Test Report

FCC ID: K4E3133PPQ

Test Report

Download: PDF
FCCID_4063807

                                                                                       Report No.: ATE20181750
                                                                                                    Page 1 of 21




                           APPLICATION CERTIFICATION FCC Part 15C
                                           On Behalf of
                                 Superior Electronics Corporation

              Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

                                     Model No.: SK-3133-PPQ

                                      FCC ID: K4E3133PPQ




            Prepared for        :   Superior Electronics Corporation
            Address             :   No. 10 Lane 31, Chongde St., Sinyi District, Taipei City,
                                    Taiwan 110

            Prepared by         :   Shenzhen Accurate Technology Co., Ltd.
            Address             :   1/F., Building A, Changyuan New Material Port, Science &
                                    Industry Park, Nanshan District, Shenzhen, Guangdong, P.R.
                                    China

                                    Tel: +86-755-26503290
                                    Fax: +86-755-26503396




            Report No.          :   ATE20181750
            Date of Test        :   October 9-October 11, 2018
            Date of Report      :   October 12, 2018




FCC ID: K4E3133PPQ                                                             Shenzhen Accurate Technology Co., Ltd


                                                                                                                                        Report No.: ATE20181750
                                                                                                                                                     Page 2 of 21


                                                             TABLE OF CONTENTS

    Description                                                                                                                                                  Page


    Test Report Declaration
     1.      TEST RESULTS SUMMARY ......................................................................................................... 4
     2.      GENERAL INFORMATION .......................................................................................................... 5
          2.1.     Description of Device (EUT)....................................................................................................................5
          2.2.     Special Accessory and Auxiliary Equipment ...........................................................................................5
          2.3.     Description of Test Facility ......................................................................................................................6
          2.4.     Measurement Uncertainty.........................................................................................................................6
     3.      MEASURING DEVICE AND TEST EQUIPMENT ..................................................................... 7
          3.1.     The Equipment Used to Measure Conducted Disturbance .......................................................................7
          3.2.     The Equipment Used to Measure Radiated Emission...............................................................................7
     4.      POWER LINE CONDUCTED MEASUREMENT ....................................................................... 8
          4.1.     Block Diagram of Test Setup....................................................................................................................8
          4.2.     Power Line Conducted Emission Measurement Limits............................................................................8
          4.3.     Configuration of EUT on Measurement ...................................................................................................8
          4.4.     Operating Condition of EUT ....................................................................................................................8
          4.5.     Test Procedure ..........................................................................................................................................9
          4.6.     Data Sample..............................................................................................................................................9
          4.7.     Power Line Conducted Emission Measurement Results ..........................................................................9
     5.      RADIATED EMISSION MEASUREMENT................................................................................ 14
          5.1.     Block Diagram of Test............................................................................................................................14
          5.2.     Radiated Emission Limit ........................................................................................................................15
          5.3.     EUT Configuration on Measurement .....................................................................................................15
          5.4.     Operating Condition of EUT ..................................................................................................................15
          5.5.     Test Procedure ........................................................................................................................................16
          5.6.     Data Sample............................................................................................................................................17
          5.7.     Radiated Emission Measurement Result ................................................................................................17
     6.      ANTENNA REQUIREMENT........................................................................................................ 21
          6.1.     The Requirement ....................................................................................................................................21
          6.2.     Antenna Construction .............................................................................................................................21




FCC ID: K4E3133PPQ                                                                                                            Shenzhen Accurate Technology Co., Ltd


                                                                                          Report No.: ATE20181750
                                                                                                       Page 3 of 21


                                       Test Report Declaration
             Applicant          :   Superior Electronics Corporation
             Address            :   No. 10 Lane 31, Chongde St., Sinyi District, Taipei City, Taiwan
                                    110

             Manufacturer       :   Superior Electronics Corporation
             Address            :   No. 10 Lane 31, Chongde St., Sinyi District, Taipei City, Taiwan
                                    110

             Product            :   Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

             Model No.          :   SK-3133-PPQ

             Measurement Procedure Used:

             FCC CFR47 Part 15 Subpart C Section 15.207 and 15.209
             ANSI C63.10: 2013


             The device described above is tested by Shenzhen Accurate Technology Co., Ltd. to determine
             the maximum emission levels emanating from the device. The maximum emission levels are
             compared to the FCC Part 15 Subpart C limits both radiated and conducted emissions. The
             measurement results are contained in this test report and Shenzhen Accurate Technology Co.,
             Ltd. is assumed full responsibility for the accuracy and completeness of these measurements.
             Also, this report shows that the Equipment Under Test (EUT) is to be technically compliant with
             the FCC requirements.

