40 dB     =30.36 dBuV/m @ 3m

ANSI C63.4-2003 Section 10.1.7 Measurement Procedures:              The unit under test
was placed on a table 80 cm high and with dimensions of 1mby 1.5m. The table used for
radiated measurements is capable of continuous rotation. When an emission was found, the
table was rotated to produce the maximum signal strength. At this point, the antenna was
raised and lowered from 1m to 4m. The antenna was placed in both the horizontal and
verticals planes.

If powerline conducted testing was required for this device, the situation was similar for the
conducted measurement except that the table did not rotate. The EUT was setup as described
in ANSI C63.4-2003 with the EUT 40 cm from the vertical ground wall.




APPLICANT: VERTEX STANDARD CO., LTD.
   FCC ID: K66VX-150
REPORT #: V\VERTEX_STANDARD\855AUT9\855AUT9TestReport.doc

                                                                          Page 6 of 8


RADIATED SPURIOUS EMISSIONS

Rules Part No.:        15.109

Requirements:

                  Frequency                           Limits
                   30 – 88                40.0 dBµV/m measured @ 3 meters
                   80 – 216               43.5 dBµV/m measured @ 3 meters
                  216 – 960               46.0 dBµV/m measured @ 3 meters
                  Above 960               54.0 dBµV/m measured @ 3 meters

Test Procedure:     The procedure used was ANSI C63.4-2003. The frequency was scanned
from 30 MHz to 1.0 GHz. When an emission was found, the table was rotated to produce the
maximum signal strength. The DUT was measured in three (3) orthogonal planes.




Test Data:

  Tuned      Emission          Meter    Ant.   Coax     Correction     Field     Margin
Frequency    Frequency        Reading   Pol    Loss       Factor     Strength     dB
   MHz          MHz            dBµV             dB        dB/m       dBµV/m
  140.5       118.80            1.9      H     0.67       13.54       16.11       27.39
  140.5       118.80            2.1      V     0.67       13.66       16.43       27.07
  155.0       133.30            1.8      H     0.68       12.90       15.38       28.12
  155.0       133.30            2.0      V     0.68       12.73       15.41       28.09
  173.5       151.80            1.7      H     0.71       13.79       16.20       27.30
  173.5       151.80            2.0      V     0.71       14.37       17.08       26.42




APPLICANT: VERTEX STANDARD CO., LTD.
   FCC ID: K66VX-150
REPORT #: V\VERTEX_STANDARD\855AUT9\855AUT9TestReport.doc

                                                                       Page 7 of 8


POWER LINE CONDUCTED INTERFERENCE

Rules Part No.:   Part 15.107

Requirements:
                  Frequency            Quasi Peak Limits            Average Limits
                    (MHz)                   (dBµV)                      (dBµV)
                  0.15 – 0.5                66 – 56                    56 – 46
                   0.5 – 5.0                  56                          46
                   5.0 – 30                   60                          50

Test Procedure:   ANSI Standard C63.4-2003. The spectrum was scanned from 0.15 to
                  30 MHz .

Test Data:        The attached graphs represent the emissions read for power line
                  conducted. Both lines were observed.




NOTE DUT BATTERY POWERED HANDHELD




APPLICANT: VERTEX STANDARD CO., LTD.
   FCC ID: K66VX-150
REPORT #: V\VERTEX_STANDARD\855AUT9\855AUT9TestReport.doc

                                                                       Page 8 of 8



Document Created: 2009-05-12 20:11:47