Test lab response to FCC request

FCC ID: K6630053X30

Cover Letter(s)

Download: PDF
FCCID_383801

Date:         December 16, 2003


To:           Stan Lyles, FCC

Applicant: Vertex Standard Co., Ltd.
Equipment: FCC ID: K6630053X30 TC787589
Reference: Correspondence Number 10349


Stan:

2)     You have raised some interesting questions in this correspondence to Timco.
With due respect, the environmental assessment report page 7 accompanying this
submission only shows the limits for General Population/Uncontrolled Exposure, which
for VHF indicates a power density of 0.200 mw/cm^2. Safety Instructions to Installers
and Users should have indicated to you that the actual limit used was 1.0 mw/cm^2 for
30-300 MHz and that this limit was readily achieved at 50 cm as shown on page 7 and
on the Timco Certificate and for 50% DCF (12.5 w) with a 0 dBd antenna as shown on
the mandatory instruction sheet in the Environmental Assessment Report.

1)      Since we have had the A2LA accreditors examine our probe calibration and
certificates as part of their annual visit, I would suggest to you that the copies of the
certificates would only result in a needless waste of our time and our paper.

3)    The User Manual will be changed to show a 0 dBd antenna as indicated in the EA
Report and mandatory instructions.

Trust this meets the requirements of the Commission.



                                                         Best regards,



                                                         Mort Flom, P. Eng., President



Document Created: 2003-12-16 10:07:13
Document Modified: 2003-12-16 10:07:13