TEST REPORT

FCC ID: K6630073X20

Test Report

Download: PDF
FCCID_446256

TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com




                                           Test Report

                            Product Name: HX270S MARINE HT RADIO

                                       FCC ID: K6630073X20




                                             Applicant:

                               VERTEX STANDARD CO., LTD.
                              4-8-8 NAKAMEGURO, MEGURO-KU
                                    TOKYO 153-8644
                                         JAPAN




                               Date Receipt: MAY 24, 2004

                               Date Tested: JUNE 15, 2004




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                                   COVER SHEET


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com


                                    TABLE OF CONTENTS LIST


APPLICANT:      VERTEX STANDARD CO., LTD.

FCC ID:         K6630073X20


        TEST REPORT:


                PAGE 1............GENERAL INFORMATION & TECHNICAL DESCRIPTION
                PAGE 2............TECHNICAL DESCRIPTION CONTINUED
                                  RF POWER OUTPUT
                PAGE 3............TECHNICAL DATA
                PAGE 4............VOICE MODULATION CHARACTERISITICS
                                  AUDIO FREQUENCY RESPONSE
                PAGE 5............AUDIO LOW PASS FILTER
                PAGE 6............MODULATION LIMITING
                PAGE 7............OCCUPIED BANDWIDTH
                PAGE 8............OCCUPIED BANDWIDTH PLOT
                PAGE 9............SPURIOUS EMISSIONS AT ANTENNA TERMINALS
                PAGE 10...........METHOD OF MEASURING CONDUCTED SPURIOUS EMISS
                PAGE 11-12........FIELD STRENGTH OF SPURIOUS EMISSIONS
                PAGE 13...........METHOD OF MEASURING RADIATED SPURIOUS EMISSIONS
                PAGE 14...........FREQUENCY STABILITY
                PAGE 15...........LIST OF TEST EQUIPMENT


        EXHIBITS INCLUDING:

                REQUEST FOR CONFIDENTIALITY LETTER
                BLOCK DIAGRAM
                SCHEMATIC
                PARTS LIST
                USERS MANUAL
                LABEL SAMPLE & LOCATION
                EXTERNAL PHOTOGRAPHS
                INTERNAL PHOTOGRAPHS
                ALIGNMENT PROCEDURE
                OPERATIONAL DESCRIPTION
                TEST SET UP PHOTOGRAPHS




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           TABLE OF CONTENTS


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com

                                       GENERAL_INFORMATION

         2.1033(c)              VERTEX STANDARD CO., LTD. will sell the FCC ID:
                                K6630073X20 VHF Marine transmitter in quantity,
                                for use under FCC RULES PART 80.

         2.1033(c)              TECHNICAL_DESCRIPTION

                     (4)        Type of Emission: 16K0G3E/16K0F3E

                                        Bn   =   2M + 2DK
                                         M   =   3000
                                         D   =   4.6KHz (Peak Deviation)
                                         K   =   1
                                        Bn   =   2(3.0K) + 2(4.6K)(1) = 6.0K + 9.2 = 15.2K

        80.205 (a)              ALLOWED AUTHORIZED BANDWIDTH = 20.00KHz.


         2.1033(c)(6)           Frequency Range:             156.025 – 157.425 MHz

         2.1033(c)(7)           Power Range and Controls: There is a user Power
                                switch for High/Low Power. Maximum Output Power
                                Rating: High PWR Watts, PWR1 Watt into a 50 ohm
                                resistive load.

         2.1033(c)(8)           DC Voltages and Current into Final Amplifier:

                                POWER INPUT
                                      FINAL AMPLIFIER ONLY
                                      High                          Low
                                        Vce = 7.2 Volts               Vce = 7.2 Volts
                                        Ice = 1.53 A.                 Ice = 0.61 A.

                                           Pin = 11.02 Watts          Pin = 4.29 Watts

                                Function of each electron tube or semiconductor
                                device or other active circuit device is included
                                in the parts list exhibit.




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 1 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com

         2.1033(c)(9)           Complete Circuit Diagrams: The circuit diagrams and
                                block diagrams are included.

         2.1033(c)(10)          Instruction book. The instruction manual is included.

         2.1033(c)(11)          Tune-up procedure.     The tune-up procedure is
                                included.

                                Description of all circuitry and devices provided for
                                determining and stabilizing frequency is included in
                                the circuit description

         2.1033(c)(11)          Digital modulation.    This unit does NOT use digital
                                modulation.

                                The data required by 2.1046 through 2.1055 is
                                submitted below.

         2.1046(a)              RF_power_output.
        80.215 (e)(1)
                                RF power is measured by connecting a 50 ohm, re-
                                sistive wattmeter to the RF output connector. With
                                a nominal battery voltage of 7.2 V, and the
                                transmitter properly adjusted the RF output measures:

                                OUTPUT POWER: HIGH:    5.0 W CONDUCTED
                                               LOW:    1.0 W CONDUCTED



                                METHOD OF MEASURING RF POWER OUTPUT



                 Transmitter                             50 ohm
                 under test                              Resistive
                                                         Wattmeter


                 Power
                 Supply




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 2 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com
                                TECHNICAL DATA:

        80.203 (b)              External Controls: The transmitter is capable of
                                changing frequency between 156.025 – 157.425 MHz by
                                external control. The available channels are shown
                                in the User Manual description Channel List. These
                                channels are preprogrammed by the manufacturer and
                                change of frequency is inaccessible to the station
                                operator.

        80.203 (c)              Five minutes continuous transmission test. The
                                antenna was connected to a dummy load and the radio
                                was locked in a transmit PTT mode. An external timer
                                digital clock was used to observe the duration of the
                                un-modulated transmission. The transmitter turned
                                off and the radio went to receive mode at 4 minutes,
                                58 seconds as displayed by the external digital
                                clock.




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 3 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com


         2.1047(a)              Voice Modulation_characteristics:

                  (b)           AUDIO_FREQUENCY_RESPONSE
                                See the following plot.




                        732aut4 audio frequency response


           +10


            +0
  d
  B         -10


            -20


            -30
              100        200            500            1k        2.85988k
                                                                 2k         5k   10k   20k
                                                            Hz




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 4 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com


         2.1047(a)
         80.213(e)              AUDIO_LOW_PASS_FILTER
                                The audio low pass filter shown in the following
                                plot.




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 5 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com


         2.1047(b)              Audio input versus modulation
        80.213 (a)(2)           A plot of the audio input versus deviation is
                                shown in the following plots.



                                         732AUT4 Modulation Limiting


          5




 k
 H
 z




          0
          -30    -27.5    -25    -22.5    -20   -17.5    -15   -12.5   -10   -7.5   -5   -2.5
                                                        dBu




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 6 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com


         2.1049(c)              Occupied bandwidth:

        80.211 (f)
                                Data in the plots shows that on any frequency removed
                                from the assigned frequency by more than 50%, but not
                                more than 100%: At least 25dB. On any frequency
                                removed from the assigned frequency by more than
                                100%, but not more than 250%: At least 35dB. On any
                                frequency removed from the assigned frequency by more
                                than 250%, of the authorized bandwidth:
                                At least 43 + log(P)dB.


                                Radiotelephone transmitter with modulation limiter.

                                Test procedure: TIA/EIA-603 para 2.2.11, with the
                                exception that various tones were used.


                                       Test procedure diagram


                                   OCCUPIED BANDWIDTH MEASUREMENT



                 Transmitter                                    Spectrum
                 under test                  Coupler            Analyzer



                 Audio
                 Oscillator




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 7 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com



                                     OCCUPIED BANDWIDTH PLOT




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 8 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com

         2.1051                 Spurious_emissions_at_antenna_terminals(conducted):
        80.211                  The data on the following page shows the level of
                                conducted spurious responses. The carrier was modu-
                                lated 100% using a 2500Hz tone. The spectrum was
                                scanned from 0.4 to at least the 10th harmonic of
                                the fundamental. The measurements were made in
                                accordance with standard TIA/EIA-603.

        REQUIREMENTS:           Emissions must be 43 + 10log(Po) dB below the
                                mean power output of the transmitter.

        43 + 10log(5) = 50                      43 + 10log(1) = 43

     TF                          dB below                  TF               dB below
HIGH POWER           EF           carrier              LOW POWER       EF    carrier
    156            156              0.0                   156        156       0.0
                    312            91.0                               312     82.5
                    468            79.0                               468     78.4
                    624            83.2                               624     84.2
                    780            87.6                               780     88.3
                    936            94.6                               936     93.9
                   1092            95.1                              1092     95.1
                   1248            97.2                              1248     93.4
                   1404            97.4                              1404     95.5
                   1560            96.7                              1560     97.0

     TF                          dB below                  TF               dB below
HIGH POWER           EF           carrier              LOW POWER       EF    carrier
    157            157              0.0                   157        157       0.0
                    314            90.0                               314     81.8
                    471            79.3                               471     78.5
                    628            83.4                               628     84.7
                    785            89.8                               785     89.3
                    942            94.5                               942     94.4
                   1099            95.2                              1099     95.1
                   1256            99.7                              1256     93.8
                   1413            98.4                              1413     96.1
                   1570            96.0                              1570     98.8




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 9 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com




                    Method of Measuring Conducted Spurious Emissions




                                                                       HP
                                                                       Spectrum
                                                                       Analyzer
                                                                       8566B



            TRANSMITTER
            UNDER TEST                                  ATTENUATOR




METHOD OF MEASUREMENT: The procedure used was TIA/EIA-603 STANDARD without
any exceptions. An audio generator was connected to the UUT through a dummy
microphone circuit and the output of the transmitter connected to a standard
load and from the standard load through a pre-selector filter of the spectrum
analyzer. The spectrum was scanned from 400kHz to at least the tenth harmonic
of the fundamental using a HP model 8566B spectrum analyzer. The measurements
were made using the shielded room located at TIMCO ENGINEERING INC. 849 STATE
ROAD 45, NEWBERRY FLORIDA 32669.




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 10 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com

         2.1053(a)              Field_strength_of_spurious_emissions:
        80.211
        NAME OF TEST:           RADIATED SPURIOUS EMISSIONS (156MHz)

        REQUIREMENTS:           Emissions must be 43 + 10log(Po) dB below the
                                mean power output of the transmitter.

                                HIGH:           43 + 10log(5) = 50
                                LOW:            43 + 10log(1) = 43
            TEST DATA:
                                HIGH POWER:
                                 Emission   Ant. Corrected Coax Substitution    dB
                                Frequency Polarity    EUT  Loss    Antenna    Below
                                    MHz             Signal (dB)     (dBd)    Carrier
                                                   Reading                    (dBc)
                                    156.00   V      27.20    0      -0.23       0
                                    312.00       H     -34.60    0     -1.25    62.82
                                    468.00       V     -46.20    0     -0.522   73.692
                                    624.10       V     -45.10    0     -0.257   72.327
                                    780.20       V     -48.90    0     -1.308   77.178
                                    936.20       H     -60.20    0     -0.984   88.154
                                   1092.20       V     -58.50   1.12    3.32    83.27
                                   1248.20       V     -52.10   1.5     3.94    76.63
                                   1404.20       V     -55.60   1.18    4.57    79.18
                                   1560.30       H     -57.10   1.21    4.97    80.31

                                LOW POWER:
                                 Emission   Ant. Corrected Coax Substitution    dB
                                Frequency Polarity    EUT  Loss    Antenna    Below
                                    MHz             Signal (dB)     (dBd)    Carrier
                                                   Reading                    (dBc)
                                    156.00   V      21.70    0      -0.23       0
                                    312.00       H     -41.60    0     -1.25    64.32
                                    468.00       V     -56.40    0     -0.522   78.392
                                    624.10       V     -59.30    0     -0.257   81.027
                                    780.20       H     -51.50    0     -1.308   74.278
                                    936.20       H     -58.40    0     -0.984   80.854
                                  1092.20        V     -61.60   1.12   3.32     80.87
                                  1248.20        V     -61.10   1.5    3.94     80.13
                                  1404.20        V     -62.50   1.18   4.57     80.58


          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 11 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com

         2.1053(a)              Field strength of spurious emissions:
        80.211
        NAME OF TEST:           RADIATED SPURIOUS EMISSIONS (157MHz)

        REQUIREMENTS:           Emissions must be 43 + 10log(Po) dB below the
                                mean power output of the transmitter.

                                HIGH:           43 + 10log(5) = 50
                                LOW:            43 + 10log(1) = 43

            TEST DATA:
                                 HIGH POWER:
                                  Emission   Ant. Corrected Coax Substitution    dB
                                 Frequency Polarity    EUT  Loss    Antenna    Below
                                     MHz             Signal (dB)     (dBd)    Carrier
                                                    Reading                    (dBc)

                                      157.40       V    25.30        0    -0.202     0
                                      314.80       H    -36.10       0    -1.25    62.448
                                      742.20       V    -45.20       0    -0.539   70.837
                                      629.60       V    -51.10       0    -0.232    76.43
                                      787.10       H    -52.40       0    -1.144   78.642
                                      944.50       H    -57.00       0    -1.084   83.182
                                    1101.80        V    -60.60   1.0072   3.357    83.3482
                                    1259.20        V    -57.40   1.0368   3.987    79.5478
                                    1416.60        V    -62.00   1.0664   4.616    83.5484

                                 LOW POWER:
                                  Emission   Ant. Corrected Coax Substitution     dB
                                 Frequency Polarity    EUT  Loss    Antenna     Below
                                     MHz             Signal (dB)     (dBd)    Carrier
                                                    Reading                     (dBc)
                                     157.40   V      20.10    0     -0.202         0
                                     314.80   H     -36.10    0      -1.25     57.248
                                      742.20       V    -64.00       0    -0.539   84.437
                                      629.60       V    -53.80       0    -0.232    73.93
                                      787.10       H    -49.30       0    -1.144   70.342
                                      944.50       V    -57.40       0    -1.084   78.382
                                    1101.80        V    -62.60   1.0072   3.357    80.1482
                                    1259.20        V    -61.80   1.0368   3.987    78.7478
                                    1416.60        V    -62.80   1.0664   4.616    79.1484



          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 12 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com




                    Method of Measuring Radiated Spurious Emissions




                                                                    Hewlett Packard
                                                                        Spectrum
                                                                        Analyzer
                                                                        HP8555A



             TRANSMITTER                50 OHM RESISTIVE
             UNDER TEST                 LOAD



                                                           <-3.0 meters-->

                                                           Tuned, Calibrated
                                                           Antenna which may
                                                           be raised from 1m
                                                           to 4m above ground
            POWER SUPPLY                                   and changed
                                                           in polarization



          Equipment placed 80 cm above ground
          on a rotatable platform.



METHOD OF MEASUREMENT: The tabulated data shows the results of the radiated
field strength emissions test. The spectrum was scanned from 30 to at least
the tenth harmonic of the fundamental. This test was conducted per TIA/EIA
STANDARD 603 using the substitution method. Measurements were made at the
open field test site of TIMCO ENGINEERING, INC. located at 849 N.W. State
Road 45, Newberry, FL   32669.




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 13 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com

                               Frequency stability:
         2.1055(a)(2)
        80.209 (a)
              Temperature and voltage tests were performed to verify that the
              frequency remains within the .0010%, 10.0ppm specification limit,
              for 20kHz spacing. The test was conducted as follows: The
              transmitter was placed in the temperature chamber at 25º C and
              allowed to stabilize for one hour. The transmitter was keyed ON
              for one minute during which four frequency readings were recorded
              at 15 second intervals. The worse case number was taken for
              temperature plotting. The assigned channel frequency was
              considered to be the reference frequency. The temperature was
              then reduced to -30º C after which the transmitter was again
              allowed to stabilize for one hour. The transmitter was keyed ON
              for one minute, and again frequency readings were noted at 15 sec
              intervals. The worst-case number was recorded for temperature
              plotting. This procedure was repeated in 10-degree increments up
              to + 50º C.

                Readings were also taken at minus 25% of the battery voltage of
                7.2 V, which we estimate to be the battery endpoint.


                                               MEASUREMENT DATA:

                 Assigned Frequency (Ref. Frequency):               156.050 002 MHz

                 TEMPERATURE_C                 FREQUENCY MHz            PPM

                 REFERENCE_____________156.050         002             00.0
                 -30___________________156.049         653            -2.24
                 -20___________________156.049         762            -1.54
                 -10___________________156.049         786            -1.38
                   0___________________156.049         864            -0.88
                 +10___________________156.049         893            -0.70
                 +20___________________156.049         97             -0.21
                 +30___________________156.050         022             0.13
                 +40___________________156.050         088             0.55
                 +50___________________156.050         148             0.94

                                VOLTS          Batt. Data          Batt. PPM
                 -15%           6.12           156.050 022              0.13

                RESULTS OF MEASUREMENTS:           The test results indicates that the EUT
                meets the requirements.




          APPLICANT: VERTEX STANDARD CO., LTD.
             FCC ID: K6630073X20
           REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                           Page 14 of 15


TIMCO ENGINEERING INC.
849 NW State Road 45
Newberry, Florida 32669
http://www.timcoengr.com
888.472.2424 F 352.472.2030 email: sid@timcoengr.com




                                 EMC Equipment List
   Device        Manufacturer           Model           Serial        Cal/Char     Due Date
                                                        Number           Date
 3/10-Meter            TEI                N/A             N/A          Listed       3/26/07
      OATS                                                             3/27/04
    3-Meter            TEI                N/A             N/A          Listed       1/13/06
      OATS                                                             1/13/03
     Audio            B&K                3010           8739686         CHAR        12/1/04
  Generator        Precision                                           12/1/02
     Audio             HP                653A          832-00260        CHAR        12/1/04
 Oscillator                                                            12/1/02
 Biconnical           Eaton            94455-1           1057       CAL 3/18/03    3/18/05
    Antenna
 Biconnical           Eaton            94455-1           1096       CAL 10/1/01    10/1/03
    Antenna
 Biconnical         Electro-            BIA-25            1171      CAL 4/26/01    4/26/03
    Antenna          Metrics
 Blue Tower             HP              85650A         2811A01279   CAL 4/15/03    4/15/05
 Quasi-Peak
    Adapter
 Blue Tower             HP              85685A         2620A00294                 out for Cal
       RF
Preselector
 Blue Tower             HP              8568B          2928A04729   CAL 4/15/03     4/15/05
   Spectrum                                            2848A18049
   Analyzer
  Frequency             HP              5352B          2632A00165       CAL        11/28/03
    Counter                                                           11/28/01
  Frequency             HP              5382A          1620A03535   CHAR 3/2/01     Out of
    Counter                                                                         Service
  Frequency             HP              5385A          2730A03025   CAL 3/7/03      3/7/05
    Counter
  Frequency             HP              5385A          3242A07460   CAL 3/7/03      3/7/05
    Counter
      LISN          Electro-          ANS-25/2            2604      CAL 10/9/01    10/9/03
                     Metrics
     LISN           Electro-           EM-7820            2682      CAL 3/12/03    3/12/05
                     Metrics
     Log-             Eaton             96005            1243       CAL 5/8/03      5/8/05
  Periodic
   Antenna




            APPLICANT: VERTEX STANDARD CO., LTD.
               FCC ID: K6630073X20
             REPORT #: V\VERTEX\732AUT4\732AUT4TestReport.doc
                                                             Page 15 of 15



Document Created: 2004-07-02 13:40:45
Document Modified: 2004-07-02 13:40:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC