test report

FCC ID: K66FT-897

Test Report

Download: PDF
FCCID_242538

                                                                FCC ID: K66FT-897




                            C E R T I F I C A T I O N

                                        of

                              RECEIVER MODEL: FT-897

                                FCC ID: K66FT-897

                                        to


                         FEDERAL COMMUNICATIONS COMMISSION


                                    Part 15(B)
                                      (New)


                           DATE OF REPORT: May 1, 2002


ON THE BEHALF OF THE APPLICANT:

                            Vertex Standard Co., Ltd.


AT THE REQUEST OF:                                        P.O. UPS 4/24/2002

                            Vertex Standard USA Inc.
                            10900 Walker Street
                            Cypress, CA 90630

Attention of:               Mikio Maruya, Executive Vice President
                            (800) 255-9237; FAX: (800) 477-9237
                            (714) 827-7600; FAX: -8100
                            m.maruya@vxstdusa.com




SUPERVISED BY:                                   Morton Flom, P. Eng.




MFA p0240006, d0250001


                                                             FCC ID: K66FT-897


                              TABLE OF CONTENTS


RULE                DESCRIPTION                                         PAGE



2.948               Description of Measurement Facilities                   1

15.109              Receiver Spurious Emissions (Radiated)                  6

15.121(b)           Scanning Receiver                                      11

15.107              A/C Powerline Conducted Emissions                      13




MFA p0240006, d0250001


                                                              FCC ID: K66FT-897


PAGE NO.                 1 of 19.

Required information per ISO/IEC Guide 25-1990, paragraph 13.2:

a)                               TEST REPORT

b) Laboratory:           M. Flom Associates, Inc.
  (FCC: 31040/SIT)       3356 N. San Marcos Place, Suite 107
  (Canada: IC 2044)      Chandler, AZ 85225

c) Report Number:        d0250001

d) Client:               Vertex Standard USA Inc.
                         10900 Walker Street
                         Cypress, CA 90630

e) Identification:       FT-897
                         FCC ID: K66FT-897
     Description:        Scanning Receiver

f) EUT Condition:        Not required unless specified in individual
                         tests.

g) Report Date:          May 1, 2002
   EUT Received:         April 24, 2002

h, j, k):                As indicated in individual tests.

i) Sampling method:      No sampling procedure used.

l) Uncertainty:          In accordance with MFA internal quality manual.

m) Supervised by:


                                               Morton Flom, P. Eng.
n) Results:              The results presented in this report relate
                         only to the item tested.

o) Reproduction:         This report must not be reproduced, except in
                         full, without written permission from this
                         laboratory.




MFA p0240006, d0250001


                                                        FCC ID: K66FT-897


PAGE NO.                 2 of 19.

M. Flom Associates, Inc. is accredited by the American Association
   for Laboratory Association (A2LA) as shown in the scope below.




"This laboratory is accredited by the American Association for
Laboratory Accreditation (A2LA) and the results shown in this
report have been determined in accordance with the laboratory's
terms of accreditation unless stated otherwise in the report."

Should this report contain any data for tests for which we are not
accredited, or which have been undertaken by a subcontractor that
is not A2LA accredited, such data would not covered by this
laboratory's                  A2LA                  accreditation.




MFA p0240006, d0250001


                                                          FCC ID: K66FT-897


PAGE NO.                  3 of 19.
                              GENERAL INFORMATION


Part 2.948:


(a)(b)         DESCRIPTION OF MEASUREMENT FACILITIES:
               FILE:     31040/SIT

               A description of the measurement facilities was filed
               with the Commission and was found to be in compliance
               with the requirements of Section 2.948, by letter dated
               March 13, 2000. All pertinent changes will be reported
               to the Commission by up-date prior to March 2003.



