Test Report

FCC ID: K6620345X40

Test Report

Download: PDF
FCCID_2765017

                                                                                       Issue Date: 18 Aug. 2015
                                                                                       Report No.: ERY1508P18R1
                                                                                       Model: FTM-400XDR




                                         TEST REPORT
                                                                   For

                            144/430 MHz Dual Band Transceiver
                                                          In conformity with

                                       FCC CFR 47 Part15 Subpart B


         Model                    : FTM-400XDR

         FCC ID                   : K6620345X40

         Test Item                : 144/430 MHz Dual Band Transceiver

         Report No. : ERY1508P18R1

         Issue Date               : 18 Aug. 2015




            Prepared for
                                YAESU MUSEN CO., LTD.
                                  Tennozu Parkside Building 2-5-8 Higashi-Shinagawa,
                                  Shinagawa-ku, Tokyo 140-0002 JAPAN

            Prepared by
                                SGS RF Technologies Inc.
                                  3-5-23, Kiyatamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
                                  Telephone: +81+(0)45- 550-3520
                                  FAX: +81+(0)45- 592-7506




SGS RF Technologies Inc.                                                                             Page 1 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                       Issue Date: 18 Aug. 2015
                                                                                       Report No.: ERY1508P18R1
                                                                                       Model: FTM-400XDR



     This document is issued by the Company subject to its General Conditions of Service printed overleaf,
     available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
     format documents, subject to Terms and Conditions for Electronic Documents at
     www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
     indemnification and jurisdiction issues defined therein. Any holder of this document is advised that
     information contained hereon reflects the Company’s findings at the time of its intervention only and
     within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client
     and this document does not exonerate parties to a transaction from exercising all their rights and
     obligations under the transaction documents. This document cannot be reproduced except in full,
     without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
     of the content or appearance of this document is unlawful and offenders may be prosecuted to the
     fullest extent of the law.
     SGS RF Technologies Inc. is managed to ISO17025 and has the necessary knowledge and test
     facilities for testing according to the referenced standards. The test results in this report apply only
     to the sample tested.




SGS RF Technologies Inc.                                                                             Page 2 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                                                                     Issue Date: 18 Aug. 2015
                                                                                                                                     Report No.: ERY1508P18R1
                                                                                                                                     Model: FTM-400XDR


Table of contents
1      General information ...................................................................................................................... 4
    1.1     Product description ................................................................................................................................................ 4
    1.2     Test(s) performed/ Summary of test result ............................................................................................................ 4
    1.3     Test facility ............................................................................................................................................................ 5
    1.4     Measurement uncertainty ....................................................................................................................................... 5
    1.5     Summary of test results.......................................................................................................................................... 6
    1.6     Setup of equipment under test (EUT) .................................................................................................................... 6
       1.6.1     Test configuration of EUT ............................................................................................................................. 6
       1.6.2     Operating condition: ...................................................................................................................................... 6
       1.6.3     Setup diagram of tested system...................................................................................................................... 7
    1.7     Equipment modifications ....................................................................................................................................... 7
    1.8     Deviation from the standard .................................................................................................................................. 7
2      Test procedure and test data ........................................................................................................ 8
    2.1        Radiated emissions ................................................................................................................................................ 8
    2.2        AC power line conducted emissions .................................................................................................................... 11
3      Test setup photographs ............................................................................................................... 13
    3.1        Radiated emissions .............................................................................................................................................. 13
    3.2        AC power line conducted emissions .................................................................................................................... 13
4      List of utilized test equipment / calibration .............................................................................. 14




History
             Report No.                       Date                                           Revisions                                                                Issued By
           ERY1508P17R1                   17 Aug. 2015                Initial Issue                                                                                     T.Kato
           ERY1508P18R1                   18 Aug. 2015                Revise the purpose of this test (Page 4)                                                          T.Kato




SGS RF Technologies Inc.                                                                                                                                     Page 3 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                           Issue Date: 18 Aug. 2015
                                                                                           Report No.: ERY1508P18R1
                                                                                           Model: FTM—400XDR


 1     General information

 1.1 Product description
         Test item                                 : 144/430 MHz Dual Band Transceiver
         Manufacturer                              : YAESU MUSEN CO., LTD.
         Address                                   : 43 Utsuroda, Morijuku, Sukagawa—shi, Fukushima—ken 962—0001 JAPAN
         Model                                     : FTM—400XDR
         FCC ID                                    : K6620345X40
         Serial number                            : 3K030471
         Hardware version                         : 3K03.G
         Software version                         : 3K03
         Highest internal operating Freq.         : 502.47 MHz
         Receipt date of EUT                      : 23 Jul. 2015
         Nominal power source voltages            : DC 13.8 V


 1.2     Test(s) performed/ Summary of test result

         Test specification(s)                      : FCC CFR 47 Part 15 Subpart B (01 Oct. 2014)
         Test method(s)                             : ANSI C€63.4: 2009
         Test(s) started                            :28 Jul. 2015
         Test(s) completed                          : 28 Jul. 2015
         Purpose oftest(s)                          : Certification (the change of GPS module)

         Summary oftest result                      : Complied



       Note: The above judgment is only based on the measurement data and it does not include the measurement
             uncertainty. Accordingly, the statement below is applied to the test result.
             The EUT complies with the limit required in the standard in case that the margin is not less than the
             measurement uncertainty in the Laboratory.
             Compliance of the EUT is more probable than non—compliance is case that the margin is less than the
             measurement uncertainty in the Laboratory.



Test engineer                                       ZEA—
                                                    T. Kato
                                                    EMC testing Department


Reviewer                                                                        5

                                                    K. Onishi
                                                    Manager
                                                    EMC testing Department




SGS RF Technologies Inc.                                                                                  Page 4 of 14
3—5—23, Kitayamata, Tsuzuki—ku, Yokohama, 224—0021, Japan
Telephone: +81+(0)45— 550—3520, FAX: +81+(0)45— 592—7506, Web: http://www.rf—test.jp


                                                                                       Issue Date: 18 Aug. 2015
                                                                                       Report No.: ERY1508P18R1
                                                                                       Model: FTM-400XDR


1.3 Test facility
        The Federal Communications Commission has reviewed the technical characteristics of the test facilities at
        SGS RF Technologies Inc., located in 472, Nippa-cho, Kohoku-ku, Yokohama, 223-0057, Japan, and
        has found these test facilities to be in compliance with the requirements of 47 CFR Part 15, section 2.948, per
        October 1, 2014.
        The description of the test facilities has been filed under registration number 319924 at the Office of the
        Federal Communications Commission. The facility has been added to the list of laboratories performing
        these test services for the public on a fee basis.
        The list of all public test facilities is available on the Internet at http://www.fcc.gov.

        Registered by Industry Canada (IC): The registered facility number is as follows;
        Test site No. 1 (Semi-Anechoic chamber 3m): 6974A-1

        Accredited by National Voluntary Laboratory Accreditation Program (NVLAP) for the emission tests
        stated in the scope of the certificate under Certificate Number 200780-0

        This report must not be used by the client to claim product certification, approval, or endorsement by
        NVLAP, NIST, or any agency of the Federal Government.




1.4 Measurement uncertainty
        The treatment of uncertainty is based on the general matters on the definition of uncertainty in “Guide to the
        expression of uncertainty in measurement (GUM)” published by ISO. The Lab’s uncertainty is determined
        by referring UKAS Publication LAB34: 2002 “The Expression of Uncertainty in EMC Testing” and
        CISPR16-4-2: 2011 “Uncertainty in EMC Measurements”.
        The uncertainty of the measurement result in the level of confidence of approximately 95% (k=2) is as
        follows;

        Conducted emission: ± 3.4 dB (150 kHz - 30 MHz)
        Radiated emission (9 kHz - 30 MHz): ± 3.3 dB
        Radiated emission (30 MHz - 200 MHz): ± 5.0 dB
        Radiated emission (200 MHz - 1000 MHz): ± 6.2 dB
        Radiated emission (1 GHz - 6 GHz): ± 4.7 dB




SGS RF Technologies Inc.                                                                              Page 5 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                                     Issue Date: 18 Aug. 2015
                                                                                                     Report No.: ERY1508P18R1
                                                                                                     Model: FTM-400XDR


1.5 Summary of test results
                                                                               Section                                     Section in
                              Requirement                                                               Result
                                                                           in specification                                this report
         Radiated emissions (30 to 5000 MHz) (*1)                               15.109                 Complied                2.1
         AC power line conducted emissions                                      15.107                 N/A (*2)               2.2
          (*1) The highest internal operating frequency is 502.47 MHz
          (*2) The EUT have no AC power line.


1.6 Setup of equipment under test (EUT)
1.6.1 Test configuration of EUT
Equipment(s) under test
      No.              Item                               Manufacture                         Model No.                Serial No.
       A    144/430MHz Dual Band                    YAESU MUSEN CO., LTD.                  FTM-400XDR                3K030471
            Transceiver
       -    -                                       -                                      -                         -

Support Equipment(s)
       No.           Item                           Manufacture                            Model No.              Serial No.
        B   Hand Microphone                   YAESU MUSEN CO., LTD.                    MH-48A6JA              1412167017
        C   External Speaker                  YAESU MUSEN CO., LTD.                    MLS-200-M10            060
        -   -                                 -                                        -                      -

Connected cable(s)
      No.                  Item                     Identification                         Cable           Ferrite            Length
                                                     (Manu.etc.)                          Shielded          Core               [m]
           1     Control cable                YAESU MUSEN CO., LTD.                         Yes              No                3.0
           2     Mic. cable                   YAESU MUSEN CO., LTD.                         No               No                0.5
           3     Speaker cable                YAESU MUSEN CO., LTD.                         No               No                3.0
           4     Data cable                   YAESU MUSEN CO., LTD.                         Yes              No                1.1
           5     DC power cable               YAESU MUSEN CO., LTD.                         No               No                2.8


1.6.2    Operating condition:

        Rx 999.9 MHz:          Transceiver is set to Rx mode at 999.9 MHz during GPS status is ON.


        Note:       The test was applied with one operating frequency only because there is no change of transceiver
                    circuit. (Manufacturer's request)




SGS RF Technologies Inc.                                                                                                 Page 6 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                       Issue Date: 18 Aug. 2015
                                                                                       Report No.: ERY1508P18R1
                                                                                       Model: FTM-400XDR

1.6.3 Setup diagram of tested system

                                   4                                                    5
                 Open
                                                                                                  DC 13.8V
                (Note)                                            A:
                                                              Transceiver
                                  2                                                    3
                                                              [Main unit]
                                                                (EUT)


                        B:                                                                     C:
                      Hand                                                                  External
                    Microphone                                                              Speaker


                                                                        1


                                                                 A:
                                                             Transceiver
                                                            [Control unit]
                                                               (EUT)



            Note: No AE were connected to these cable by the manufacturer's request.


1.7 Equipment modifications
        No modifications have been made to the equipment in order to achieve compliance with the applicable
        standards described in clause 1.2.


1.8 Deviation from the standard
        No deviations from the standards described in clause 1.2.




SGS RF Technologies Inc.                                                                               Page 7 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                           Issue Date: 18 Aug. 2015
                                                                                           Report No.: ERY1508P18R1
                                                                                           Model: FTM-400XDR


2 Test procedure and test data
2.1 Radiated emissions
Test setup
       Test setup was implemented according to the method of ANSI C63.4 clause 6 “General requirements
       for EUT equipment arrangements and operation”, clause 8.2 and Annex H.3 “Radiated emission
       measurements setup”.

                                                                                        Semi anechoic room



             1-4m
                                                Rx Antenna

                                                                                                 EUT
                                                                                3.0 m

                                                                                                                0.8 m




                 Pre-amplifier                 Test
                                             Receiver


Test procedure
      Measurement procedures were implemented according to the method of ANSI C63.4 clauses 8.2.
      The EUT is place on a non-conducted table which is 0.8 m height from a ground plane and the measurement
      antenna to EUT distance is 3 meters. The turn table is rotated for 360 degrees to determine the maximum
      emission level.
      The antenna height scanned between 1 m and 4 m, and the antenna rotated to repeat the measurements for
      both the horizontal and vertical antenna polarizations.
      The spectrum analyzer and receiver are set to the followings;
                RBW=100 kHz (up to 1000 MHz) or 1 MHz (above 1000 MHz) ,
                VBW= 300 kHz (up to 1000 MHz) or 3 MHz (above 1000 MHz)
                Final measurement is carried out with a receiver RBW of 120 kHz (up to 1000 MHz), or 1 MHz
                 (above 1000 MHz).

Applicable rule and limitation
      FCC 15.109 Radiated emissions limits

                 Frequency               Field Strength             Measurement      Field Strength
                    [MHz]                    [µV/m]                 Distance [m]       [dBµV/m]
                   30 – 88                     100                        3               40.0
                   88 –216                     150                        3               43.5
                 216 – 960                     200                        3               46.0
                 Above 960                     500                        3               53.9
        In the emission table above, the tighter limit applies at the band edges.
        The emission limits shown in the above table are based on measurements employing a QP detector (up to
        1000 MHz) or AVE/PEAK detector (above 1000 MHz).



SGS RF Technologies Inc.                                                                                 Page 8 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                                   Issue Date: 18 Aug. 2015
                                                                                                   Report No.: ERY1508P18R1
                                                                                                   Model: FTM-400XDR



Test results - Complied with requirement


Test equipment used (refer to List of utilized test equipment)

              AC01          TR06           CL11            PR15           BA10           CL29         CL30
              PR12          DH01

Test software used
      EMI Ver. 5.6

Calculation method
      The Correction Factor and Result are calculated as followings.

                     Correction Factor [dB/m] = Ant. Factor [dB/m] + Loss [dB] – Gain [dB]
                     Result [dBµV/m] = Reasding [dBµV] + Correction Factor [dB/m]

Test Data

        Range: 30 - 1000 MHz
                Frequency  Reading              Factor        Loss         Gain          Result       Limit       Margin
         No.                                                                                                                  Ant.
                  [MHz]    [dBµV]               [dB/m]        [dB]         [dB]        [dBµV/m]     [dBµV/m]       [dB]
          1      221.188     48.5                10.5          8.7         29.9           37.8         46.0         8.2       Hori.
          2      344.067     50.4                14.4          9.5         29.9           44.4         46.0         1.6       Hori.
          3      113.646     43.6                10.9          7.8         30.1           32.2         43.5        11.3       Vert.
          4      122.883     44.2                11.4          7.9         30.1           33.4         43.5        10.1       Vert.
          5      141.274     41.6                11.5          8.0         30.0           31.1         43.6        12.4       Vert.
          6      221.187     45.6                10.5          8.7         29.9           34.9         46.0        11.1       Vert.
          7      230.423     44.9                11.1          8.7         29.9           34.8         46.0        11.2       Vert.

        Range: 1000 MHz - 5000 MHz
                                Reading     Reading                    Result   Result   Limit    Limit Margin Margin
                Frequency                               C.Factor
         No.      [MHz]
                                  PK         AVE
                                                        [dB/m]
                                                                        PK      AVE       PK      AVE     PK    AVE           Ant.
                                [dBµV]      [dBµV]                   [dBµV/m] [dBµV/m] [dBµV/m] [dBµV/m] [dB] [dB]
          1      1032.206         52.6        47.0        -11.6        41.0       35.4      73.9       53.9    32.9   18.5    Hori
          2      1130.509         52.4        46.9        -10.8        41.6       36.4      73.9       53.9    32.3   17.8    Hori.
          3      1228.816         50.3        44.2        -10.1        40.2       34.1      73.9       53.9    33.7   19.8    Hori.
          4      1032.204         53.3        48.6        -11.6        41.7       37.0      73.9       53.9    32.2   16.9    Vert.
          5      1130.509         52.6        47.4        -10.8        41.8       36.6      73.9       53.9    32.1   17.3    Vert.
          6      1228.816         49.7        42.8        -10.1        39.6       32.7      73.9       53.9    34.3   21.2    Vert.




SGS RF Technologies Inc.                                                                                         Page 9 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                                 Issue Date: 18 Aug. 2015
                                                                                                 Report No.: ERY1508P18R1
                                                                                                 Model: FTM-400XDR

        [Chart]




        [Test condition]

                            Tested Date: 28 Jul. 2015                            Temperature:    24 degC
                            Humidity:    54 %                                    Atmos. Press:   1006 hPa




SGS RF Technologies Inc.                                                                                       Page 10 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                       Issue Date: 18 Aug. 2015
                                                                                       Report No.: ERY1508P18R1
                                                                                       Model: FTM-400XDR

2.2     AC power line conducted emissions
Test setup
       Test setup was implemented according to the method of ANSI C63.4 clause 6 “General requirements
       for EUT equipment arrangements and operation” and Annex H.1 “AC power line conducted emission
       measurements setup”.

Test procedure
      Measurement procedures were implemented according to the method of ANSI C63.4 clauses 7, clause
      13.1.3 and Annex H.2 “AC power line conducted emission measurements”.
      Exploratory measurements were used the spectrum analyzer to identify the frequency of the emission that has
      the highest amplitude relative to the limit by operating the EUT in a range of typical modes of operation,
      cable positions, and with a typical system equipment configuration and arrangement.
      Final ac power line conducted emission measurements were performed based on the exploratory tests.
      The EUT cable configuration and arrangement and mode of operation that produced the emission with the
      highest amplitude relative to the limit are selected for the final measurement.
      When the measurement value is grater than average limitation the average detection measurements were
      performed.


Applicable rule and limitation
      §15.107 (b) AC power line conducted limits
                 Frequency of Emission         Conducted emissions Limit [dBµV]
                         [MHz]                  Quasi-peak             Average
                       0.15 - 0.5                66 to 56 *           56 to 46 *
                         0.5 - 5                     56                   46
                          5 - 30                     60                   50
      * Decreases with the logarithm of the frequency. The lower limit applies at the band edges.

Test equipment used (refer to List of utilized test equipment)




Test software used
      EMI Ver. 5.6


Calculation method
      The Correction Factor and Result are calculated as followings.

                    Correction Factor [dB] = ISN Factor [dB] + Loss [dB]
                    Result [dBµV] = Reading [dBµV] + Correction Factor [dB]


Test results - This item was not tested.




SGS RF Technologies Inc.                                                                             Page 11 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                                Issue Date: 18 Aug. 2015
                                                                                                Report No.: ERY1508P18R1
                                                                                                Model: FTM-400XDR

Test Data

   [Emission level]

                                       Reading                                Result            Limit
                   Frequency                                C.F.
           No.                      QP       AV                          QP          AV       QP       AV      Phase
                     [MHz]                                  [dB]
                                  [dBµV] [dBµV]                        [dBµV]      [dBµV]   [dBµV]   [dBµV]
             -          -            -         -              -           -           -        -        -        -
             -          -            -         -              -           -           -        -        -        -

   [Chart]




  [Test condition]

        Tested Date:        -                                Temperature:        - degC
        Humidity:           -%                               Atmos. Press:       - hPa




SGS RF Technologies Inc.                                                                                      Page 12 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp


                                                                                                    Issue Date: 18 Aug. 2015
                                                                                                    Report No.: ERY1508P18R1
                                                                                                    Model: FTM-400XDR


4 List of utilized test equipment / calibration
    RFT           Kind of Equipment and                                                                 Calibration
                                                   Manufacturer           Model No.     Serial Number                   Calibrated until
   ID No.               Precision                                                                          Date
 AC01(EM) Anechoic Chamber (1st test room)               JSE               203397C            -          2015/4/18        2016/4/30

 AC01(EG)     Anechoic Chamber (1st test room)           JSE               203397C            -         2014/11/24       2015/11/30

   BA10               Bilogical Antenna                TESEQ              CBL6111D         32342         2015/6/12        2016/6/30

   CL11               RF Cable for RE                   RFT                   -               -          2015/3/13        2016/3/31

   CL29                RF Cable 2 m                   SUHNER            SUCOFLEX104PE      94709         2015/1/26        2016/1/31

   CL30                RF Cable 5 m                   SUHNER            SUCOFLEX104PE     MY3599         2014/8/28        2015/8/31

   DH01              DRG Horn Antenna               A.H. Systems           SAS-571          785          2014/1/21        2016/1/31

   PR12             Pre. Amplifier (1-26G)       Agilent Technologies       8449B       3008A02513       2015/1/26        2016/1/31

   PR15                 Pre. Amplifier                 Anritsu             MH648A       6201156141       2015/6/13        2016/6/30
                        Test Receiver
   TR06                                           Rohde & Schwarz           ESU26          100002        2014/9/5         2015/9/30
                      (F/W : 3.93 SP2)

        The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated
        in accordance with the manufacturer's recommendations for utilizing calibration equipment, which is
        traceable to recognized national standards.




SGS RF Technologies Inc.                                                                                              Page 14 of 14
3-5-23, Kitayamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520, FAX: +81+(0)45- 592-7506, Web: http://www.rf-test.jp



Document Created: 2015-09-25 09:12:05
Document Modified: 2015-09-25 09:12:05

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC