Operating Manual-5

FCC ID: K6603770X30

Users Manual

Download: PDF
FCCID_3744317

                                          Transmitter Operation
                                Time-Out Timer
Most often used on FM, the transmitter’s Time-Out Timer (TOT) feature disables the
transmitter after a user-defined period of transmission. This feature may be useful in pre-
venting a “stuck microphone” (accidental closure of the PTT switch) from causing inter-
ference to other users, and it will also force you to keep your transmission short, thereby
conserving battery power.
To activate the Time-Out Timer:
1. Press and hold in the     key for one second to enter the Menu mode.
2. Rotate the       knob to recall Menu #49 (TOT TIME).
3. The default setting for this feature is “off.” Rotate the     knob to set a new time-
   out setting (from 1 minute to 20 minutes).
4. When you have made your selection, press and hold in the        key for one second to
   save the new setting and exit to normal operation.

                        WeatherFax Monitoring
Monitoring of HF WeatherFax broadcasts is easily accomplished using the FT-818.
1. Before proceeding, be certain that the WeatherFax demodulator is properly connected
   to Pins 5 (DATA OUT 1200bps) and 2 (GND) of the rear panel DATA jack.
2. Set the transceiver to the VFO mode, and set the operating mode to “DIG,” setting
   Menu #26 to PSK31-U, as described previously.
3. Now, select the operating frequency of the station transmitting the WeatherFax broad-
   cast. Note that, in the USB mode, the frequency you should program onto the display
   is typically 1.90 kHz below the station’s “assigned” frequency. Thus for a WeatherFax
   station assigned to 8.682.0 MHz, tune to 8.680.1 MHz.
4. When the WeatherFax broadcast begins, no further operator intervention should be
   needed from the transceiver standpoint. The audio level from the DATA jack on the
   rear of the transceiver is fixed, and cannot be adjusted.
Fine adjustments in the gray-scale and the frame alignment are accomplished using the
computer and software connected to your WeatherFax demodulator.




FT-818 Operating Manual                                                                41


 Memory Operation
                                QMB Channel
QMB Channel Storage
1. Tune in the desired frequency and set the operating mode and bandwidth. If this is an
   FM channel, set up any required CTCSS/DCS and repeater shift configurations.
2. Press and hold in the       key until a double “beep” is heard. The second beep pro-
   vides audible confirmation that the data has been stored into the QMB memory.
Pressing the     (A/B) key momentarily while in Operating Function Row 3 [STO,
          ]
RCL, PMS will also store a frequency into the QMB register.

QMB Channel Recall
1. Press the     key momentarily, then rotate the        knob, as needed, until Operating
   Function Row 3 [STO, RCL, PMS] appears on the display.
2. Press the       (RCL) key momentarily to recall the QMB memory. “QMB” will appear
   at the upper right corner on the LCD.
3. Press the       (RCL) key once more to return to the previous frequency (either a VFO
   frequency or a Memory channel).
If you move the         knob or         knob while in the QMB mode, you can change
frequencies as if you were in a “VFO” mode. You also can change operating mode by
pressing the            or            key. When this is done, the “MTQMB” will appear
in the display, where “MT” represents “Memory Tuning.” Press the           (RCL) key
once more to return to the originally-stored QMB frequency.




42                                                      FT-818 Operating Manual


                                                 Memory Operation
Memory Operation on “Regular” Memory Channels
Normal Memory Storage
1. Tune in the desired frequency, and set the operating mode and bandwidth. If this is an
   FM channel, set up any required CTCSS/DCS and repeater shift configurations. Stan-
   dard (default) repeater shifts do not require you to utilize the “split” frequency memo-
   ry technique, described later.
2. Press the     key momentarily, then rotate the          knob, as needed, until Operating
   Function Row 2 [MW, MC, TAG] appears on the display.
3. Press the       (MW) key momentarily to enter the “Memory Check” mode, which is
   used to find an unused memory channel. The frequency stored (if any) on the current
   memory channel will be shown in the display.
4. Rotate the        knob to select the channel number on which you wish to store the
   current frequency data.
5. Press and hold in the       (MW) key for one second until you hear a double beep; the
   second beep confirms that the frequency information was successfully stored.

Split-Frequency Memory Storage
You can also store “Split” frequencies, such as when operating on a repeater system not uti-
lizing a “standard” offset. This procedure may also be used for DX work on 7 MHz SSB,
etc.
1. In the VFO mode, set the desired Receive frequency and mode.
2. Press the     key momentarily, then rotate the       knob, as needed, until Operating
   Function Row 2 [MW, MC, TAG] appears on the display.
3. Press the      (MW) key momentarily to enter the “Memory Check” mode, which is
   used to find an unused memory channel. The frequency stored (if any) on the current
   memory channel will be shown in the display.
4. Rotate the       knob to select the channel on which you wish to store the receive fre-
   quency data.
5. Press and hold in the        (MW) key for one second until you hear a double beep,
   which confirms that the Receive frequency data is now stored.
6. Now, set the desired Transmit frequency and mode on the VFO.
7. Press the      (MW) key momentarily; do not rotate the        knob!
8. While the “memory channel number” is blinking, press and hold in the PTT switch;
   while holding it in, press and hold in the     (MW) key for one second. The double
   “beep” will confirm that independent Transmit frequency data is now stored. You may
   now release the PTT switch.
In step 8 above, pressing the PTT switch does not activate the transmitter. It simply
sends a signal to the microprocessor that an independent Transmit frequency is being
stored on the same channel as a previously-stored Receive frequency.
FT-818 Operating Manual                                                                 43


 Memory Operation
Memory Channel Recall
1. If you currently are in the VFO tuning mode, press the           key once to enter the
   “Memory” mode (a memory channel number “M-nnn” will appear on the display in
   she space previously occupied by “VFOa” or “VFOb”).
2. To select another memory channel, turn the          knob.
3. When your memory channels are partitioned into Memory
   Groups via Menu #34, it is easy to change Memory Groups;
                                                                      Memory Group “OFF”
   press the        knob momentarily (a Group Number (“a”
   ~ “j”) will blink), then turn the        knob to step through
   the channels until you enter another. You may now press the
          knob once more to restrict memory channel access to
   the newly-selected Group.                                          Memory Group “ON”

4. Once you are operating on a memory channel, you may tune off of the original-
   ly-memorized frequency (as though you were in the VFO mode). Just rotate the
          knob; the “Memory Channel Number” will be replaced by one which indicates
   “MTUNE,” indicating that you have now shifted into the “Memory Tuning” mode.
   When operating the Memory Tuning mode, if you find another frequency you wish to
   store into another memory channel, just press the        (MW) key momentarily, select
   a new memory channel via the           knob, then press and hold in the     (MW) key
   until you hear the double beep.
5. To exit the Memory Tuning mode, press the          key as follows:
    One touch of the         key returns you to the original memory frequency.
    A second touch of the         key will cause you to exit the Memory mode and return
       to the VFO mode (the memory channel number will be replaced by “VFOa” or
       “VFOb”).
When operating on a “Split” frequency memory, a special “       ” indication will appear
on the LCD.




44                                                      FT-818 Operating Manual


                                                 Memory Operation
Masking Memory
Frequency data stored on a memory channel can be deleted, if desired, from any memory
channel except channel “1.” The deletion process is not a “hard” erasure, so if you erase a
channel by mistake using this procedure, the memory channel contents can be recovered.
1. Press the     key momentarily, then rotate the      knob, as needed, until Operating
   Function Row 2 [MW, MC, TAG] appears on the display.
2. Press the      (MW) key momentarily, then rotate the        knob to select the memo-
   ry channel to be deleted.
3. Press the      (MC) key momentarily. The frequency display field on the LCD will go
   blank, and the memory channel number will blink.
4. Wait about three seconds; when the memory channel number stops blinking, the data
   will now be “masked” and will not be available for operation.
5. To restore the masked frequency data, repeat the above steps. However, if you store
   new frequency information on a channel containing masked data, the masked data will
   be over-written and lost.
6. Memory Channel 1 is used for Priority operation, and frequency information may
   only be over-written (not masked) on this channel.




FT-818 Operating Manual                                                                45


 Memory Operation
 Memory Operation on “HOME” Channel Memories
Four Special one-touch “Home” channels are available, for special frequencies you use
often. Either “simplex” or “split” frequency/mode data may be stored in the “Home”
channel locations. Special “Home” channels are available for HF (any frequency between
1.8 and 29.7 MHz), 50 MHz, 144 MHz, and 430 MHz.
These memories may prove particularly useful for monitoring propagation beacons, pro-
viding one-touch recall of the beacon frequency for a quick check of band conditions.
HOME Channel Storage
1. Tune the desired frequency, and set the operating mode. If this is an FM channel, set
   up any required CTCSS/DCS and repeater shift configurations.
2. Press the     key momentarily, then rotate the        knob, as needed, until Operating
   Function Row 2 [MW, MC, TAG] appears on the display.
3. Press the      (MW) key momentarily to enter the “Memory Check” mode.
4. Press and hold in the       key for one second. This stores the frequency data into the
   “Home” channel location. As usual, you will hear a double beep to confirm the suc-
   cessful storage of the frequency data.
5. If you wish to store a “Split” frequency pair into the “Home” channel, store the Re-
   ceive frequency in steps 1 ~ 4 above. Now set the desired Transmit frequency.
6. Once more, press the        (MW) key momentarily.
7. Press and hold in the microphone’s PTT switch; while holding the PTT switch, again
   press and hold the        key for one second. This stores the transmit frequency data
   into the “Home” channel location.

HOME Channel Recall
1. Press the      key momentarily to recall the Home Channel on the band group where
   you currently are operating (HF, 50 MHz, 144 MHz, or 430 MHz). The “HOME” indi-
   cation will appear on the display.
2. Press the      key once more to return to the previously-used frequency (either a VFO
   frequency or a memory channel).




46                                                       FT-818 Operating Manual


                                                  Memory Operation
                             Labeling Memories
You may wish to append an alpha-numeric “Tag” (label) to a memory or memories, to aid
in recollection of the channel’s intended use (such as a club name, etc.). This is easily ac-
complished using the Menu mode.
1. Recall the memory channel onto which you wish to appended a label.
2. Press and hold in the    key for one second to enter the Menu mode.
3. Rotate the       knob to recall Menu #35 (MEM TAG).
4. Press the       knob to enable the programming of the label.
5. Rotate the        knob to select the first character (number, letter, or symbol) in the
   name you with to store, then rotate the       knob clockwise to move to the next char-
   acter.
6. Again rotate the        knob to select the next number, letter, or symbol, then rotate
   the       knob clockwise to move to the next character’s slot.
7. Repeat step 6 as many times as necessary to complete the name tag for the memory,
   then press and hold in the      key for one second to save the A/N (Alpha-Numeric)
   name entry and exit to normal operation.
During Memory operation, press the         key momentarily, then
rotate the       knob, as needed, until Operating Function Row
2 [MW, MC, TAG] appears on the display. Press the         (TAG)
key momentarily to activate the alpha-numeric Tag. Repeatedly          “Frequency” Display
pressing this key will toggle operation between “Frequency” dis-
play and “Tag” display.
You can recall Menu #35 (MEM TAG) instantly by pressing and
holding in the    (TAG) key for one second.                               “Tag” Display




FT-818 Operating Manual                                                                   47


 Spectrum Scope Monitor Operation
Note: This operation does not function in the FM Broadcast frequencies.
The Spectrum Scope Monitor allows viewing of operating activ-
ity on 5 channels above and 5 channels below the current operat-
ing channel in the VFO mode. When the Spectrum Scope Mon-
itor is activated, the display indicates the relative signal strength
on channels immediately adjacent to the current operating frequency.
Two basic operating modes for Spectrum Scope are available:
CONT: In this mode, the transceiver sweeps the current band repeatedly until the Spec-
      trum Scope is turned off.
CHK: In this mode, the transceiver sweeps the current band one cycle every 10 seconds.

Setting the Spectrum Scope Mode
1.   Press and hold in the    key for one second to enter the Menu mode
2.   Rotate the       knob to select Menu #43 (SCOPE).
3.   Rotate the       knob to select the desired sweep mode (see above).
4.   When you have made your selection, press and hold in the       key for one second to
     save the new setting and exit to normal operation.

Activate the Spectrum Scope
1. Set the transceiver to the VFO mode in the desired band.
2. Press the     key momentarily, then rotate the       knob, as needed, until Operating
   Function Row 6 [SSM, SCH, ART] appears on the display.
3. Press the      (SSM) key momentarily to engage the Spectrum Scope.
4. When the Spectrum Scope is in operation, the relative signal strength of stations on
   channels immediately adjacent to the current frequency will be indicated on the dis-
   play.
5. To disable the Spectrum Scope, press the       (SSM) key once more.
The receiver’s audio output and S-meter are disabled when using the Spectrum Scope.




48                                                       FT-818 Operating Manual


                                Smart Search™ Operation
Note: This operation does not function in the FM Broadcast frequencies.
The Smart SearchTM feature automatically stores frequencies where activity is encoun-
tered on the current band. When Smart SearchTM is engaged, the transceiver quickly
searches above your current frequency, storing active frequencies as it goes (without
stopping on them even momentarily). These frequencies are stored in a special Smart
SearchTM memory bank, consisting of 50 memories. This feature available on the FM and
AM modes.
The Smart Search™ feature is especially helpful when traveling, as you can instantly
store active FM repeater frequencies without having to look up the frequencies in a refer-
ence book.
1. Set the            knob to the point where background noise is silenced. A typical set-
   ting, for effective Smart SearchTM operation, will be at 12 o’clock or slightly clock-
   wise from this position.
2. Set the VFO to the frequency on which you wish to begin the search (the Smart
   SearchTM feature is available on the VFO mode only).
3. Press the     key momentarily, then rotate the         knob, as needed, until Operating
   Function Row 6 [SSM, SCH, ART] appears on the display.
4. Now press the         (SCH) key momentarily; the blinking “SRCH” indicator will ap-
   pear on the LCD, and the transceiver will sweep upward on the current band, loading
   channels on which it encounters a signal strong enough to open the squelch.
5. All channels where activity is present (up to 50 channels) will be loaded into the
   Smart SearchTM memories. Whether or not all 50 memories are filled, the search will
   stop after one sweep.
6. Now you can turn the          knob to select from the just-stored Smart SearchTM mem-
   ories. If you find frequencies you wish to store into a “regular” memory, just follow
   the procedures described previously; just don’t press the       (SCH) key while storing
   these memories, because this will disable Smart Search™ operation (see step 7).
7. To disable Smart SearchTM operation, press the       (SCH) key momentarily.
The Smart Search™ memories are so-called “soft” memories; they will be lost if you
initiate a new Smart SearchTM sweep of the band.




FT-818 Operating Manual                                                               49


 Scanning Operation
Note: This operation does not function in the FM Broadcast frequencies.
This transceiver contains a wide variety of scanning capabilities. Whether you are in the
VFO mode or one of the memory modes, scanning operation is fundamentally identical in
all configurations, but with the following differences:
      In the VFO mode, scanning causes the transceiver to sweep up or down the band,
       pausing or halting on any signal encountered;
      In the Memory mode, the scanner will scan the programmed memories, and can be
       instructed to skip certain memories during scanning;
      In the Programmable Memory Scan (PMS) mode, the scanner will scan the band
       within user-programmed frequency limits.

Scanning Operation
1. Set the            knob to the point where background noise is silenced. A typical set-
   ting, for effective scanning operation, will be at 12 o’clock or slightly clockwise from
   this position.
2. Set the transceiver into the operating configuration in which you wish to scan (VFO or
   Memory; PMS will be described later).
8. Press the      key momentarily, then rotate the         knob, as needed, until Operating
   Function Row [SCN, PRI, DW].
3. Press the        (SCN) key momentarily to start upward scan (toward higher frequen-
   cies or higher memory channel numbers).
4. Rotate the          knob or       knob counterclockwise to toggle the scanning direc-
   tion downward.
5. The scanner will now cause the transceiver to increment in the chosen direction until a
   signal is detected. When a signal is encountered which opens the Squelch, In the FM/
   AM modes, the scanner will pause until the signal disappears (at the end of the other
   station’s transmission), at which point scanning will resume. While the transceiv-
   er is in the “Pause” condition, the decimal points in the frequency display area will
   blink. See “Scan-Resume Choices” on the next page for details of how to customize
   the resumption of scanning, In the SSB/CW modes, the scanner will slow down (but
   doesn’t stop).
6. Press the PTT switch on the microphone to cancel scanning.
You may also press and hold in either the [UP] or [DWN] key on the microphone for
1/2 second to initiate upward or downward scanning, respectively, if Menu #37 (MIC
SCAN) is set to “ON”.




50                                                       FT-818 Operating Manual