(b)(4)         SUPPORTING STRUCTURES:


                     SKETCH - ATTACHED EXHIBITS



(b)(5)(6)      TEST INSTRUMENTATION:


                     LIST - SEE EXHIBITS



2.925:         IDENTIFICATION OF AN AUTHORIZED DEVICE:


                     DRAWING - SEE EXHIBITS


                     LOCATION OF LABEL - SEE PHOTOS


               NAME AND ADDRESS OF APPLICANT:
                     Vertex Standard Co., Ltd.
                     4-8-8 Nakameguro, Meguro-Ku
                     Tokyo 153-8644 Japan




MFA p0240006, d0250001


                                                            FCC ID: K66FT-897


PAGE NO.                   4 of 19.
2.911:
2.1033(b)(6)

                                 TECHNICAL REPORT


               MANUFACTURER:


                     Vertex Standard Co., Ltd.
                     4-8-8 Nakameguro, Meguro-Ku
                     Tokyo 153-8644 Japan


               FCC ID:


                     K66FT-897


               MODEL NO:


                     FT-897


               PHOTOGRAPHS:


                     SEE LIST OF EXHIBITS


               DUT DESCRIPTION:


                     This unit Passes


15.31:         MEASUREMENT STANDARD & PROCEDURE:

                   IEEE STANDARD 187 WAS USED AS A GUIDE.
                   FCC MEASUREMENT PROCEDURE MP-1
               x   ANSI 63.4 (1992/2000) “Methods of measurement of
                   radio-noise emissions from low-voltage electrical and
                   electronic equipment in the range of 9 kHz to 40 GHz.”




MFA p0240006, d0250001


                                                               FCC ID: K66FT-897


PAGE NO.                   5 of 19.

                               EXPOSITORY STATEMENT


     1.      NUMBER OF BANDS                 = 4


     2.      NUMBER OF CHANNELS              = per manual


     3.      TUNING RANGE, MHz               = 0.1 to 56.0
                                               76 to 108
                                               118 to 164
                                               420 to 470


     4.      OSCILLATOR RANGE, MHz            = 68.4 to 124.32
                                                65.3 to 118.7
                                                186.33 to 232.33
                                                488.33 to 513.33


     5.      I.F., MHz                       = 68.33


     6.      BLOCK DIAGRAM                   = ATTACHED


     7.       For cellular receiver only, the radio transceiver meets
              the requirements of FCC Bulletin OET 53 ("Cellular System
              Mobile Stations-Land-System Compatibility
              Specification."). See attached affidavit.


15.203:        ANTENNA REQUIREMENT:

                   The   antenna is permanently attached to the EUT
                   The   antenna uses a unique coupling
                   The   EUT must be professionally installed
               x   The   antenna requirement does not apply




SUPERVISED BY:                                 Morton Flom, P. Eng.


MFA p0240006, d0250001


                                                                FCC ID: K66FT-897


PAGE NO.                    6 of 19.

NAME OF TEST:               Receiver Spurious Emissions (Radiated)

SPECIFICATION:
      15.109:            Radiated Interference Limits
      15.33:             Frequency Range of Radiated Measurements
      80.217:            Suppression of Interference Aboard Ships


GUIDE:                      See measurement procedure below

TEST CONDITIONS:            Standard Temperature & Humidity

TEST EQUIPMENT:             As per attached page

SEARCH ANTENNAS:
      100 Hz - 50           MHz:   Emco 3301B Active Rod
        10 kHz - 32         MHz:   Singer 94593-1 Loop
       25 MHz - 300         MHz:   Emco 3109 Biconical
      200 MHz -   1         GHz:   Aprel 2001 Log Periodic
         1 GHz - 18         GHz:   Emco 3115 Horn
       10 GHz - 40          GHz:   Emco 3116 Horn with HP11970A Mixer


                                MEASUREMENT PROCEDURE

1.    At first, bench tests were performed to locate the spurious
      emissions at the antenna terminals.

2.    In the field, tests were conducted over the range shown, The
      test sample was set up on a wooden turntable above ground, and
      at a distance of three meters from the antenna connected tot he
      Spectrum Analyzer.

3.    In order to obtain the maximum response at each frequency, the
      turntable was rotated, and the search antenna was raised and
      lowered. The EUT was also adjusted for maximum response. Tests
      were conducted in Horizontal & Vertical polarization modes.

4.    The field strength was calculated from:

             E µV/m @ 3 m = Log10-1(dBµV + A.F. + C.L.)
                                           20

5.    MEASUREMENT RESULTS: Attached for "Worst Case" conditions.




MFA p0240006, d0250001


                                                                 FCC ID: K66FT-897


PAGE NO.                 7 of 19.

                            RADIATED TEST SETUP




NOTES:
(a)Search Antenna - Rotatable on      (j)Cables routed through hollow
   boom                                  turntable center
(b)Non-metallic boom                  (k)30 cm or less
(c)Non-metallic mast                  (l)External power source
(d)Adjustable horizontally            (m)10 cm diameter coil of excess
(e)Equipment Under Test                  cable
(f)Turntable                          (n)25 cm (V), 1 m-7 m (V, H)
(g)Boom adjustable in height.         (o)25 cm from bottom end of 'V',
(h)External control cables routed        1m normally
   horizontally at least one          (p)Calibrated Cable at least 10m
   wavelength.                           in length
(i)Rotatable                          (q)Amplifier (optional)
                                      (r)Spectrum Analyzer

   Asset   Description                    s/n          Cycle                Last Cal
   (as applicable)                                      Per ANSI C63.4-1992/2000 Draft, 10.1.4


TRANSDUCER
   i00088 EMCO 3109-B 25MHz-300MHz        2336         12   mo.             Sep-01
   i00089 Aprel 2001 200MHz-1GHz          001500       12   mo.             Sep-01
   i00103 EMCO 3115 1GHz-18GHz            9208-3925    12   mo.             Sep-01
   i00065 EMCO 3301-B Active Monopole     2635         12   mo.             Sep-01
AMPLIFIER
   i00028 HP 8449A                        2749A00121   12 mo.              Mar-02
SPECTRUM ANALYZER
   i00029 HP 8563E                        3213A00104   12 mo.              Jan-02
   i00033 HP 85462A                       3625A00357   12 mo.              Jan-02
   i00048 HP 8566B                        2511AD1467    6 mo.              Jan-02
MISCELLANEOUS
   Microphone
   Antenna
   All Ports Terminated



MFA p0240006, d0250001


                                              FCC ID: K66FT-897


PAGE NO.                 8 of 19.

TEST SETUP:              Radiated Emissions




MFA p0240006, d0250001


                                                               FCC ID: K66FT-897


PAGE NO.                  9 of 19.

NAME OF TEST:             Receiver Spurious Emissions (Radiated)


                              MEASUREMENT DETAILS


             SITE REFERENCE                 = 31040/SIT

             SPECTRUM SEARCHED              = 0 to 10 x FR

             WORST CASE                     = V

             LIMITS                         = 15.109(a)      (Attached)

             ALL OTHER EMISSIONS            = 20 dB OR MORE BELOW LIMIT


             TESTS WERE CONDUCTED WITH:

                a. All controls and switches operated.
                b. Half-wave dipole antenna or manufacturer/applicant
                   supplied antenna.


             SAMPLE CALCULATION:

                    EMISSION FREQUENCY, MHz = 0.100000
                    LEVEL = Log10-1 (_21.37_+ 55.2 )
                                             20
                    LEVEL, µV/m @ 0m         = 6737.52


             MEASUREMENT RESULTS            = ATTACHED

             NOTE: WORST CASE OF SCAN AND NON-SCAN MODES REPORTED.




MFA p0240006, d0250001


                                                            FCC ID: K66FT-897


PAGE NO.                 10 of 19.

NAME OF TEST:            Receiver Spurious Emissions (Radiated)

RULE 15.109(a) LIMITS:      FREQUENCY,    FIELD STRENGTH      DISTANCE,
                                MHz            µV/m                m
                              30 - 88           100               3
                              88 - 216          150               3
                             216 - 960          200               3
                             Above 960          500               3
g0240067: 2002-Apr-25 Thu 16:13:00
  FREQUENCY      FREQUENCY       LEVEL,  @ m C.F., dB        µV/m       @ m
 TUNED, MHz    EMISSION, MHz      dBuV
     0.100000     68.430900        16.3     3 12.71           28.22        3
    28.050000     96.380000        17.32    3 13.54           34.91        3
    56.000000    124.330000        10.59    3 16.5            22.62        3
    28.050000    192.760000        12.73    3 18.93           38.28        3
    56.000000    248.612500        12.11    3 21.35            47.1        3

g0240065: 2002-Apr-25 Thu 14:46:00
  FREQUENCY      FREQUENCY     LEVEL,   @ m      C.F., dB    µV/m       @ m
 TUNED, MHz    EMISSION, MHz    dBuV
    76.000000     65.298000      14.09     3      13.35       23.55        3
    92.000000    102.698000      16.87     3      14.48       36.94        3
   108.000000    118.698000        7.92    3      16.02       15.74        3
    76.000000    130.690000      11.2      3      16.71       24.86        3
    92.000000    205.433000        8.54    3      19.55       25.38        3
   108.000000    237.458000      12.22     3      20.91       45.34        3

g0240066: 2002-Apr-25 Thu 15:28:00
  FREQUENCY      FREQUENCY     LEVEL,   @ m      C.F., dB    µV/m       @ m
 TUNED, MHz    EMISSION, MHz    dBuV
   118.000000    186.329500        9.85    3      18.58       26.39        3
   141.000000    209.329500      11.22     3      19.73       35.28        3
   164.000000    232.329500      10.99     3      20.7        38.41        3
   118.000000    372.660000      12.86     3      24.94       77.62        3
   141.000000    418.652500      12.03     3      26.33       82.79        3
   164.000000    464.656000      13.57     3      26.38       99.43        3

g0240064: 2002-Apr-25 Thu 13:07:00
  FREQUENCY      FREQUENCY      LEVEL,  @ m C.F., dB     µV/m    @ m
 TUNED, MHz    EMISSION, MHz     dBuV
   420.000000    488.330000       11.18    3  26.4        75.68    3
   445.000000    513.343000       11.62    3  26.88       84.14    3
   470.000000    538.343000       11.29    3  27.74       89.43    3
   420.000000    976.210000       12.83    3  40.01      438.53    3
   445.000000   1026.210000       12.36    3  36.16      266.69    3
   445.000000   1076.648000       10.39    3  36.82      229.35    3
All other emissions in the required measurement range were more that
20 dB below the required limits.



PERFORMED BY:                               Doug Noble, B.A.S. E.E.T.

MFA p0240006, d0250001


                                                            FCC ID: K66FT-897


PAGE NO.                 11 of 19.

NAME OF TEST:            Scanning Receivers Cellular Band Rejection

SPECIFICATION:           FCC: 47 CFR 15.121(b)

TEST EQUIPMENT:          As per attached page

GUIDE:                   47 CFR 15.121(b): Except as provided in
                         paragraph (c) of this section, scanning
                         receivers shall reject any signals from Cellular
                         Radiotelephone Service frequency bands that are
                         38 dB or higher based upon a 12 dB SINAD
                         measurement, which is considered the threshold
                         where a signal can be clearly discerned from any
                         interference that may be present.

WARNING:                 MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR
                         RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED
                         UNDER FCC RULES AND FEDERAL LAW.

                            MEASUREMENT PROCEDURE
   1. Equipment was connected as illustrated in the block diagram.
   2. A standard signal was applied to the receiver input terminals.
   3. Receiver output audio output was adjusted for rated output and with
       distortion no greater than 10%.
   4. The RF Signal generator was adjusted to produce 12dB SINAD without
       the audio output power dropping by more than 3dB.
   5. This was repeated at three frequencies across all bands to
       establish a reference sensitivity level. The reference sensitivity
       taken was the lowest, or worst-case sensitivity for all of the
       bands.
   6. The output of the signal generator was then adjusted to a level of
       +60dB above the reference level sensitivity established in step 5
       and set to the first of three frequencies in the cellular
       subscriber transmit band.
   7. Receiver squelch threshold, the signal level required to open the
       squelch, should be set to open no greater than +20dB above the
       reference sensitivity.
   8. The receiver was then put in the scanning mode and allowed to scan
       across it’s complete receive range.
   9. If the receiver unsquelched or stopped on any frequency, the
       displayed frequency was recorded. The signal generator was then
       adjusted in output level until a 12dB SINAD from the receiver was
       produced. The signal generator level associated with this response
       was also noted.
   10. This procedure was repeated for three frequencies in the cellular
       base station transmit band.
   11. The difference in between the signal generator output for any
       response recorded and the reference sensitivity is the rejection
       ratio.



MFA p0240006, d0250001


                                                                        FCC ID: K66FT-897


PAGE NO.                  12 of 19.


                              SCANNING RECEIVER:


                                                         Distortion
                                                           Meter




                              RF Signal   Scanning            SINAD
                              Generator   Receiver            Meter




                                                              Audio
                                                              Power
                                                              Meter




Reference Level Sensitivity measured in step 5 =



  Frequency of              Displayed      Level for 12 dB            Rejection, dB
    EUT, MHz             Frequency, MHz      SINAD, dBm

                             848.97
   0.100 – 056               836.4                   < -113              < -130
                             824.04
                             848.97
      76 – 108               836.4                   < -113              < -130
                             824.04
                             848.97
     118 – 164               836.4                   < -113              < -130
                             824.04
                             848.97
     420 - 470               836.4                   < -113              < -130
                             824.04

NOTE: 1) System Sensitivity = -130 dbm

        2) No spurious response detectable within these frequency
           ranges.




PERFORMED BY:                                         Doug Noble, B.A.S. E.E.T.


MFA p0240006, d0250001


                                                             FCC ID: K66FT-897


PAGE NO.                 13 of 19.

NAME OF TEST:            A/C Powerline Conducted Emissions

SPECIFICATION:           FCC: 47 CFR 15.107

GUIDE:                   IEEE Standard 213

TEST CONDITIONS:         S. T. & H.

TEST EQUIPMENT:          As per attached page

                            MEASUREMENT PROCEDURE

1.    A test sample was connected to the Public Utility lines through

      a LISN Ailtech Model 94641-1 (50 µH).



2.    A reference level of 250 µV was set on the Spectrum Analyzer.

      The spectrum was searched over the range of 450 kHz to 30 MHz.



3.    All other emissions were 20 dB or more below limit.


4.       x   The test sample used a charger.
             The test sample does not use a charger.


5.    Measurement Results: Attached.




MFA p0240006, d0250001


                                                                                                FCC ID: K66FT-897


PAGE NO.                   14 of 19.


                     AC POWERLINE CONDUCTED MEASUREMENTS




                 Public                      (2)     Test
                 Utility               (1)




                                                                      A/C Powerline Conducted
                                                    Sample
                  Line




                                       (3)


    Asset   Description                      s/n             Cycle                                   Last Cal
    (as applicable)                                           Per ANSI C63.4-1992/2000 Draft, 10.1.4




(1) LINE IMPEDANCE STABILIZATION NETWORK
   i00077 Singer 91221-1 (5 µH)        0396                  12 mo.
   i00155 Eaton 94641-1 (50 µH)        178                   12 mo.                                  Sep-01
   i00167 Ailtech 94641-1 (50 µH)      0103                  12 mo.



(2) SCREEN ROOM
   i00169 Lindgren 22-2/2-0                  3861            N/A                                     none
   i00170 Lindgren LG170                     4999



(3) SPECTRUM ANALYZER
   i00029 HP 8563E                           3213A00104      12 mo.                                  Jan-02
   i00033 HP 85462A                          3625A00357      12 mo.                                  Jan-02
   i00048 HP 8566B                           2511AD1467       6 mo.                                  Jan-02




MFA p0240006, d0250001


                                                             FCC ID: K66FT-897


PAGE NO.                 15 of 19.

TEST SETUP:              A/C Powerline Conducted Emissions




MFA p0240006, d0250001


                                                           FCC ID: K66FT-897


PAGE NO.                 16 of 19.

NAME OF TEST:       A/C Powerline Conducted Emissions
g0240068: 2002-Apr-30 Tue 11:55:00
STATE: 0:General




                           NEUTRAL SIDE, GROUNDED




PERFORMED BY:                               Doug Noble, B.A.S. E.E.T.


MFA p0240006, d0250001


                                                            FCC ID: K66FT-897


PAGE NO.                 17 of 19.

NAME OF TEST:       A/C Powerline Conducted Emissions
g0240069: 2002-Apr-30 Tue 11:57:00
STATE: 0:General




                             LINE SIDE, GROUNDED




PERFORMED BY:                                Doug Noble, B.A.S. E.E.T.


MFA p0240006, d0250001


                                                            FCC ID: K66FT-897


PAGE NO.                 18 of 19.

NAME OF TEST:       A/C Powerline Conducted Emissions
g0240070: 2002-Apr-30 Tue 12:00:00
STATE: 0:General




                             LINE SIDE, GROUNDED




PERFORMED BY:                                Doug Noble, B.A.S. E.E.T.


MFA p0240006, d0250001


                                                           FCC ID: K66FT-897


PAGE NO.                 19 of 19.

NAME OF TEST:       A/C Powerline Conducted Emissions
g0240071: 2002-Apr-30 Tue 12:02:00
STATE: 0:General




                           NEUTRAL SIDE, GROUNDED




PERFORMED BY:                               Doug Noble, B.A.S. E.E.T.
END OF TEST REPORT

MFA p0240006, d0250001


                                                          FCC ID: K66FT-897




          THE APPLICANT HAS BEEN CAUTIONED AS TO THE FOLLOWING:




15.21        INFORMATION TO USER.


     The users manual or instruction manual for an intentional
radiator shall caution the user that changes or modifications not
expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.



