VXR-9000 FM REPEATER OPERATING MANUAL
                                                                       Vertex Standard Co., Ltd.


                          FCC ID: K6610443250/IC ID: 511B-10443250




VXR-9000 FM REPEATER OPERATING MANUAL
                                          Vertex Standard Co., Ltd.


                                                                                              FCC ID: K6610443250/IC ID: 511B-10443250



                                                                                       INTRODUCTION




The VXR-9000 is commercial-grade 50-watt FM repeater designed to provide reliable two-way full-duplex commu-
nications over a wide range of environmental conditions.
Designed to mount in a standard 19-inch rack, the VXR-9000 is crafted using the latest computer-aided design and
manufacturing processes, to ensure a high level of reliability to users. Important channel frequency data is stored in
EEPROM, and is easily programmable by a Servicing Technician or Dealer using an IBM compatible personal com-
puter and the VPL-1 Programming Cable and CE60 Software.
Please take a few minutes to read this manual carefully. The information presented here will allow you to derive
maximum performance from your VXR-9000. After reading it, keep this manual handy for quick reference, in case
questions arise later on.
Important Note: Internal service work, programming, and accessory installations should only be performed by your
authorized Vertex Standard Dealer. Dangerous conditions and/or possibly illegal operation may result from im-
proper setup, programming, or internal modifications.




                                          SAFETY/WARNING INFORMATION
   The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a
   separation distance of at least 1.98m
                                   74cm from all persons during normal operation and must not exceed an
   antenna gain of 0 dBd. This device must be restricted to work related operations in an Occupational/Con-
   trolled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. The antenna(s)
   used with this device must satisfy the antenna co-location requirements of 47 C.F.R. 1.1307(b)(3).

                                                      NOTICE!
    Do not modify this repeater for any reason.
     Refer service of this repeater to qualified technicians only.
    When the repeater become abnormal, such as the overheating, smoke smell of burning, etc., turn the main
     power switch off and disconnect the Main Power Source connector from the rear of the VXR-9000 imme-
     diately. Also disconnect any backup power source you may have connected to the rear of the VXR-9000.
    Do not place any combustible material near the repeater.
    Do not spray any liquid over the repeater.
    Ensure that the power and antenna connections are securely made, using cables with excess capacity for
     the power being utilized.


VXR-9000 FM REPEATER OPERATING MANUAL                                                                                        1
                                                                                                              Vertex Standard Co., Ltd.


                                                                                                  FCC ID: K6610443250/IC ID: 511B-10443250



FRONT PANEL CONTROLS & CONNECTORS




 POWER (O/I) Switch                                         TX Indicator
    This is the main power switch for the repeater.            This LED glows red when the repeater is transmit-
                                                               ting.
 Power Indicator (MAIN)
    This LED glows green when the main power source          Numeric Display
    is used.                                                   This display consists of two 7-segment LEDs, indi-
                                                               cating the channel number during normal opera-
 Power Indicator (BACKUP)                                     tion. If an abnormal condition arises, an error code
    This LED glows red when the backup power source            will be displayed:
    is used.
                                                                DISPLAY          DESCRIPTION
                                                                01 - 32          Channel Number
 MIC Jack                                                      PC               Clone Active
    Connect the microphone plug to this jack. This jack         UL               PLL Unlock
    is also used for writing and reading channel fre-           HI               High temperature in PA Unit
    quency or other configurations via the COM Port of          SC               Scan Active
    the PC on which the clone editor (CE60) is running.         LC               Front Panel Keys are Locked
                                                                E1               PTT key is Disabled
 Programmable Function (PF) Key                                E2               Cooling Fan is Disabled
    Six pushbuttons on the front panel are program-             E5               Low Voltage in Backup Battery
    mable function (PF) keys, each with an orange in-           E7               PA Unit Abnormality
    dicator inside. Each key can be programmed with             E3, E4, E6, E9   Contact your Dealer
    two functions, one for a “long” press and one for a
    “momentary” press. The PF key functions may be             BUSY Indicator
    customized, via programming by your VERTEX                 This LED glows green when the receiving channel
    STANDARD dealer, to meet your communications               is busy.
    network requirements. Note that some functions
    may require the purchase of optional internal ac-          Speaker
    cessories. The possible PF key features and func-          The internal speaker is located here.
    tions are explained on the pages to follow.

 VOL Knob
    This control knob adjusts the output level of the
    front speaker and external speaker jack on the back
    panel.




2                                                         VXR-9000 FM REPEATER OPERATING MANUAL
                                                                                                                  Vertex Standard Co., Ltd.


                                                                                                                   FCC ID: K6610443250/IC ID: 511B-10443250



                         PROGRAMMABLE FUNCTION (PF) KEY DETAILS
                        PF-1 KEY             PF-2 KEY             PF-3 KEY             PF-4 KEY             PF-5 KEY              PF-6 KEY
      FUNCTION
                      PRESS PRESS & HOLD   PRESS PRESS & HOLD   PRESS PRESS & HOLD   PRESS PRESS & HOLD   PRESS PRESS & HOLD    PRESS PRESS & HOLD
 CH DOWN
 CH UP
 COMPANDER
 CTCSS/DCS ENC
 CTCSS/DCS DEC
 CW ID
 TWO TONE DEC
 CW ID SIGNAL
 CW MESSAGE 1
 CW MESSAGE 2
 CW MESSAGE 3
 CW MESSAGE 4
 CW MESSAGE 5
 CW MESSAGE 6
 CW MESSAGE 7
 CW MESSAGE 8
 DC POWER SAVE
 ENCRYPTION
 ENCRYPTION CODE
 KEY LOCK
 LOCAL PTT
 MONITOR
 MONITOR M
 MULTI TONE
 PANEL INDICATOR
 REMOTE
 REPEAT
 RESET
 SCAN
 SQUELCH
 TEST TONE
 TEST TONE M
 TOT
 TRANSMIT
 TX POWER MID
 TX POWER LOW

CH DOWN                                                                  CTCSS/DCS ENC
Press (or Press and hold in for one second) the PF key                   Press (or Press and hold in for one second) the PF key
assigned to “CH Down” to step to the next-lower oper-                    assigned to “CTCSS/DCS Enc” to turn the CTCSS/DCS
ating channel.                                                           Encoder “On” or “Off” (toggle).

CH UP                                                                    CTCSS/DCS DEC
Press (or Press and hold in for one second) the PF key                   Press (or Press and hold in for one second) the PF key
assigned to “CH Up” to step to the next-higher operat-                   assigned to “CTCSS/DCS Dec” to turn the CTCSS/DCS
ing channel.                                                             Decoder “On” or “Off” (toggle).

COMPANDER                                                                CW ID
Press (or Press and hold in for one second) the PF key                   Press (or Press and hold in for one second) the PF key
assigned to “Compander” to turn the Compander cir-                       assigned to “CW ID” to turn the CW Identifier feature
cuit “On” or “Off” (toggle). This function is only acti-                 “On” or “Off” (toggle).
vated on the “Narrow Channel Spread” of the “Base
                                                                         When the CW ID feature is set to “On,” your station’s
Transceiver” mode.
                                                                         callsign will be superimposed on the outbound signal,
The Compander IC contains two variable gain circuits                     in Morse Code, at the beginning of every transmission.
configured for compressing and expanding the dynamic                     Programming of the callsign is performed by your VER-
range of the repeater’s transmitted and received audio                   TEX STANDARD dealer.
signal. When you enable this function, the signal-to-
noise ratio can be improved by reducing the transmit-
ted audio dynamic range.

VXR-9000 FM REPEATER OPERATING MANUAL                                                                                                             3
                                                                                                                                   Vertex Standard Co., Ltd.


                                                                                                      FCC ID: K6610443250/IC ID: 511B-10443250



PROGRAMMABLE FUNCTION (PF) KEY DETAILS
TWO TONE DEC                                                  MONITOR
Press (or Press and hold in for one second) the PF key        Press (or Press and hold in for one second) the PF key
assigned to “Two Tone Dec” to turn the 2-Tone Decoder         assigned to “Monitor” to cancel CTCSS and DCS squelch
“On” or “Off” (toggle).                                       decoding, so as to enable reception of signals present on
                                                              the channel that do not contain a matching CTCSS tone
CW ID SINGLE                                                  or DCS code.
Press (or Press and hold in for one second) the PF key
assigned to “CW ID Single” to send the station callsign,      MONITOR M
via Morse Code, once. Programming of the callsign is          This function provides to “Monitor” to cancel CTCSS
performed by your VERTEX STANDARD dealer.                     and DCS squelch decoding, so long as the PF key as-
                                                              signed to “Monitor M” is pressed and held in.
CW MESSAGE 1 - CW MESSAGE 8
Press (or press and hold in for one second) the PF key        MULTI TONE
assigned to “CW Message 1 - 8” to send a pre-pro-             Press (or Press and hold in for one second) the PF key
grammed Morse Code message on the transmitted sig-            assigned to “Multi Tone” to switch the Tone Table be-
nal. Programming of the message(s) is performed by            tween “Main” and “Sub.”
your VERTEX STANDARD dealer.
                                                              PANEL INDICATOR
DC POWER SAVE                                                 Press (or Press and hold in for one second) the PF key
Press (or Press and hold in for one second) the PF key        assigned to “Panel Indicator” to turn the Front Panel’s
assigned to “DC Power Save” to turn the DC Power              Illumination “On” or “Off” (toggle).
Save feature “On” or “Off” (toggle).
When DC Power Save feature is set to “ON,” activate
                                                              REMOTE
                                                              Press (or Press and hold in for one second) the PF key
the various power save feature (determined from your
                                                              assigned to “Remote” to toggle the operating mode be-
VERTEX STANDARD dealer) while the repeater oper-
                                                              tween the “Remote” mode and “Local” mode.
ates from the Backup Power Source.
                                                              When the “Remote” mode is selected, the repeater op-
ENCRYPTION                                                    erates according to the control instructions received
Press (or Press and hold in for one second) the PF key        from the external device (connected to the ACC jack on
assigned to “Encryption” to turn off the Optional En-         the rear panel). While in the “Local” mode, the repeater
cryption Unit temporarily.                                    operates from the front panel’s PF keys.

ENCRYPTION CODE                                               REPEAT
Press (or Press and hold in for one second) the PF key        Press (or Press and hold in for one second) the PF key
assigned to “Encryption Code” to select the Encryption        assigned to “Repeat” to toggle the operating mode be-
Code (determined from your VERTEX STANDARD                    tween the “Repeater” mode and “Base Transceiver”
dealer; require the FVP-35 Rolling Code Encryption            mode.
Unit).
                                                              For normal operation, set this key to the “Repeat” mode.
                                                              When the “Base Transceiver” mode is selected, you can
KEY LOCK                                                      speak into the microphone to use this repeater as a trans-
Press (or Press and hold in for one second) the PF key
                                                              ceiver.
assigned to “Key Lock” to lock the repeater’s front panel
keys (except “Key Lock” key); this feature can be en-
                                                              RESET
abled to prevent repeater settings from being disturbed.
                                                              Press (or Press and hold in for one second) the PF key
                                                              assigned to “Reset” to reset (same function as the
LOCAL PTT                                                     POWER switch “off” and “on”) the repeater.
Press (or Press and hold in for one second) the PF key
assigned to “Local PTT” to enable (“On”) or disable
(“Off”) operation using a PTT switch connected to the
front panel’s Microphone Jack.




4                                                           VXR-9000 FM REPEATER OPERATING MANUAL
                                                                                                                      Vertex Standard Co., Ltd.


                                                                                               FCC ID: K6610443250/IC ID: 511B-10443250



                          PROGRAMMABLE FUNCTION (PF) KEY DETAILS
SCAN                                                          TOT
Press (or Press and hold in for one second) the PF key        Press (or press and hold in one second) the PF key as-
assigned to “Scan” to start scanning. To stop scanning,       signed to “TOT” to turn the Time-Out Timer feature
press (or Press and hold in for one second) this key again.   “On” or “Off” (toggle).
The scanning feature is used to monitor multiple chan-        When the TOT feature is set to “On,” the repeater will
nels programmed into the repeater.                            return to the “Receive” mode automatically after a pre-
                                                              set time of continuous transmission (determined via
This function is only activated on the “Base Trans-
                                                              programming by your VERTEX STANDARD dealer).
ceiver” mode.

SQUELCH                                                       TRANSMIT
                                                              Press (or Press and hold in for one second) the PF key
Press (or Press and hold in for one second) the PF key
                                                              assigned to “Transmit” to enable (“On”) or disable
assigned to “Squelch” to override the Squelch action
                                                              (“Off”) the transmission of the VXR-9000.
(CTCSS, DCS, and Noise Squelch), so as to hear any sig-
nal present on the operating channel.
                                                              TX POWER MID
                                                              Press (or Press and hold in one second) the PF key as-
TEST TONE
                                                              signed to “TX Power Mid”to set the transmitter power
Press (or Press and hold in for one second) the PF key
                                                              to the “Mid” level.
assigned to “Test Tone” to generate the Test Tone Signal,
as programmed by your VERTEX STANDARD dealer.                 Press (or press and hold in one second) this key again to
                                                              return to the “Original” power level (determined via
Press (or Press and hold in for one second) this key again
                                                              programming by your VERTEX STANDARD dealer).
to stop the generation of the Test Tone. This is a toggle
function.                                                     This function is ignored on the channel which is pro-
                                                              grammed to the transmitter power to the “Mid” or
Press (or Press and hold in for one second) this key while
                                                              “Low” level by your VERTEX STANDARD dealer.
press and holding the PTT switch to transmit the Test
Tone Signal, as programmed by your VERTEX STAN-
DARD dealer.
                                                              TX POWER LOW
                                                              Press (or Press and hold in one second) the PF key as-
                                                              signed to “TX Power Low”to set the transmitter power
TEST TONE M
                                                              to the “Low” level.
This function provides momentary generation of the
above-referenced Test Tone signal, so long as the PF key      Press (or press and hold in one second) this key again to
assigned to “Test Tone M” is pressed and held in.             return to “Original” power level (determined via pro-
                                                              gramming by your VERTEX STANDARD dealer).
Press this key while press and holding the PTT switch
to transmit the Test Tone Signal, as programmed by            This function is ignored on the channel which is pro-
your VERTEX STANDARD dealer.                                  grammed to the transmitter power to the “Low” level
                                                              by your VERTEX STANDARD dealer.




VXR-9000 FM REPEATER OPERATING MANUAL                                                                                         5
                                                                                                               Vertex Standard Co., Ltd.


                                                                                                                      FCC ID: K6610443250/IC ID: 511B-10443250



REAR PANEL CONNECTORS



                      TX                             BACKUP     BACKUP   MAIN      RX




                                                     INPUT
                                                     DC 13.6V

                                                                                                  GND
                                                              EXT
                                                                                  ACC




 Backup Power Source Terminals                                                  Main Power Source Connector
    If available, a backup 13.6 Volt power source, such                            The primary DC power source should be connected
    as a rechargeable battery, may be connected here.                              here. The power requirements are 13.6 V DC at 12
    When the Battery Charge switch (located on the PA                              Amps, continuous duty.
    Unit) is set to “ON,” a “trickle” charge current is
    present here while the repeater is operating from                            External Speaker Jack
    the “Main Power Source.”                                                       This 3.5-mm, 2-pin jack provides variable audio
                                                                                   output for an external speaker. The audio output
 Circuit Protection Fuse                                                          impedance at this jack is 4 to 16 Ohms, and the level
    Two 15-Amp blade fuses, for the “Main” and                                     varies according to the setting of the front panel's
    “Backup” power sources, are installed here.                                    VOL knob.

 RX Antenna Jack                                                                DSUB 25-pin Accessory Connector
    This BNC-type coaxial jack accepts the receiver in-                            This DB-25F connector allows the repeater to be re-
    put signal, for connection to the receiving antenna,                           mote-controlled by an external controller. Analog
    or the “RX” jack on the duplexer. The input imped-                             I/O signals, such as TX Audio In, Discriminator
    ance requirement is 50 Ohms.                                                   Output, RSSI, etc. are available. Moreover, the VXR-
                                                                                   9000 provides eight ports that can be programmed
 TX Antenna Jack                                                                  for various input or output signals, or for control
    This N-type coaxial jack provides the transmitter                              functions. Each port may be programmed as to its
    output signal, for connection to the transmitting                              function, its status (input or output), and its logic
    antenna, or the “TX” jack on the duplexer. The out-                            (for output ports only).
    put impedance requirement is 50 Ohms.




6                                                                   VXR-9000 FM REPEATER OPERATING MANUAL
                                                                                                                                      Vertex Standard Co., Ltd.


                                                                                                                     FCC ID: K6610443250/IC ID: 511B-10443250



                                                                DB-25 CONNECTOR PORT
The VXR-9000 repeater is provided with a 25-pin DB-           Pin 5: TX ATT
25F female connector for interconnections to                  This output is intended for controlling an external co-
accessories.Use a DB-25M 25-pin male connector to con-        axial switching relay. It is an open drain output which
nect accessories to the repeater. The pins on the acces-      can sink approx. 1.5 A when active. The delay time
sory connector are explained in detail as follows:            which is between the repeater cause to transmit mode
                                                              and this port switches to ground can be programmed
Pin 1: GND                                                    by your VERTEX STANDARD dealer.
Chassis ground for all logic levels and power supply
return.                                                       Pin 6: DISC OUT
                                                              [ANALOG OUTPUT] (WIDE-BAND: 0 ~ 3,000 HZ)
Pin 2: +13.6 V                                                Received signals with full system deviation produce
[POWER SUPPLY]                                                350 mVrms audio at this pin. The output impedance is
This pin provides 13.6 Volts, 2.0 A, DC from the repeater     600 Ohm, and is extracted before the de-emphasis and
supply. There is a internal 3 A fuse to prevent damage        squelch circuitry. Use shielded cable to connect to this
to the repeater.                                              pin, and connect the shield to GND.

Pin 3: TX AF IN                                               Pin 7: N.C.
[ANALOG TRANSMITTER INPUT] (VOICE BAND: 300 ~ 3,000 HZ)       No connection.
This pin is audio input. Input impedance is 600 Ohms.
This audio is injected before the splatter filter stage, so   Pin 8: RSSI
excess signal input levels are clipped.                       [ANALOG OUTPUT]
Use shielded cable to connect to this pin, and connect        A DC voltage proportional to the strength of the signal
the shield to GND.                                            currently being received (Receiver Signal Strength In-
                                                              dicator) is provided on this pin. This low impedance
Pin 4: TONE IN                                                output is generated by the receiver IF sub-system and
[TRANSMITTER INPUT] (SUB-AUDIBLE BAND: 5 ~ 250 HZ)            buffered by an internal op-amp. Typical voltages are
This pin is sub-audiable tone input. The input imped-         graphed as follows:
ance is 600 Ohms, and has a flat response characteristic          (DC V)
(repeater deviation is constant for a given signal level
                                                                 RSSI Output Voltage




                                                                                       2.5
over the frequency range of 5 ~ 250 Hz). Injecting too                                 2.0
high a voltage here causes over-deviation of CTCSS or
                                                                                       1.5
DCS, degrading performance.
                                                                                       1.0

Use shielded cable to connect to this pin, connecting the                              0.5
shield to GND.                                                                          0
                                                                                        –60   –70   –80       –90     –100     –110     –120 (dBm)
                                                                                                          Input Signal Level



                                                              Pin 9: COAX. SW
                                                              [LOGIC OUTPUT (ACTIVE LOW)]
                                                              This output is intended for controlling an external co-
                                                              axial switching relay. It is an open drain output which
                                                              can sink approx. 1.5 A when active. This signal only
                                                              switches if the repeater has been programmed for “SIM-
                                                              PLEX” mode. If programmed for “DUPLEX,” the signal
                                                              remains open (high impedance) at all time.



                  DB-25 PIN NUMBERING




VXR-9000 FM REPEATER OPERATING MANUAL                                                                                                                7
                                                                                                                                      Vertex Standard Co., Ltd.


                                                                                                        FCC ID: K6610443250/IC ID: 511B-10443250



DB-25 CONNECTOR PORT
Pin 10, 13, 15, 16, 17, 18, 19, 21:                            Pin 23: RXD HIGH
PROGRAMMABLE I/O “0” ~ ”7”        Pin             I/O Port     [DIGITAL OUTPUT FOR DATA COMMUNICATIONS]
The VXR-9000 provides eight ports (PIO)      10       6        (Max.: 5 kHz)
                                             13       7        This pin is an output for high speed receiving data sig-
that can be programmed for various
                                             15       4
input or output signals, or for control                        nals (typically 9600 bps), with the data being extracted
                                             16       3
functions. Each port may be pro-             17       2        immediately after the discriminator (prior to any de-
grammed as to its function, its status       18       1        emphasis).
(input or output), and its logic (for out-   19       0
put ports only).                             21       5        Pin 24: TXD LOW
                                                               [ANALOG INPUT FOR DATA COMMUNICATIONS]
Pin 11: NSQ DET                                                (300 ~ 3,000 Hz)
This is an open-collector, active-low output capable of        This pin is intended to be used as a low speed data
sinking about 10 mA. It indicates that the receiver            signal input to the repeater (typically 1200 bps). This
squelch is open. If the squelch control is properly set,       digital data signal is injected before the transmitter pre-
this indicates a carrier on the receiver channel.              emphasis and limiting stages, so excess signal input
                                                               levels are clipped.
Pin 12: EXT PTT
This input is internally pulled up to 5 VDC. When pulled       Pin 25: TXD HIGH
low by an external device, it keys the repeater trans-         [DIGITAL INPUT FOR THE DATA COMMUNICATIONS]
mitter while the repeater is operating in the “Remote”         (0 ~ 5 kHz)
mode. Avoid voltage in excess of 5 V on this pin, or           This pin is intended to be used as a high speed digital
internal damage to the microprocessor on the repeater          data signal input to the repeater (typically 9600 bps).
CNTL Unit may result.                                          This digital data signal is injected after the transmitter
                                                               splatter filter stage.
Pin 14, 20: GND
Chassis ground for all logic levels and power supply
return.

Pin 22: RXD LOW
[ANALOG OUTPUT FOR DATA COMMUNICATIONS]
(300 ~ 3,000 Hz)
This pin is an output for low speed receiving data sig-
nals (typically 1200 bps), with the data being extracted
after the de-emphasis and low pass filter stages.




8                                                            VXR-9000 FM REPEATER OPERATING MANUAL
                                                                                                                        Vertex Standard Co., Ltd.


                                                                                              FCC ID: K6610443250/IC ID: 511B-10443250



                                                                                         INSTALLATION
Antenna Considerations                                       Equipment Location
Repeater operation requires two antennas, one for re-        The VXR-9000 must be installed in a 19-inch Mounting
ceiving and one for transmitting, so that the receiving      Rack, which will allow for free air flow around the heat
antenna does not absorb energy from the transmitting         sink on the rear apron at all times. In warm climates,
antenna. There are a number of ways to do this, de-          the repeater should not be sealed in a small, closed room
pending on the TX/RX frequency separation, and on the        without air conditioning.
locations available for antenna mounting.
                                                             While the operating temperature range of the VXR-9000
Regardless of the above choice, it is of paramount im-       is quite broad, the best location is one in which the air
portance that the antenna(s) be mounted as high and in       temperature does not approach the extremes of the
the clear as possible, preferably within line-of-sight to    specified range, and one that does not change rapidly.
all repeater users. Furthermore, losses in the feedline(s)
                                                             Protect the VXR-9000 (Mounting Rack) from wind and
must be minimized, so the feedline(s) should be high
                                                             rain, and extremes in temperature or humidity that
quality, and as short as possible. If a long feedline is
                                                             may shorten the useful life of the equipment. Try to lo-
necessary, use coaxial “hardline” cable to reduce losses.
                                                             cate the VXR-9000 (Mounting Rack) in an environment
Repeater antennas should have an impedance of 50 Ω           that is also comfortable for service personnel, if pos-
at the operating frequency. When separate receive and        sible.
transmit antennas are used, high-Q narrow-band types
may serve to minimize interaction.


  NEVER TRANSMIT WITHOUT HAVING A
  TRANSMIT ANTENNA CONNECTED TO THE
  TX ANTENNA JACK OF THE REPEATER.




VXR-9000 FM REPEATER OPERATING MANUAL                                                                                        9
                                                                                                              Vertex Standard Co., Ltd.


                                                                                                                                                               FCC ID: K6610443250/IC ID: 511B-10443250



INSTALLATION
Power Supply                                                                                                            Backup Power Supply
Operation of the VXR-9000 requires a power source ca-                                                                   For uninterrupted operation during power failures, a
pable of providing at least 12 Amps continuously at                                                                     12-volt rechargeable type battery (55-Ah or more rec-
13.6 Volts DC. The FP-1023 (23 A) and FP-1030A (30 A)                                                                   ommended) may be connected to the BACKUP termi-
AC Power Supplies are available from your Vertex Stan-                                                                  nal posts on the rear panel. While the repeater is oper-
dard dealer to satisfy these requirements. Other well-                                                                  ating from the Main Power Source a slight charging
regulated power supplies may be used, as well, if they                                                                  current will maintain battery charge. In the event of an
meet the above voltage and current specifications.                                                                      unexpected interruption of the Main Power Source, the
                                                                                                                        automatic power control circuit will automatically
Use the DC power cable supplied with your repeater
                                                                                                                        switch the repeater to the backup battery, and opera-
for making power connections to the power supply.
                                                                                                                        tion will not be interrupted.
Connect the RED power cable lead to the POSITIVE (+)
power supply terminal, and connect the BLACK power                                                                      After prolonged operation from the battery, (Backup
cable lead to the NEGATIVE (–) power supply terminal.                                                                   Power Source), it should be disconnected from the re-
                                                                                                                        peater and recharged separately before re-connecting,
                                                                                                                        as the trickle charge is not sufficient for recharging a
                                                                                                                        completely discharged battery.
                                                                                                                        Never reapply the Main Power Source to the repeater
                                                                                                                        with a discharged battery connected as backup, as the
                                                                                                                        DC startup current can damage the repeater and bat-
                                                                                                                        tery.
                                                                                                                        While operating from a backup battery, the repeater
                                                                                                                        requires approximately 7 amperes at 12 Volts during
                                                                                                                        transmit.

                                                                                                                          Never short the “Backup Power Sorce” Terminals,
                                                                                                                          when the Battery Charge switch (located on the PA
                                                                   To RX Antenna


                                                                                            To TX Antenna




                                                                                                                          Unit) is set to “ON.”




                                     BACKUP     B ACK UP   MAIN                      RX


                                                                                                             TX




                                     INPUT
                                     DC 13.6V

                                                                                                                  GND
                                           EXT
                                                                                    ACC
                                                                                                                                                                       BLACK
                             BLACK




                                                                                                                                                              RED
         RED




                                                                                                                        Supplied DC Power Code




          Backup Battery
           (12 V, 55 Ah)


                                                                                          TYPICALLY SETUP

10                                                                                                           VXR-9000 FM REPEATER OPERATING MANUAL
                                                                                                                                                                               Vertex Standard Co., Ltd.


                                                                                                                FCC ID: K6610443250/IC ID: 511B-10443250



                                                                                          ACCESSORIS & OPTION
Supplied Accessories                                                               Optional Accessories
DC Power Cord (T9023499) ............................................          1   FIF-9      Inline Interface Box
15-A Blade Fuse (Q0000075) ...........................................         1   FVP-25     Encryption Unit
Knob Cap (RA0506900) ...................................................       6   FVP-35     Rolling Code Encryption Unit
Name Plate (RA0508500) ................................................        1   MD-11A8J   Desktop Microphone
Operating Manual ...........................................................   1   MH-25A8J   Hand Microphone




VXR-9000 FM REPEATER OPERATING MANUAL                                                                                                        11
                                                                                                                                Vertex Standard Co., Ltd.


                                                                                      FCC ID: K6610443250/IC ID: 511B-10443250



SPECIFICATIONS
General
Frequency Range:                      Type C : 148 - 174 MHz
Number of channel:                    32
PLL Step:                             2.5 kHz/5 kHz/6.25 kHz
Operating Voltage:                    13.6V DC ±10 %
Current Drain:                        30A Maximum
Frequency Stability:                  1.5 ppm
                                      1.0 ppm (30min after wake up)
Operating Temperature Range:          –22 °F to +140 °F (–30 °C to +60 °C)
Dimensions (W x H x D):               19 x 3-1/2 x 13-1/2 inch (483 x 88 x 343 mm)
Weight (Approx.):                     20 kg


Receiver
Antenna Impedance:                    50 ohm
Antenna Connector:                    Type-BNC
Receiver Type:                        Double-Conversion Superheterodyne
Sensitivity:                          0.25 µV (12dB SINAD)
Selectivity:                          85 dB (Wide), 75 dB (Narrow)
Intermodulation:                      82 dB (Wide), 78 dB (Narrow)
Image Rejection:                      90 dB
Squelch Threshold:                    –5 dBµ
Audio Output:                         4 W @4 ohm
Audio Distortion:                     <3%
Hum and Noise:                        > 55 dB (Wide), > 50 dB (Narrow)
Audio Frequency Response:             De-emphasis : 6 dB/oct (From 300 Hz to 3 kHz)
Conducted Spurious:                  < –80 dBm


Transmitter
RF Output Power:                      100/75/50 W (High/Mid/Low)
Antenna Impedance:                    50 ohm
Antenna Connector:                    Type-N
Modulation Type:                      16K0F3E/11K0F3E
System Deviation:                     ±5.0 kHz (Wide), ±2.5 kHz (Narrow)
Hum and Noise:                        > 50 dB (Wide), > 45 dB (Narrow)
Microphone Sensitivity:               5 mV
Audio Frequency Response:             Pre-emphasis : 6dB/oct (From 300 Hz to 3 kHz)
Spurious Emission:                    70dB below carrier
Audio Distortion:                     3.0 % @1 kHz
Microphone Impedance:                 600 ohm

Specifications subject to change without notice or obligation.




12                                                         VXR-9000 FM REPEATER OPERATING MANUAL
                                                                                                      Vertex Standard Co., Ltd.


                                                                                      FCC ID: K6610443250/IC ID: 511B-10443250




           Part 15.21: Changes or modifications to this device not expressly ap-
           proved by Vertex Standard could void the user’s authorization to operate
           this device.


VXR-9000 FM REPEATER OPERATING MANUAL
                                                                                                      Vertex Standard Co., Ltd.


                                              FCC ID: K6610443250/IC ID: 511B-10443250




Copyright 2005              No portion of this manual may be
VERTEX STANDARD CO., LTD.   reproduced without the permission of
All rights reserved.        VERTEX STANDARD CO., LTD.

0504s-BE                                        Printed in Japan




                                                              Vertex Standard Co., Ltd.



Document Created: 2005-06-01 21:06:07
Document Modified: 2005-06-01 21:06:07

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC