Test Report

FCC ID: K4ER100TBQ

Test Report

Download: PDF
FCCID_4130512

                                            FCC Part 15.231
                                             TEST REPORT
                                                               For

                       Superior Electronics Corporation
        No.10, Lane 31, Chongde St., Sinyi District, Taipei City 110, Taiwan (R.O.C.)



                                         FCC ID: K4ER100TBQ


                 Report Type:                                     Product Type:
                 Original Report                                  Wireless Help Button



                   Report Producer :              Kaylee Chiang


                     Report Number : RXZ181204009-00


                          Report Date : 2018-12-21


                          Reviewed By: Jerry Chang

                     Prepared By: Bay Area Compliance Laboratories Corp.(Taiwan)
                                         70, Lane 169, Sec. 2, Datong Road, Xizhi Dist.,
                                         New Taipei City 22183, Taiwan, R.O.C.
                                         Tel: +886 (2) 2647 6898
                                         Fax: +886 (2) 2647 6895
                                         www.bacl.com.tw




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 1 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00



                                                 Revision History
                                                                                                                     Author/
 Revision                No.                 Report Number               Issue Date           Description
                                                                                                                   Revised by
     1.0          RXZ181204009              RXZ181204009-00              2018.12.21         Original Report           Kaylee




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 2 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                                    No.: RXZ181204009-00




                                              TABLE OF CONTENTS
1     General Information ....................................................................................................... 4
    1.1       Product Description for Equipment under Test (EUT) ......................................................... 4
    1.2       Objective ............................................................................................................................... 5
    1.3       Related Submittal(s)/Grant(s)................................................................................................ 5
    1.4       Test Methodology.................................................................................................................. 5
    1.5       Test Facility ........................................................................................................................... 5
2         System Test Configuration ........................................................................................... 6
    2.1       Description of Test Configuration ......................................................................................... 6
    2.2       Equipment Modifications ...................................................................................................... 6
    2.3       EUT Exercise Software ......................................................................................................... 6
    2.4       Support Equipment List and Details...................................................................................... 6
    2.5       External Cable List and Details ............................................................................................. 6
    2.6       Block Diagram of Test Setup ................................................................................................ 7
3     Summary of Test Results ................................................................................................ 8

4     Test Equipment List and Details ................................................................................... 9

5         FCC §15.203 – Antenna Requirements ..................................................................... 10
    5.1       Applicable Standard ............................................................................................................ 10
    5.2       Antenna Connected Construction ........................................................................................ 10
6     FCC §15.209, §15.205 , §15.231(b) – Radiated Emissions ......................................... 11
    6.1       Applicable Standard ............................................................................................................ 11
    6.2       Measurement Uncertainty ................................................................................................... 12
    6.3       EUT Setup ........................................................................................................................... 12
    6.4       EMI Test Receiver & Spectrum Analyzer Setup................................................................. 13
    6.5       Test Procedure ..................................................................................................................... 13
    6.6       Corrected Factor & Margin Calculation .............................................................................. 13
    6.7       Test Results Summary ......................................................................................................... 13
    6.8       Environmental Conditions ................................................................................................... 13
    6.9       Test Results ......................................................................................................................... 14
7     FCC §15.231(a)(1) – Deactivation Testing .................................................................. 20
    7.1       Applicable Standard ............................................................................................................ 20
    7.2       Test Procedure ..................................................................................................................... 20
    7.3       Environmental Conditions ................................................................................................... 20
    7.4       Test Results ......................................................................................................................... 21
8     FCC §15.231(c) – 20 dB Emission Bandwidth Testing .............................................. 22
    8.1       Applicable Standard ............................................................................................................ 22
    8.2       Test Procedure ..................................................................................................................... 22
    8.3       Environmental Conditions ................................................................................................... 22
    8.4       Test Results ......................................................................................................................... 23




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 3 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00



