Test Report ITU-R M.493-13

FCC ID: K6630653X3D

Test Report

Download: PDF
FCCID_4231001

                                                  TEST REPORT
Report No. ...................................... :       CHTEW19030080                 Report verification :
Project No. ……………………..…….:                                SQ201811002303EW

FCC ID………………………………….:                                     K6630653X3D
IC ……………………………………….:                                      511B- 30653X3D
Applicant’s name ........................... :            YAESU MUSEN CO., LTD.

                                                          Tennozu Parkside Building 2-5-8 Higashi-Shinagawa,
Address ............................................. :
                                                          Shinagawa-ku, Tokyo 140-0002 Japan

                                                          QUANZHOU QIXIANG ELECTRON SCIENCE &
Manufacturer......................................:
                                                          TECHNOLOGY CO., LTD.
                                                          Wan’An Tangxi Industrial Zone, Luojiang District, Quanzhou,
Address..............................................:
                                                          Fujian, China
Test item description .................... :              25 Watt VHF/FM Marine Transceiver

Trade Mark ....................................... :      STANDARD HORIZON

Model/Type reference ....................... :            GX1400GPS
Listed Model(s) ................................. :       GX1400
Standard ......................................... :      ITU-R M.493-13

Date of receipt of test sample……….:                       Mar.01, 2019

Date of testing…………………………:                                Mar.01, 2019- Mar.13, 2019

Date of issue…………………………..:                                Mar.14, 2019
Result……………..…………………...:                                  PASS

Compiled by
( position+printed name+signature) .. :                   File administrators Fanghui Zhu

Supervised by

( position+printed name+signature) .. :                   Project Engineer Edward Pan

Approved by

( position+printed name+signature) .. :                   RF Manager Hans Hu

Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road,
                                                          Tianliao, Gongming, Shenzhen, China
Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd is acknowledged as copyright owner and source
of the material. Shenzhen Huatongwei International Inspection Co., Ltd takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced material due
to its placement and context.
The test report merely correspond to the test sample.



                                                                 Page: 1 of 28


Report No :   CHTEW19030080                   Page:      2 of 28             Issued:   2019-03-14



                                              Contents

1.       T EST ST AN D AR D S AND R E PO RT V E R SIO N                                                   3

1.1.    Test Standards                                                                                3
1.2.    Report version information                                                                    3

2.       T EST D E S CR I PT IO N                                                                         4



3.       SUM M ARY                                                                                        5

3.1.    Client Information                                                                            5
3.2.    Product Description                                                                           5

4.       TEST ENVIRONMENT                                                                                 6

4.1.    Address of the test laboratory                                                                6
4.2.    Test Facility                                                                                 6
4.3.    Environmental conditions                                                                      6

5.       TEST CONDITIONS AND RESULTS                                                                      7

5.1.     Annex 1: General purpose equipment characteristics                                           7
4.1.1    General                                                                                      7
4.1.2    Technical format of a call sequence                                                          8
4.1.3    Dot pattern and phasing                                                                      8
4.1.4    Format specifier                                                                             9
4.1.5    Address                                                                                      9
4.1.6    Category                                                                                     10
4.1.7    Self-identification                                                                          11
4.1.8    Messages                                                                                     11
4.1.9    End of sequence                                                                              14
4.1.10 Error-check character                                                                          14
4.1.11 Distress alert attempt                                                                         15
4.1.12 Shipborne human machine interface (HMI)                                                        15
5.2.     Annex 2: Equipment classes                                                                   17
4.2.1    Equipment classes only apply to shipborne equipment                                          17
4.2.2    Class requirements for B, D and E are given in § 3, 4 and 5 (See Tables 4.1 to 4.10.2 for
technical requirements)                                                                               17
5.3.     Annex 3:Design example User interface for simplified operation of shipborne equipment        18
4.3.1    General                                                                                      18
4.3.2    Definitions                                                                                  18
4.3.3    Controls                                                                                     18
4.3.4    Display of messages in plain language                                                        19
4.3.5    Transmission of DSC messages                                                                 19
5.4.     Annex 4: Design example Automated procedures for simplified operation in shipborne
equipment                                                                                             21
4.4.1 General                                                                                         21
4.4.2 Definitions                                                                                     21
4.2.3 Tasks of automated procedures                                                                   22




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                     Page:    3 of 28               Issued:     2019-03-14



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
ITU-R M.493-13 Digital selective-calling system for use in the maritime mobile service


1.2. Report version information
      Revision No.                Date of issue                              Description
           N/A                     2019-03-14                                  Original




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                    Page:     4 of 28               Issued:    2019-03-14

2. Test Description
                           Annex 1: General purpose equipment characteristics
                                                       Standards requirement
                     Test item                                                   Result      Test Engineer
                                                           ITU-R M.493-13
                      General                                Annex 1§1            Pass       Gaosheng Pan
        Technical format of a call sequence                  Annex 1§2            Pass       Gaosheng Pan
              Dot pattern and phasing                        Annex 1§3            Pass       Gaosheng Pan
                 Format specifier                            Annex 1§4            Pass       Gaosheng Pan
                     Address                                 Annex 1§5            Pass       Gaosheng Pan
                     Category                                Annex 1§6            Pass       Gaosheng Pan
                 Self-identification                         Annex 1§7            Pass       Gaosheng Pan
                    Messages                                 Annex 1§8            Pass       Gaosheng Pan
                 End of sequence                             Annex 1§9            Pass       Gaosheng Pan
               Error-check character                        Annex 1§10            Pass       Gaosheng Pan
               Distress alert attempt                       Annex 1§11            Pass       Gaosheng Pan
    Shipborne human machine interface (HMI)                 Annex 1§12            Pass       Gaosheng Pan
                                        Annex 2: Equipment classes
                                                       Standards requirement
                     Test item                                                   Result      Test Engineer
                                                           ITU-R M.493-13
    Equipment classes only apply to shipborne
                                                             Annex 2§1            Pass       Gaosheng Pan
                    equipment
Class requirements for B, D and E are given in § 3,
4 and 5 (See Tables 4.1 to 4.10.2                            Annex 2§2            Pass       Gaosheng Pan
            for technical requirements)
          Class B (MF and/or VHF only)                       Annex 2§3            Pass       Gaosheng Pan
                Class D (VHF only)                           Annex 2§4            Pass       Gaosheng Pan
           Class E (MF and/or HF only)                       Annex 2§5            Pass       Gaosheng Pan
                                         Annex 3: Design example
                     User interface for simplified operation of shipborne equipment
                                                       Standards requirement
                     Test item                                                   Result      Test Engineer
                                                           ITU-R M.493-13
                      General                                Annex 3§1            Pass       Gaosheng Pan
                    Definitions                              Annex 3§2            Pass       Gaosheng Pan
                     Controls                                Annex 3§3            Pass       Gaosheng Pan
      Display of messages in plain language                  Annex 3§4            Pass       Gaosheng Pan
         Transmission of DSC messages                        Annex 3§5            Pass       Gaosheng Pan
                                         Annex 4:Design example
                Automated procedures for simplified operation in shipborne equipment
                                                       Standards requirement
                     Test item                                                   Result      Test Engineer
                                                           ITU-R M.493-13
                      General                                Annex 4§1            Pass       Gaosheng Pan
                    Definitions                              Annex 4§2            Pass       Gaosheng Pan
         Tasks of automated procedures                       Annex 4§3            Pass       Gaosheng Pan

Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No :     CHTEW19030080                   Page:    5 of 28             Issued:   2019-03-14



3. SUMMARY
3.1. Client Information
Applicant:                    YAESU MUSEN CO., LTD.

                              Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku, Tokyo
Address:
                              140-0002 Japan

Manufacturer:                 QUANZHOU QIXIANG ELECTRON SCIENCE & TECHNOLOGY CO., LTD.
Address:                      Wan’An Tangxi Industrial Zone, Luojiang District, Quanzhou, Fujian, China

3.2. Product Description
Name of EUT:                    25 Watt VHF/FM Marine Transceiver
Trade mark:                     STANDARD HORIZON

Model/Type reference:           GX1400GPS
Listed mode(s):                 GX1400
Power supply:                   DC 13.8V
Hardware Version:               SPP01
Software Version:               SPP01
Marine Radio
                                TX:156.025MHz to 161.600MHz
Operation Frequency Range:
                                RX:156.050MHz to 162.025MHz
Rated Output Power:                High Power:       25W (43.98dBm)       Low Power      1W (30.00dBm)
Modulation Type:                Analog Voice:              PM
                                Digital Data(DSC):         FSK
Channel Separation:             Analog Voice:              25kHz
                                Digital Data(DSC):         25kHz
Emission Designator:            Analog Voice:              16K0G3E
                                Digital Data(DSC):         16K0G2B
Antenna Type:                   External




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                        Page:     6 of 28                    Issued:    2019-03-14

4. TEST ENVIRONMENT

4.1. Address of the test laboratory
Laboratory:Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089


4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No.: 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377B-1

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B-1.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.



4.3. Environmental conditions

            Temperature     15 °C to 35 °C
            Relative
                            20 % to 75 %.
            humidity
Normal
                               Mains voltage               Nominal mains voltage
Conditon
                               Lead-acid battery           1.1 * the nominal voltage of the battery
            Voltage
                                                           the normal test voltage shall be that declared by the
                               Other
                                                           equipment provider

                            VN=nominal Voltage             DC 13.8V
Normal Conditon
                            TN=normal Temperature          25 °C




Shenzhen Huatongwei International Inspection Co., Ltd.                     Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                      Page:   7 of 28                  Issued:   2019-03-14


5. TEST CONDITIONS AND RESULTS
5.1. Annex 1: General purpose equipment characteristics

4.1.1 General
1.   The system is a synchronous system using characters composed from a ten-bit errordetecting
     code as listed in Table 1.
     The first seven bits of the ten-bit code of Table 1 are information bits. Bits 8, 9 and
     10 indicate, in the form of a binary number, the number of B elements that occur in the seven
     information bits, a Y element being a binary number 1 and a B element a binary number 0. For
     example, a BYY sequence for bits 8, 9 and 10 indicates 3 (0 × 4 + 1 × 2 + 1 × 1) B elements in the
     associated seven information bit sequence; and a YYB sequence indicates 6 (1 × 4 + 1 × 2 + 0 × 1)
     B elements in the associated seven information bit sequence. The order of transmission for the
     information bits is least significant bit first but for the check bits it is most significant bit first.

TEST RESULTS: Complies

2.   Time diversity is provided in the call sequence as follows:
     Apart from the phasing characters, each character is transmitted twice in a time-spread
     mode; the first transmission (DX) of a specific character is followed by the transmission of four
     other characters before the re-transmission (RX) of that specific character takes place, allowing for
     a time-diversity reception interval of:
     1) 400 ms for HF and MF channels, and
     2) 331/3 ms for VHF radio-telephone channels.

TEST RESULTS: Complies


3.   The classes of emission, frequency shifts and modulation rates are as follows:
1)   F1B or J2B 170 Hz and modulation rate of 100 Bs (bit/s) ± 30 × 106 for use on HF and MF
     DSC calling channels. When frequency-shift keying is effected by applying audio signals to the
     input of single-sideband transmitters (J2B), the centre of the audio-frequency spectrum offered to the
     transmitter is 1 700 Hz. When a DSC call is transmitted on HF and MF working channels for public
     correspondence, the class of emission is J2B. In this case, audio tones with frequencies 1 700 Hz ± 85
     Hz and modulation rate 100 Bs (bit/s) ± 30 × 106 are used in order for the DSC call to be transmitted.
2)   Frequency modulation with a pre-emphasis of 6 dB/octave (phase modulation) with
     frequency-shift of the modulating sub-carrier for use on VHF channels:
         a) frequency-shift between 1 300 and 2 100 Hz; the sub-carrier being at 1 700 Hz;
         b) the frequency tolerance of the 1 300 and 2 100 Hz tones is ± 10 Hz;
         c) the modulation rate is 1 200 B s (bit/s) ± 30 × 106;
         d) the index of modulation is 2.0 ± 10%.
3)   The radio-frequency tolerances of new designs of both transmitters and receivers in the MF
     and HF bands should be:
         a) coast station: ± 10 Hz,
         b) ship station: ± 10 Hz,
         c) receiver bandwidth: should not exceed 300 Hz.

TEST RESULTS: Complies

4.   The higher frequency corresponds to the B-state and the lower frequency corresponds to the
     Y-state of the signal elements.

TEST RESULTS: Complies

5.   The information in the call is presented as a sequence of seven-bit combinations
     constituting a primary code.
1)   The seven information bits of the primary code express a symbol number from 00 to 127, as
     shown in Table 1, and where:
        a) the symbols from 00 to 99 are used to code two decimal figures according to Table 2;
        b) the symbols from 100 to 127 are used to code service commands (see Table 3).


Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                     Page:    8 of 28                Issued:   2019-03-14

TEST RESULTS: Complies

6.   Where the distress alert repetitions described in § 11 apply, the following conditions are
     considered necessary:
1)   the transmitter encoder must provide repetitive transmission of the call sequence in
     accordance with § 11; and
2)   the receiver decoder should provide maximum utilization of the received signal, including
     use of the error-check character and by using an iterative decoding process with adequate memory
     provision.

TEST RESULTS: Complies

7.   When the transmission of a DSC distress alert is automatically repeated, ships’ DSC
     equipments must be capable of automatically receiving a subsequent distress acknowledgement (see
     Recommendation ITU-R M.541, Annex 1, § 3.1.3.1, 3.1.3.2 and 3.3.5).

TEST RESULTS: Complies


4.1.2 Technical format of a call sequence
1.   The technical format of the call sequence is:




TEST RESULTS: Complies

2.   Examples of typical call sequences and the construction of the transmission format are
     given in Figs. 1 to 3.

TEST RESULTS: Complies

3.   The flow charts illustrating the operation of the DSC system are shown in Figs. 4 and 5.

TEST RESULTS: Complies


4.1.3 Dot pattern and phasing
1.   The phasing sequence provides information to the receiver to permit correct bit phasing and
     unambiguous determination of the positions of the characters within a call sequence (see Note 1).
     NOTE 1 – Acquisition of character synchronization should be achieved by means of character recognition
     rather than, for example, by recognizing a change in the dot pattern, in order to reduce false
     synchronization caused by a bit error in the dot pattern.

TEST RESULTS: Complies

2.   The phasing sequence consists of specific characters in the DX and RX positions
     transmitted alternatively. Six DX characters are transmitted.
1)   The phasing character in the DX position is symbol No. 125 of Table 1.
2)   The phasing characters in the RX position specify the start of the information sequence
     (i.e. the format specifier) and consist of the symbol Nos. 111, 110, 109, 108, 107, 106, 105 and 104
     of Table 1, consecutively.

TEST RESULTS: Complies

3.   Phasing is considered to be achieved when two DXs and one RX, or two RXs and one DX,
     or three RXs in the appropriate DX or RX positions, respectively, are successfully received. These
     three phasing characters may be detected in either consecutive or non-consecutive positions but in
     both cases all bits of the phasing sequence should be examined for a correct 3-character pattern.
     A call should be rejected only if a correct pattern is not found anywhere within the phasing
     sequence.


Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No :    CHTEW19030080                       Page:    9 of 28                   Issued:   2019-03-14

TEST RESULTS: Complies
4. To provide appropriate conditions for earlier bit synchronization and to allow for scanning
   methods to monitor several HF and MF frequencies by ship stations, the phasing sequence should
   be preceded by a dot pattern (i.e. alternating B-Y or Y-B sequence bit synchronization signals) with
   duration of:
1) 200 bits
   At HF and MF for:
       a) distress alerts;
       b) distress acknowledgements;
       c) distress relays addressed to a geographic area;
       d) distress relay acknowledgements addressed to all ships;
       e) all calls addressed to a ship station other than those specified in § 3.4.2.
2) 20 bits
   At HF and MF, for all acknowledgements to individual calls having format specifiers 120 and 123
   and for all calling to coast stations. At VHF for all calls.

TEST RESULTS: Complies


4.1.4 Format specifier
1.The format specifier characters which are transmitted twice in both the DX and RX
  positions (see Fig. 1) are:
  a) symbol No. 112 for a “distress” alert; or
  b)symbol No. 116 for an “all ships” call; or
  c)symbol No. 114 for a selective call to a group of ships having a common interest
    (e.g. belonging to one particular country, or to a single ship owner, etc.); or
  d)symbol No. 120 for a selective call to a particular individual station; or
  e) symbol No. 120 for a selective call to a particular individual station; or
  f)symbol No. 123 for a selective call to a particular individual station using the semiautomatic/automatic
    service.

TEST RESULTS: Complies

   2. It is considered that receiver decoders must detect the format specifier character twice for
   “distress” alerts and “all ships” calls to effectively eliminate false alerting. For other calls, the address
characters provide additional protection against false alerting and, therefore, single
   detection of the format specifier character is considered satisfactory (see Table 3).

TEST RESULTS: Complies


4.1.5 Address
   1. “Distress” alerts and “all ships” calls do not have addresses since these calls are implicitly
   essed to all stations (ship stations and coast stations).

TEST RESULTS: Complies

   2. For a selective call directed to an individual ship, to a coast station or to a group of stations
   having a common interest, the address consists of the characters corresponding to the station’s maritime
   mobile service identity, the sequence consisting of characters coded in accordance withTable 2
   (see Note 1).
   NOTE 1 – According to RR Article 19, maritime mobile service identities are formed of a series of nine
   digits, consisting of three digits of the Maritime Identification Digits (MID) and six more digits.
   These identities are included in the address and self-identification parts of the call sequence and are
   transmitted as five characters C5C4C3C2C1, comprising the ten digits of:
                                  (X1, X2) (X3, X4) (X5, X6) (X7, X8) and (X9, X10)
   respectively, whereas digit X10 is always the figure 0 unless the equipment is also designed in accordance
   with Recommendation ITU-R M.1080.
   Example:
   MID X4 X5 X6 X7 X8 X9 being the ship station identity is transmitted by the DSC equipment as:
                                          (M, I) (D, X4) (X5, X6) (X7, X8) (X9, 0)

TEST RESULTS: Complies

Shenzhen Huatongwei International Inspection Co., Ltd.                    Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                       Page:     10 of 28                 Issued:   2019-03-14



3. For a selective call directed to a group of ships in a particular geographic area a numerical
geographic coordinates address consisting of ten digits (i.e. 5 characters), is constructed as follows
(see Fig. 6 and Note 1):
NOTE 1 – In order to comply with commonly accepted practice, the order of entry and read-out should be:
first latitude and then longitude.

a) the designated geographic area will be a rectangle in Mercator projection;
b) the upper left-hand (i.e. North-West) corner of the rectangle is the reference point for the area;
c) the first digit indicates the azimuth sector in which the reference point is located, as follows:
   1). quadrant NE is indicated by the digit “0”,
   2) quadrant NW is indicated by the digit “1”,
   3) quadrant SE is indicated by the digit “2”,
   4) quadrant SW is indicated by the digit “3”;

TEST RESULTS: Complies

4. the second and third digits indicate the latitude of the reference point in tens and units of
   degrees;

TEST RESULTS: Complies

 5.the fourth, fifth and sixth digits indicate the longitude of the reference point in hundreds,
    tens and units of degrees;

TEST RESULTS: Complies

6. the seventh and eighth digits indicate the vertical (i.e. North-to-South) side of the rectangle,
Δϕ, in tens and units of degrees;

TEST RESULTS: Complies

7.the ninth and tenth digits indicate the horizontal (i.e. West-to-East) side of the rectangle,
Δλ, in tens and units of degrees.

TEST RESULTS: Complies


4.1.6 Category

1. The “category” information is coded as shown in Table 3 and defines the degree of priority
of the call sequence.

TEST RESULTS: Complies

2. For a “distress” alert the priority is defined by the format specifier and no category
   information is included in the call sequence.
a) For distress relays, distress relay acknowledgements and distress acknowledgements the
   category is distress.

TEST RESULTS: Complies

3. For safety related calls, the “category” information specifies:
a)urgency; or
b) safety.

TEST RESULTS: Complies

4. For other calls, the “category” information specifies:
a)routine.

TEST RESULTS: Complies


Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                       Page:    11 of 28                 Issued:   2019-03-14



4.1.7 Self-identification
1. The maritime mobile service identity (MMSI) assigned to the calling station, coded as
   indicated in § 5.2 and its Note 1, is used for self-identification.

TEST RESULTS: Complies


4.1.8 Messages
The messages that are included in a call sequence contain the following message elements, which
are listed in the order in which they would appear in each message. All message formats are
explicitly defined in Tables 4.1 through 4.10.2:

1. For a “distress” alert (see Table 4.1) the distress information is contained in four messages
   in the following order:
a) Message 1 is the “nature of distress” message, coded as shown in Table 3, i.e.:
     1) fire, explosion;
     2) flooding;
     3) collision;
     4) grounding;
     5) listing, in danger of capsizing;
     6) sinking;
     7) disabled and adrift;
     8) undesignated distress;
     9) abandoning ship;
     10) piracy/armed robbery attack;
     11) man overboard;
     12) emergency position-indicating radiobeacon (EPIRB) emission.

b) Message 2 is the “distress coordinates” message, consisting of ten digits indicating the
  location of the vessel in distress, coded on the principles described in Table 2, in pairs starting from
  the first and second digits (see Note 1 to § 5.3):
1) The first digit indicates the quadrant in which the incident has occurred, as follows:
  quadrant NE is indicated by the digit “0”,
  quadrant NW is indicated by the digit “1”,
  quadrant SE is indicated by the digit “2”,
   quadrant SW is indicated by the digit “3”.
2)The next four figures indicate the latitude in degrees and minutes.
3) The next five figures indicate the longitude in degrees and minutes.
4) If “distress coordinates” cannot be included, or if the position information has not been
  updated for 23½ h, the 10 digits following the “nature of distress” should be automatically
  transmitted as the digit 9 repeated 10 times.

TEST RESULTS: Complies

c). Message 3 is the time indication (UTC) when the coordinates were valid consisting of four
   digits coded on the principles described in Table 2, in pairs starting from the first and second digits.
1) The first two digits indicate the time in hours.
2) The third and fourth digits indicate the part of the hours in minutes.
3) If the time cannot be included the four time indicating digits should be transmitted
    automatically as “8 8 8 8”.
4) Message 4 is a single character to indicate the type of communication (telephone or FEC
     teleprinter) which is preferred by the station in distress for subsequent exchange of distress traffic.
     This character is coded as shown in Table 3 first telecommand.

TEST RESULTS: Complies

2. For a distress relay, distress relay acknowledgement, distress acknowledgement (see
Tables 4.2, 4.3 and 4.4) the distress information is contained in five messages in the following order:
a) Message 0 is the “MMSI” of the vessel in distress.
TEST RESULTS: Complies


Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No :    CHTEW19030080                      Page:    12 of 28                Issued:    2019-03-14


b) Message 1 is the “nature of distress” message, coded as shown in Table 3, i.e.:
1)    fire, explosion;
2)    flooding;
3)    collision;
4)    grounding;
5)    listing, in danger of capsizing;
6)    sinking;
7)    disabled and adrift;
8)    undesignated distress;
9)    abandoning ship;
10)   piracy/armed robbery attack
11)   man overboard;
12)   emergency position-indicating radiobeacon (EPIRB) emission.

TEST RESULTS: Complies

c) Message 2 is the “distress coordinates” message, consisting of ten digits indicating the
location of the vessel in distress, coded on the principles described in Table 2, in pairs starting from
the first and second digits (see Note 1 to § 5.3):
1) The first digit indicates the quadrant in which the incident has occurred, as follows:
   quadrant NE is indicated by the digit “0”,
   quadrant NW is indicated by the digit “1”,
   quadrant SE is indicated by the digit “2”,
   quadrant SW is indicated by the digit “3”.
2) The next four figures indicate the latitude in degrees and minutes.
3) The next five figures indicate the longitude in degrees and minutes.
4) If “distress coordinates” cannot be included, or if the position information has not been
updated for 23½ h, the 10 digits following the “nature of distress” should be automatically transmitted as the
digit 9 repeated 10 times.

TEST RESULTS: Complies

d. Message 3 is the time indication (UTC) when the coordinates were valid consisting of four
digits coded on the principles described in Table 2, in pairs starting from the first and second digits.
1)The first two digits indicate the time in hours.
2)The third and fourth digits indicate the part of the hours in minutes.
3)If the time cannot be included the four time indicating digits should be transmitted
 automatically as “8 8 8 8”.

TEST RESULTS: Complies

e. Message 4 is a single character to indicate the type of communication (telephone or FEC
teleprinter) which is preferred by the station in distress for subsequent exchange of distress traffic.
This character is coded as shown in Table 3 first telecommand.

TEST RESULTS: Complies

3.For other types of calls (see Table 4.5 through 4.10.2 and Figs. 2 and 3) messages are
included in the following order:
a. Message 1 is the “telecommand” information and consists of 2 characters (first and second
     telecommand) coded as shown in Table 3;
    a) if no information additional to that conveyed by the first telecommand character is required,
       then the second telecommand signal should be symbol No. 126 (no information) (see Table 3);
    b) if no telecommand information is used, symbol No. 126 is transmitted twice.
    c) If the telecommand 1 is “F3E/G3E duplex TP” (symbol 101) in a request, which can be
       complied with, the telecommand 1 “F3E/G3E all modes TP” (symbol 100) should be used in the
       acknowledgement.

TEST RESULTS: Complies

b Message 2 may contain two “channel or frequency message” elements, each of which
always consists of three characters, “character 1”, “character 2” and “character 3”, indicating the
proposed working frequency (in the F1B/J2B mode the assigned frequency should be used) in multiples of

Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                     Page:    13 of 28               Issued:   2019-03-14

100 Hz or the channel number (coded in accordance with Table 5) or the ship’s position. The first frequency
element (the RX field) in the call indicates the called station receive frequency and the second frequency
element (the TX field) indicates the called station transmit frequency. In acknowledgements the RX and TX
fields indicate the receive and transmit frequency of the acknowledging station respectively (see also Fig. 2
and Note 1).
NOTE 1 – If only one channel or frequency message element is used, this indicates the called station receive
channel or frequency or a two-frequency (paired) channel. A second channel or frequency message element
may be used to designate the called station transmit channel or frequency. If the calling station indicates only
the called station receive frequency (for broadcast mode transmissions) then the symbol No. 126 repeated
three times should be transmitted instead of the called station transmit channel or frequency message
element. If no “channel or frequency message” elements are used, the symbol No. 126 is transmitted six times.
For calls using the semi-automatic/automatic VHF service (see Table 4.10.1) then only one “channel
or frequency message” element is transmitted which indicates the paired channel number. In the absence of
this element the symbol No. 126 should be transmitted three times.

TEST RESULTS: Complies

c. Frequency information
The frequency (in the F1B/J2B mode the assigned frequency should be used) in multiples of 100 Hz
may only be indicated as such when the frequency is below 30 MHz. The three characters provide
for the required six decimal digits. Character 1 represents the units (U) and tens (T) of 100 Hz,
character 2 the hundreds (H) and thousands (M) and character 3 the tens of thousands (TM) and hundreds of
thousands (HM) of 100 Hz. For MF/HF DSC, use frequency selection mode, vice
channel selection mode, to ensure international interoperability.

TEST RESULTS: Complies

d. Channel information
a) HF and MF channels
If the HM digit is 3, this indicates that the number represented by the digits TM, M, H, T and U is the HF/MF
working channel number (either single frequency or two frequency channels). This mode should only be used
for decoding received calls, to ensure interoperability with older equipment.
b) VHF channels
If the HM digit is 9, this indicates that the number represented by the values of the digits M, H, T
and U is the VHF working channel number. If the M digit is 1, this indicates that the ship stations
transmitting frequency is being used as a simplex channel frequency for both ship and coast
stations. If the M digit is 2, this indicates that the coast stations transmitting frequency is being used
as a simplex channel frequency for both ship and coast stations.
c) Ship’s position information
For MF/HF calls, Message 2 may contain the ship’s position, consisting of the digit 5
repeated two times and ten digits (five characters) indicating this position, coded in accordance with
§ 8.1.2 to § 8.1.2.3 (see Table 6).
For position requests message 2 consists of 6 no information symbols
(symbol No. 126).
In acknowledgements to a call requesting ship’s position (see Fig. 3d)) message 2
consists of twelve digits (six symbols), the first of which should be coded in accordance with
§ 8.1.2 to § 8.1.2.3 followed by one symbol No. 126.
Message 3 follows message 2 in this case and contains the time (UTC) when the coordinates were
valid, coded as indicated in § 8.1.3 to § 8.1.3.3.

TEST RESULTS: Complies

e. Message 3 follows message 2 when using the DSC system for calls initiated by ship
stations requiring a semi-automatic or automatic connection (see Table 4.10.1 and 4.10.2) and
contains the public switched network number (e.g. telephone number). In this case the format
specifier used is symbol No. 123.
a)This number is coded by up to nine symbols in a manner similar to that shown in Table 2, except that the
first character transmitted should be either symbol No. 105 or No. 106 to indicate whether the network number
contains an odd or even number of significant digits. As an example, the number 0012345 would be coded as
symbol numbers 105 00 01 23 45 whereas the number 00123456 should be coded as symbol numbers 106
00 12 34 56.

TEST RESULTS: Complies


Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                     Page:    14 of 28                Issued:   2019-03-14

f. For “distress relay” including shore-to-ship alerts, “distress relay acknowledgement” and “distress
acknowledgement” calls, the message formats are indicated in Tables 4.3, 4.4 and 4.2 respectively.
a) When sending a distress alert on behalf of another ship which is unable to send its own alert, and where
the identity of the station in distress is unknown, the distress relay call should contain the symbol No. 126
transmitted five times for the “identification of the station in distress”.

TEST RESULTS: Complies

g.Test calls
Test calls on the distress and safety frequencies for MF and HF and VHF channel 70 may be
conducted using the test call sequence in Table 4.7.

TEST RESULTS: Complies


4.1.9    End of sequence
The “end of sequence” (EOS) character is transmitted three times in the DX position and once
in the RX position (see Fig. 1b)). It is one of the three unique characters corresponding to
symbol Nos. 117, 122 and 127 as follows:

1. symbol No. 117 if the call requires acknowledgement (Acknowledge RQ), used for
   individual and automatic/semiautomatic calls only;

TEST RESULTS: Complies

2. symbol No. 122 if the sequence is an answer to a call that requires acknowledgement (Acknowledge BQ),
   used for individual and automatic/semiautomatic calls and all distress relay acknowledgements;

TEST RESULTS: Complies

3. symbol No. 127 for all other calls.

TEST RESULTS: Complies


4.1.10 Error-check character
1. The error-check character (ECC) is the final character transmitted and it serves to check the entire
   sequence for the presence of errors which are undetected by the ten-unit error-detecting code and the time
   diversity employed.

TEST RESULTS: Complies

2.The seven information bits of the ECC shall be equal to the least significant bit of the modulo-2 sums of the
  corresponding bits of all information characters (i.e. even vertical parity). The format specifier and the EOS
  characters are considered to be information characters. The phasing characters and the retransmission (RX)
  characters shall not be considered to be information characters. Only one format specifier character and
  one EOS character should be used in constructing the ECC. The ECC shall also be sent in the DX and RX
  positions.

TEST RESULTS: Complies

3. Automatic acknowledgement transmissions should not start unless the ECC is received and decoded
correctly. A received ECC which does not match that calculated from the received information characters may
be ignored if this was due to an error detected in the ten-unit error-detecting code of the information
characters which was correctable by use of the time diversity code.

TEST RESULTS: Complies

4.The receiver decoder should provide maximum utilization of the received signal, including
use of the error-check character.

TEST RESULTS: Complies



Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                      Page:    15 of 28                 Issued:   2019-03-14




4.1.11 Distress alert attempt
1.Distress alerts may be transmitted as a single frequency or a multi-frequency call attempt preceded by a dot
  pattern. MF/HF equipment should be capable of using both single and multifrequency call attempts. Where
  a distress alert attempt contains more than one consecutive distress alert on the same frequency (see
  Recommendation ITU-R M.541, Annex 1, § 3.1.3), these consecutive alerts should be transmitted with no
  gap between the end of one call and the start of the dot pattern of the following call to enable bit
  synchronization to be maintained (see Fig. 1c)). Multi-frequency call attempts should always include at least
  the MF and HF 8 MHz band DSC distress and safety frequencies.

TEST RESULTS: Complies

2.A distress alert should be activated only by means of a dedicated distress button which should be clearly
 identified and be protected against inadvertent operation with a spring loaded lid or cover. The initiation of a
 distress alert should at least require two independent actions.

TEST RESULTS: Complies

3.Calls with format specifier “distress” or category “distress”, “urgency” and “safety” should be initiated
 manually only. This applies also for ships equipped for automatic DSC operation. For automatic repetition of
 distress alerts see Recommendation ITU-R M.541, Annex 1, § 3.1.3 and 3.3.5.

TEST RESULTS: Complies

4.Immediately following a distress alert a DSC expansion message giving enhanced position resolution
 according to Recommendation ITU-R M.821 should be transmitted in the following manner.
a. For a single frequency distress alert attempt the expansion message should be transmitted
immediately after the last of five consecutive distress alerts.

TEST RESULTS: Complies

b.For a multi-frequency distress alert attempt the expansion message should be transmitted
immediately after each distress alert.

TEST RESULTS: Complies



4.1.12 Shipborne human machine interface (HMI)
1.Shipborne aural alarm
Shipborne alarms should start softly and increase in volume if not silenced by the operator. This will give the
operator the opportunity to acknowledge the alarm without interrupting the ship’s current communications. It
should be possible for the operator to disable all audible alarms except those of distress, priority and urgency.
Distress and urgency calls should have a distinctive two tone alarm. The alarm should consist of two
substantially sinusoidal audio-frequency tones, transmitted alternately. One tone should have a frequency of 2
200 Hz and the other a frequency of 1 300 Hz. The duration of each tone should be 250 ms.
Distress calls and urgency calls should activate an alarm. For HF and MF distress calls, the alarm should
activate only when a distress alert, distress acknowledgement, or a distress relay is received and the distress
position is within 500 nm (926 km) of the receiving vessel’s position, or if the distress position is in the polar
areas (latitude greater than 70° N or 70° S). The alarm should also activate when the call is received and
the distance between the vessel in distress and the receiving vessel cannot be determined.
NOTE 1 – Disabling of aural alarm does not affect handling of call.
For geographic area calls, the alarm appropriate to the category should activate when the receiving station’s
position is within the area specified by the call or the receiving station’s position is not known. The alarm
should not be activated where duplicate distress relay calls are received within one hour. A duplicate distress
relay call is one having format specifier all ships or geographic area that contains identical message
information, as defined in § 8.1 and an identical distress MMSI.

TEST RESULTS: Complies

Shenzhen Huatongwei International Inspection Co., Ltd.                 Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                     Page:    16 of 28                Issued:   2019-03-14


2. Inactivity timer
During normal operation, the equipment should include an inactivity timer to return the DSC
system display to default or standby mode if the operator is in a menu where DSC call reception is
disabled and does not make any selections or changes for 10 min.

TEST RESULTS: Complies

3. Display
The information on the display should be visible in all shipboard lighting conditions. It should have the means
to display, in plain language, the information contained in the received call. For Class A/B DSC equipment, the
display should have a minimum of 160 characters in two or more lines.

TEST RESULTS: Complies

4.MMSI
DSC equipment should not transmit any DSC call until own ship’s MMSI allocated to the ship by the relevant
administration has been configured and stored in the DSC equipment. Once stored, it should not be possible
for the user to change the MMSI without advice from the manufacturer.
The DSC equipment should display own ship’s MMSI on start-up unless the MMSI has not been configured. If
the MMSI has not been configured, the equipment will display a warning that the unit will not transmit any
DSC calls until own ship’s MMSI is entered. The equipment should stay in this state until the operator confirms
he has read the display and input own ship’s MMSI.
The MMSI should be readily displayed on the HMI when the DSC equipment is on.

TEST RESULTS: Complies

5.Disabling of DSC automatic channel switching function on VHF Automatic switching to a subsequent
communications channel on receipt of a DSC call might in some cases disrupt important ongoing
communications. Where such capability exists, a means for disabling that function should therefore be
provided for all calls other than individual station calls of category distress or urgency. The DSC equipment
should provide visual indication that the automatic switching function is disabled.

TEST RESULTS: Complies

6.Data interface
DSC equipment should be provided with facilities for exchange of data from shipborne navigational
equipment or systems, or other shipborne equipment as necessary in accordance with IEC 61162 for
purposes including automatic position updating.

TEST RESULTS: Complies

7. Position updating
DSC equipment should accept valid IEC 61162 position information including the time at which the position
was determined, from an external source utilizing the data interface described in § 12.6, for automatic update
of own ship’s DSC position.
The DSC equipment may also be provided with an internal electronic position fixing device. In which case, the
DSC equipment should automatically switch to the internal source if the external IEC 61162 position
information is not valid or not available.
If the automatic position update is not available, a displayed and audible reminder to manually update the
position should occur before the position information is 4 h old. The displayed reminder should remain until
position updating has been carried out. Any position information not updated for more than 23½ h should
automatically be erased.
Own ship’s DSC position information and the source of that information (external, internal, or
manually entered) should be displayed on the DSC equipment.

TEST RESULTS: Complies

8.Geographic area entry
DSC equipment should be provided with means for transforming a geographical area specified by the user as
a centre point and a range to the corresponding Mercator area call format specified in § 5.3. The centre point
should default to the ships position information and the range should default to 500 nm (926 km). The
transformation of the entered range and centre-point should result in the minimum rectangular area that
encompasses the entered data.

Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                      Page:    17 of 28                 Issued:   2019-03-14

TEST RESULTS: Complies

9.Medical transport and neutral ships and aircraft
The capability of using second telecommands “Ships and aircraft of States not parties to an armed conflict”
and “Medical Transports” should not be available by default but only after changing relevant parameters in the
setup menu.

TEST RESULTS: Complies



5.2. Annex 2: Equipment classes

4.2.1 Equipment classes only apply to shipborne equipment
    Class D equipment is intended to provide minimum facilities for VHF DSC distress, urgency and
    safety as well as routing calling and reception, not necessarily in full accordance with IMO GMDSS
    carriage requirements for VHF installations.

TEST RESULTS: Complies


4.2.2 Class requirements for B, D and E are given in § 3, 4 and 5 (See Tables 4.1 to
      4.10.2 for technical requirements)
    1. Class D (VHF only)
    1) Transmit capabilities
            Format specifier:
            a) Distress
            b) All ships
            c) Individual station
            d) Ships having common interest (group)
    2) The numerical identification of the called station (address).
            a) Category:
            b) Distress
            c) Urgency
            d) Safety
            e) Routine
    3) Self-identification (automatically inserted).
    4) Messages
            a) For distress calls:
                 i.    Message 1: Nature of distress, defaulting to undesignated distress
                ii.    Message 2: Distress coordinates
               iii.    Message 3: Time for last position update
               iv.     Message 4: Type of subsequent communication: F3E/G3E simplex.
            b) For all other calls:
                 i.    First telecommand:
                       F3E/G3E simplex
                       Unable to comply
                       Polling.
                ii.    Second telecommand: No information.
               iii.    Frequency/channel information:
                       VHF working channel, defaulting to channel 16 for urgency
                       and safety calls and a recognized intership channel
                       (RR Appendix 18) for all other calls.
    5)   End of sequence character: As defined in Annex 1.

TEST RESULTS: Complies

    6) Receive capabilities
       Receive and be capable of displaying all the information in calls listed in § 4.1 plus all distress relay
       calls except those having the format specifier “geographical area calls”, all distress
       acknowledgement calls and all “unable to comply” calls.

TEST RESULTS: Complies

Shenzhen Huatongwei International Inspection Co., Ltd.                 Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                     Page:    18 of 28                 Issued:   2019-03-14

5.3. Annex 3:Design example User interface for simplified operation of shipborne
     equipment

4.3.1 General
    The user interface for operation of the DSC equipment should be so designed that it will be easy for
    the operator onboard the ship to operate the equipment and to compose and initiate the types of
    DSC messages provided for by the equipment. The equipment software should allow the operator to
    only compose the types of DSC messages which are specified in Tables 4.1-4.10.2. These tables
    indicate which DSC messages are applicable for each class of DSC equipment.

TEST RESULTS: Complies


4.3.2 Definitions
    1. Automated procedure: the term given to describe the set of actions necessary to complete
       the objective of an initiating DSC message or non-DSC communication event. Four DSC automated
       procedures are designed to process these. They are the receiving of distress DSC messages, the
       receiving of non-distress DSC messages, the sending of distress DSC alert attempts and the sending
       of non-distress DSC messages. In addition a fifth procedure is designed to handle non-DSC
       communication events.
       These automated procedures are called:
       1) Received distress automated procedure
       2) Sending distress automated procedure
       3) Received non-distress automated procedure
       4) Sending non-distress automated procedure
       5) Communications automated procedure.
    2. default:
       a value selected or an action taken by the equipment software in the absence of any operator input.
    3. DROBOSE: distress relay on behalf of someone else.
    4. engaged: the term used to indicate that the equipment is busy handling an automated procedure.
    5. factory default: a default value that is set by the manufacturer such that the field or behaviour is
         defined prior to any operator intervention.
    6. standby: the term used to indicate that the equipment is not handling an automated procedure, either
         active or on hold, but is able to receive DSC messages.
    7. top level: top level means that items, buttons, or functions are present and visible without
       requiring any action by the operator (such as scrolling, opening up menus, or removing any obscuring
       covers, etc.).

TEST RESULTS: Complies


4.3.3 Controls
    1. Dedicated distress button to initiate the sending of the distress alert attempt. This button
        should have at least two independent actions. Lifting of the protective lid is considered the first
        action. Pressing the distress button is considered as the second independent action. This button
        should be red in colour and marked “DISTRESS”. Where a non-transparent protective lid or cover
        is used, it should also be marked “DISTRESS”. The cover should be protected against inadvertent
        operation with a spring loaded lid or cover permanently attached to the equipment by e.g. hinges. It
        should not be necessary for the user to remove seals or to break the lid or cover in order to operate
        the distress button. This button should be used only for this purpose and it should be able to perform
        this function at all times. Use of the button without any previous operator actions to compose the
        alert should initiate the default distress alert attempt. The “default distress alert attempt” consists of
        “undesignated” for the nature of distress, radiotelephony for the communication mode, and on HF
        the transmission of the attempt uses the multifrequency method including all six bands.
        The distress button should have priority over all DSC procedures.

    2. The following controls, buttons or functions should be provided and visible at the top level
       while the equipment is in standby:
       1) Distress function for composing distress alert attempts other than the default distress alert
            attempt where the operator is able to:
            a) select the nature of distress (the factory default should be undesignated distress),
            b) on HF select the communication mode (the factory default should be telephone),
            c) on HF select the method and frequencies of transmission (the factory default should be the
Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                       Page:    19 of 28                  Issued:   2019-03-14

                 multifrequency method on all six bands),
            d) check the content of the position and time of position information and to manually enter
                 this information if not correct, prior to initiating the sending of the distress alert attempt with
                 the dedicated distress button.
       2) Call function for composing non-distress DSC messages.
       3) Distress relay on behalf of someone else function for composing and relaying the
           occurrence of a distress event obtained by non-DSC means.
    3. The following controls, buttons or functions should be provided and be visible as noted:
       1) Cancel/esc/exit/or equivalent for returning to a previous menu level from any state of the
           equipment.
       2) Enter/accept/next/touch/press or equivalent for:
            a) Accepting a menu item, or
            b) Going to the next step.

TEST RESULTS: Complies


4.3.4 Display of messages in plain language
     The headings and content of messages should be shown in plain language, for example:
     1) “Radiotelephone” instead of J3E,
     2) “busy” instead of “telecommand 2: 102”.

TEST RESULTS: Complies


4.3.5 Transmission of DSC messages
    1. DSC message composition features
        The facilities for choosing and composing DSC messages should be so arranged that it is possible for
        the operator quickly and precisely to:
     1) compose the content of the DSC message,
     2) review and correct, if needed, the content before transmitting the DSC message.

TEST RESULTS: Complies

    2. Operational guidance to the operator
     1) The operator should only be able to compose the types of DSC messages which are
        specified in Tables 4.1-4.10.2.
     2) The equipment should automatically propose the next step for composing the DSC
        message, for example, when pressing the enter/accept/next/touch/press button or equivalent, if not
       visible from the context or on the display.

TEST RESULTS: Complies

    3. Defaults
       Where options for the items in the DSC message exist (see Annex 1, Tables 4.1-4.10.2), the factory
       default values should be as follows:
       After the operator selects the option to compose a non-distress DSC message:
     1) if the operator has the option to select a format (destination address) the default format
        should be “individual (120)”,
     2) if the format (destination address) is either individual (120), a group of ships (114), or a
        semi-automatic phone call (123), the default MMSI should be some internal indicator that
          the MMSI is invalid and needs to be entered before transmission can occur,
     3) if the format (destination address) is an area (102), the default area should be a circle of
        radius 500 nautical miles centred on the ship,
     4) if the operator has the option to select a category (priority) the default category should be
        “routine” unless the routine priority is not allowed (such as in an area or all-ships DSC
            message) in which case it should be “safety”,
     5) if the operator has the option to select the type of subsequent communication the default
        value should be radiotelephony,
     6) if the operator has the option to select a frequency or channel for the subsequent
        communication the default value should be a non-distress frequency or channel consistent
       with the means of subsequent communication and on MF/HF in the same band as the DSC
            message transmission,
     7) on MF/HF if the operator has the option to select the frequency of the DSC

Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                    Page:     20 of 28              Issued:   2019-03-14

           transmission, default value should be 2 177 kHz,
     8) on MF if the operator has the option to select the frequency of the DSC transmission,
           default value should be 2 177 kHz,
     9) on HF if the operator has the option to select the frequency of the DSC transmission,
           default value should be in the 8 MHz band,
     10) all other parameters, for example the position, self ID, time of position, and end of
           sequence character, should be automatically entered by the equipment,
     11) the category should not be “remembered” when the call composition option is selected at a
           later time but should be reset to the factory default; this requirement does not mean the
           equipment is unable to provide the operator with the option to send pre-composed,
           customized DSC messages with a single action,
     12) for example, if there is only a single “call” button, menu selection, or equivalent for
           initiating a non-distress DSC message, the default DSC message should have format
           “individual” and category “routine”.
       After the operator selects the option to compose a distress relay on behalf of someone else
       (DROBOSE):
     1) if the operator has the option to select a format (destination address) the default format
           should be “individual (120)”,
     2) if the format (destination address) is individual (120), the default MMSI should be some
           internal indicator that the MMSI is invalid and needs to be entered before transmission can
           occur,
     3) if the format (destination address) is an area (102), the default area should be a circle of
           radius 500 nautical miles centred on the ship,
     4) the default nature of distress should be “undesignated (107)”,
     5) the default MMSI for the vessel in distress should be “unknown (five 126s)”,
     6) the default position and time of position should be unknown,
     7) the default means of subsequent communication should be radiotelephony,
     8) on MF/HF the default band of the DSC transmission should be on the 2 MHz band,
     9) on MF the default band of the DSC transmission should be on the 2 MHz band,
     10) on HF the default band of the DSC transmission should be on the 8 MHz band,
     11) all other parameters, for example the, self ID, the distress relay telecommand 1 parameter,
           the category (distress), and end of sequence character should be automatically entered by
     12) the equipment,
     13) the format, MMSI of the vessel in distress, the nature of distress, the position and time of
           position should not be “remembered” when the DROBOSE composition option is selected
           at a later time but should be reset to the defaults.

TEST RESULTS: Complies

    4. Other items
     1) If the called station is a ship station or a group of ship stations the equipment should request
        input of a channel number (frequency in case of MF). The equipment should assist the operator by
        suggesting a suitable inter-ship channel; on VHF for example channel 6.
     2) Automated HF subsequent communication channel selection for non-distress DSC
        messages. There is a simplex set and duplex set (contains the distress channels) for HF for both
       voice (3 000 Hz) and data (500 Hz) communication modes. Selection of the appropriate channel
       from these sets should follow the following steps:
              a) The band of the communication channel should be the band of the DSC message.
              b) The telecommand 1 parameter determines the choice of voice or data channels.
              c) DSC messages directed to a coast station (i.e. MMSI commencing 00) should let the coast
                   station decide.
              d) All other DSC messages should select a channel from the simplex frequencies.
     3) Use of the distress channels should be avoided and for routine communications use of the distress
            channels should not be allowed.

TEST RESULTS: Complies




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                   Page:      21 of 28             Issued:   2019-03-14



5.4. Annex 4: Design example Automated procedures for simplified operation in
     shipborne equipment

4.4.1 General
         The equipment software should allow the operator to only compose the types of DSC messages
         which are specified in Tables 4.1-4.10.2. These tables indicate which DSC messages are applicable
         for each class of DSC equipment.
         Automated procedures are the incorporation of ITU-R recommended DSC operational procedures
         into equipment software.
         The equipment should initiate (start) one of five automated procedures whenever the equipment
         becomes engaged in a new communication event. Four of these automated procedures handle
         events initiated by sent and received DSC messages and the fifth automated procedure handles
         radiotelephony established by non-DSC means. One of these five automated procedures is initiated
         by:
          a) sending a distress alert,
          b) receiving a DSC message containing distress information,
          c) sending an individually addressed relay containing distress information,
          d) sending distress relay on behalf of someone else,
          e) sending a DSC message containing no distress information,
          f) receiving a DSC message containing no distress information,
          g) engaging in traffic initiated by non-DSC means.
       Once initiated by any of the events listed in a)-g), the automated procedure should handle all the
       tasks required to satisfy the objectives of the initiating event. These tasks should include the
       handling of any subsequent DSC messages that may be pertinent (relevant) to the objectives of the
       automated procedure and appropriately updating the automated procedure, providing the operator
       with any possible options, and keeping the operator informed of the progress until either the
       operator terminates the automated procedure or conditions warrant that the automated procedure
       self terminates. Automated procedures should be able to be run in parallel. Whereas all DSC
       automated procedures continuously monitor the watch receiver only one active automated
       procedure has control of the transmitter and general receiver. The reception of any DSC message
       not pertinent to an automated procedure should not disrupt that procedure but should be
       appropriately allocated to the appropriate ongoing automated procedure or initiate a new automated
       procedure

TEST RESULTS: Complies


4.4.2 Definitions
         1.   acknowledged: when used to describe an automated procedure it indicates that the
              objective of the initial DSC message has been achieved.
         2.   active: the term used to describe an automated procedure which has control of the general
              receiver and transmitter and is thus able to engage in subsequent communications and receive
              DSC messages on both the watch receiver and general receiver.
         3.   automated procedure: the term given to describe the set of actions necessary to complete
              the objective of an initiating DSC message or non-DSC communication event. Four DSC
              automated procedures are designed to process these. They are the receiving of distress DSC
              messages, the receiving of non-distress DSC messages, the sending of distress DSC alert
              attempts and the sending of non-distress DSC messages. In addition a fifth procedure is
              designed to handle non-DSC communication events.
              These automated procedures are called:
                a) Received distress automated procedure
                b) Sending distress automated procedure
                c) Received non-distress automated procedure
                d) Sending non-distress automated procedure
                e) Communications automated procedure.
         4.   critical errors: a set of information characters obtained from one or more received DSC
              messages is considered to have critical errors if the automated procedure needs information
              characters from that set in order to proceed or perform any task, but the required information
              characters are in error (for example, an acknowledgement cannot be composed to an individual
              DSC message that has errors in the sender’s MMSI).
         5.   default: a value selected or an action taken by the equipment software in the absence of any
              operator input.
Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No :    CHTEW19030080                     Page:    22 of 28                 Issued:   2019-03-14

         6.    distress DSC message: A DSC message or acknowledgement containing the distress
               information.
         7.    distress event: a unique distress situation identified by two (VHF) or three (MF/HF)
               parameters of the distress information; the MMSI of the vessel in distress and the nature of
               distress and on MF/HF the mode of subsequent communication.
         8.    distress information: the symbols within a DSC message describing a distress situation
               consisting of the MMSI of the vessel in distress, the nature of distress, the position of the vessel
               in distress, the UTC time of that position, and the mode of subsequent communication.
         9.    DROBOSE: distress relay on behalf of someone else.
         10.   DX/RX: a notation used to describe the time diversity structure of DSC messages (see
               Fig. 1). One has to be careful not to confuse the “RX” notation when used to indicate the symbol
               position in the DSC message structure (as in § 4.1 of Annex 1) with its use to indicate reception
               (as in § 8.3.2 of Annex 1).
         11.   engaged: the term used to indicate that the equipment is busy handling an automated
               procedure.
         12.   factory default: A default value that is set by the manufacturer such that the field or
               behaviour is defined prior to any operator intervention.
         13.   general receiver: this unit is the receiver part of the transceiver used for the reception of all
               subsequent communications and on HF the reception of non-distress DSC acknowledgements.
               It is important to distinguish this unit from the watch receiver (see below).
         14.   identical: a set of information characters is considered identical to another set of
               information characters if all pairs of corresponding information characters are equal or, if a pair
               of corresponding information characters is not equal, one of the pair is in error.
         15.   information characters: the set of symbols in the DSC message that contain the items of
               interest for the recipient and is used to compute the ECC symbol that terminates the message.
               These symbols are repeated in the DX/RX time diversity pattern.
         16.   initial DSC message: the DSC message that starts an automated procedure.
         17.   non-distress DSC message: DSC messages and acknowledgments that do not contain the
               distress information.
         18.   objective: when in reference to a DSC message or automated procedure it is the goal or
               intent of the item; usually this goal or intent is to establish subsequent communications or
               request information.
         19.   on hold: the term used to describe an automated procedure which does not have access to
               the transmitter and general receiver and therefore cannot engage in subsequent
               communications and is only able to receive DSC messages on the watch receiver.
         20.   operator options: are any choices the operator can make while the automated procedure is
               engaged.
         21.   parallel event handling: the background process of handling a received DSC message that
               is not pertinent to the active automated procedure.
         22.   pertinent to the automated procedure: an expression used primarily with reference to
               DSC messages to indicate that the message has something to do with the procedure and is
               therefore“handled” by the procedure. A DSC message is pertinent to an automated procedure if
               the set of information characters in the DSC message has the correct values.
         23.   standby: the term used to indicate that the equipment is not handling an automated
               procedure, either active or on hold, but is able to receive DSC messages.
         24.   two-tone alarm: an alarm consisting of a repetition of the 2 200 Hz frequency for 250 ms
               followed by a 1 300 Hz frequency for 250 ms. This alarm is used for the initiation of the received
               distress DSC automated procedure. The characteristics of this alarm should not be able to be
               altered.
         25.   urgency alarm: an alarm consisting of a repetition of the 2 200 Hz frequency for 250 ms
               followed by 250 ms period of silence. This alarm is used for the initiation of the received
               non-distress DSC automated procedure when the category of the initiating DSC message is
               “urgency”. The characteristics of this alarm should not be able to be altered.
         26.   watch receiver: this unit is the separate receiver in DSC radios that continuously monitors
               the DSC distress frequencies on MF/HF, 2 187.5 kHz on MF, and channel 70 on VHF. On
               MF/HF it is sometimes referred to as the scanning receiver.

TEST RESULTS: Complies


4.2.3 Tasks of automated procedures
               1.   Tasks common to all automated procedures handling DSC messages
                    1) Handling alarms
                        a) The sounding of any alarm should simultaneously display the reason for the

Shenzhen Huatongwei International Inspection Co., Ltd.                 Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                    Page:    23 of 28               Issued:   2019-03-14

                           alarm and the means to silence it.
                       b)  Alarms should sound appropriate to the automated procedure when a received
                           DSC message either initiates or acknowledges the automated procedure with the
                           two-tone alarm being reserved for the initiation of the received distress procedure,
                           and the urgency alarm being reserved for the initiation of the received non-
                           distress procedure when the category of the initiating DSC message is “urgency”.
                     c) Only the first occurrence of a received DSC message should sound the alarms
                           described in § 3.1.1.2.
                     d) All received DSC messages that do not sound an alarm as specified in § 3.1.1.2
                           should sound a brief, self-terminating alarm to inform the operator of the
                           reception.
                2) Displaying stages of the automated procedure
                     The automated procedure should display the stages and/or activity in order to indicate
                     the progress of the procedure.
                3) Tuning the radio
                     a) Tuning of the general receiver and transmitter for reception or transmission of
                           required acknowledgments, repeat transmissions, relays, or subsequent
                           communications should be handled automatically.
                     b) Any automated tuning action that could potentially disrupt ongoing subsequent
                           communications should provide the operator with at least a 10 s warning. The
                           operator should then be provided with the opportunity to pause the action. In the
                           absence of operator intervention the automated action should proceed.
                4) Displaying operator options
                     Options should only be provided at those times the option is appropriate.
                5) Handling DSC messages not pertinent to the active procedure
                     The received DSC message is either allocated to the correct automated procedure
                     running in the background on hold or initiates a new automated procedure on hold.
                6) Displaying warnings
                     Warnings should be displayed when the operator attempts to do anything that does
                     not follow the guidelines given by ITU and IMO. The operator should have the option
                     to go back to the stage of the automated procedure where the action was taken that
                     caused the warning.
                7) Handling DSC messages containing errors
                     a) A DSC message with errors is pertinent to an automated procedure if the set of
                           information characters in the DSC message is identical as defined in the
                           “definitions” section to the set of information characters normally used to
                           determine pertinence.
                     b) Automated procedures initiated by DSC messages with critical errors should
                           sound the same alarm they would sound if the DSC message were received error
                           free but the alarm should self-terminate.
                     c) Automated procedures are encouraged to utilize subsequent DSC messages
                           pertinent to the automated procedure to reduce the number of receive errors in
                           the set of information characters that are important to the automated procedure.
                           In no case should the reception of subsequent DSC messages increase the
                           number of errors in the set of information characters important to the automated
                           procedure.
                     d) No automated procedure should allow the transmission of further DSC messages
                           with errors.
                     e) If critical errors prevent an automated procedure from setting up an operator
                           option or performing any automated action, that option should be disabled or that
                           action not performed.
                     f) Automated procedures should not be considered acknowledged until all the
                           critical errors in the set of acknowledgement information characters have been
                           received correctly or corrected by repeat reception.
                     g) Information that is normally displayed that contains errors should be displayed to
                           the full extent possible; for example, digits in the MMSI or position information
                           that are received correctly should be displayed in their correct positions and those
                           that are not should be indicated by some special error symbol.
                8) Transmission of DSC messages
                     Transmission of DSC messages should use a prioritized wait scheme. If the channel is
                     not free, and the DSC message is a distress alert, the alert should be transmitted as
                     soon as the channel becomes free or after 10 s on MF or HF or 1 s on VHF, which
                     ever occurs first. For all other DSC messages,the automated procedure should wait
                     for the channel to become free and then delay transmission of the DSC message for a
                     specified wait time. Distress DSC messages (except for alerts), urgency,safety,
Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                      Page:    24 of 28                 Issued:   2019-03-14

                        routine and test DSC messages should wait one, two, three, and four “fixed” units of
                        time plus a random addition described below, respectively, before attempting to
                        transmit. Transmission occurs if and only if the channel is still free after this wait time
                        has elapsed, otherwise the process is repeated. The fixed “unit” of time should be 100
                        ms on MF and HF and 50 ms on VHF. The randomly generated component should be
                        some positive integer with resolution in milliseconds
                        between zero and the fixed interval. On MF/HF the channel is considered free if the
                        receiver hardware or DSP software is unable to recognize the DSC tones.
                   9)   Automated termination
                        a) Automated procedures should have an automated termination timer whose
                             factory default values can be changed by the operator. It should be possible to
                             disable this timer. Unacknowledged sending distress automated procedures
                             should not have a termination timer, however after acknowledgement a
                             termination timer is optional.
                        b) At least 10 s prior to automatic termination, a warning with a discrete aural alarm
                             should be displayed giving the operator the opportunity to stop the termination.

TEST RESULTS: Complies

              2.Tasks specific to certain automated procedures
                1) Tasks of automated procedures initiated by receiving non-distress DSC messages
                     a) Display of elapsed time
                            The elapsed time since receiving the initiating DSC message should be displayed
                            or after any requested acknowledgment has been sent, the elapsed time since
                            sending the acknowledgement should be displayed. Sending repeat
                            acknowledgments should not affect the time display.
                     b) Handling acknowledgments
                         i.      If the equipment has been set up to automatically acknowledge individually
                                    addressed polling, position request, or test DSC messages, no alarm should
                                    sound and the automated procedure should self-terminate.
                        ii.      All individually addressed DSC messages with subsequent communications
                                    should be automatically acknowledged as a default. In this case the alarm
                                    should sound after the acknowledgement is sent.
                       iii.      Acknowledgement options should only be made available to the operator
                                    when the received DSC message requests an acknowledgement.
                       iv.       When acknowledgments are requested the automated procedure should
                                    provide the operator with up to three possible acknowledgement options
                                    based upon the received DSC message as follows:
                                 i.      Able to comply: This option should be provided if the frequencies and
                                         mode of subsequent communication are provided by the received DSC
                                         message and the equipment is capable of handling the requested
                                         communications, or if the received DSC message is a polling,
                                         position request, or test that has not been automatically acknowledged.
                                ii.      Able to comply with a mode or frequency change: This option should be
                                         provided if the received DSC message requests subsequent
                                         communications.
                               iii.      Unable to comply: This option should be provided if the received DSC
                                         message contains subsequent communications or is a position request.
                                         The sending of this acknowledgement indicates a refusal and should
                                         terminate the automated procedure.
                        v.       The automated procedure should automatically compose the
                                    acknowledgement messages based upon the received DSC message as
                                    shown in Fig. 2 and Fig. 3.
                                 i.      “Able to comply” acknowledgments should be composed in entirety by
                                         the automated procedure.
                                ii.      “Able to comply with a mode or frequency change” acknowledgements
                                         should only require the entry/selection of a new mode and/or frequency.
                               iii.      “Unable to comply” acknowledgments to DSC messages containing
                                         subsequent communications should only require the entry/selection of
                                         one of the ten telecommand 2 “reason” symbols specified in Table 3.
                               iv.       “Unable to comply” acknowledgments to position requests if
                                         implemented should only
                                         require a single action by the operator to send. The procedure should
                                         automatically place the “no
                                         information symbol” in the position and time messages of the
Shenzhen Huatongwei International Inspection Co., Ltd.                    Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                     Page:   25 of 28                Issued:   2019-03-14

                                       acknowledgement.
                          vi.   The operator should be able to resend a duplicate of the first
                                  acknowledgement in automated procedures that have subsequent
                                  communications.
                2) Tasks of automated procedures initiated by sending a non-distress DSC message
                     a) Display of elapsed time
                            The elapsed time since sending the initial DSC message should be displayed or
                            after the automated procedure has received a requested acknowledgment, the
                            elapsed time since acknowledgement should be displayed. Receiving repeat
                            acknowledgments should not affect the time display.
                     b) Resending the initial DSC message
                         i.     If no acknowledgement is requested the option to resend the initial DSC
                                  message should remain available until the procedure is terminated.
                        ii.     If an acknowledgement is requested the option to resend the initial DSC
                                  message should remain available until the acknowledgment has been
                                  received.
                     c) Handling the reception of a delayed acknowledgement
                            If an acknowledgement appropriate to this automated procedure is received but
                            the operator has terminated the automated procedure prematurely, the
                            appropriate automated procedure should be reconstructed based on the
                            acknowledgement and the operator informed of the situation.
                3) Tasks of automated procedures initiated by receiving a distress DSC message or
                     sending a distress relay on behalf of someone else.
                     a) Display of elapsed time
                            The elapsed time since receiving the initial DSC message should be displayed or
                            after the automated procedure has been acknowledged, the elapsed time since
                            acknowledgement should be displayed. Receiving repeat acknowledgments
                            should not affect the time display.
                     b) Determining operator options
                         i.     On HF the operator should have the option to set the general receiver and
                                  transmitter to any one of the six distress frequencies of subsequent
                                  communication.
                        ii.     The option to send a relay should always be available until the automated
                                  procedure is terminated.
                       iii.     Distress alert acknowledgments and relay acknowledgement options
                                  1) These options should not be made available until a DSC message has
                                       been received that can respond to the acknowledgement.
                                  2) These options should be available immediately after reception of the
                                       appropriate DSC messages and not wait until certain conditions for their
                                       use, such as time limits, are fulfilled.
                                  3) Once these options are available, they should remain available until the
                                       automated procedure is terminated.
                     c) DSC message composition
                         i.     The automated procedure should automatically compose relays, distress alert
                                  acknowledgments and relay acknowledgments based upon the received
                                  DSC messages.
                                  1) The distress information should be taken from the distress DSC
                                       message which has the latest UTC time stamp.
                                  2) Distress alert acknowledgements and relay acknowledgements should
                                       require no data entry by the operator except on HF where the frequency
                                       of the DSC message may be selected.
                        ii.     Relays should only allow the entry of the addressing mode (format) and
                                  destination address and on HF, the mode of subsequent communication and
                                  the frequency of the DSC message.
                       iii.     On HF the automated procedure should indicate those frequencies on which
                                  DSC messages pertinent to the automated procedure have been received as
                                  the preferred choices,however the operator should be allowed to choose any
                                  of the six distress frequencies.
                     d) Tuning of the radio after acknowledgment on HF
                            The automated tuning should cease upon reception or sending of a distress alert
                            acknowledgement or a distress relay acknowledgment addressed to multiple
                            stations. However, the operator should be provided with sufficient information to
                            manually tune to the working frequencies of the most
                            recently received DSC message.
                     e) Handling individually addressed relays
Shenzhen Huatongwei International Inspection Co., Ltd.                 Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                        Page:    26 of 28                 Issued:   2019-03-14

                             i.       The sending or receiving of individually addressed relays should initiate their
                                       own automated procedure separate from the automated procedure that may
                                       be handling distress DSC messages concerning the same distress event.
                             ii.      The option to send a distress alert acknowledgement should never be
                                       available during this automated procedure.
                        f)       Handling DSC messages with critical errors
                                 If the subsequent communication parameter of the distress information is
                                 received in error,radiotelephone should be assumed and an indication that the
                                 parameter was received in error should be made known to the operator.
                        g)       Handling the self-addressed distress alert acknowledgement
                                 If the MMSI of the sender of a distress alert acknowledgement is the same as the
                                 MMSI of the vessel in distress, the automated procedure should recognize the
                                 message as an attempt to cancel the distress alert and inform the operator
                                 accordingly.
                        h)       Extended DSC sentences
                        i)       The automated procedure should be able to successfully receive and decode
                                 single frequency alert attempts that have extended sentence information at the
                                 end of some or all of the individual alerts.
                        j)       MF/HF only scanning for distress DSC messages
                                 The received distress automated procedure should scan all six distress DSC
                                 channels if not already doing so.

TEST RESULTS: Complies

                   4)Tasks of automated procedures initiated by sending a distress alert attempt
                     a) Display of elapsed time
                         i.      The time remaining to the sending of the next distress alert attempt should be
                                   displayed prior to acknowledgment by DSC.
                        ii.      The elapsed time since acknowledgement should be displayed after
                                   acknowledgment by DSC. Receiving repeat acknowledgments should not
                                   affect the time display.
                     b) Resending of the distress alert attempt
                         i.      The unacknowledged distress alert attempt should be automatically resent
                                   after a 3.5 to 4.5 min wait.
                        ii.      The automatic resending of the distress alert attempt should automatically
                                   terminate after acknowledgement by DSC.
                       iii.      Resent distress alert attempts should contain updated position and time of
                                   position information.
                     c) Determining operator options
                         i.      The option to manually resend the distress alert attempt at any time should
                                   remain available until the distress alert has been acknowledged by DSC.
                        ii.      On HF the operator should have the option to change the frequencies of the
                                   distress alert attempt and the option to select between the single frequency
                                   or multifrequency method.
                       iii.      The option to pause the countdown to the next distress alert attempt should
                                   be available prior to acknowledgement by DSC.
                       iv.       The option to cancel the distress alert should be available prior to
                                   acknowledgement by DSC.
                        v.       The option to terminate the procedure should only be available after
                                   acknowledgment by DSC.
                     d) The distress alert cancel procedure
                            The cancel procedure consists of the cancel operation on all bands utilized by the
                            distress alert attempts (on VHF and MF there is only one cancel operation
                            whereas on MF/HF there may be up to six). The cancel operation consists of a
                            DSC cancel message (a self-addressed distress alert acknowledgement)
                            followed by a voice cancel on the corresponding frequency of subsequent
                            communication. The phrase “voice cancel” refers to the part of the cancel done
                            over the subsequent communication frequencies whether it is by radiotelephony
                            or on MF and MF/HF by data.
                         i.      Upon selection of the cancel option the sending distress automated procedure
                                   should provide an explanation of the cancel procedure to the operator and
                                   provide the option to either continue or return and not do the cancel.
                        ii.      If the operator selects to proceed with the cancel procedure the sending
                                   distress automated procedure should pause the countdown to the next
                                   automated sending of the distress alert attempt and wait (if necessary) until
Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                      Page:    27 of 28                  Issued:   2019-03-14

                                     any alert within an attempt is transmitted to completion before allowing the
                                     operator to initiate the first cancel operation.
                           iii.    The operator options during the cancel procedure should be to terminate the
                                     cancel procedure and to start the cancel operation.
                          iv.      If the cancel procedure is terminated before the first cancel operation is
                                     started, the sending distress automated procedure should resume from
                                     where it left off. However, once the cancel operation is started, the option to
                                     terminate the cancel procedure should not be available
                                     until the cancel procedure is completed.
                            v.     The status of the cancel procedure should be displayed.
                          vi.      The operator should be provided with the appropriate text for the voice cancel
                                     at the time of the voice cancel.
                          vii.     The cancel operation should be able to be repeated on any band but a
                                     warning should be provided that the cancel has already been done on this
                                     band.
                         viii.     Special considerations for MF/HF
                                     1) The status of each of the bands should be displayed;
                                     2) Once one band is cancelled the option to end the cancel procedure
                                           should not be available until ALL utilized bands are cancelled;
                                     3) When the cancel procedure is completed, the sending distress
                                           automated procedure should be considered acknowledged and the fact
                                           that a cancel was performed should be displayed.
                        e) MF/HF only scanning for distress alert acknowledgements
                                The sending distress automated procedure should scan all six distress DSC
                                channels if not already doing so.

TEST RESULTS: Complies

                   5)   Radiotelephone communications automated procedure
                        The equipment should also be provided with a communications function for
                        radiotelephony that is compatible with the DSC automated procedures described in
                        this Annex. This automated procedure should have:
                        a) the ability to switch between being active or being on hold at the discretion of the
                             operator,
                        b) the ability to be terminated at the discretion of the operator,
                        c) the ability to select the channels for the communications, and

TEST RESULTS: Complies

                   6)   Other non-DSC automated procedures
                        Any other non-DSC functionality that is included in the equipment should:
                        a) be able to be activated or placed on hold at the discretion of the operator,
                        b) never control the watch receiver such that DSC automated procedures, either
                            active or on hold, are unable to receive DSC messages on the watch receiver,
                        c) be able to be terminated by the operator.

TEST RESULTS: Complies

              3.Tasks concerning multiple automated procedures
                1) Number of simultaneous automated procedures
                     Facilities should be provided to handle a minimum of seven simultaneous automated
                     procedures including a reserve of one. The initiation of the reserve automated
                     procedure should:
                     a) warn the operator that the equipment cannot handle another automated
                          procedure and that one automated procedure should be terminated,
                     b)    prevent the operator from initiating any new automated procedures except for the
                          sending of a distress alert and,
                     c) warn the operator that the reception of an additional DSC message that would
                          initiate an automated procedure if the equipment were in standby will result in the
                          automatic and immediate termination of an inactive automated procedure where,
                     d) the automatic and immediate termination should be based upon age and priority.
                2) Sending distress automated procedure
                     When initiating a sending distress automated procedure, automatic immediate
                     termination of all other automated procedures (if any) is encouraged but not required.
                3) Operator options
Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No :   CHTEW19030080                    Page:     28 of 28              Issued:   2019-03-14

                        a)   The operator should be able to freely navigate between the automated
                             procedures except when engaged in an unacknowledged sending distress
                             automated procedure.
                        b) When the operator makes any one of the automated procedures on hold active,
                             the automated procedure that was active (if any) should automatically go on hold.
                   4)   Unacknowledged poll, test, or position request automated procedures received on
                        hold
                        If any of these automated procedures is set to automatically acknowledge, it should
                        automatically acknowledge and self terminate as soon as all remaining automated
                        procedures are on hold.

TEST RESULTS: Complies

              4.   Warnings
                   Warnings should be provided when the operator attempts to do the following:
                   1) send a relay before three minutes have elapsed since the automated procedure
                      started,
                   2) send a non-individually addressed relay,
                   3) send a distress alert acknowledgement (requires coast station permission),
                   4) send an all stations (116 format) distress relay acknowledgement (should be sent by
                      coast station only),
                   5) send an acknowledgement to a DSC message containing no distress information that
                      is not individually addressed,
                   6) cancel a distress alert,
                   7) send any DSC message after the objective of the automated procedure has been
                      obtained,
                   8) terminate the automated procedure before the objective has been reached,
                   9) terminate the automated procedure if engaged in subsequent communications.

TEST RESULTS: Complies




                                    -----------------End of Report----------------




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)