Test Report

FCC ID: K4ER400BQ

Test Report

Download: PDF
FCCID_4158912

                                          FCC PART 15.249
                                              TEST REPORT
                                                             For

                        Superior Electronics Corporation
                  No. 10 Lane 31, Chongde St., Sinyi District, Taipei City, 110,Taiwan


                                           FCC ID: K4ER400BQ


            Report Type:                                Product Name:
            Original Report                             Microwave RTE Sensor



                 Report Number:           RGMA190104001-00


                      Report Date:        2019-01-22


                                          Jerry Zhang
                     Reviewed By:         EMC Manager
                                          Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:         No.69 Pulongcun, Puxinhu Industry Area,
                                          Tangxia, Dongguan, Guangdong, China
                                          Tel: +86-769-86858888
                                          Fax: +86-769-86858891
                                          www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government.
* This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RGMA190104001-00




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................5
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC§15.203 - ANTENNA REQUIREMENT..............................................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  ANTENNA CONNECTOR CONSTRUCTION ......................................................................................................................8
FCC §15.207 (A)– AC LINE CONDUCTED EMISSIONS .......................................................................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
  EUT SETUP ..................................................................................................................................................................9
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST PROCEDURE ......................................................................................................................................................10
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................10
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................10
  TEST DATA ................................................................................................................................................................11
FCC§15.205, §15.209&§15.249- RADIATED EMISSIONS ....................................................................................13
  APPLICABLE STANDARD ............................................................................................................................................13
  EUT SETUP ................................................................................................................................................................13
  TEST EQUIPMENT SETUP ............................................................................................................................................14
  TEST PROCEDURE ......................................................................................................................................................15
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................15
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................16
  TEST DATA ................................................................................................................................................................16
FCC §15.215(C) – 20 DB BANDWIDTH TESTING ................................................................................................23
  APPLICABLE STANDARD ............................................................................................................................................23
  TEST PROCEDURE ......................................................................................................................................................23
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................23
  TEST DATA ................................................................................................................................................................23




                                                                                                                                                            Page 2 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RGMA190104001-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                                EUT Name:      Microwave RTE Sensor
                                EUT Model:     SD-R400-BQ
                        Rated Input Voltage:   12-24VDC
                        External Dimension:    80mm(L)*60mm(W)*54mm(H)
                             Serial Number:    190104001
                        EUT Received Date:     2019.01.08


Objective
This type approval report is prepared on behalf of Superior Electronics Corporation in accordance with
Part 2-Subpart J, and Part 15-Subparts A and C of the Federal Communication Commissions rules.

The tests were performed in order to determine compliance with FCC Rules Part 15, Subpart C, and
section 15.203, 15.205, 15.207, 15.209 and 15.249 rules.


Related Submittal(s)/Grant(s)
N/A.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).


Measurement Uncertainty
               Parameter                                 Measurement Uncertainty
       Occupied Channel Bandwidth                                   ±5 %
                                            30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical
       Unwanted Emissions, radiated          200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical
                                                  1G~6GHz: 4.45 dB, 6G~26.5GHz: 5.23 dB
               Temperature                                          ±1℃
                 Humidity                                           ±5%
       DC and low frequency voltages                               ±0.4%
                Duty Cycle                                           1%
        AC Power Lines Conducted                          3.12 dB (150 kHz to 30 MHz)
                 Emission




                                                                                                Page 3 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RGMA190104001-00

Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier: CN0022.




                                                                                              Page 4 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RGMA190104001-00

SYSTEM TEST CONFIGURATION
Justification
The EUT was configured in operating mode for testing which was provided by the manufacturer.

The device operates on frequency: 24150 MHz


EUT Exercise Software
No software was used in test.


Equipment Modifications
No modifications were made to the EUT.


Local Support Equipment List and Details

        Manufacturer                    Description            Model                 Serial Number
           unknow                         adapter            2ABB018F                      /



Support Cable List and Details

 Cable Description     Shielding Type       Ferrite Core   Length(m)       From                  To
     power cable            No                      No         4           adapter              EUT




                                                                                               Page 5 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RGMA190104001-00

Block Diagram of Test Setup




                                                                      Page 6 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                 Report No.: RGMA190104001-00

SUMMARY OF TEST RESULTS

                FCC Rules                   Description of Test         Result

                  §15.203                  Antenna Requirement        Compliance

                 §15.207(a)                Conduction Emissions       Compliance

          15.205, §15.209, §15.249          Radiated Emissions        Compliance

                §15.215 (c)                  20 dB Bandwidth          Compliance




                                                                                    Page 7 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RGMA190104001-00

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
For intentional device, according to §15.203, an intentional radiator shall be designed to ensure that no
antenna other than that furnished by the responsible party shall be used.


Antenna Connector Construction
The EUT has one internal antenna arrangement, and the antenna gain is 2.15 dBi, fulfill the requirement of
this section. Please refer to the EUT photos.

Result: Compliant.




                                                                                                  Page 8 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RGMA190104001-00

FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207(a)


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main LISN with a 120 V/60 Hz AC power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                       IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                               Page 9 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RGMA190104001-00

Test Procedure

During the conducted emission test, the adapter was connected to the first LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

        Margin = Limit – Corrected Amplitude


Test Equipment List and Details

                                                                                     Calibration    Calibration
     Manufacturer             Description           Model        Serial Number
                                                                                        Date         Due Date
          R&S              EMI Test Receiver       ESCS 30         830245/006         2018-12-10    2019-12-10

        Unknown               Coaxial Cable       C-NJNJ-50         C-0200-01         2018-09-05    2019-09-05

          R&S                 Test Software         EMC32         Version8.53.0          N/A            N/A

          R&S              Two-line V-network      ENV 216           101614           2018-12-10    2019-12-10

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                     Page 10 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                                                Report No.: RGMA190104001-00

Test Data
     Environmental Conditions

                           Temperature:                 25.8 C
         Relative Humidity:                              54 %
                          ATM Pressure:                100.8 kPa

      The testing was performed by Lily Xie on 2019-01-15.

Test Mode: Transmitting

AC120V, 60 Hz, Line:


                           80

                           70
                                                                                                          Quasi-Peak Limit
                           60
                                                                                                             Average Limit
                           50
           Level in dBμ




                           40

                           30

                           20

                           10

                           0
                           150k       300   400 500      800 1M        2M     3M     4M 5M 6     8 10M          20M     30M
                                                                   Frequency in Hz



    Frequency                     QuasiPeak           Bandwidth               Corr.      Margin       Limit
                                                                     Line                                             Comment
      (MHz)                        (dBμV)               (kHz)                 (dB)        (dB)       (dBμV)
      0.162441                      37.9                9.000         L1       11.0       27.4           65.3         Compliance
      0.288307                      43.6                9.000         L1       10.2       17.0           60.6         Compliance
      0.558572                      20.6                9.000         L1       9.8        35.4           56.0         Compliance
      1.476605                      16.9                9.000         L1       9.8        39.1           56.0         Compliance
      3.491417                      21.0                9.000         L1       9.8        35.0           56.0         Compliance
      3.934683                      25.4                9.000         L1       9.8        30.6           56.0         Compliance

    Frequency                      Average            Bandwidth               Corr.      Margin       Limit
                                                                     Line                                             Comment
      (MHz)                        (dBμV)               (kHz)                 (dB)        (dB)       (dBμV)
      0.243884                       25.5               9.000         L1       10.3       26.5           52.0         Compliance
      0.292938                       32.2               9.000         L1       10.2       18.2           50.4         Compliance
      0.468757                       15.6               9.000         L1       9.9        30.9           46.5         Compliance
      1.190776                       13.1               9.000         L1       9.8        32.9           46.0         Compliance
      3.575883                       11.7               9.000         L1       9.8        34.3           46.0         Compliance
      3.934683                       13.2               9.000         L1       9.8        32.8           46.0         Compliance

                                                                                                                         Page 11 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RGMA190104001-00

AC120V, 60 Hz, Neutral:


                          80

                          70
                                                                                                        Quasi-Peak Limit
                          60
                                                                                                           Average Limit
                          50
           Level in dBμ




                          40

                          30

                          20

                          10

                          0
                          150k       300   400 500      800 1M       2M     3M     4M 5M 6     8 10M          20M     30M
                                                                 Frequency in Hz



    Frequency                    QuasiPeak           Bandwidth              Corr.      Margin       Limit
                                                                   Line                                             Comment
      (MHz)                       (dBμV)               (kHz)                (dB)        (dB)       (dBμV)
      0.161152                     36.0                9.000        N        11.0       29.4           65.4         Compliance
      0.163741                     35.3                9.000        N        11.0       29.9           65.2         Compliance
      0.167702                     37.2                9.000        N        10.9       27.9           65.1         Compliance
      0.184529                     33.5                9.000        N        10.7       30.8           64.3         Compliance
      0.204669                     33.3                9.000        N        10.6       30.1           63.4         Compliance
      0.290613                     42.5                9.000        N        10.2       18.0           60.5         Compliance

    Frequency                     Average            Bandwidth              Corr.      Margin       Limit
                                                                   Line                                             Comment
      (MHz)                       (dBμV)               (kHz)                (dB)        (dB)       (dBμV)
      0.150000                     26.5                9.000        N        11.2       29.5           56.0         Compliance
      0.295282                     34.3                9.000        N        10.2       16.1           50.4         Compliance
      0.450448                     15.3                9.000        N        9.9        31.6           46.9         Compliance
      0.750100                     15.0                9.000        N        9.8        31.0           46.0         Compliance
      1.310256                     13.4                9.000        N        9.8        32.6           46.0         Compliance
      3.903455                     13.0                9.000        N        9.8        33.0           46.0         Compliance




                                                                                                                       Page 12 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RGMA190104001-00

FCC§15.205, §15.209&§15.249- RADIATED EMISSIONS
Applicable Standard

As per FCC§15.249 (a), except as provided in paragraph (b) of this section, the field strength of emissions
from intentional radiators operated within these frequency bands shall comply with the following:


            Fundamental         Field strength of fundamental       Field strength of harmonics
             frequency                 (millivolts/meter)                (microvolts/meter)

            902–928 MHz                       50                                500

          2400–2483.5 MHz                     50                                500

           5725–5875 MHz                      50                                500

           24.0–24.25 GHz                    250                                2500


  As per FCC§15.249 (c), Field strength limits are specified at a distance of 3 meters.

 (d) Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated
  by at least 50 dB below the level of the fundamental or to the general radiated emission limits in §15.209,
  whichever is the lesser attenuation.


EUT Setup
Below 1 GHz:




                                                                                                  Page 13 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RGMA190104001-00

Above 1 GHz:




The radiated emission tests were performed in the 3 meters chamber, using the setup accordance with the
ANSI C63.10-2013. The specification used was the FCC 15.209/15.205 and FCC 15.249 limits.

According to C63.10, the above 26.5 GHz test result shall be extrapolated to the specified distance
using an extrapolation factor of 20dB/decade from 3m to 1 m
Distance extrapolation factor =20 log (specific distance [3m]/test distance [1m]) dB
Extrapolation result = Corrected Amplitude (dBμV/m) - distance extrapolation factor (9.54dB)

For above 40GHz, external harmonic mixers are utilized. The antenna is scanned around the entire
perimeter surface of the EUT, in both horizontal and vertical polarizations, at the distance of 0.5m from the
EUT. The Mixers and it`s RF cables is compose a system for calibration, the conversion factor was added
into the test Spectrum Analyzer in testing.


Test Equipment Setup
The system was investigated from 30 MHz to 100 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

               Frequency Range            RBW          Video B/W        IF B/W        Measurement
             30 MHz – 1000 MHz           120 kHz        300 kHz         120 kHz           QP
                                          1MHz           3 MHz             /              PK
                 Above 1 GHz
                                          1MHz            10 Hz            /              AV

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.



                                                                                                Page 14 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RGMA190104001-00

Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.



All data was recorded in the Quasi-peak detection mode from 30 MHz to 1GHz, peak and average
detection mode above 1 GHz.


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude




                                                                                            Page 15 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RGMA190104001-00

Test Equipment List and Details

                                                                        Serial      Calibration    Calibration
    Manufacturer           Description              Model
                                                                      Number           Date         Due Date
         R&S           EMI Test Receiver              ESCI             100224       2018-12-10     2019-12-10
    Sunol Sciences          Antenna                    JB3           A060611-1      2017-11-10     2020-11-10
          HP               Amplifier                 8447D          2727A05902      2018-09-05     2019-09-05
       Unknown           Coaxial Cable             C-NJNJ-50         C-0400-01      2018-09-05     2019-09-05
       Unknown           Coaxial Cable             C-NJNJ-50         C-0075-01      2018-09-05     2019-09-05
         R&S           Spectrum Analyzer            FSU 26             200256       2019-01-04     2020-01-04
         R&S           Spectrum Analyzer             8564E          3943A01781      2019-01-04     2020-01-04
       TDK RF            Horn Antenna              HRN-0118            130 084      2018-10-12     2021-10-12
      Ducommun                                                       1007726-01
                          Horn Antenna         ARH-4223-02                          2016-11-18     2019-11-18
     Technolagies                                                       1304
      Ducommun                                                       1007726-01
                          Horn Antenna         ARH-2823-02                          2016-11-18     2019-11-18
     Technolagies                                                       1302
        OML              Harmonic Mixer       WR19/M19HWD             U60313-1      2016-10-14     2019-10-14
        OML               Horn Antenna           M19RH                11648-01      2016-10-14     2019-10-14
        OML              Harmonic Mixer       WR12/M12HWD             E60120-1      2016-10-19     2019-10-19
        OML               Horn Antenna           M12RH                E60120-2      2016-10-19     2019-10-19
        OML              Harmonic Mixer       WR08/M08HWD             F60313-1      2016-10-24     2019-10-24
        OML               Horn Antenna           M08RH                F60313-2      2016-10-24     2019-10-24
                                              UFA147-1-2362-       64639 231029-
    MICRO-COAX            Coaxial Cable                                             2018-02-24     2019-02-28
                                                  100100                 001
        Mini              Pre-amplifier        ZVA-183-S+           5969001149      2018-09-05     2019-09-05
       Quinstar            Amplifier         QLW-18405536-JO        15964001001     2018-06-27     2019-06-27
        Farad             Test Software          EZ-EMC               V1.1.4.2         N/A            N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).

Test Data
     Environmental Conditions

              Temperature:           23.4~24.3 oC
         Relative Humidity:              43~58 %
            ATM Pressure:           100.3~100.8 kPa
    The testing was performed by Tyler Pan on 2019-01-15, 2019-01-16.




                                                                                                     Page 16 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RGMA190104001-00

Test Mode: Transmitting

1) 30MHz-1GHz:
Horizontal:




                   Receiver                     Correction     Cord.
   Frequency                                                                Limit        Margin
                   Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBuV/m)        (dB)
                   (dBuV)                        (dB/m)      (dBuV/m)
     30.0000        26.29           peak           1.72        28.01        40.00         11.99
    116.3300        30.05           peak          -5.13        24.92        43.50         18.58
    155.1300        31.59           peak          -5.87        25.72        43.50         17.78
    529.5500        27.99           peak           0.39        28.38        46.00         17.62
    581.9300        27.98           peak           1.02        29.00        46.00         17.00
    960.2300        12.73           peak          22.90        35.63        54.00         18.37




                                                                                         Page 17 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RGMA190104001-00

Vertical:




                   Receiver                     Correction     Cord.
   Frequency                                                                Limit        Margin
                   Reading        Detector       Factor        Amp.
     (MHz)                                                                (dBuV/m)        (dB)
                   (dBuV)                        (dB/m)      (dBuV/m)

     31.9400         29.02          peak             0.19     29.21         40.00         10.79
     50.3700         41.06           QP             -11.27    29.79         40.00         10.21
    155.1300         33.66          peak             -5.87    27.79         43.50         15.71
    361.7400         32.16          peak             -2.80    29.36         46.00         16.64
    703.1800         28.35          peak             3.11     31.46         46.00         14.54
    954.4100         37.78          peak             -3.31    34.47         46.00         11.53




                                                                                         Page 18 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RGMA190104001-00

2) 1GHz-40GHz
                   Receiver             Rx Antenna         Cable      Amplifier   Corrected
Frequency                                                                                       Limit    Margin
              Reading                Polar   Factor         loss       Gain       Amplitude
  (MHz)                 Detector                                                              (dBμV/m)    (dB)
              (dBμV)                 (H/V) (dB(1/m))       (dB)         (dB)      (dBμV/m)
 24150.00      83.51       PK          H      35.41        10.96       37.12         92.76     127.96    35.20
 24150.00      78.25      AV           H      35.41        10.96       37.12         87.50     107.96    20.46
 24150.00      100.50      PK          V      35.41        10.96       37.12        109.75     127.96    18.21
 24150.00      96.37      AV           V      35.41        10.96       37.12        105.62     107.96    2.34
 24000.00      42.54       PK          V      35.35        10.87       37.40         51.36     74.00     22.64
 24000.00      32.35      AV           V      35.35        10.87       37.40         41.17     54.00     12.83
 24250.00      42.51       PK          V      35.45        11.02       36.94         52.04     74.00     21.96
 24250.00      32.47      AV           V      35.45        11.02       36.94         42.00     54.00     12.00

40GHz-100GHz
                   Receiver               Rx Antenna           Corrected      Extrapolation
Frequency                                                                                       Limit    Margin
              Reading                  Polar      Factor       Amplitude          result
  (GHz)                 Detector                                                              (dBμV/m)    (dB)
              (dBμV)                   (H/V)    (dB(1/m))      (dBμV/m)        (dBμV/m)
  48.3*        31.29       PK            V        40.08          71.37            61.83         87.96     26.13
  48.3*        19.78      AV             V        40.08          59.86            50.32         67.96     17.64
  72.45*       32.14       PK            V        43.85          75.99            66.45         87.96     21.51
  72.45*       20.11      AV             V        43.85          63.96            54.42         67.96     13.54
  96.6*         30.1       PK            V        45.92          76.02            66.48         87.96     21.48
  96.6*        18.54      AV             V        45.92          64.46            54.92         67.96     13.04

Note:
 for the range 40-100GHz, the test performed at the distance 1.0 m.
*: Harmonics frequency.
Emissions under the noise floor have not recored.




                                                                                                    Page 19 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RGMA190104001-00

Test plots
Horizontal




                                                                    Fundamental




                                                                     Page 20 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RGMA190104001-00




Vertical




                                                                     Page 21 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RGMA190104001-00



                                                                     Fundamental




                                                                     Page 22 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RGMA190104001-00


FCC §15.215(c) – 20 dB BANDWIDTH TESTING
Applicable Standard
Intentional radiators operating under the alternative provisions to the general emission limits, as contained
in §§ 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that the 20 dB
bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section
under which the equipment operates, is contained within the frequency band designated in the rule section
under which the equipment is operated.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference
   level. Record the frequency difference as the emission bandwidth.
3. Repeat above procedures until all frequencies measured were complete.


Test Equipment List and Details

                                                                    Serial        Calibration    Calibration
     Manufacturer           Description               Model
                                                                   Number            Date         Due Date

          R&S           Spectrum Analyzer             FSU 26        200256         2019-01-04     2020-01-04
       Ducommun                                                   1007726-01
                           Horn Antenna         ARH-4223-02                        2016-11-18     2019-11-18
      Technolagies                                                   1304
                                                    UFA147-1-    64639 231029-
    MICRO-COAX             Coaxial Cable                                           2018-02-24     2019-02-28
                                                   2362-100100        001
                                                      QLW-
        Quinstar              Amplifier                          15964001001       2018-06-27     2019-06-27
                                                   18405536-JO

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:                 23.6 oC
         Relative Humidity:                 35 %
            ATM Pressure:                 100.3 kPa

    The testing was performed by Tyler Pan on 2019-01-16.

Test Result: Compliant.

Please refer to following tables and plots




                                                                                                     Page 23 of 24


Bay Area Compliance Laboratories Corp. (Dongguan)                     Report No.: RGMA190104001-00

Test Mode: Transmitting

                                  Frequency         20 dB Bandwidth
                                    (MHz)                (MHz)
                                    24150                 8.157




                                  ***** END OF REPORT *****




                                                                                       Page 24 of 24



Document Created: 2019-01-28 13:31:17
Document Modified: 2019-01-28 13:31:17