Installation Manual


SK-939TP2AQ (433.92MHz)
SK-910RB-4Q (433.92MHz)
SK-910RB2-4Q (433.92MHz)                                                                                              SK-910RB2Q shown



One- and Two-Channel RF Receivers
 Flexible operating voltage: 11~24 VAC/VDC
 Up to 500ft (152m) range
 Independently programmable channels
                                                                                                SK-939TP2AQ




Note: Products with model numbers that end with “Q” or that have a round green “Q” sticker are RoHS compliant.


Also Available from SECO-LARM:
            SK-910RLQ ........................................... Low-voltage, one-channel receiver, 315MHz *
            SK-910RVQ ......................................................... Low-voltage, one-channel receiver,
                                                                                 transistor ground output 315MHZ
            SK-910RL-4Q ................................... Low-voltage, one-channel receiver, 433.92MHz
            SK-910RV-4Q ...................................................... Low-voltage, one-channel receiver, *
                                                                             transistor ground output, 433.92MHz

This manual covers only one- and two-channel receivers. For information four-channel receivers, please contact SECO-LARM.


Introduction:
The SK-910RBQ and SK-910RB2Q are wireless receivers that meets the growing demand for
receivers with multiple and independently controlled output functions. These RF receivers are
compatible with both code hopping and fixed code transmitters (see page 4 of this manual for a list of
compatible transmitters). The receivers can be used to control a variety of home automation devices
such as garage door openers, lights, motorized gates, lifts, or other devices remotely.
Installation Notes:
1. Mount the receiver out of sight in a location where it is not exposed to weather or moisture, and
   where it is not surrounded by metal. Metal will block the RF signal, resulting in a reduced range.
2. For best range, pull the antenna wire as long and straight as possible. If the receiver receives
   interference from local RF activity (e.g., an airport or military base), the antenna wire can be folded.
IMPORTANT: DO NOT CUT THE ANTENNA WIRE.


 ENFORCER Two-Channel RF Receiver
Code Learning a New SK-939TP2AQ Transmitter Button:
Each receiver channel can learn the codes of up to 15 different transmitters on a first-in, first-out basis. Below is the
procedure for code learning a new transmitter button.
1. Press the channel mode switch of the desired channel for 3 seconds or more. The channel’s LED will start to flash
    quickly to indicate that it is in learning mode.
2. While the LED is flashing, press the button of the transmitter to be learned one time. The receiver’s channel indicator
    LED will flash once to indicate the transmitter button has been successfully learned. After the button has been learned,
    the receiver will automatically exit learning mode. To learn further codes, repeat step 1 to re-enter learning mode.
NOTES:
 The channel mode switch(es) can be found at the rear of the receiver’s case.
 The channel’s indicator LED will flash a maximum of 15 seconds. If no transmitter button is pressed during this time, the
    receiver will exit code learning mode, and the LED will turn off.
 If the code being learned has already been learned, the channel indicator LED will turn steady ON and then start flashing
    again. The code will not be learned a second time.
 One channel can learn the codes of a maximum of 15 transmitter buttons. If you attempt to learn a sixteenth transmitter
    code, the earliest code learned will be deleted and the new code will be learned.

Clear Channel Memory:
To clear all codes from a channel’s memory, press the channel’s mode switch for 3 seconds or more until the channel
indicator LED flashes. Release, and then press the switch again for 3 seconds or more until the LED stops flashing. The
LED will then flash twice to indicate that all codes associated with that channel have been deleted.


Display Channel Memory:
To see how many codes have been learned by a channel, press that channel’s mode switch once. The number of codes
stored in the channel’s memory is equal to the number of times the channel indicator LED flashes.


Programming Channel Relay Output Function:
Each channel relay can be programmed for one of five output functions. SK-910RB2Q only: Each channel can be
independently programmed to operate in a different function, depending on the user’s application. The five functions are:
1. 4-Second Timed Output (default) – When the transmitter button is pressed, the relay will turn ON for 4 seconds.
2. Toggle Output – Works much like a toggle switch to turn a device ON & OFF alternately. Press the transmitter button
   once, and the relay turns ON. Press the transmitter button again, and the relay turns OFF.
3. Latch Output – Press the transmitter button once, and the relay turns ON and stays ON. The channel relay will remain
   ON regardless of whether a compatible transmitter button is pressed again or not. To turn the relay OFF, press the
   channel’s mode switch on the receiver once to reset.
4. Validity Output – The channel will turn the relay ON for as long as the transmitter button is pressed.
   Note: Due to possible interference or drops in transmitter battery power while the transmitter button is continuously
   pressed (even for short periods of time), the receiver may lose the transmitter’s signal and turn the relay OFF.
5. 1-Second Timed Output – When the transmitter button is pressed, the relay will turn ON for 1 second.
Selecting the relay output function:                                               Toggle Output
 Hold down the channel function switch for 3 or more                               (2 flashes)
  seconds. The channel’s LED will flash a number of
  times equal to the output mode that it is in.              4-sec (default)
                                                                                                       Latch Output
 To change a channel’s function, press the channel’s        Timed Output
                                                                                                        (3 flashes)
  function switch. Each press moves to the next                 (1 flash)
  function in the sequence as shown in the diagram to
  the right.
 After changing functions, count the number of times
  the channel LED flashes to verify the channel is set
                                                                  1-sec Timed Output               Validity Output
  to the correct function.
                                                                      (5 flashes)                   (4 flashes)
 To exit function programming, hold the appropriate
  function switch for 3 seconds, or wait 15 seconds.           Note: For a diagram of the PC board, including the location
                                                               of the function switch(es), please see Overview, page 3.


   2                                                                                 SECO-LARM U.S.A., Inc.


                                                                     ENFORCER Two-Channel RF Receiver
Overview:                                                            Channel 1 mode switch
                                                                     Channel 2 mode switch (SK-910RB2Q only)
                                                                                                          LP3 antenna program
                                                                                                          loop
                                                                                                          3-Pin antenna port
              CH 1           CH 2
                                                                               SK-910RB2Q shown. SK-910RBQ is the
      Channel Function Switches
       Brown function switch is                                               same, but only has one each: mode
        for channel 1 programming.                                             switch; function switch; indicator LED;
       Red function switch is for                                             channel relay.
        channel 2 programming.
         (SK-910RB2Q only)                                                                        COM
                                                                                                  N.C.      Ch 2 relay
                                                                                                  N.O.      (SK-910RB2Q only)
                                                                                                  COM
                                                                                                  N.C.      Ch 1 relay
       Ch 1 indicator LED                                                                         N.O.
       Ch 2 indicator LED                                                                          —
       (SK-910RB2Q only)
                                                                                                   +        Power input
        (PC board shown. Remove the front cover of the receiver to access the function switch(es) and terminal block.)

Channel Mode Switch Operation (One per Channel):
 Learn mode                    Press and hold the channel mode switch for three seconds or more.
                               Press and hold the channel mode switch for three seconds or more, then when the LED starts
 Clear memory
                               flashing, press again for three seconds to delete all previously learned codes.
                               If the channel was programmed for latch output, once the relay is turned ON with a transmitter
 Reset latched output
                               button, press the channel mode switch of that channel once to turn the relay OFF.
                               Press and release the channel mode switch to show the number of codes stored. The LED will
 Memory Display
                               flash a number of times corresponding to the number of codes stored.


LED Indication (One per Channel):
                               Receiving signal from a transmitter button during normal operation, or indicates a transmitter
 Steady ON
                               button’s code already exists in the receiver’s memory during code learning.
                               Receiver is in code-learning mode or channel memory display mode, or during the programming
 Fast flash
                               channel output mode.
 One flash                     A transmitter button code was learned, or receiver channel is in 4-second timed output mode.
                               All previously learned transmitter buttons were deleted, or receiver channel is in toggle output
 Two flashes
                               mode.
 Three flashes                 Receiver channel is in latched output mode.
 Four flashes                  Receiver channel is in validity output mode.
 Five flashes                  Receiver channel is in 1-second timed output mode.
                               During normal operation, pressing a channel mode switch will cause the channel indicator LED
 0~15 flashes
                               to flash. Number of flashes indicates the number of transmitter buttons currently stored.


Extended Range Antenna (Optional):
The SECO-LARM SK-91ERSDQ extends RF receiver range up to                                        SK-91ERSDQ
1,000ft (304m) (open air) with existing remotes. It comes with a 9ft
(2.7m) cable that easily plugs into the 3-pin antenna port located on the
RF receiver.
Note:
 If an extended range antenna is used, the ―LP3‖ on the receiver PC
    board must be cut.
 Actual antenna range will vary greatly depending on the operating
    environment.

   SECO-LARM U.S.A., Inc.                                                                                                         3


 ENFORCER Two-Channel RF Receiver
Sample Applications:
  Positive Output                                                                        Negative Output
            COM               Positive Power Source                                              COM             Negative Power Source
             NC                                                                                   NC
             NO               Positive Power Output                                               NO             Negative Power Output

             —                                                                                    —
                              Power for SK-910RBQ/SK-910RB2Q                                                     Power for SK-910RBQ/SK-910RB2Q
             +                                                                                    +

  Typical N.C. Application                                                               Typical N.O. Application
                                                                                                                                               SD-996C-NUQ
            COM                                                                                  COM                                         Electric Door Strike
             NC                                                E-941SA-1200                       NC
             NO                                             Electromagnetic Lock                  NO

             —                                                                                    —
             +                                                                                    +


  N.C. Application with Independent Power Sources                                        N.O. Application with Independent Power Sources
                                DC Power                                                                          DC Power
                                 Source                                                         COM                Source
            COM                                                                                  NC
             NC                                                                                  NO
             NO                                                                                                                              SD-996C-NUQ
                                                                                                 —           AC Power                      Electric Door Strike
             —             AC Power                      E-941SA-1200                            +            Source
             +              Source                    Electromagnetic Lock


Specifications:
                                      SK-910RBQ/SK-910RB2Q                                                     315MHz
       Operating frequency
                                      SK-910RB-4Q/SK-910RB2-4Q                                               433.92MHz
       Memory capacity                                                                       15 transmitter button codes per channel
       Operating voltage                                                                                  11~24 VAC/VDC
                                      Standby                                                              8mA@12VDC
       Operating current
                                      Active                                                        30mA@12VDC per channel
       Relay contact rating                                                                Form C 10A@24VDC or 120VAC per channel
       Connectors                                                                       Screw terminals, +, -, with NO/NC/COM per channel
       Dimensions                                                                                  31/8‖x29/16‖x1‖ (80x65x25mm)

Compatible Transmitters:
                                                                                       315MHz                            433.92MHz
        Fixed Code: 68 billion codes                                           SK-919 Series Fixed Code           SK-939 Series Fixed Code
        CODEBUMP™: 18 quintillion (1.8x1019) codes                             SK-917 Series CODEBUMP             SK-937 Series CODEBUMP


                                                                       FCC ID: K4E939TP2A
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT
CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
Notice : The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate
the equipment.
IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any
change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the
device.

NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is
one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice.
SECO-LARM is also not responsible for misprints or typographical errors.

Copyright © 2013 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the
written permission of SECO-LARM.

SECO-LARM® U.S.A., Inc.
                                                                                                                                                        PITSW1
16842 Millikan Avenue, Irvine, CA 92606                                            Website: www.seco-larm.com                     SK-939TP2A_MuFCC_1310.docx
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326                                 E-mail: sales@seco-larm.com                               Part #: 762-116-2%

   4                                                                                                       SECO-LARM U.S.A., Inc.



Document Created: 2013-10-07 14:54:40
Document Modified: 2013-10-07 14:54:40

© 2024 FCC.report