             This report applies to above tested sample only. This report shall not be reproduced in part
             without written approval of Shenzhen Accurate Technology Co., Ltd.


             Date of Test :                             October 9-October 11, 2018
             Date of Report :                               October 12, 2018



             Prepared by :
                                                           (Star Yang, Engineer)




             Approved & Authorized Signer :
                                                            (Sean Liu, Manager)




FCC ID: K4E3133PPQ                                                                Shenzhen Accurate Technology Co., Ltd


                                                                          Report No.: ATE20181750
                                                                                       Page 4 of 21



          1. TEST RESULTS SUMMARY

                Test Items                       Test Standard                  Test Results
                Power Line Conducted Emission   FCC Part 15.207                       Pass
                Radiated Emission               FCC Part 15.209                       Pass




FCC ID: K4E3133PPQ                                                Shenzhen Accurate Technology Co., Ltd


                                                                             Report No.: ATE20181750
                                                                                          Page 5 of 21



          2. GENERAL INFORMATION


                2.1.Description of Device (EUT)

                     M/N                          :   SK-3133-PPQ
                     Operation Frequency          :   125kHz
                     Modulation Type              :   GFSK
                     Antenna Gain                 :   0dBi
                     Type of Antenna              :   Coil Antenna
                     Rating                       :   12-24V AC/DC




                2.2.Special Accessory and Auxiliary Equipment

                     N/A




FCC ID: K4E3133PPQ                                                   Shenzhen Accurate Technology Co., Ltd


                                                                                         Report No.: ATE20181750
                                                                                                      Page 6 of 21



                2.3.Description of Test Facility
                     EMC Lab           :   Recognition of accreditation by Federal Communications
                                           Commission (FCC)
                                           The Designation Number is CN1189
                                           The Registration Number is 708358

                                           Listed by Innovation, Science and Economic Development
                                           Canada (ISEDC)
                                           The Registration Number is 5077A-2

                                           Accredited by China National Accreditation Service for
                                           Conformity Assessment (CNAS)
                                           The Registration Number is CNAS L3193

                                           Accredited by American Association for Laboratory
                                           Accreditation (A2LA)
                                           The Certificate Number is 4297.01

                     Name of Firm      :   Shenzhen Accurate Technology Co., Ltd
                     Site Location     :   1/F., Building A, Changyuan New Material Port, Science &
                                           Industry Park, Nanshan District, Shenzhen, Guangdong, P.R.
                                           China



                2.4.Measurement Uncertainty
                     Conducted emission expanded uncertainty         :   U=2.23dB, k=2

                     Radiated emission expanded uncertainty          :   U=3.08dB, k=2
                     (9kHz-30MHz)
                     Radiated emission expanded uncertainty          :   U=4.42dB, k=2
                     (30MHz-1000MHz)
                     Radiated emission expanded uncertainty          :   U=4.06dB, k=2
                     (Above 1GHz)




FCC ID: K4E3133PPQ                                                               Shenzhen Accurate Technology Co., Ltd


                                                                              Report No.: ATE20181750
                                                                                           Page 7 of 21



          3. MEASURING DEVICE AND TEST EQUIPMENT

            3.1. The Equipment Used to Measure Conducted Disturbance
Item Equipment           Manufacturer      Model No.   Serial No.   Last Cal.              Cal.
                                                                                           Interval
  1. Test Receiver    Rohde & Schwarz      ESCS30      100307       Jan.06, 2018           1 Year
  2. L.I.S.N.         Schwarzbeck          NLSK8126    8126431      Jan.06, 2018           1 Year
  3. Pulse Limiter    Rohde & Schwarz      ESH3-Z2     100305       Jan.06, 2018           1 Year
     50Ω Coaxial      Anritsu Corp         MP59B       6200283936   Jan.06, 2018           1 Year
  4.
     Switch
  5. RF Coaxial Cable SUHNER               N-2m        No.2         Jan.06, 2018           1 Year
  6. Measurement Software: ES-K1 V1.71

            3.2. The Equipment Used to Measure Radiated Emission
Item Equipment            Manufacturer     Model No.   Serial No.   Last Cal.             Cal.
                                                                                          Interval
  1. Spectrum Analyzer    Rohde&Schwarz    FSV40       101495       Jan.06, 2018          1 Year
  2. Test Receiver        Rohde& Schwarz   ESR         101817       Jan.06, 2018          1 Year
  3. Bilog Antenna        Schwarzbeck      VULB9163    9163-323     Jan.06, 2018          1 Year
  4. Loop Antenna         Schwarzbeck      FMZB1516    1516131      Jan.06, 2018          1 Year
  5. RF Switching         Compliance       RSU-M2      38322        Jan.06, 2018          1 Year
     Unit+PreAMP          Direction
  6. Pre-Amplifier        Agilent          8447D       294A10619    Jan.06, 2018          1 Year
  7. Pre-Amplifier        Rohde&Schwarz    CBLU11835   3791         Jan.06, 2018          1 Year
                                           40-01
  8.   50 Coaxial Switch Anritsu Corp      MP59B       6200506474   Jan.06, 2018          1 Year
  9.   RF Coaxial Cable   RESENBERGER N-12m            No.11        Jan.06, 2018          1 Year
 10.   RF Coaxial Cable   RESENBERGER N-0.5m           No.12        Jan.06, 2018          1 Year
 11.   RF Coaxial Cable   SUHNER           N-2m        No.13        Jan.06, 2018          1 Year
 12.   RF Coaxial Cable   SUHNER           N-0.5m      No.15        Jan.06, 2018          1 Year
 13.   RF Coaxial Cable   SUHNER           N-2m        No.16        Jan.06, 2018          1 Year
 14.   RF Coaxial Cable   RESENBERGER N-6m             No.17        Jan.06, 2018          1 Year
 15.   Measurement Software: EZ_EMC V1.1.4.2




FCC ID: K4E3133PPQ                                                    Shenzhen Accurate Technology Co., Ltd


                                                                                          Report No.: ATE20181750
                                                                                                       Page 8 of 21



          4. POWER LINE CONDUCTED MEASUREMENT


                4.1.Block Diagram of Test Setup

                                      Test Receiver
                     AC Mains


                                          L.I.S.N           EUT




                4.2.Power Line Conducted Emission Measurement Limits
                            Frequency                                   Limit dB(V)
                              (MHz)                    Quasi-peak Level                Average Level
                         0.15 - 0.50                     66.0 – 56.0 *                 56.0 – 46.0 *
                         0.50 - 5.00                          56.0                         46.0
                         5.00 - 30.00                         60.0                         50.0
                     NOTE1: The lower limit shall apply at the transition frequencies.
                     NOTE2: The limit decreases linearly with the logarithm of the frequency in the range
                             0.15MHz to 0.50MHz.


                4.3.Configuration of EUT on Measurement
                      The following equipments are installed on Power Line Conducted Emission Measurement
                      to meet the commission requirement and operating regulations in a manner, which tends
                      to maximize its emission characteristics in a normal application.
                        4.3.1.Heavy-Duty Outdoor Access Control Keypad with Proximity Reader (EUT)
                                Model Number : SK-3133-PPQ
                                Manufacturer : Superior Electronics Corporation


                4.4.Operating Condition of EUT
                        4.4.1. Setup the EUT and simulator as shown as Section 4.1.

                        4.4.2. Turn on the power of all equipment.

                        4.4.3. Let the EUT work in test mode and measure it.




FCC ID: K4E3133PPQ                                                                Shenzhen Accurate Technology Co., Ltd


                                                                                           Report No.: ATE20181750
                                                                                                        Page 9 of 21



                 4.5.Test Procedure
                      The EUT is put on the plane 0.8 m high above the ground by insulating support and is
                      connected to the power mains through a line impedance stabilization network (L.I.S.N.).
                      This provides a 50ohm coupling impedance for the EUT system. Please refer the block
                      diagram of the test setup and photographs. Both sides of AC lines are checked to find out
                      the maximum conducted emission. In order to find the maximum emission levels, the
                      relative positions of equipment and all of the interface cables shall be changed according
                      to ANSI C63.10: 2013 on Conducted Emission Measurement.
                      The bandwidth of test receiver (R & S ESCS30) is set at 9kHz.

                      The frequency range from 150kHz to 30MHz is checked.


                 4.6.Data Sample
Frequency     Transducer    QuasiPeak    Average    QuasiPeak   Average    QuasiPeak     Average          Remark
  (MHz)         value         Level       Level       Limit      Limit      Margin       Margin          (Pass/Fail)
                 (dB)        (dBV)      (dBV)      (dBV)     (dBV)       (dB)         (dB)
 X.XX            10.6          25.3        17.0        59.0       49.0       33.7         32.0               Pass

                      Transducer value = Insertion loss of LISN + Cable Loss
                      Result = Quasi-peak Level/Average Level + Transducer value
                      Limit = Limit stated in standard

                      Calculation Formula:

                      Margin = Limit – Reading level value – Transducer value


                 4.7.Power Line Conducted Emission Measurement Results

                      PASS.

                      The frequency range from 150kHz to 30MHz is checked.

                      Emissions attenuated more than 20 dB below the permissible value are not reported.

                      The spectral diagrams are attached as below.




 FCC ID: K4E3133PPQ                                                                Shenzhen Accurate Technology Co., Ltd


                             Report No.: ATE20181750
                                          Page 10 of 21




FCC ID: K4E3133PPQ   Shenzhen Accurate Technology Co., Ltd


ACCURATE TECHNOLOGY CO.,LTD

CONDUCTED EMISSION STANDARD FCC PART 15C

EUT:                 Eeavy—Duty Outdoor Access Control Keypad with Proximity Reader
Manufacturer:        SUPERRIOR ELECTRONICS CORPORATION
Operating Condition: ON
Test Site:           2#Shielding Room
Operator:            Frank
Test Specification:  L 24V/608z
Comment :            Report NO.:ATE20181750   M/N: SK—3133—PPQ
Start of Test        2018—10—9 / 9150145


SCAN TABLE: "V 150K—30MHz fin"
  Short Description:      _SUB_STD_VTERM2 1.70
  Start             Stop           Step            Detsctor         Meas.          IF       Transducer
  Frequency         Frequency      Width                           Time            Bandw.
  150.0 kEz         30.0 MHz        4.5 kHz        QuasiPeak        1.0 s          9 kBz    NSLK8126   2008
                                                  Average


   Level [dBuV]




                                                       Frequency [Hz]
x x xmBs    B—1750 —2_Ein
+o+ + ues   B—1750—2fin?
      ues   r—1750 ~2pre
      mes   B—1750—2pre2
uzx         ce is # ¥ or             voltage oP
  umm       roo is 2 v ay            Voltage 27




MEASUREMENT RESULT:                 "F—1750—2_fin"

2018—10—9         9: 52
   Frequency              Level    Transd     Limit    Margin           Detector     Line    PE
             MBz           dBpV        dB      dBpV        dB

    0. 361500             19. 40     10.9         59       39.3         QP           LL     GND
    0. 748500             23.10      11.1         56       32.3         QP           LL     GND
    1,464000              23.10      11.2         56       32.9         P            LL     GND
    2.130000              19.20      11.3         56       36.8         P            LL     GND
    5.338500               9.40      11.5         60       50.6         P            LL     GND
   24.004500              20 .00     11.7         60       40.0         P            LL     GND




MEASUREMENT RESULT:                 "F—1750—2_fin2"
2018—10—9         9: 52
   Frequency              Level    Transd     Limit    Margin           Detector     Line    PE
             MBz           dBpv        dB      dapv           dn

    0. 253500             17.00      10.9         52       34.6          AV          LL     GND
    0.775500              21.10      11.1         46       24.9         AV           LL     GND
    1,000500              21.00      11.1         46       25.0          AV          LL     GND
    2.143500              13. 40     11.3         46       32.6          AV          L1     GND
    5.271000               4.20      11.4         50       45.8         av           LL     GND
   24,004500              19. 60     11.7         50       30.4          AV          LL     GND


                             Report No.: ATE20181750
                                          Page 12 of 21




FCC ID: K4E3133PPQ   Shenzhen Accurate Technology Co., Ltd


ACCURATE TECHNOLOGY CO., LTD

CONDUCTED EMISSION STANDARD FCC PART 15C

EUT:                                      Eeavy—Duty Outdoor Access Control Keypad with Proximity Reader
Manufacturer:                             SUPERRIOR ELECTRONICS CORPORATION
Operating Condition: ON
Test Site:                                2#Shielding Room
Operator:                                 Frank
Test Specification:                       N 12v/6082z
Comment:                                  Report NO.:ATE20181750               M/N:    SK—3133—PPQ
Start of Test:                            2018—10—9 / 9:55:54



SCAN TABLE:                   "V        150K—30MHz fin"
  Short Description:                                      _SUB_STD_VTERM2 1
  Start                    Stop              Step            Detector         Meas.       IF          Transducer
  Frequency                Frequency         Width                     Time               Bandw.
  150.0 kiz                30.0 MEz          4.5 kiz         Quasipeak 1.0 s              9 kRz       NSLK8126 2008
                                                             Average


   Level [dBpV




                          300k   400k      600k 800k 1M              am        3      4M 5M 6M     BM 10M          20M   30M
                                                                 Frequency [H2]




MEASUREMENT RESULT:                          "F—1750—4_fin"

2018—10—9             9 188
     Frequency                   Tevel      Transd     Limit     Margin        Detector        Line    PE
           MBz                    dBuy          dB      dsuy         dB

            325500               19. 60       10.9          60          .0      oP             N      GND
             501000              23.80        11.0          56           2     QP              N      GND
          1. 252500              24 .40       11.2          56          .6     P               N      GND
          2.184000               18.50        11.3          56          150    9P              N      GND
          5.271000                9.40        11.4          60          .6     QP              N      GND
            004500               20 .90       11.3          60          1      P               N      GND




MEASUREMENT RESULT:                          "FP—1750—4_ fin2"
2018—10—9             9 158
     Frequency                   Level      Transd     Limit     Margin        Detector        Line    PE
           MBz                     dBuy          dB       dBpy          as
               249000                         10.9          52       33.4      AV              N      GNp
               501000                         11.0          46       25.8       AV             N      GNp
               . 000500                       11.1          46       25.9       AV             N      GNp
  S oo to 1+




               «134500                        1158          46       32.5      AV              N      GND
               031500                         11.5          50       44.8      AV              N      GND
               . 004500                       11.7          50       29.1       Av             N      cup
  to


                                                                                    Report No.: ATE20181750
                                                                                                 Page 14 of 21



          5. RADIATED EMISSION MEASUREMENT


                5.1.Block Diagram of Test
                     5.1.1.Block diagram of connection between the EUT and simulators


                                   AC Mains


                                                        EUT



                     5.1.2.Block diagram of test setup (In chamber)




FCC ID: K4E3133PPQ                                                          Shenzhen Accurate Technology Co., Ltd


                                                                                          Report No.: ATE20181750
                                                                                                       Page 15 of 21



                5.2.Radiated Emission Limit




                     Limit: 2400/125=19.2uV/m@300m
                     Distance Correction Factor=40log (test distance/specific distance)


                5.3.EUT Configuration on Measurement
                     The following equipments are installed on Radiated Emission Measurement to meet the
                     commission requirements and operating regulations in a manner which tends to maximize
                     its emission characteristics in normal application.
                       5.3.1.Heavy-Duty Outdoor Access Control Keypad with Proximity Reader (EUT)
                              Model Number : SK-3133-PPQ
                              Manufacturer : Superior Electronics Corporation


                5.4.Operating Condition of EUT
                       5.4.1. Setup the EUT and simulator as shown as Section 5.1.

                       5.4.2. Turn on the power of all equipment.

                       5.4.3. Let the EUT work in test mode and measure it.




FCC ID: K4E3133PPQ                                                                Shenzhen Accurate Technology Co., Ltd


                                                                                          Report No.: ATE20181750
                                                                                                       Page 16 of 21



                5.5.Test Procedure
                     The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                     ground. The turntable can rotate 360 degrees to determine the position of the maximum
                     emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted
                     on an antenna tower. The antenna can be moved up and down between 1.0 meter and 4
                     meters to find out the maximum emission level. Broadband antenna (calibrated bilog
                     antenna) is used as receiving antenna. Both horizontal and vertical polarizations of the
                     antenna are set on measurement. In order to find the maximum emission levels, all of the
                     interface cables must be manipulated according to ANSI C63.10: 2013 on radiated
                     emission measurement.

                     From 9kHz to 30MHz at distance 3m The EUT was rotated a full revolution in order to
                     obtain the maximum value of the electric field intensity.

                     From 30MHz to 1000MHz at distance 3m The measuring antenna height varied between
                     1 and 4m and EUT was rotated a full revolution in order to obtain the maximum value of
                     the electric field intensity. The measurements were performed for both vertical and
                     horizontal antenna polarization.

                     The final measurement will be performed with an EMI Receiver set to Quasi Peak
                     detector for the frequency bands 9kHz to 90kHz and 110 to 490 kHz where an average
                     detector will be used according to Section 15.209(d)(2).

                     The final level, expressed in dBuV/m, is arrived at by taking the reading from the EMI
                     receiver(Level dBuV) and adding the antenna correction factor and cable loss
                     factor(Factor dB) to it. This result then has to be compared with the relevant FCC limit.
                     The resolution bandwidth during the measurement is as follows:

                     9kHz – 150kHz: ResBW: 200Hz

                     150kHz – 30MHz: ResBW: 9kHz

                     The bandwidth of the EMI test receiver (R&S ESCS30) is set at 120kHz from 30MHz to
                     1000MHz.




FCC ID: K4E3133PPQ                                                                Shenzhen Accurate Technology Co., Ltd


                                                                                         Report No.: ATE20181750
                                                                                                      Page 17 of 21



                5.6.Data Sample
           Frequency(    Reading        Factor          Result       Limit         Margin           Remark
           MHz)          (dBv)         (dB/m)          (dBv/m)     (dBv/m)      (dB)
           X.XX          49.83          -22.03          27.80        43.50         -15.70           QP

                     Frequency(MHz) = Emission frequency in MHz
                     Reading(dBv) = Uncorrected Analyzer/Receiver reading
                     Factor (dB/m)= Antenna factor + Cable Loss – Amplifier gain
                     Result(dBv/m) = Reading + Factor
                     Limit (dBv/m)= Limit stated in standard

                     Calculation Formula:

                     Margin(dB) = Result (dBv/m)–Limit(dBv/m)

                     Result(dBv/m)= Reading(dBv)+ Factor(dB/m)

                     The “Margin” column of the following data tables indicates the degree of compliance
                     with the applicable limit. For example, a margin of -7dB means the emission is 7dB
                     below the limit.


                5.7.Radiated Emission Measurement Result
                     PASS.

                     The EUT has pretest form 12V to 24V AC/DC, the worst case data 24Vac was recorded
                     in the report

                     Emissions attenuated more than 20 dB below the permissible value are not reported.

                     The spectral diagrams are attached as below.




FCC ID: K4E3133PPQ                                                               Shenzhen Accurate Technology Co., Ltd


                                                                                        Report No.: ATE20181750
                                                                                                     Page 18 of 21
                                            From 9kHz to 30MHz:TX Mode

            Polarization: X
Frequency         Reading      Factor         Result   Limit @3m   Margin                  Height          Degree
                                                                            Detector
  (MHz)          (dBuV/m)       (dB)        (dBuV/m)   (dBV/m)     (dB)                    (cm)           (deg.)
  *0.125           50.20       11.77          61.97      102.32    -40.35     QP             124            176
   0.552           40.93        3.54          44.47       72.76    -28.29     QP             150            355
   0.920           35.04        0.66          35.67       68.32    -32.65     QP             202            228
   1.288           29.43       -0.28          29.15       65.41    -36.26     QP             145            208
  18.516           29.76       -4.86          24.90       69.54    -44.64     QP             154             35
  29.594           27.60       -7.02          20.58       69.54    -48.96     QP             148             38

            Polarization: Y
Frequency         Reading      Factor         Result   Limit @3m   Margin                  Height          Degree
                                                                            Detector
  (MHz)          (dBuV/m)       (dB)        (dBuV/m)   (dBV/m)     (dB)                    (cm)           (deg.)
  *0.125           46.19       11.77          57.96      102.32    -44.36     QP             112            201
   0.368           34.28        6.13          40.41       96.29    -55.88     QP             139            138
   0.552           34.25        3.54          37.79       72.76    -34.97     QP             120            323
   0.920           32.41        0.66          33.07       68.33    -35.26     QP             150            230
   1.288           25.71       -0.28          25.43       65.41    -39.98     QP             154            193
  18.802           35.22       -4.95          30.27       69.54    -39.27     QP             135            330

         Polarization: Z
Frequency         Reading      Factor         Result   Limit @3m   Margin                   Height         Degree
                                                                            Detector
  (MHz)          (dBuV/m)       (dB)        (dBuV/m)   (dBV/m)     (dB)                     (cm)          (deg.)
  *0.125           45.22       11.77          56.99      102.32    -45.33     QP              130           146
   0.588           34.49        3.54          38.03       72.21    -34.18     QP              201           301
   0.920           30.19        0.66          30.85       68.33    -37.48     QP              156           258
   1.288           27.85       -0.28          27.57       65.41    -37.84     QP              200           322
  18.147           23.92       -4.86          19.06       69.54    -50.48     QP              236           146
  29.361           25.36       -7.02          18.34       69.54    -51.20     QP              145           198

            “ * ” : Fundamental frequency

            Part 15 Section 15.31(f)(2) (9kHz-30MHz)

            Limit at 3m=Limit@300m-40*log(3(m)/300(m))

            Limit at 3m=Limit@30m-40*log(3(m)/30(m))




  FCC ID: K4E3133PPQ                                                            Shenzhen Accurate Technology Co., Ltd


                                                                                                                                 |
mifi!                                          ACCURATE TECHNOLOGY CO., LTD.                                                      Site: 1# Chamber
                                               F1,Bldg.A, Changyuan New Material Port Keyuan Rd,                       Tel:+86—0755—26503290
                                               Science & Industry Park, Nanshan Shenzhen,P.R.China                     Fax:+86—0755—26503396
 Job No.:           frank2018 #1812                                                         Polarization:         Horizontal
 Standard: FCC Part 150C 3M Radiated                                                        Power Source:           AC 24V/60Hz
 Test item:             Radiation Test                                                      Date: 2018/10/11
 Temp.(           C)/Hum.(%) 25           C/55%                                             Time: 10:54:13
 EUT:                   Heavy—Duty Outdoor Access Control Keypad with Proximity Reader
 Mode:              TX 125KHz
 Model:             SK—3133—PPQ
 Manufacturer: SUPERRIOR ELECTRONICS CORPORATION

 Note:            Report NO.:ATE20181750



         70.0      dBu¥/m
                                                                                                                      uB                ——


         60



         50



         a0

         30

         BB      |relis<>> fersecoefrnnnedenconfrenipersfee« $


         10


         0.0                                                                            I            ‘                       .           ;

               30.000     40      50     60     70   80                                300         400      500     600     700       1000.0 MHz


                    Freq.          Reading           Factor      Result   Limit   |Margin                Height     Degree
   No.             (MHz)    (dBuV/m)                  (dB) (dBuv/im) (dBuvim)| (aBy P4°C| (em)                      (deg)            Remark
                   2ro8161| 4765                     1711    3054      4600 |—1546) aop 200                           52
—A




                   2882830| arse                     1653    3133      4600 |—1467) oP 200                           231
N|




                    295.4623|          48.65         —16.35      32.30    46.00   |—13.70|      QP       200        202
mlool




                    307.1051]          47.60         —16.12      31.48    46.00   |—14.52]      QP       200          98
                    326.0079]|         45.68         —15.55      30.13    46.00   |—15.87|      QP       200         102
l




                    376.5227)          4345          —14.18      29.27    46.00   |—16.73|      QP       200         156
o|


                                                                                                                                           |
mi!                                         ACCURATE TECHNOLOGY CO., LTD.                                                                  Site: 1# Chamber
                                             F1,Bidg,A,Changyuan New Material Port Keyuan Rd,                                   Tel:+86—0755—26503290
                                             Science & Industry Park,Nanshan Shenzhen,P.R.China                                 Fax:+86—0755—26503396
Job No.:         frank2018#1813                                                                        Polarization:       Vertical
Standard: FCC Part 15C 3M Radiated                                                                     Power Source:         AC 24V/60Hz
Test item:           Radiation Test                                                                    Date: 2018/10/11
Temp.(          C)/Hum.(%) 25               C/55%                                                      Time: 10:59:33
EUT:                 Heavy—Duty Outdoor Access Control Keypad with Proximity Reader
Mode:            TX 125KHz
Model:    SK—3133—PPQ
Manufacturer: SUPERRIOR ELECTRONICS CORPORATION
Note:          Report NO.:ATE20181750



       70.0      dBu¥/m
                                                                                                                                limit1 :         ——



       t                i                      ;                                                   i           ;                      i

       50



       40




       30




       s                                                               ..b P M Pb ds

       10




       0o               ;               }          P                                               }                                  1
            30.000      40      50     60     70   80                                             300          400     500    600   700         1000.0 MHz




 No:            (iarfii')        (ggfiijff"n?)       F(Z‘é‘)‘”   (dgis\;:’:n) (dIE;Lr{]/iltm) Nézrg)in Detector H(sirfl?l fg;g(_;ef               Remark
                     72.7202)        5012          —23.00        27.12          40.00      |—12.88|       QP         100      106
——




                 119.7672)           58.32         —21.32        37.00          43.50       |—6.50|       QP         100      59
NJ




                 122.7493|           58.16         —21.45        36.71          43.50       |—6.79|       QP         100      210
oJ




                 130.3048]           60.12         —21.74        38.38          43.50       |—5.12|)      QP         100      322
)




                 154.2427|           56.01         —21.95        34.06          43.50       |—9.44|       QP         100      156
l




                 252.2522|           5312          ~18.05        35.07          46.00      |—10.93]       QP         100       13
o|


                                                                                          Report No.: ATE20181750
                                                                                                       Page 21 of 21



          6. ANTENNA REQUIREMENT


             6.1.The Requirement
                     According to Section 15.203, an intentional radiator shall be designed to ensure that no
                     antenna other than that furnished by the responsible party shall be used with the device.


             6.2.Antenna Construction
                     Device is equipped with permanent attached antenna, which isn’t displaced by other
                     antenna. The max Antenna gain of EUT is 0dBi. Therefore, the equipment complies with
                     the antenna requirement of Section 15.203.




                                                Antenna




                                          ***** End of Test Report *****




FCC ID: K4E3133PPQ                                                                Shenzhen Accurate Technology Co., Ltd



Document Created: 2018-11-07 10:13:21
Document Modified: 2018-11-07 10:13:21

© 2025 FCC.report