15.27(a)     SPECIAL ACCESSORIES.


     Equipment marketed to a consumer must be capable of complying
with the necessary regulations in the configuration in which the
equipment is marketed. Where special accessories, such as shielded
cables and/or special connectors are required to enable an
unintentional or intentional radiator to comply with the emission
limits in this part, the equipment must be marketed with, i.e.
shipped and sold with, those special accessories. However, in lieu
of shipping or packaging the special accessories with the
unintentional or intentional radiator, the responsible party may
employ other methods of ensuring that the special accessories are
provided to the consumer, without additional charge.


     Information detailing any alternative method used to supply the
special accessories for a grant of equipment authorization or
retained in the verification records, as appropriate. The party
responsible for the equipment, as detailed in § 2.909 of this
chapter, shall ensure that these special accessories are provided
with the equipment. The instruction manual for such devices shall
include appropriate instructions on the first page of text concerned
with the installation of the device that these special accessories
must be used with the device. It is the responsibility of the user
to use the needed special accessories supplied with the equipment.




MFA p0240006, d0250001


                                                           FCC ID: K66FT-897


                         LABELLING OF SCANNING RECEIVERS

'


Scanning receivers shall have a label permanently affixed to the
product, and this label shall be readily visible to the purchaser at
the time of purchase. The label shall read as follows:


      WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR
      RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES
      AND FEDERAL LAW.


"Permanently affixed" means that the label is etched, engrave,
stamped, silkscreened, indelibly printed or otherwise permanently
marked on a permanently attached part of the equipment or on a
nameplate of metal plastic or other material fastened to the
equipment by welding, riveting, or permanent adhesive.    The label
shall be designed to last the expected lifetime of the equipment in
the environment in which the equipment may be operated and must not
be readily detachable.   The label shall not be a stick-on, paper
label.




MFA p0240006, d0250001


                                                          FCC ID: K66FT-897



                           STATEMENT OF COMPLIANCE




THIS IS TO CERTIFY:




             THAT, ON THE BASIS OF THE MEASUREMENTS MADE, THE

             EQUIPMENT TESTED IS CAPABLE OF COMPLYING WITH THE

             REQUIREMENTS OF

                    FCC RULE PART 15, SUBPART B      x_

                    FCC RULE PART 15, SUBPART C   ___

             USING ANSI C63.4-1992/2000 Draft IN EFFECT AS OF THIS

             DATE, UNDER NORMAL OPERATION, WITH THE USUAL MAINTENANCE.



             THAT THE DATA CONTAINED HEREIN IS A SUMMARY (WORST CASE)

             OF THAT OBTAINED ON SEVERAL RANDOMLY-SELECTED PRODUCTION

             SAMPLES.



             THAT THE EQUIPMENT MEETS OR EXCEEDS THE REQUIREMENTS OF

             PART 15.




MFA p0240006, d0250001


                                                           FCC ID: K66FT-897

                           LIST OF EXHIBITS
           (FCC CERTIFICATION (RECEIVERS) - REVISED 9/28/98)


APPLICANT:          Vertex Standard Co., Ltd.


EQUIPMENT:          FT-897
                    K66FT-897



BY APPLICANT:


      IF APPLICABLE: Subsection 2.1033


             1.    LETTER OF AUTHORIZATION


             2.    ATTESTATION


             3.    IDENTIFICATION LABEL DRAWING
                        LABEL
                        LOCATION OF LABEL
                        COMPLIANCE STATEMENT
                        LOCATION OF COMPLIANCE STATEMENT


             4.    DOCUMENTATION: 2.1033(b)

                    (3)   USER MANUAL
                    (4)   OPERATIONAL DESCRIPTION
                    (5)   BLOCK DIAGRAM
                    (5)   SCHEMATIC DIAGRAM
                    (7)   PHOTOGRAPHS




BY M.F.A. INC.

             A.    STATEMENT OF COMPLIANCE

             B.    STATEMENT OF QUALIFICATIONS




MFA p0240006, d0250001



Document Created: 2002-05-06 09:15:17
Document Modified: 2002-05-06 09:15:17

© 2025 FCC.report