1 General Information
1.1     Product Description for Equipment under Test (EUT)
 Applicant                                 Superior Electronics Corporation
                                           No.10, Lane 31, Chongde St., Sinyi District, Taipei City 110,
                                           Taiwan (R.O.C.)
 Manufacturer                              Superior Electronics Corporation
                                           No.10, Lane 31, Chongde St., Sinyi District, Taipei City 110,
                                           Taiwan (R.O.C.)
 Brand(Trade) Name                         ENFORCER
 Product (Equipment)                       Wireless Help Button
 Main Model Name                           RM-R100-TBQ
 Series Model Name                         SD-862M-GWSQ
                                           The major electrical and mechanical constructions of series
                                           models are identical to the basic model, except different
 Model Discrepancy
                                           appearance color. The model, RM-R100-TBQ is the testing
                                           sample, and the final test data are shown on this test report.
 Frequency Range                           433.92MHz
 Number of Channels                        1 Channel
 Antenna Specification                     PCB Antenna / -2 dBi

                                                AC 120V/60Hz
                                                  Adapter
                                                  By AC Power Cord
                                                  PoE
 Power Operation                                DC Type
 (Voltage Range)                                   Battery 9Vdc
                                                   DC Power Supply
                                                   External from USB Cable
                                                External DC Adapter
                                                Host System
 Received Date                             Dec 04, 2018
 Date of Test                              Dec 16, 2018 ~ Dec 17, 2018
*All measurement and test data in this report was gathered from production sample serial number: 181204009
(Assigned by BACL, Taiwan).




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 4 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00


1.2     Objective
This report is prepared on behalf of Superior Electronics Corporation All the test measurements were
performed according to the measurement procedure described in ANSI C63.10 - 2013.
The tests were performed in order to determine compliance with FCC Part 15, Subpart C, section
15.203, 15.205, 15.209, 15.35(c) and 15.231 rules.


1.3     Related Submittal(s)/Grant(s)
N/A.

1.4     Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American
National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

1.5     Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Taiwan) to collect test data is located
on
     70, Lane 169, Sec. 2, Datong Road, Xizhi Dist., New Taipei City 22183, Taiwan, R.O.C.
     68-3, Lane 169, Sec. 2, Datong Road, Xizhi Dist., New Taipei City 22183, Taiwan, R.O.C.


Bay Area Compliance Laboratories Corp. (Taiwan) Lab is accredited to ISO 17025 by Taiwan
Accreditation Foundation (TAF code: 3180) and the FCC designation No.TW3180 under the Mutual
Recognition Agreement (MRA) in FCC Test. The facility also complies with the radiated and AC line
conducted test site criteria set forth in ANSI C63.10.


The Federal Communications Commission has the reports on file and is listed under FCC Registration
No.: 974454. The test site has been approved by the FCC for public use and is listed in the FCC Public
Access Link (PAL) database.




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 5 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00



2       System Test Configuration
2.1     Description of Test Configuration
Channel list:
                                                                           Frequency
                                            Channel
                                                                             (MHz)
                                                 1                            433.92



2.2     Equipment Modifications
No modification was made to the EUT.


2.3     EUT Exercise Software
No test software was used.


2.4     Support Equipment List and Details
      Description           Manufacturer             Model Number            BSMI            FCC ID                   S/N

          N/A                     N/A                     N/A                 N/A              N/A                    N/A



2.5     External Cable List and Details
      Cable Description                   Length (m)                          From                               To

              N/A                              N/A                             N/A                              N/A




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 6 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00


2.6     Block Diagram of Test Setup
See test photographs attached in setup photos for the actual connections between EUT and support
equipment.

Radiation:
Below 1GHz:




Above 1GHz:




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 7 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00



3 Summary of Test Results
              FCC Rules                                      Description of Test                               Results

                 §15.203                                     Antenna Requirement                             Compliance

               §15.207(a)                                    Conducted Emissions                           Not applicable

    §15.205, §15.209, §15.231(b)                              Radiated Emissions                             Compliance

             §15.231(a)(2)                                         Deactivation                              Compliance

               §15.231(c)                                          Deactivation                              Compliance


Not applicable: Device only supports battery.




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 8 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00



4 Test Equipment List and Details
                                                                         Serial                 Calibration       Calibration
     Description             Manufacturer                  Model
                                                                       Number                      Date            Due Date
                                                   Radiated Room (966-A)
                        SUNOL
Bilog Antenna with                                                         A050115/1554
                   SCIENCES & MINI-                   JB6/UNAT-6+                               2017/12/20         2018/12/19
 6 dB Attenuator                                                               2_01
                       CIRCUITS
    Horn Antenna                  EMCO                      3115              9311-4158         2018/04/20         2019/04/19

    Horn Antenna              ETS-Lindgren                  3116                62638           2018/08/29         2019/08/28

     Preamplifier                Sonoma                     310N                130602          2018/07/04         2019/07/03

     Preamplifier        EM Electronics Corp.           EM01G18G                060657          2018/12/07         2019/12/06

      Microware              EM Electronics
                                                        EM18G40G                060656          2018/01/15         2019/01/14
     Preamplifier             Corporation
 EMI Test Receiver         Rohde & Schwarz                  ESR7                101419          2018/10/23         2019/10/22

 Spectrum Analyzer         Rohde & Schwarz                 FSV40                101435          2018/02/12         2019/02/13
                                                      FSCM 64639 /
  Micro flex Cable              UTIFLEX                                        93D0127          2018/07/31         2019/07/30
                                                          (2M)
                                                       UFA210A-1-            MFR64639
  Micro flex Cable              UTIFLEX                                                         2018/11/16         2019/11/15
                                                       3149-300300           226389-001
                                                     K1K50-UP0264-
  Micro flex Cable              ROSNOL                                        160309-1          2018/03/05         2019/03/04
                                                     K1K50-450CM
                                                     K1K50-UP0264-
  Micro flex Cable              ROSNOL                                        160309-2          2018/01/17         2019/01/16
                                                      K1K50-80CM
      Turn Table                 Champro                  TT-2000             060772-T             N.C.R              N.C.R

   Antenna Tower                 Champro              AM-BS-4500-B            060772-A             N.C.R              N.C.R

      Controller                 Champro                  EM1000                60772              N.C.R              N.C.R

       Software                    Farad                 EZ_EMC             BACL-03A1              N.C.R              N.C.R

*Statement of Traceability: BACL Corp. attests that all of the calibrations on the equipment items listed above
were traceable to the SI System of Units via the R.O.C. Center for Measurement Standards of the Electronics
Testing Center, Taiwan (ETC) or to another internationally recognized National Metrology Institute (NMI),
and were compliant with the current Taiwan Accreditation Foundation (TAF) requirements




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 9 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00



5       FCC §15.203 – Antenna Requirements
5.1     Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by theresponsible
party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique
coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section.


5.2     Antenna Connected Construction
The EUT has a PCB antenna which was permanently attached and the antenna gain is 0dBi; fulfill the requirement
of this section. Please refer to EUT photos.


Result: Compliant.




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 10 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00



6 FCC §15.209, §15.205 , §15.231(b) – Radiated Emissions
6.1      Applicable Standard
FCC §15.205, §15.209, §15.231 (b)
According to FCC §15.231(b), the field strength of emissions from intentional radiators operated under
this section shall not exceed the following:
      Fundamental frequency                   Field strength of fundamental                 Field strength of spurious
            (MHz)                                   (microvolts/meter)                     emission (microvolts/meter)
              40.66 – 40.70                                    2250                                        225
                70 – 130                                       1250                                        125
                130 – 174                               1250 to 3750 **                              125 to 375 **
                174 – 260                                      3750                                        375
                160 – 470                              3750 to 12500 **                             375 to 1250 **
               Above 470                                      12500                                       1250
(1) The above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the band
edges.
(2) Intentional radiators operating under the provisions of this section shall demonstrate compliance with the
limits on the field strength of emissions, as shown in the above table, based on the average value of the measured
emissions. As an alternative, compliance with the limits in the above table may be based on the use of
measurement instrumentation with a CISPR quasi-peak detector. The specific method of measurement employed
shall be specified in the application for equipment authorization. If average emission measurements are employed,
the provisions in §15.35 for averaging pulsed emissions and for limiting peak emissions apply. Further,
compliance with the provisions of §15.205 shall be demonstrated using the measurement instrumentation
specified in that section.
(3) The limits on the field strength of the spurious emissions in the above table are based on the fundamental
frequency of the intentional radiator. Spurious emissions shall be attenuated to the average (or, alternatively,
CISPR quasi-peak) limits shown in this table or to the general limits shown in §15.209, whichever limit permits
a higher field strength.




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 11 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00


6.2     Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing
to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna directivity, antenna factor
variation with height, antenna phase center variation, antenna factor frequency interpolation, measurement
distance variation, site imperfections, mismatch (average), and system repeatability.
Based on CISPR 16-4-2:2011, the expended combined standard uncertainty of radiation emissions at Bay Area
Compliance Laboratories Corp. (Taiwan) is shown in below table. And the uncertainty will not be taken into
consideration for the test data recorded in the report.


                 Frequency                                               Measurement uncertainty

             30 MHz~200 MHz                                       3.75 dB (k=2, 95% level of confidence)
              200 MHz~1 GHz                                       4.21 dB (k=2, 95% level of confidence)
               1 GHz~6 GHz                                        4.83 dB (k=2, 95% level of confidence)
               6 GHz~18 GHz                                       5.18 dB (k=2, 95% level of confidence)
              18 GHz~26 GHz                                       4.55 dB (k=2, 95% level of confidence)
              26 GHz~40 GHz                                       4.67 dB (k=2, 95% level of confidence)


6.3     EUT Setup
Below 1 GHz:




Above 1 GHz:




Radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance with the
ANSI C63.10-2013. The specification used was the FCC Part 15.209 and FCC 15.231 Limits.

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 12 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00

6.4     EMI Test Receiver & Spectrum Analyzer Setup
The system was investigated from 30 MHz to 4 GHz. During the radiated emission test, the EMI test receiver
was set with the following configurations measurement method 6.3 in ANSI C63.10.


                        Frequency Range                RBW                 VBW               Detector
                          30-1000 MHz                 100 kHz            300 kHz                 PK
                           Above 1 GHz                1 MHz               3 MHz                  PK




6.5     Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.


6.6     Corrected Factor & Margin Calculation
The Correct Factor is calculated by adding the Antenna Factor and Cable Loss, and subtracting the Amplifier
Gain from the Meter Reading. The basic equation is as follows:


                            Correct Factor = Antenna Factor + Cable Loss – Amplifier Gain


The “Margin” column of the following data tables indicates the degree of compliance with the applicable limit.
For example, a margin of -7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:


                                                   Margin = Result – Limit




6.7     Test Results Summary
According to the data in the following table, the EUT complied with the FCC §15.209 Limit.




6.8     Environmental Conditions
 Temperature:                                 25 ℃

 Relative Humidity:                            55 %
 ATM Pressure:                              1010 hPa
The testing was performed by Tom Hsu on 2018-12-16 ~ 2018-12-17.




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 13 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00


6.9     Test Results
Test Mode: Transmitting
30MHz-1GHz (GFSK modulation) (Pre-scan with three orthogonal axis, and worse case as Z axis.)


Horizontal
30MHz-1GHz:




1GHz-4GHz:




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 14 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00


Vertical
30MHz-1GHz:




1GHz-4GHz:




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 15 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00


Below 1GHz
Horizontal
  Frequency       Reading         Correct             Result         Limit        Margin       Height      Degree       Remark
    (MHz)         (dBμV)        Factor(dB/m)        (dBμV/m)       (dBμV/m)        (dB)         (cm)        (°)
    124.09          26.69            -9.21            17.48           43.5         -26.02        100         234           QP
    200.72          24.41            -8.92            15.49          80.83         -65.34        100         115           QP
   *433.92          85.83            -5.40            80.43          100.83         -20.4        242          11          Peak
   *433.92          80.43            -8.04            72.39          80.83          -8.44        242          11          Ave
    578.05          28.02             -3.7            24.32          80.83         -56.51        100         227           QP
    650.8           39.31            -2.84            36.47          80.83         -44.36        100         172           QP
    759.44          37.02            -1.51            35.51          80.83         -45.32        100         360           QP
    867.84          51.64             0.34            51.98          80.83         -28.85        100          7           Peak
    867.84          51.98            -8.04            43.94          60.83         -16.89        100          7           Ave


Vertical
  Frequency       Reading         Correct             Result         Limit        Margin       Height      Degree       Remark
    (MHz)         (dBμV)        Factor(dB/m)        (dBμV/m)       (dBμV/m)        (dB)         (cm)        (°)
    141.55          26.44            -9.51            16.93          80.83          -63.9        100         311           QP
    201.69          24.21            -9.15            15.06          80.83         -65.77        100         311           QP
    353.01          24.28             -6.8            17.48          80.83         -63.35        100          96           QP
   *433.92          79.95            -5.40            74.55          100.83        -26.28        233         264          Peak
   *433.92          74.55            -8.04            66.51          80.83         -14.32        233         264          Ave
    650.8           40.11            -2.84            37.27          80.83         -43.56        100         262           QP
    759.44          29.82            -1.51            28.31          80.83         -52.52        100         306           QP
    867.84          38.36             0.34             38.7          80.83         -42.13        100         223          Peak
    867.84           38.7            -8.04            30.66          60.83         -30.17        100         223          Ave


Note 1:
Corrected Factor (dB/m) = Antenna factor (RX) (dB/m) + Cable Loss (dB) – Amplifier Factor (dB)
Margin (dB) = Result (dBμV /m) – Limit (dBμV/m)
Note 2:
Calculate Average value based on Duty Cycle correction factor:
Tp = 52.403ms
Ton = Burst1*N1 + Burst2*N2 = 0.671*21 + 0.333*20 = 14.091 + 6.66 = 20.751ms
Duty Cycle Corrected Factor = 20*log(Ton/Tp) = 20*log(20.751ms/52.403ms) = -8.04dB
Average value = Peak value + Duty Cycle Corrected Factor




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 16 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00


Above 1GHz
Horizontal
  Frequency       Reading         Correct             Result         Limit        Margin       Height      Degree       Remark
    (MHz)         (dBμV)        Factor(dB/m)        (dBμV/m)       (dBμV/m)        (dB)         (cm)        (°)
  1301.760          71.92            -8.18            63.74          80.83         -17.09        219          61         peak
  1301.760          63.74            -8.04            55.70          60.83          -5.13        219          61         AVG
  1735.680          56.72            -6.20            50.52          80.83         -30.31        146          82         peak
  1735.680          50.52            -8.04            42.48          60.83         -18.35        146          82         AVG
  2169.600          51.99            -4.44            47.55          80.83         -33.28        112         199         peak
  2169.600          47.55            -8.04            39.51          60.83         -21.32        112         199         AVG
  2603.520          64.26            -3.29            60.97          80.83         -19.86        139          16         peak
  2603.520          60.97            -8.04            52.93          60.83          -7.90        139          16         AVG


Vertical
  Frequency       Reading         Correct             Result         Limit        Margin       Height      Degree       Remark
    (MHz)         (dBμV)        Factor(dB/m)        (dBμV/m)       (dBμV/m)        (dB)         (cm)        (°)
  1301.760          67.94            -8.18            59.76          80.83         -21.07        214         140         peak
  1301.760          59.76            -8.04            51.72          60.83          -9.11        214         140         AVG
  1735.680          59.81            -6.20            53.61          80.83         -27.12        215         346         peak
  1735.680          53.61            -8.04            45.57          60.83         -15.26        215         346         AVG
  2169.600          48.89            -4.44            44.45          80.83         -36.38        100          90         peak
  2169.600          44.45            -8.04            36.41          60.83         -24.42        100          90         AVG
  2603.520          50.26            -3.29            46.97          80.83         -33.86        100          20         peak
  2603.520          46.97            -8.04            38.93          60.83         -21.90        100          20         AVG


Note 1:
Corrected Factor (dB/m) = Antenna factor (RX) (dB/m) + Cable Loss (dB) – Amplifier Factor (dB)
Margin (dB) = Result (dBμV /m) – Limit (dBμV/m)
Note 2:
Calculate Average value based on Duty Cycle correction factor:
Tp = 52.403ms
Ton = Burst1*N1 + Burst2*N2 = 0.671*21 + 0.333*20 = 14.091 + 6.66 = 20.751ms
Duty Cycle Corrected Factor = 20*log(Ton/Tp) = 20*log(20.751ms/52.403ms) = -8.04dB
Average value = Peak value + Duty Cycle Corrected Factor




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 17 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                              No.: RXZ181204009-00


                                                               Duty Cycle
                                                              Tp=52.403ms
                                                                       RBW 100 kHz   Delta 2 [T1 ]
                                                                      *VBW 300 kHz               0.59 dB
                         Ref     0 dBm              *Att   10 dB       SWT 300 ms           52.403846 ms
                         0                                                           Marker 1 [T1 ]
                                                                                               -28.89   dBm
                         -10
                                                                                           107.211538   ms     A
                                                                                     Delta 1 [T1 ]            SGL
                1 PK *                                                                           0.38   dB
                CLRWR                                                                       41.346154   ms
                         -20

                                                       1            1 2
                         -30


                         -40



                         -50

                                                                                                              3DB
                         -60



                         -70


                         -80



                         -90


                         -100
                         Center 433.92 MHz                         30 ms/




               Date: 16.DEC.2018         16:32:57




                                                                Zoom in
                                                              N1=21, N2=20
                                                                       RBW 100 kHz   Delta 1 [T1 ]
                                                                      *VBW 300 kHz               0.39 dB
                         Ref     0 dBm              *Att   10 dB       SWT 50 ms            40.865385 ms
                         0                                                           Marker 1 [T1 ]
                                                                                               -33.51 dBm
                         -10
                                                                                             2.804487 ms       A
                                                                                                              SGL
                1 PK *
                CLRWR
                         -20



                         -30 1                                                                1


                         -40



                         -50

                                                                                                              3DB
                         -60



                         -70


                         -80



                         -90


                         -100
                         Center 433.92 MHz                         5 ms/




               Date: 16.DEC.2018         16:34:06




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 18 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                            No.: RXZ181204009-00


                                                          Duty Cycle Burst 1
                                                                       RBW 100 kHz   Delta 1 [T1 ]
                                                                     *VBW 300 kHz                0.36 dB
                         Ref    0 dBm              *Att   10 dB        SWT 3 ms            671.474359 µs
                         0                                                           Marker 1 [T1 ]
                                                                                               -31.60 dBm
                         -10
                                                                                             1.160256 ms     A
                                                                                                            SGL
                1 PK *
                CLRWR
                         -20


                                                          1                 1
                         -30


                         -40



                         -50

                                                                                                            3DB
                         -60



                         -70


                         -80



                         -90


                         -100
                         Center 433.92 MHz                        300 µs/




               Date: 16.DEC.2018        16:35:50




                                                          Duty Cycle Burst 2




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 19 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00


7 FCC §15.231(a)(1) – Deactivation Testing
7.1     Applicable Standard
Per FCC §15.231(a) (1), A manually operated transmitter shall employ a switch that will automatically deactivate
the transmitter within not more than 5 seconds of being released


7.2     Test Procedure
1.    With the EUT’s antenna attached, the waveform was received by the test antenna which was connected to
      the spectrum analyzer.
2.    Set center frequency of spectrum analyzer=operating frequency.
3.    Set the spectrum analyzer as RBW=100k VBW=300k Span=0Hz.
4.    Repeat above procedures until all frequency measured was complete.




7.3     Environmental Conditions
 Temperature:                                 25 ℃

 Relative Humidity:                            55 %
 ATM Pressure:                              1010 hPa
The testing was performed by Tom Hsu on 2018-12-16.




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 20 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                          No.: RXZ181204009-00

7.4     Test Results
Test mode: Transmitting


GFSK Modulation


                                                                         5s
                                                                     RBW 100 kHz   Delta 1 [T1 ]
                                                                    *VBW 300 kHz             -55.76 dB
                         Ref    0 dBm              *Att   10 dB      SWT 10 s              5.000000 s
                         0                                                         Marker 1 [T1 ]
                                                                                             -22.08 dBm
                         -10                                                               1.282051 s      A
                                                                                                          SGL
                1 PK *
                CLRWR               1
                         -20


                         -30


                         -40


                         -50

                                                                                                          3DB
                         -60



                         -70
                                                                              1

                         -80


                         -90


                         -100
                         Center 433.92 MHz                        1 s/




               Date: 16.DEC.2018        16:50:55




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 21 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                    No.: RXZ181204009-00


8 FCC §15.231(c) – 20 dB Emission Bandwidth Testing
8.1     Applicable Standard
Per 15.231(c), The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
operating above 70 MHz and below 900 MHz. Bandwidth is determined at the points 20 dB down from the
modulated carrier.




8.2     Test Procedure
With the EUT’s antenna attached, the waveform was received by the test antenna which was connected to the
spectrum analyzer, plot the 20 dB bandwidth.




8.3     Environmental Conditions
 Temperature:                                 25 ℃

 Relative Humidity:                            55 %
 ATM Pressure:                              1010 hPa
The testing was performed by Tom Hsu on 2018-12-16.




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 22 of 23


 Bay Area Compliance Laboratories Corp.(Taiwan)                                                            No.: RXZ181204009-00




8.4     Test Results
                                          20 dB Emission
         Frequency                                                                    Limit
                                             Bandwidth                                                                 Result
           (MHz)                                                                      (kHz)
                                                 (kHz)
           433.92                                48.718                               1085                           Compliance
Note: Limit = 0.25% * Center Frequency = 0.25% * 433.92 MHz = 1085 kHz




                                                 20 dB Emission Bandwidth
                                                                    *RBW 10 kHz       Marker 1 [T1 ]
                                                                    *VBW 30 kHz                 -28.09 dBm
                       Ref    0 dBm              *Att   10 dB        SWT 10 ms           433.977692308 MHz
                       0                                                              ndB [T1]   20.00   dB
                                                                                      BW 48.717948718    kHz
                       -10                                                            Temp 1 [T1 ndB]          A
                                                                                                -48.14   dBm
                1 PK                                                                     433.954294872   MHz
                MAXH                                                                  Temp 2 [T1 ndB]
                       -20
                                                                                                -48.18   dBm
                                                                                         1
                                                                                         434.003012821   MHz
                       -30


                       -40
                                                                                 T1                T2
                       -50

                                                                                                               3DB
                       -60


                       -70


                       -80


                       -90


                       -100
                       Center 433.92 MHz                        20 kHz/                       Span 200 kHz




               Date: 16.DEC.2018      16:45:02




                                             ***** END OF REPORT *****




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Taiwan)                   Page 23 of 23



Document Created: 2019-03-23 19:21:56
Document Modified: 2019-03-23 19:21:56

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC