Test Report 2

FCC ID: K6630443X3D

Test Report

Download: PDF
FCCID_2127079

   RFT
                                                                                   Issue Date: 09 Nov. 2013
                                                                                   Report No.: ERY1311P09R1
                                                                                   Model: GX2200




                                         TEST REPORT
                                                                   For

                         Marine Transceiver/MATRIX AIS/GPS
                                                          In conformity with

                                    FCC CFR 47 Part80 Subpart E
                                   RSS-282 Issue5 (RSS-Gen Issue 3)

         Model                    : GX2200

         FCC ID                   : K6630443X3D
         IC                       : 511B-30443X3D

         Test Item                : Marine Transceiver/MATRIX AIS/GPS

         Report No. : ERY1311P09R1

         Issue Date               : 09 Nov. 2013


           Prepared for
                                YAESU MUSEN CO., LTD.
                                  Tennozu Parkside Building 2-5-8 Higashi-shinagawa,
                                  Shinagawa-ku, Tokyo 140-0002 Japan

           Prepared by
                                RF Technologies Ltd.
                                  472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
                                  Telephone: +81+(0)45- 534-0645
                                  FAX: +81+(0)45- 534-0646




         This report shall not be reproduced, except in full, without the written permission of
         RF Technologies Ltd. The test results in this report apply only to the sample tested.
         RF Technologies Ltd. is managed to ISO17025 and has the necessary knowledge and test facilities for
         testing according to the referenced standards.


RF Technologies Ltd.                                                                             Page 1 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


    RFT
                                                                                                                                     Issue Date: 09 Nov. 2013
                                                                                                                                     Report No.: ERY1311P09R1
                                                                                                                                     Model: GX2200


Table of contents
1      General information ...................................................................................................................... 3
    1.1     Product description ................................................................................................................................................ 3
    1.2     Test(s) performed/ Summary of test result ............................................................................................................ 3
    1.3     Test facility ............................................................................................................................................................ 4
    1.4     Measurement uncertainty ....................................................................................................................................... 4
    1.5     Summary of test results.......................................................................................................................................... 5
    1.6     Setup of equipment under test (EUT) .................................................................................................................... 5
       1.6.1     Test configuration of EUT ............................................................................................................................. 5
       1.6.2     Operating condition: ...................................................................................................................................... 5
       1.6.3     Setup diagram of tested system...................................................................................................................... 6
    1.7     Equipment modifications ....................................................................................................................................... 6
    1.8     Deviation from the standard .................................................................................................................................. 6
2      Test procedure and test data ........................................................................................................ 7
    2.1        Radiated spurious emissions (Transmitter test) ..................................................................................................... 7
    2.2        Radiated emissions (Receiver test) ...................................................................................................................... 11
3      Test setup photographs ............................................................................................................... 14
    3.1        Radiated emissions .............................................................................................................................................. 14
4      List of utilized test equipment / calibration .............................................................................. 15




History
             Report No.                       Date                                                         Revisions                                                  Issued By
           ERY1311P09R1                   09 Nov. 2013                Initial Issue                                                                                     T.Kato




RF Technologies Ltd.                                                                                                                                         Page 2 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


                                                                                               Issue Date: 09 Nov. 2013
                                                                                               Report No.: ERY131 IPOOR1
                                                                                               Model: GX2200


 1     General information

1.1 Product description
        Test item                                   : Marine Transceiver/MATRIX AIS/GPS
        Manufacturer                                : YAESU MUSEN CO., LTD.
        Address                                     :43 Utsuroda, Morijuku, Sukagawa—shi, Fukushima—ken 962—0001 Japan
        Model                                       :   GX2200
        FCC ID                                      :   K6630443X3D
        1C                                          :   511B—30443X3D
        Serial number                               :   L41B000001
        Operating frequency                         :   156.025 — 163.275 MHz
        Output power                                :25 W (High) / 1 W (Low) nominal
        Emission designator                         : 16K0G3E (Voice), 16K0G2B (DSC)
        Software version                            :   N/A
        Hardware version                            :   N/A
        Highest operating frequency                 :   9.8304 MHz
        Receipt date of EUT                         :   06 Nov. 2013
        Nominal power source voltages               :   13.8 Vde



1.2     Test(s) performed/ Summary of test result

        Test specification(s)                       :   FCC CFR 47. Part 80 subpart E
                                                    :   RSS—182 Issue 5 (RSS—Gen Issue 3)
        Test method(s)                              :   TIS—603—D (FCC Part 80)
                                                    :   ANSI C63.4: 2003 (RSS)
        Test(s) started                             :   09 Nov. 2013
        Test(s) completed                           : 09 Nov. 2013
        Purpose of test(s)                          : Certification / Class II permissive change

        Summary oftest result                       : Complied



       Note: The above judgment is only based on the measurement data andit does not include the measurement
             uncertainty. Accordingly, the statement below is applied to the test result.
             The EUT complies with the limit required in the standard in case that the margin is not less than the
             measurement uncertainty in the Laboratory.
             Compliance of the EUT is more probable than non—complianceis case that the margin is less than the
             measurement uncertainty in the Laboratory.



Test engineer                            __ILa      T. Kato
                                                    EMC testing Department


Reviewer                                                    y          ~            .

                                                    K. Ohnishi
                                                    Manager
                                                    EMC testing Department




RF Technologies Ltd.                                                                                           Page 3 of 15
472, Nippa—cho, Kohoku—ku, Yokohama, 223—0057, Japan
Telephone: +81+(0)45— 534—0645, FAX: +8 1+(0)45— 534—0646, Web: http://www.rft.jp


   RFT
                                                                                      Issue Date: 09 Nov. 2013
                                                                                      Report No.: ERY1311P09R1
                                                                                      Model: GX2200


1.3 Test facility
        The Federal Communications Commission has reviewed the technical characteristics of the test facilities at
        RF Technologies Ltd., located in 472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan, and
        has found these test facilities to be in compliance with the requirements of 47 CFR Part 15, section 2.948,
        per October 1, 2010.
        The description of the test facilities has been filed under registration number 319924 at the Office of the
        Federal Communications Commission. The facility has been added to the list of laboratories performing
        these test services for the public on a fee basis.
        The list of all public test facilities is available on the Internet at http://www.fcc.gov.

        Registered by Industry Canada (IC): The registered facility number is as follows;
        Test site No. 1 (Semi-Anechoic chamber 3m): 6974A-1

        Accredited by National Voluntary Laboratory Accreditation Program (NVLAP) for the emission tests
        stated in the scope of the certificate under Certificate Number 200780-0

        This report must not be used by the client to claim product certification, approval, or endorsement by
        NVLAP, NIST, or any agency of the Federal Government.




1.4 Measurement uncertainty
        The treatment of uncertainty is based on the general matters on the definition of uncertainty in “Guide to the
        expression of uncertainty in measurement (GUM)” published by ISO. The Lab’s uncertainty is determined
        by referring UKAS Publication LAB34: 2002 “The Expression of Uncertainty in EMC Testing” and
        CISPR16-4-2: 2011 “Uncertainty in EMC Measurements”.
        The uncertainty of the measurement result in the level of confidence of approximately 95% (k=2) is as
        follows;

        Conducted emission: ± 3.4 dB (10 kHz - 30 MHz)
        Radiated emission (9 kHz - 30 MHz): ± 3.3 dB
        Radiated emission (30 MHz - 200 MHz): ± 5.0 dB
        Radiated emission (200 MHz - 1000 MHz): ± 6.2 dB
        Radiated spurious emission (30 MHz - 1000 MHz): ± 1.8 dB
        Radiated spurious emission (1 GHz – 18 GHz): ± 2.8 dB




RF Technologies Ltd.                                                                                  Page 4 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                                  Issue Date: 09 Nov. 2013
                                                                                                  Report No.: ERY1311P09R1
                                                                                                  Model: GX2200


1.5 Summary of test results
                                                                                   Section                              Section in
                                  Requirement                                                           Result
                                                                                 in Standard                            this report
         Tx Radiated spurious emissions (30 to 1700 MHz) *                     FCC 80.211(f)(3)        Complied             2.1
                                                                              RSS-182 Sec. 7.11
         Rx Radiated emissions (30 – 1000 MHz) **                                                      Complied            2.2
                                                                              RSS-Gen Sec. 4.10

          * Maximum frequency of transmitter is 163.275 MHz
          ** Maximum internal operating frequency is 9.8304 MHz.


1.6 Setup of equipment under test (EUT)
1.6.1 Test configuration of EUT
Equipment(s) under test
      No.              Item                              Manufacture                      Model No.                 Serial No.
       A    Marine Transceiver                     YAESU MUSEN CO., LTD.               GX2200                    L41B000001
             /MATRIX AIS/GPS
       B    Microphone                             -                                   -                         -
          *Microphone is a part of the EUT.


Support Equipment(s)
       No.                     Item                            Manufacture                 Model No.         Serial        FCC ID
                                                                                                              No.
           C     Remote Station Microphone             Vertex Standard Co., Ltd.       CMP30               0J150202        -
                                                                                                                           -

Connected cable(s)
      No.                    Item                       Identification                      Cable         Ferrite          Length
                                                         (Manu.etc.)                       Shielded        Core             [m]
           1     Mic cable of EUT                YAESU MUSEN CO., LTD.                       Yes            No              0.5
           2     DC cable                        YAESU MUSEN CO., LTD.                       No             No              1.3
           3     23-Foot Routing cable           YAESU MUSEN CO., LTD.                       Yes           Yes              7.0
           4     Mic. cable of CMP30             YAESU MUSEN CO., LTD.                       Yes            No              0.5


1.6.2    Operating condition:

        Tx Mode:                The EUT transmit Tx power in 16 ch.
                                (Tx power level are two mode. ( Hi:25W, Low:1W)
        Rx Mode:                The EUT is in receiving mode at 16/70 ch.




RF Technologies Ltd.                                                                                                 Page 5 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                   Issue Date: 09 Nov. 2013
                                                                                   Report No.: ERY1311P09R1
                                                                                   Model: GX2200

1.6.3 Setup diagram of tested system


                                                     A:
                                                  Marine
                                                Transceiver
                                    1              (EUT)                       3
                                                                                    4
                                                   2

                             B:                                                         C:
                        Microphone                                                   Remote
                           (EUT)                                                   Station Mic.

                                                  DC 13.8V



1.7 Equipment modifications
        No modifications have been made to the equipment in order to achieve compliance with the applicable
        standards described in clause 1.2.


1.8 Deviation from the standard
        No deviations from the standards described in clause 1.2.




RF Technologies Ltd.                                                                              Page 6 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                          Issue Date: 09 Nov. 2013
                                                                                          Report No.: ERY1311P09R1
                                                                                          Model: GX2200


2 Test procedure and test data
2.1 Radiated spurious emissions (Transmitter test)
Test setup
       Test setup was implemented according to the method of ANSI C63.4: 2003 clause 6 “General requirements
       for EUT equipment arrangements and operation”, clause 8.2 and Annex H.3 “Radiated emission
       measurements setup”.


Test procedure
      Measurement procedures were implemented according to the method of TIA-603-C clauses 2.2.12.2.

        a) Antenna terminal of the EUT is terminated with a nonradiating load.
        b) Adjust the spectrum analyzer as below.
                  1) RBW = 10 kHz (below 1 GHz), 1 MHz (above 1 GHz)
                  2) VBW = 300 kHz (below 1 GHz), 3 MHz (above 1 GHz)
                  3) Sweep speed slow enough to maintain measurement
                  4) Detector mode : Peak
        c) Place the EUT on the turntable. The EUT set Tx ON in max power level
        d) For each spurious frequency that was found, the test antenna is raised and lowered from 1 to 4 m to obtain
            a maximum level on the spectrum alnalyzer. Then the turntable should be rotated 360 deg to determine
            the maximum reading.
        e) Repeat step d) for each spurious frequency with the test antenna polarized vert/hori.
        f) The EUT was replaced with substitution antenna and signal generator.
        g) Feed the substitution antenna at the transmitter end with signal generator connected to the antenna by
            means od a nonradiating cable. With the antennas at both ends horizontally polarized, and with the signal
            generator tuned to a paticular spurious frequency, raise and lower the test antenna to obtain a maximum
            reading at the spestrum analyzer. Adjust the level of the signal generator output until the previously
            recorded maximum reading for this set of conditions is obtained. This should be done carefully repeating
            the adjustment of the test antenna and generator output.
        h) Repeat step g) with both antennas vertically polarized for each spurious frequency.
        i) Calculate power in dBm erp as below.
                  Spurious emission level = Antenna input level [dBm] + Substitution antenna gain [dBd]


Applicable rule and limitation
      Part 80.211 (f) (3) Radiated emission limits

        Limit Level = Po [dBm] – (43 + 10 log (Po [W])) = - 13 [dBm erp]


Test results - Complied with requirement


Test equipment used (refer to List of utilized test equipment)

            AC01           CL11            TR06            PR15           BI05     LA07      CL30
            CL31           PR12            DR01




RF Technologies Ltd.                                                                                    Page 7 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                             Issue Date: 09 Nov. 2013
                                                                                             Report No.: ERY1311P09R1
                                                                                             Model: GX2200

Test Data

        Operating mode: Tx mode (16ch / 25W)
        Measurement distance: 3 m

        [Spurious emission level]
                         Frequency                Result          Limit            Margin
                No.                                                                         Ant.
                            [MHz]               [dBµV/m]        [dBµV/m]            [dB]
                  1          313.6                -35.9           -13.0             22.9    Hori.
                  2          470.4                -39.6           -13.0             26.6    Hori.
                  3          627.2                -44.1           -13.0             31.1    Hori.
                  4          784.0                -38.1           -13.0             25.1    Hori.
                  5          940.8                -39.6           -13.0             26.6    Hori.
                  6         1097.6                -51.2           -13.0             38.2    Hori.
                  7         1254.4                -51.7           -13.0             38.7    Hori.
                  8         1411.2                -45.1           -13.0             32.1    Hori.
                  9         1568.0                -52.0           -13.0             39.0    Hori.
                 10          313.6                -48.2           -13.0             35.2    Vert.
                 11          470.4                -45.6           -13.0             32.6    Vert.
                 12          627.2                -38.2           -13.0             25.2    Vert.
                 13          784.0                -38.7           -13.0             25.7    Vert.
                 14          940.8                -42.9           -13.0             29.9    Vert.
                 15         1097.6                -47.0           -13.0             34.0    Vert.
                 16         1254.4                -47.1           -13.0             34.1    Vert.
                 17         1411.2                -43.6           -13.0             30.6    Vert.
                 18         1568.0                -46.0           -13.0             33.0    Vert.


          [Chart]




          Note: 156.8 MHz is Tx carrier frequency.




RF Technologies Ltd.                                                                                       Page 8 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                             Issue Date: 09 Nov. 2013
                                                                                             Report No.: ERY1311P09R1
                                                                                             Model: GX2200




        Operating mode: Tx mode (16ch / 1W)
        Measurement distance: 3 m

        [Spurious emission level]
                         Frequency                Result          Limit            Margin
                No.                                                                         Ant.
                            [MHz]               [dBµV/m]        [dBµV/m]            [dB]
                  1          313.6                -41.3           -13.0             28.3    Hori.
                  2          470.4                -40.8           -13.0             27.8    Hori.
                  3          627.2                -57.1           -13.0             44.1    Hori.
                  4          784.0                -46.7           -13.0             33.7    Hori.
                  5          940.8                -52.4           -13.0             39.4    Hori.
                  6         1097.6                -59.2           -13.0             46.2    Hori.
                  7         1254.4                -55.5           -13.0             42.5    Hori.
                  8         1411.2                -49.0           -13.0             36.0    Hori.
                  9         1568.0                -56.1           -13.0             43.1    Hori.
                 10          313.6                -51.5           -13.0             38.5    Vert.
                 11          470.4                -48.3           -13.0             35.3    Vert.
                 12          627.2                -57.2           -13.0             44.2    Vert.
                 13          784.0                -46.4           -13.0             33.4    Vert.
                 14          940.8                -53.4           -13.0             40.4    Vert.
                 15         1097.6                -58.8           -13.0             45.8    Vert.
                 16         1254.4                -51.5           -13.0             38.5    Vert.
                 17         1411.2                -47.0           -13.0             34.0    Vert.
                 18         1568.0                -54.5           -13.0             41.5    Vert.




RF Technologies Ltd.                                                                                       Page 9 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                              Issue Date: 09 Nov. 2013
                                                                                              Report No.: ERY1311P09R1
                                                                                              Model: GX2200



          [Chart]




          Note: 156.8 MHz is Tx carrier frequency.




        Tested Date:        09 Nov. 2013                    Temperature:           20 degC
        Humidity:           41 %                            Atmos. Press:          1029 hPa




RF Technologies Ltd.                                                                                        Page 10 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                          Issue Date: 09 Nov. 2013
                                                                                          Report No.: ERY1311P09R1
                                                                                          Model: GX2200



2.2 Radiated emissions (Receiver test)
Test setup
       Test setup was implemented according to the method of ANSI C63.4: 2003 clause 6 “General requirements
       for EUT equipment arrangements and operation”, clause 8.2 and Annex H.3 “Radiated emission
       measurements setup”.


                                                                                       Semi anechoic room



             1-4m
                                                Rx Antenna

                                                                                                EUT
                                                                               3.0 m

                                                                                                               0.8 m




                Pre-amplifier                  Test
                                             Receiver



Test procedure
      Measurement procedures were implemented according to the method of ANSI C63.4: 2003 clauses 8.2.
      The EUT is place on a non-conducted table which is 0.8 m height from a ground plane and the measurement
      antenna to EUT distance is 3 meters. The turn table is rotated for 360 degrees to determine the maximum
      emission level.
      The antenna height scanned between 1 m and 4 m, and the antenna rotated to repeat the measurements for
      both the horizontal and vertical antenna polarizations.
      The spectrum analyzer and receiver are set to the followings;
                RBW=100 kHz, VBW= 300 kHz
                Final measurement is carried out with a receiver RBW of 120 kHz (QP)


Applicable rule and limitation
      RSS-Gen clauses 6.1: Radiated emission limits
               Frequency               Field Strength             Measurement      Field Strength
                  [MHz]                    [µV/m]                 Distance [m]       [dBµV/m]
                 30 – 88                     100                        3               40.0
                 88 –216                     150                        3               43.5
               216 – 960                     200                        3               46.0
               Above 960                     500                        3               53.9
      In the emission table above, the tighter limit applies at the band edges.
      The emission limits shown in the above table are based on measurements employing a quasi-peak detector.




RF Technologies Ltd.                                                                                    Page 11 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                             Issue Date: 09 Nov. 2013
                                                                                             Report No.: ERY1311P09R1
                                                                                             Model: GX2200

Test results - Complied with requirement


Test equipment used (refer to List of utilized test equipment)

            AC01           CL11            TR06            PR15           BI05        LA07


Test Data

        Operating mode: Rx mode 16ch
        Measurement distance: 3 m

        [Emission level]
                  Frequency           Reading        Factor     Loss       Gain      Result   Limit    Margin
          No.                                                                                                      Ant.
                     [MHz]            [dBµV]        [dB/m]      [dB]       [dB]    [dBµV/m] [dBµV/m]    [dB]
           1        135.100             43.3          14.3       8.4       30.1       35.9     43.5      7.6      Hori.
           2        200.875             38.7          11.6       9.0       30.0       29.3     43.5     14,2      Hori.
           3        229.625             42.0          11.7       9.4       29.9       33.2     46.0     12.8      Hori.
           4        270.200             44.6          12.5       9.8       29.9       37.0     46.0      9.0      Hori.
           5        405.300             40.0          15.8      11.1       29.8       37.1     46.0      8.9      Hori.
           6        459.250             34.7          16.9      11.5       29.7       33.4     46.0     12.6      Hori.
           7        540.400             39.4          18.2      12.0       29.5       40.2     46.0      5.9      Hori.
           8        810.600             35.7          20.9      13.1       30.4       39.3     46.0      6.7      Hori.
           9        135.100             48.2          14.3       8.4       30.1       40.8     43.5      2.7      Vert.
          10        200.875             40.4          11.6       9.0       30.0       31.0     43.5     12.5      Vert.
          11        540.392             39.2          18.2      12.0       29.5       39.9     46.0      6.1      Vert.

        [Calculation sample]
                       Correction Factor [dB/m] = FACTOR [dB/m] + LOSS [dB] – GAIN [dB]

                       RESULT [dBµV/m] = READING [dBµV] + Correction Factor [dB/m]

        [Chart]




RF Technologies Ltd.                                                                                       Page 12 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                               Issue Date: 09 Nov. 2013
                                                                                               Report No.: ERY1311P09R1
                                                                                               Model: GX2200



        Operating mode: Rx mode 70ch
        Measurement distance: 3 m

        [Emission level]
                  Frequency           Reading        Factor     Loss       Gain        Result   Limit    Margin
          No.                                                                                                        Ant.
                     [MHz]            [dBµV]        [dB/m]      [dB]       [dB]      [dBµV/m] [dBµV/m]    [dB]
           1        134.825             43.4          14.2       8.4       30.1         35.9     43.5      7.6      Hori.
           2        229.625             42.1          11.7       9.4       29.9         33.3     46.0     12.7      Hori.
           3        269.650             44.7          12.5       9.8       29.9         37.1     46.0      8.9      Hori.
           4        404.475             41.1          15.8      11.1       29.8         38.2     46.0      7.8      Hori.
           5        539.300             40.1           1.2      12.0       29.5         40.8     46.0      5.2      Hori.
           6        674.124             33.7          19.5      12.6       29.8         36.0     46.0     10.0      Hori.
           7        808.950             35.4          20.9      13.1       30.4         39.0     46.0      7.0      Hori.
           8        134.825             48.1          14.2       8.4       30.1         40.6     43.5      2.9      Vert.
           9        200.874             40.2          11.6       9.0       30.0         30.8     43.5     12.7      Vert.
          10        539.300             39.7          18.2      12.0       29.5         40.4     46.0      5.6      Vert.

        [Calculation sample]
                       Correction Factor [dB/m] = FACTOR [dB/m] + LOSS [dB] – GAIN [dB]

                       RESULT [dBµV/m] = READING [dBµV] + Correction Factor [dB/m]

        [Chart]




        Tested Date:        09 Oct. 2013                    Temperature:           20 degC
        Humidity:           41 %                            Atmos. Press:          1029 hPa




RF Technologies Ltd.                                                                                         Page 13 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                   Issue Date: 09 Nov. 2013
                                                                                   Report No.: ERY1311P09R1
                                                                                   Model: GX2200


3 Test setup photographs
3.1      Radiated emissions




RF Technologies Ltd.                                                                             Page 14 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp


   RFT
                                                                                                    Issue Date: 09 Nov. 2013
                                                                                                    Report No.: ERY1311P09R1
                                                                                                    Model: GX2200


4 List of utilized test equipment / calibration
    RFT           Kind of Equipment and                                                                 Calibration
                                                   Manufacturer           Model No.     Serial Number                   Calibrated until
   ID No.               Precision                                                                          Date

 AC01(EM) Anechoic Chamber (1st test room)               JSE               203397C            -          2013/4/20        2014/4/30

 AC01(EG)     Anechoic Chamber (1st test room)           JSE               203397C            -         2012/11/17       2013/11/30
                                                                           VHA9103
    BI05              Biconical Antenna          SCHWARZBECK                             91032894        2012/12/3       2013/12/31
                                                                          & BBA9106
   CL11             Antenna Cable for RE                RFT                   -               -         2013/10/22       2014/10/31

   CL30                RF Cable 5 m                   SUHNER            SUCOFLEX104PE     MY3599         2013/8/10        2014/8/31

   CL31                RF Cable 1 m                   Junkosha             MWX221        1303S118       2013/10/17       2014/10/31

   DH01              DRG Horn Antenna               A.H. Systems           SAS-571          785          2012/1/27        2014/1/31

   LA07             Logperiodic Antenna          SCHWARZBECK             VUSLP9111B         102          2012/12/3       2013/12/31

   PR12             Pre. Amplifier (1-26G)       Agilent Technologies       8449B       3008A02513       2013/1/15        2014/1/31

   PR15                 Pre. Amplifier                 Anritsu             MH648A       6201156141       2013/6/11        2014/6/30
                        Test Receiver
   TR06                                           Rohde & Schwarz           ESU26          100002        2013/9/10        2014/9/30
                      (F/W : 3.93 SP2)

        The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated
        in accordance with the manufacturer's recommendations for utilizing calibration equipment, which is
        traceable to recognized national standards.




RF Technologies Ltd.                                                                                                  Page 15 of 15
472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan
Telephone: +81+(0)45- 534-0645, FAX: +81+(0)45- 534-0646, Web: http://www.rft.jp



Document Created: 2019-11-17 21:40:11
Document Modified: 2019-11-17 21:40:11

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC