TEST REPORT

FCC ID: K6620233X40

Test Report

Download: PDF
FCCID_601497

                             TABLE OF CONTENTS LIST



APPLICANT:    VERTEX STANDARD CO., LTD.

FCC ID:       K6620233X40


TEST REPORT CONTAINING:

      PAGE   1......TEST PROCEDURE
      PAGE   2......TEST PROCEDURE & CIRCUIT DESCRIPTION
      PAGE   3......RADIATION INTERFERENCE TEST DATA
      PAGE   4......38 dB Rejection Ratio


EXHIBITS CONTAINING:

       CONFIDENTIALITY REQUEST LETTER
       STATEMENT PER 15.121(a)
       BLOCK DIAGRAMS
       SCHEMATICS
       INSTRUCTION MANUAL
       SAMPLE OF FCC ID LABEL AND SKETCH OF LOCATION
       RADIATED TEST SETUP PHOTOGRAPH
       EXTERNAL PHOTOS
       INTERNAL PHOTOS
       CIRCUIT DESCRIPTION




APPLICANT:   VERTEX STANDARD CO., LTD.
   FCC ID:   K6620233X40
 REPORT #:   V\VERTEX\2091UT5\2091UT5TestReport.doc

                                                           TABLE OF CONTENTS


APPLICANT:    VERTEX STANDARD CO., LTD.
FCC ID:       K6620233X40



                               TEST EQUIPMENT LIST

  Device       Manufacturer     Model        Serial       Cal/Char    Due Date
                                             Number         Date
 3/10-Meter        TEI           N/A           N/A         Listed     3/26/07
     OATS                                                 3/27/04
   3-Meter         TEI           N/A          N/A          Listed     1/12/06
     OATS                                                 1/13/03
 Biconnical       Eaton        94455-1        1057      CAL 3/18/03   3/18/05
   Antenna
 Biconnical       Eaton        94455-1        1096      CAL 8/17/04   8/17/06
   Antenna
 Biconnical      Electro-       BIA-25        1171      CAL 4/29/05   4/29/07
   Antenna        Metrics
 Blue Tower          HP         85650A     2811A01279   CAL 4/13/05   4/13/07
 Quasi-Peak
   Adapter
 Blue Tower         HP          85685A     2926A00983   CAL 8/3/05    8/3/07
      RF
Preselector
 Blue Tower         HP          8568B      2928A04729   CAL 4/13/05   4/13/07
  Spectrum                                 2848A18049
  Analyzer
     LISN        Electro-      ANS-25/2       2604      CAL 8/27/04   8/27/06
                  Metrics
   LISN          Electro-      EM-7820        2682      CAL 4/28/05   4/28/07
                  Metrics
    Log-           Eaton        96005         1243      CAL 5/8/03    5/8/05
 Periodic
  Antenna




APPLICANT:    VERTEX STANDARD CO., LTD.
   FCC ID:    K6620233X40
 REPORT #:    V\VERTEX\2091UT5\2091UT5TestReport.doc

                                                              Page 1 of 4


                                 TEST PROCEDURE

GENERAL: This report shall NOT be reproduced except in full without the written
approval of TIMCO ENGINEERING, INC.

RADIATION INTERFERENCE: The test procedure used was ANSI STANDARD C63.4-2003
using a HEWLETT PACKARD spectrum analyzer with a preselector. The bandwidth of
the spectrum analyzer was 100 kHz with an appropriate sweep speed. The analyzer
was calibrated in dB above a microvolt at the output of the antenna. The
resolution bandwidth was 100KHz and the video bandwidth was 300KHz. The ambient
temperature of the UUT was 80oC with a humidity of 76%.

FORMULA OF CONVERSION FACTORS: The Field Strength at 3m was established by
adding the meter reading of the spectrum analyzer (which is set to read in units
of dBuV) to the antenna correction factor supplied by the antenna manufacturer.
The antenna correction factors are stated in terms of dB. The gain of the
Preselector was accounted for in the Spectrum Analyzer Meter Reading.

      Example:
      Freq (MHz) METER READING + ACF = FS
      33         20 dBuV + 10.36 dB = 30.36 dBuV/m @ 3m

ANSI STANDARD C63.4-2003 10.1.7 MEASUREMENT PROCEDURES: The unit under test was
placed on a table 80 cm high and with dimensions of 1m by 1.5m. The table used
for radiated measurements is capable of continuous rotation.

When an emission was found, the table was rotated to produce the maximum signal
strength. At this point, the antenna was raised and lowered from 1m to 4m. The
antenna was placed in both the horizontal and vertical planes.




APPLICANT:   VERTEX STANDARD CO., LTD.
   FCC ID:   K6620233X40
 REPORT #:   V\VERTEX\2091UT5\2091UT5TestReport.doc

                                                             Page 2 of 4


APPLICANT:               VERTEX STANDARD CO., LTD.

FCC ID:                  K6620233X40

NAME OF TEST:            RADIATION INTERFERENCE

RULES PART NUMBER:       15.109

REQUIREMENTS:            30 to 80 MHz:     40.0    dBuV/M @ 3 METERS
                         88 to 216 MHz:    43.5    dBuV/M
                         216 to 960 MHz:   46.0    dBuV/M
                         ABOVE 960 MHz:    54.0    dBuV/M

TEST RESULTS: A search was made of the spectrum from 30 to 1000 MHz and the
measurements indicate that the unit DOES meet the FCC requirements.


TEST DATA:
  Tuned       Emission    Meter    Ant.      Coax      Correction        Field    Margin
Frequency    Frequency   Reading    Pol      Loss        Factor        Strength     dB
   MHz           MHz       dBuV               dB           dB           dBuV/m
  136.0        114.30     10.9         V     0.66        14.95          26.51     16.99
  136.0        114.30     11.0         H     0.66        14.84          26.50     17.00
  136.0        342.90     11.7         H     1.14        15.13          27.97     18.03
  136.0        457.20     10.7         H     1.26        17.32          29.28     16.72
  136.0        571.50     10.4         H     1.51        19.32          31.23     14.77
  155.0        133.30     10.8         H     0.68        13.10          24.58     18.92
  155.0        133.30     10.9         V     0.68        13.14          24.72     18.78
  155.0        399.90     12.0         H     1.20        16.10          29.30     16.70
  155.0        399.90     12.2         V     1.20        16.00          29.40     16.60
  155.0        666.50     10.5         H     1.67        20.73          32.90     13.10
  174.0        152.30     10.1         V     0.71        14.34          25.15     18.35
  174.0        152.30     10.3         H     0.71        14.17          25.18     18.32
  174.0        456.90     10.5         V     1.26        16.87          28.63     17.37
  174.0        456.90     11.9         H     1.26        17.31          30.47     15.53
  174.0        609.20     10.4         V     1.61        18.60          30.61     15.39
  174.0        761.50     11.2         V     1.82        20.39          33.41     12.59

SAMPLE CALCULATION:   FSdBuV/m = MR (dBuV) + ACFdB.

TEST PROCEDURE: ANSI STANDARD C63.4-2003 using a Hewlett Packard Model 8566B
spectrum analyzer, a Hewlett Packard Model 85685A Preselector, a Hewlett Packard
Model 85650A Quasi-Peak adapter, an Electro-Metric Dipole Kit, and an Eaton
Model 94455-1 Biconical Antenna. The bandwidth of spectrum analyzer was 100 kHz
with an appropriate sweep speed. When an emission was found, the table was
rotated to produce the maximum signal strength. The antenna was placed in both
the horizontal and vertical planes and the worse case emissions were reported.
The receiver was put into the coherent mode by placing an antenna driven by a
signal generator off site. The UUT was tested in 3 orthogonal planes.


PERFORMED BY: JOSEPH SCOGLIO               DATE:    OCTOBER 26, 2005

APPLICANT:   VERTEX STANDARD CO., LTD.
   FCC ID:   K6620233X40
 REPORT #:   V\VERTEX\2091UT5\2091UT5TestReport.doc

                                                                 Page 3 of 4


APPLICANT:                VERTEX STANDARD CO., LTD.

FCC ID:                   K6620233X40

NAME OF TEST:             38dB REJECTION RATIO

RULES PART NUMBER:        15.121(b)

REQUIREMENTS:             38dB REJECTION RATIO TO SENSITIVITY OF THE RECEIVER.

TEST SET-UP




TEST PROCEDURE:  The reference sensitivity was measured in accordance with
                 TIA/EIA-603;
a.   Equipment connected as illustrated
b.   A standard signal was applied to the receiver input terminals.
c.   Receiver output audio output was adjusted for rated output.
d.   The RF Signal generator was adjusted to the lowest level to produce a 12dB
     SINAD without the audio output dropping more than 3dB. Make note of
     sensitivity level.
e.   This was done across the different bands to establish a reference level.
     The reference taken was the worse case sensitivity.
f.   The output of the signal generator was then adjusted to a level of 60dB
     above the reference level at a frequency of 824.5MHz.
g.   With the level set 60dB above the level measured in step e.
h.   Set squelch on receiver to threshold, the signal level required to open
     the squelch must be lower than the level measured in step d.
i.   Cause the receiver to scan or step-it through its complete range of
     frequencies.
j.   If receiver stops or unsquelches on any frequency, record the frequency
     and then adjust the level until a 12dB SINAD is produced. This level must
     be greater than 38dB above the level in step e.
k.   Repeat steps f through j for frequencies 836.0, 848.5, 869.1, 881.0, &
     893.5MHz.


TEST RESULTS:    The UUT meets the 38dB REJECTION RATIO.



PERFORMED BY: NAM NGUYEN                DATE:    10/26/05


APPLICANT:    VERTEX STANDARD CO., LTD.
   FCC ID:    K6620233X40
 REPORT #:    V\VERTEX\2091UT5\2091UT5TestReport.doc

                                                               Page 4 of 4



Document Created: 2005-11-09 15:51:05
Document Modified: 2005-11-09 15:51:05

© 2025 FCC.report