                                SD—R400—BQ
                      Microwave RTE Sensor
                                     Manual




Features:
e 12~24 VDC Operating voltage               Universally compatible, install the sensor
e —24,150GHz Microwave Doppler technology   above automatic doors for no—touch
e 10ft (3m) Sensing range, adjustable       ingress/egress
* Adjustable relay output time, 1~33 s      More consistent detection in large areas
e Small size allows for a wide range        and over a wide range of temperatures
  of applications                           Indoor use only



SECO—LARM®_SL]T                                                                        @


ENFORCER Microwave RTE Sensor
Introduction:
The ENFORCER Microwave RTE Sensor is a compact motion sensor with an adjustable output
timer that can be connected to an access control keypad, gate opener, and can be used to trigger
any device with an egress input.

Parts List:
1x Microwave sensor                            2x Mounting screws                      1x Mounting template
1x 5—Pin connector cable                       1x Manual

Specifications:
 Operating voltage                                                    12~24 VDC
 Current         Standby                                   23mA@12VDC / 14mA@24VDC
 draw            Active                                    39mA@12VDC / 21mA@24VDC
 Sensor frequency                                                     24.150GHz
 Sensor range                                                3‘~10‘ (0.9~3m), adjustable
 Sensor          Vertical                                               0°~90°
 angle           Horizontal                                              +30°
 Detection       Front/back                                            20°~30°
 angle           Left/right                                            60°~70°
 Min. detection speed                                                    bemi/s
 Output relay                                    2A@30VDC (0.5A@125VAC) Dry relay, NO/NC/COM
 Relay output time                                                      1~33 s
 Mounting height                                                    6‘~10‘ (1.8~3 m)
 Cable length                                                          8 (2.5m)
 LED Indicator                                                 Red on relay activation
 Case material                                              Black ABS and polycarbonate
 Operating temperature                                        ~4°~131° F (—20°~55° C)
 Dimensions                                                31/8"x23/s"x21/s" (80x60x54 mm)
 Weight                                                               2.5—0z (70g)


Overview:
               Front                                   Side                                 Front
             3%/"(BOmm)       ——>»I
                                      4              2/s" (GAmm)                       (cover removed)
                                                                                                     LED Indicator
   n


           ENFORCER®                   2518"
                                      {6Omm)


                  werl                                                        Microwave                  Connector
                                                                             emitter pad                 cable hole

                                                                                  SECO—LARM U.S.A., Inc.


                                                            ENFORCER Microwave RTE Sensor
Installation:
1. Find a suitable mounting location no more than 10ft (3m) high.
2. Apply the mounting template to the wall where the sensoris to be mounted.
3. Mark the locations for the screws, and drill one hole to the right of where it says "Insert connector here."
4.    Remove the cover as described in How to Remove the Cover Before Installation, see below.
     NOTE: Make sure not to touch the microwave emitter pad once the coveris removed
5.   Connect the 5—pin connector cable to the microwave sensor and feed the opposite end through the
     connector hole in the wall and complete wiring as necessary. See pg. 4 for Wiring Diagram.
6.    Secure the microwave sensor to the wall with both screws.
7.   Adjust the sensor‘s vertical angle and rotation as necessary.
     NOTE: Grip the sensor above and below the emitter pad. Do not pinch the sides as it may damage
     the trimpots.
8.   Adjust the sensor‘s range and relay‘s output time using the two trimpots, see Adjusting the Sensor Range
     and Relay Output Time on pg. 4, and replace the cover.

How to Remove the Cover Before Installation:
1.  Squeeze the sides of the cover and wedge a thin flat—head
   screwdriver into the gap between the cover and the sensor base.
2. Apply moderate upward pressure to pry the cover off and away
   from the sensor base.

NOTE: Take care to inset the screwdriver into the gap between the
cover and sensor base, and not into the recessed area of the base
just below.

How to Remove the Cover Once Installed:
1. Insert a screwdriver into the hole at the top of the sensor cover.
2. Apply moderate downward pressure to pry the cover off and
   away from the sensor base.
                                                                                           Side view

Detection Area:
Horizontal Area of Detection:
1.    The horizontal area of detection will
      change depending on the horizontal tilt
      angle of the sensor.
2.    Mounted 7ft (2.1m) tall at center 0°, the
      area of detection is 5ft (1.5m) wide and                                            2 is 1    00   i 152
      5ft (1.5m) deep.                                                                              Units: meter (m)

Vertical Area of Detection:
1.    The vertical area of detection will change
      depending on the verticaltilt angle of the               =
      sensor.                                                              0
2.    Mounted 7ft (2.1m) tall at center 0° with a
      45° vertical tilt, the area of detection extends
                                                             0°~90°
      to 6ft (1.8m).
SECO—LARM U.S.A., Inc.                                                                                            3


ENFORCER Microwave RTE Sensor
Wiring Diagram:               Ralay output
                                                                            Brown wire: +12~24 VDC
                                                                            Black wire: (—) Ground
                                time trimpot “’@                            Yellow wire: N.C.
                              Sensor range          3                       Green wire: COM
                                    trimpot ——>I\                           White wire: N.O.
Adjusting the Sensor Range and Relay Output Time:
1. To adjust the sensor‘s range, turn the trimpot countarclockwise            Olilput time      Segsor renge        To
     (decrease) or clookwise (increase). Min: 3ft (0.9m) / Max: 10ft (3m)




                                                                                                                    $
2.   To adjust the relayoutput time, tum the trimpot counterclockwise              ®
                          :    +                                                                                   Distance
     (d_eerease) or clockwise (increase}.                                      ¢        t        ¥       y
     Min: 1 second / Max: 33 seconds                                          Min.    Max.      Min.   Max.           >
Troubleshooting:
      .                                                 * Sensor poweris off.
 LED is off                                             «_ Check wiring and plug into power supply.
                                                        * Make sure door is in automatic mode.
 Dooris not reacting normally                           _ Check the output configuration of the sensor. Typical wiring for
                                                          the sensor‘s output is N.O.
                                                        * Sensor is disturbed when the doorcloses due to motion and
                                                          vibrations.
 The door opens and closes on its own                   * Make sure the sensor is properly secured.
                                                        * Adjust microwave emitter pad angle.
                                                        * Reduce detection area size.
 Door opens for no reason                               * Adjust the angle and range of sensor.
IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of this
product complies with all national, state, and local laws and codes related to locking and egress devices. SECO—LARM will
not beheld responsible for the use of this product in violation of any current laws or codes.
FCC COMPLIANCE STATEMENT                           FCC ID: K4ER4OOBQ
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user‘s
authority to operate the equipment.
 IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the
device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure
requirements and void user‘s authority to operate the device.
WARRANTY: This SECO—LARM product is warranted against defects in material and workmanship while used in normal
service for one (1) year from the date of sale to the original customer. SECO—LARM‘s obligation is limited to the repair or
replacement of anydefective part if the unit is retuned, fransportation prepaid, to SECO—LARM. This Warranty is void if
damage is caused by or aftibuted to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO—LARM determines that such equipment
is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of
SECO—LARM and the purchaser‘s exclusive remedy, shall be limited to the replacementor repair only, at SECO—LARM‘s
option. In no event shall SECO—LARM be liable for any special, collateral, incidental, or consequential personal or property
damage of any kind to the purchaser or anyone else.
 NOTICE: The SECO—LARM policy is one of confinual development and improvement. For that reason, SECO—LARM
 reserves the right to change specifications without nofice. SECO—LARM is also not responsible for misprints. All trademarks
 are the property of SECO—LARM U.S.A., Inc. or their respective owners. Copyright© 2018 SECO—LARM U.S.A., Inc. All
 rights reserved.
SECO—LARM® U.S.A., Inc.                                                                                         e
 16842 Millikan Avenue, Irvine, CA 92606                  Website: www.seco—larm.com                              z* Picant
Phone: (949) 261—2999 | (800) 662—0800                    Email: sales@seco—larm.com                   ML§0—2400—80.181120.docx
                                                                                        SECO—LARM U.S.A., Inc.
PS



Document Created: 2019-02-01 15:06:16
Document Modified: 2019-02-01 15:06:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC